*COMDECK HISTORY   HISTORY INFORMATION. * 
* MALET   GLG    78/04/11.
*         MODSET CORRECTS PROBLEM ON DPSR 019191 WHERE THE WORD 
*         UNRECOGNIZED IS SPELLED INCORRECTLY.
* 
* 
* MALET   GLG    78/04/12.
*         MODSET MAL001GLG CORRECTS PROBLEM REPORTED ON DPSR 019185 
*         WHERE MALET REQUESTS 30K OF CM WHERE IT SHOULD REQUEST 25K. 
* 
* 
* CAUTIONS GLG   78/04/12.
*          MODSET MAL002GLG CORRECTS PROBLEM REPORTED ON DPSR 019190. 
*          IF EQUIPMENT IS BEING TESTED AND IS TURNED ON THE OPERATING
*          SYSTEM WILL BEGIN TO USE EQUIPMENT.  MODSET ADDS CAUTION 
*          NOTE INTO CAUTIONS DECK ON CML3.0
* 
* 
* D44     GLG    78/04/11.
*         MALET D4401 AND D4402 GET ERRORS DUE TO WC REGISTER NOT BEING 
*         CLEARED ON NOSBE.   PROBLEM REPORTED BY DPSR 019184.
* 
* 
* D44     GLG    78/04/12.
*         MODSET D44001GLG FIXES PROBLEM REPORTED ON DPSR 019187
*         WHERE D44 DOES NOT HANDLE ABORT ON A VERIFY CORRECTLY.
* 
* 
* CAUTIONS KBS  78/04/14. 
*         MODSET FTP000KBS CORRECTS PROBLEM REPORTED ON DPSR 09192. 
*         HARDWARE ERROR IN PFC PRINTERS CAUSES FTP43 TO OPERATE
*         INCORRECTLY.  MODSET ADDS CAUTION NOTE INTO 
*         CAUTIONS DECK ON CML3.0.
* 
* 
* INSTLDKS GLG   78/04/19.
*          INSTALL DECK FOR NOSBE HAS WRONG FTN CARD TO ASSEMBLE
*          REGEN.  CARD NEED TO BE CHANGED TO HAVE S=CPCTEXT ADDED. 
* 
* 
* TFE     KBS 78/05/02
*  MODSET TFE000KBS CORRECTS COMPILE ERRORS INDUCED BY
*  COMPILER ENHANCEMENTS FOR CML3.1 REPORTED IN DPSR 019302.
* 
* 
* T7W     KBS 78/05/02
*  MODSET T7W000KBS CORRECTS COMPILE ERRORS INDUCED BY
*  COMPILER ENHANCEMENTS FOR CML3.1 REPORTED IN DPSR 019305.
* 
* 
* FTP     KBS 78/05/02
*  MODSET FTP001KBS CORRECTS COMPILE ERRORS INDUCED BY
*  COMPILER ENHANCEMENTS FOR CML3.1 REPORTED IN DPSR 019302.
* 
* 
* T6X     GLG    78/05/01.
*         MODSET CORRECTS T6X ASSEMBLY ERRORS ON CML 3.1
*         DPSR 019303.
* 
* 
* RT5     KBS 78/05/02
*  MODSET RT5000KBS CORRECTS COMPILE ERRORS INDUCED BY
*  COMPILER ENHANCEMENTS FOR CML3.1 REPORTED IN DPSR 019302.
* 
* 
* T7X     KBS 78/05/02
*  MODSET T7X000KBS CORRECTS COMPILE ERRORS INDUCED BY
*  COMPILER ENHANCEMENTS FOR CML3.1 REPORTED IN DPSR 019304.
* 
* 
* MALET   GLG    78/07/25.
* MALET   KBS    78/07/25.
*         CODE ADDED FOR THE FOLLOWING FEATURES AND FIXES.
* 
*         1. ADD FMD COMPILER SUPPORT FOR FMD-885.
*         2. ADD MALET VERSION NUMBER AS PAGE BANNER. 
*         3. ADD TIME STAMP ON OUTPUT LINES.
*         4. CONVERT MALET TO OVERLAYS TO REDUCE FL.
*         5. SIMPLIFIED DUP STATEMENT.
*         6. REMOVE SYSPOS AND SYSEOF.
*         7. ALLOW MSG X TO LINE BN+VALUE.
*         8. ALLOW NON