*COMDECK COMCAPR
                                  # 
          CTEXT  COMCAPR - RHF APPLICATION INSTALLATION PARAMETERS. 
                                  # 
                                                 CONTROL NOLIST;
                                                 CONTROL IFEQ LISTCON,1;
                                                 CONTROL LIST;
                                                 CONTROL ENDIF; 
                                  # 
  
          BASE   D
  
*         COMMENT  COPYRIGHT CONTROL DATA SYSTEMS INC. 1994.
  
  
***       COMCAPR - RHF APPLICATION INSTALLATION PARAMETERS.
  
  
***       THIS DECK CONTAINS THE ONLY INSTALLATION-CHANGABLE PARAMETERS 
*         USED BY THE REMOTE HOST FACILITY APPLICATIONS.  THE FORMAT OF 
*         THE FOLLOWING DEFINITIONS IS ACCEPTABLE TO BOTH SYMPL AND 
*         COMPASS (VIA ##DEF## MACRO, SEE COMMON DECK *COMQMAC*). 
*         DOUBLE CHECK COMPASS VALUES WHEN ALTERING A DEFINITION. 
  
**    ACKNW - MAXIMUM NUMBER OF RESTART CHECKMARKS WHICH ARE TO BE
*             TRANSMITTED BY THE SENDER BEFORE RECEIVING ACKNOWLEDGEMENT
*             FROM THE RECEIVER.
* 
*           RANGE 1 - 255 (RHF) 1 - 31 (NAM). 
*           DEFAULT = 2.           #
  
#ACKNW    #DEF#   2   #ACKNW  #2#; # DEFAULT RESTART CHECKMARKS#
#MINACKW  #DEF#   1   #MINACKW#1#; # MINIMUM RESTART CHECKMARKS#
#MAXACKW  #DEF#   31  #MAXACKW#31#; # MAXIMUM RESTART CHECKMARKS# 
                                   #
  
**    ACNMAXC - THE MAXIMUM NUMBER OF CONNECTIONS ALLOWED.
* 
*     RANGE  1 - 4. 
*     DEFAULT  4. 
                                  # 
#ACNMAXC  #DEF#    4   # ACNMAXC   #4#;  # MAX NO. OF CONNECTIONS # 
                                  # 
  
**    NAMDBZ - MINIMUM BLOCK SIZE INITIATOR APPLICATIONS WILL SELECT
*              FOR RFT PARAMETER 12 ON NAM CONNECTIONS. 
*              (FOR RHF CONNECTIONS, THE BLOCK SIZE IS DETERMINED 
*              SOLELY BY THE DATA DECLARATION - SEE ROUTINE *MBZ*). 
* 
*     LEGAL RANGE 0 - 9999. 
* 
*     DEFAULT VALUE =  512 BYTES. 
                                  # 
  
 #NAMDBZ  #DEF# 512D #NAMDBZ  #512#;  # MINIMUM BLOCK SIZE #
                                  # 
          SPACE  2,12 
          SPACE  2,12 
  
  
**        MAXRTRY - MAXIMUM NUMBER OF RETRIES APPLICATION FTF WILL
*                ATTEMPT WHEN USER ERROR PROCESSING IS NOT SELECTED.
* 
*         LEGAL RANGE 0 - (2**17)-1.
* 
*         DEFAULT VALUE =  3 RETRYS.
                                  # 
  
 #MAXRTRY #DEF#  03D #MAXRTRY #03#;  # MAXIMUM RECOVERY RETRY COUNT # 
                                  # 
          SPACE  2,12 
  
  
**        TERT - TIMED EVENT ROLLOUT TIME FOR PTFS PERMANENT FILE 
*                REQUESTS WHICH MUST WAIT FOR A SYSTEM EVENT (E.G. FILE 
*                BUSY). 
* 
*         LEGAL RANGE 1 - 4095 SECONDS. 
* 
*         DEFAULT VALUE = 100 SECONDS.
                                  # 
  
 #TERT    #DEF#  100D  #TERT #100#;  # TIMED EVENT ROLLOUT TIME # 
                                  # 
  
**    NAKRTRY - MAXIMUM NUMBER OF RETRIES WHEN NAK RESPONSE RECEIVED. 
* 
*     RANGE 0 - 4095. 
*     DEFAULT 1000 RETRIES. 
                                  # 
#NAKRTRY  #DEF#   1000D  # NAKRTRY  #1000#;  # MAXIMUM NAK RETRY COUNT #
                                  # 
  
**    NTLMAX - MAXIMUM SIZE OF TEXT BLOCK EXPECTED ON ANY CONNECTION. 
                                  # 
#NTLMAX   #DEF#  273D  # NTLMAX  #273#;  # MAXIMUM BLOCK SIZE # 
                                  # 
  
**    PLTLEN - LENGTH OF PID/LID TABLE (PLT) IN QTF (INITIATOR).
*              THE PLT USES 2 WORDS FOR EACH PID AND ITS FIRST LID
*              PLUS ONE WORD FOR EVERY 3 ADDITIONAL LIDS PER PID
*              IN THE NOS SYSTEM LID TABLE OR, ON NOS/BE, IN THE
*              RHF NETWORK DESCRIPTION TABLE: 
*                   PLTLEN .GE. (NPID*2) + (((NLID-1)+2)/3) 
*                             NPID = TOTAL NUMBER OF PID-S DEFINED. 
*                             NLID = TOTAL NUMBER OF LID-S DEFINED. 
* 
*     MINIMUM 3 WORDS (1 PID AND 1 LID).
*     DEFAULT - 128 WORDS.
                                  # 
 #PLTLEN   #DEF# 256D #  PLTLEN   #256#;  # MAX PLT SIZE #
                                  # 
  
**    TIMEOUT - THE TIME IN WHICH A RESPONSE MUST BE RECEIVED FROM THE
*               ACCESS METHOD OR REMOTE HOST BEFORE THE CONNECTION IS 
*               ABORTED.
* 
*     RANGE 1 - 1800 SECONDS. 
*     DEFAULT 600 SECONDS.
                                  # 
#TIMEOUT  #DEF#  600D  # TIMEOUT #600#;  # TIMEOUT TIME # 
                                  # 
  
**    LTXTBFW - LENGTH OF QTF/QTFS TEXT BUFFER IN WORDS.
*     LTXTBFC - MAXIMUM NUMBER OF TEXT CHARACTERS IN TEXT BUFFER. 
*               EACH TEXT BUFFER HAS A ONE WORD HEADER. 
*               THE MAXIMUM ALLOWED TEXT BUFFER SIZE IS 260 CHARACTERS, 
*               WHICH REQUIRES (260+9)/10 + 1 = 27 WORDS. 
*               THESE TWO DEFINITIONS SHOULD NOT BE CHANGED.
                                  # 
#LTXTBFW  #DEF#  27D #LTXTBFW  #27#;  # SIZE OF QTF TEXT BUFFER # 
#LTXTBFC  #DEF# 260D #LTXTBFC #260#;  # CHARACTERS IN TEXT BUFFER # 
                                  # 
  
**    NETWTYP - NETWORK INTERFACES. 
*     NETWRHF - RHF/FIP.
*     NETWNAM - NAM/AIP.
                                  # 
#NETWRHF  #DEF#   0D #NETWRHF  #00#;  # RHF/FIP # 
#NETWNAM  #DEF#   1D #NETWNAM  #01#;  # NAM/AIP # 
                                  # 
  
          BASE   *
  
          ENDX
                                  # 
                                     # END OF COMDECK COMCAPR # 
                                                 CONTROL LIST;