1CL 
          IDENT  1CL,ALC
          PERIPH
          BASE   MIXED
          SST 
          SYSCOM
*COMMENT  1CL - CPP FIRMWARE LOADER.
          COMMENT  COPYRIGHT CONTROL DATA SYSTEMS INC.  1992. 
          TITLE  1CL - CPP FIRMWARE LOADER. 
          SPACE  4
***       1CL - CPP FIRMWARE LOADER.
* 
*         S. L. BETH.        86/07/25.
          SPACE  4
***              1CL IS LOADED INTO A CPP BY *BCL* TO LOAD FIRMWARE TO
*         CPP CONTROLLERS.  1CL THEN LOADS THE FIRMWARE FROM THE CM 
*         BUFFER THAT *BCL* HAS SET UP. 
          SPACE  4
***       CALL. 
* 
* 
*T IR     18/  *1CL*,1/,5/  CP,36/
*T MB     12/  CH,12/  RL,12/  DSTO,24/  CMA
* 
*         CH     CHANNEL TO AUTOLOAD. 
*         RL     FIRMWARE RECORD LENGTH.
*         DSTO   DEADSTART OPTIONS. 
*         CMA    CM ADDRESS OF FIRMWARE RECORD. 
* 
*         MB = 12/7777,48/0 WHEN LOAD COMPLETE. 
          SPACE  4
***       OPERATOR MESSAGES.
* 
*         LINE 2 OF DEADSTART CONTROL POINT - 
* 
*         *TO CONTROLLER.* = THE FIRMWARE RECORD LISTED IN THE LINE 1 
*         MESSAGE AT THE DEADSTART CONTROL POINT IS BEING AUTOLOADED TO 
*         THE CHANNEL AND EQUIPMENT TYPE LISTED IN THE LINE 1 MESSAGE.
*         IF THE DEADSTART STOPS WITH THIS MESSAGE AND THE LINE 1 
*         MESSAGE LISTED ABOVE DISPLAYED, A CONTROLLER OR CHANNEL 
*         MALFUNCTION OR INCORRECT EQPDECK EQUIPMENT DEFINITION HAS 
*         CAUSED THE AUTOLOAD PROGRAM TO HANG.
* 
*         *AUTOLOAD FAILURE, STXXXX.* = FOLLOWING THE AUTOLOADING OF
*         THE RECORD LISTED IN THE LINE 1 MESSAGE AT THE DEADSTART
*         CONTROL POINT TO THE CHANNEL AND EQUIPMENT TYPE LISTED IN THE 
*         LINE 1 MESSAGE, CONTROLLER STATUS (STXXXX) INDICATED THAT A 
*         CHANNEL PARITY ERROR OR FIRMWARE CHECKSUM ERROR OCCURED FOR 
*         THE AUTOLOAD.  A STATUS OF *ST0000* INDICATES THAT THE
*         CHANNEL WAS DISCONNECTED WITHOUT STATUS BEING SENT.  WHEN 
*         THIS MESSAGE IS DISPLAYED, DEADSTART STOPS UNTIL THE *GO* 
*         COMMAND IS ENTERED BY THE OPERATOR.  WHEN THE *GO*
*         COMMAND IS ENTERED, THE AUTOLOAD IS RETRIED.  IF SEVERAL
*         RETRIES CONTINUE TO PRODUCE THIS MESSAGE AND THE LINE 1 
*         MESSAGE LISTED ABOVE, A SOLID HARDWARE FAILURE OR BAD 
*         FIRMWARE RECORD ON THE DEADSTART TAPE IS INDICATED. 
* 
*         * FUNCTION XXXX TIMEOUT.* = FUNCTION XXXX WAS NOT 
*         ACCEPTED BY THE CONTROLLER, NOTIFY THE SITE CE. 
          SPACE  4
*CALL     COMPMAC 
*CALL     COMSDSL 
*CALL     COMSPIM 
*CALL     COMPCHM 
  
 OPMESS   SPACE  4,10 
**        OPMESS - SEND OPERATOR MESSAGE. 
* 
*         OPMESS MADD,LINE
* 
*         MADD = ADDRESS OF MESSAGE.
*         LINE = 1 FOR A LINE ONE MESSAGE.
*              = 2 FOR A LINE TWO MESSAGE.
  
  
 OPMESS   MACRO  MADD,LINE
          LDC    200*DSCP+MS_LINE_W 
          CWM    MADD,TR
          ENDM
          SPACE  4
****      DIRECT LOCATION ASSIGNMENTS.
  
  
 CN       EQU    20 - 24     CM WORD BUFFER (5 LOCATIONS) 
 FN       EQU    30 - 34     CM WORD BUFFER (5 LOCATIONS) 
 NC       EQU    35          NUMBER OF CONTROL POINTS 
 TP       EQU    43          TEMP 
 RL       EQU    44          RECORD LENGTH
 DS       EQU    45          DEADSTART OPTIONS
 CA       EQU    46 - 47     CURRENT CENTRAL ADDRESS (2 LOCATIONS)
****
          SPACE  4
*         ASSEMBLY CONSTANTS. 
  
  
 BUF      EQU    TPBA        TAPE BLOCK BUFFER
 FWBF     EQU    BUF         FIRMWARE BUFFER
 FWBFL    EQU    1000        FIRMWARE BUFFER LENGTH (CM WORDS)
 FCCN     EQU    0           CONNECT FUNCTION 
 FCOC     EQU    10          OPERATION COMPLETE FUNCTION CODE 
 FCGR     EQU    11          GRENADE FUNCTION CODE
 FCGS     EQU    12          GENERAL STATUS FUNCTION CODE 
 FCLC     EQU    71          LOAD CONTROL MODULE CONTROLWARE FROM PP
 FCAL     EQU    414         AUTOLOAD FUNCTION CODE 
          TITLE  MAIN PROGRAM.
 1CL      SPACE  4
**        1CL - MAIN PROGRAM. 
  
  
          ORG    PPFW 
  
 ALC      SPACE  4,20 
**        ALC - AUTOLOAD CONTROLLER.
* 
*         EXIT   CONTROLLER AUTOLOADED WITH FIRMWARE. 
*                CONTROLLER GRENADED IF DEADSTART OPTION SPECIFIED. 
*                WAITS FOR OPERATOR GO IF AN AUTOLOAD FAILURE OCCURS. 
* 
*         CALLS  C2D, FCN, MCI, OFR, PRS, STS, WOG. 
* 
*         MACROS DCHAN, OPMESS, RCHAN.
  
  
 ALC      RJM    PRS         PRESET PROGRAM 
          RJM    MCI         MODIFY CHANNEL INSTRUCTIONS
          LDD    T4          RESERVE CHANNEL
          RCHAN 
          DCN    CH          INSURE CORRECT CHANNEL STATE 
 ALC1     OPMESS MSGA,2 
          LDC    1S15        MASTER CLEAR THE CHANNEL ADAPTOR 
          RJM    FCN
          LDC    FCAL        ISSUE AUTOLOAD FUNCTION
          RJM    FCN
          RJM    OFR         LOAD CONTROLWARE 
          RJM    STS
          ZJN    ALC2        IF AUTOLOAD SUCCESSFUL 
          SHN    -6          PUT STATUS IN MESSAGE
          RJM    C2D
          STM    MSGB+12
          LDD    FN 
          RJM    C2D
          STM    MSGB+13
          LDC    MSGB        DISPLAY AUTOLOAD FAILURE MESSAGE 
          RJM    WOG
          UJN    ALC1        RETRY AUTOLOAD 
  
 ALC2     LDD    DS          CHECK DEADSTART OPTIONS
          LPN    1
          ZJN    ALC3        IF *GRENADE* NOT SPECIFIED 
          LDN    FCGR        ISSUE GRENADE FUNCTION 
          RJM    FCN
 ALC3     LDN    FCOC        ISSUE OPERATION COMPLETE 
          RJM    FCN
          LDD    T4          RELEASE CHANNEL
          DCHAN 
          LCN    0           SET LOAD COMPLETE
          STD    CM 
          LDD    MA 
          CWD    CM 
          MONITOR  DPPM 
          LJM    PPR         EXIT 
 FCN      SPACE  4,15 
**        FCN - ISSUE FUNCTION TO CONTROLLER. 
* 
*         ENTRY  (A) = FUNCTION CODE. 
* 
*         EXIT   (A) = 0 IF GENERAL STATUS FUNCTION TIMED OUT.
* 
*         USES   FN.
* 
*         CALLS  C2D. 
* 
*         MACROS OPMESS.
  
  
 FCN      SUBR               ENTRY/EXIT 
          STD    FN 
 FCN1     FAN    CH 
 FCN2     IJM    FCNX,CH     IF FUNCTION ACCEPTED 
          ADD    ON 
          NJN    FCN2        IF TIMEOUT NOT SATISFIED 
          DCN    CH 
          LDD    FN          CHECK FUNCTION 
          LMN    FCGS 
          ZJN    FCNX        IF GENERAL STATUS REQUEST
          SHN    -6 
          RJM    C2D
          STM    FCNB 
          LDD    FN          CONVERT FUNCTION FOR MESSAGE 
          RJM    C2D
          STM    FCNB+1 
          OPMESS FCNA,2      DISPLAY TIMEOUT MESSAGE
          LDD    FN 
          UJN    FCN1        RETRY
  
 FCNA     DATA   10H FUNCTION 
 FCNB     DATA   C*0000 TIMEOUT.* 
 MCI      SPACE  4,10 
**        MCI - MODIFY CHANNEL INSTRUCTIONS.
* 
*         ENTRY  (T4) = CHANNEL NUMBER. 
* 
*         USES   T1, T2, T3.
  
  
 MCI1     STD    T2          SET INSTRUCTION ADDRESS
          LDI    T2 
          SCN    37 
          LMD    T3          MODIFY INSTRUCTION 
          STI    T2 
          AOD    T1          ADVANCE LIST ADDRESS 
 MCI2     LDI    T1 
          NJN    MCI1        IF NOT END OF LIST 
  
 MCI      SUBR               ENTRY/EXIT 
          LDD    T4 
          LPN    37          REMOVE CONCURRENT FLAG 
          STD    T3 
          LDC    CTCH        SET CHANNEL TABLE ADDRESS
          STD    T1 
          UJN    MCI2        ENTER LOOP 
 OFR      SPACE  4,20 
**        OFR - OUTPUT FIRMWARE RECORD. 
* 
*         ENTRY  (CA - CA+1) = CENTRAL MEMORY ADDRESS OF FIRMWARE 
*                              RECORD.
*                (RL) = WORD COUNT OF FIRMWARE RECORD.
*                CONTROLLER FUNCTIONED FOR AUTOLOAD.
* 
*         EXIT   FIRMWARE RECORD TRANSFERRED FROM CENTRAL MEMORY TO 
*                CONTROLLER.
*                CHANNEL INACTIVE.
* 
*         USES   T1, T2, T5, T6.
  
  
 OFR3     FJM    *,CH        WAIT FOR LAST WORD ACCEPT
          DCN    CH 
  
 OFR      SUBR               ENTRY/EXIT 
          LDD    CA          SET CENTRAL MEMORY ADDRESS OF RECORD 
          STD    T5 
          LDD    CA+1 
          STD    T6 
 OFRA     ACN    CH          PREPARE CHANNEL FOR OUTPUT 
*         PSN                (IF 819 DRIVER LOAD) 
          LDD    RL          RECORD WORD COUNT
 OFR1     ZJN    OFR3        IF END OF RECORD 
          STD    T2          SAVE REMAINING WORD COUNT
          STD    T1          SET BLOCK WORD COUNT 
          ADC    -FWBFL-1 
          MJN    OFR2        IF REMAINING DATA FITS IN BUFFER 
          LDC    FWBFL       SET BLOCK COUNT TO BUFFER SIZE 
          STD    T1 
 OFR2     LDD    T5          SET CENTRAL BUFFER ADDRESS 
          SHN    14 
          LMD    T6 
          CRM    FWBF,T1     READ BLOCK FROM CENTRAL MEMORY 
          STD    T6          SAVE NEXT CENTRAL MEMORY BUFFER ADDRESS
          SHN    -14
          STD    T5 
          LDD    T1          OUTPUT BLOCK TO CONTROLLER 
          SHN    2
          ADD    T1 
          OAM    FWBF,CH
          LDD    T2          DECREMENT REMAINING RECORD WORD COUNT
          SBD    T1 
          UJN    OFR1        PROCESS NEXT BLOCK 
 STS      SPACE  4,10 
**        STS - STATUS CONTROLLER.
* 
*         EXIT   (A) = (FN) = GENERAL STATUS. 
*                (A) = 775777 IF INCOMPLETE STATUS. 
*                (FN) = 5777 IF INCOMPLETE STATUS.
* 
*         CALLS  FCN. 
  
  
 STS      SUBR               ENTRY/EXIT 
          LDN    FCGS 
          RJM    FCN
          ZJN    STS1        IF FUNCTION TIMED OUT
          ACN    CH 
 STS1     LDC    -2000       ERROR STATUS 
 STSA     IAN    CH 
*         IAN    CH+40       INPUT STATUS 
          STD    FN 
          UJN    STSX        RETURN 
 WOG      SPACE  4,10 
**        WOG - WAIT FOR OPERATOR *GO.*.
* 
*         ENTRY  (A) = ADDRESS OF MESSAGE TO BE WRITTEN TO MS2W.
* 
*         EXIT   (A) = 0. 
*                OPERATOR ENTERED *GO.* COMMAND.
* 
*         USES   T1, CM - CM+4. 
* 
*         MACROS PAUSE. 
  
  
 WOG      SUBR               ENTRY/EXIT 
          STM    WOGA        SET MESSAGE ADDRESS
          LDD    NC 
          SHN    7           READ SENSE SWITCH WORD 
          ADN    SNSW 
          STD    T1          SAVE ADDRESS 
          CRD    CM 
          LDD    CM+3        SET PAUSE BIT
          SCN    1
          LMN    1
          STD    CM+3 
          LDD    T1 
          CWD    CM 
          ADN    MS2W-SNSW   WRITE MESSAGE TO MS2W
          CWM    *,TR 
 WOGA     EQU    *-1         MESSAGE ADDRESS
 WOG1     PAUSE  NE 
          LDD    T1          CHECK PAUSE BIT
          CRD    CM 
          LDD    CM+3 
          LPN    1
          ZJN    WOGX        IF PAUSE BIT CLEAR 
          UJN    WOG1        LOOP 
          SPACE  4,10 
**        CONSOLE MESSAGES. 
  
  
 MSGA     DATA   C*TO CONTROLLER.*
 MSGB     DATA   C*AUTOLOAD FAILURE, ST0000.* 
          SPACE  4,10 
**        COMMON DECKS. 
  
  
*CALL     COMPC2D 
 TCHS     SPACE  4,10 
**        CHANNEL TABLE.
  
  
          CHTB   CH 
 PRS      SPACE  4,10 
**        PRS - PRESET PROGRAM. 
* 
*         EXIT   (NC) = NUMBER OF CONTROL POINTS. 
*                (RL) = FIRMWARE RECORD LENGTH. 
*                (DS) = DEADSTART OPTIONS.
*                (T4) = CHANNEL.
*                (CA - CA+1) = CMA OF FIRMWARE RECORD.
* 
*         USES   DS, NC, RL, TP, T4, CA - CA+1. 
  
  
 PRS      SUBR               ENTRY/EXIT 
          LDD    MA          READ LOAD PARAMETERS 
          CRD    TP 
          LDD    TP          SET CHANNEL
          STD    T4 
          LDK    NCPL        SET NUMBER OF CONTROL POINTS 
          CRD    CM 
          LDD    CM+1 
          STD    NC 
          UJN    PRSX        RETURN 
          END 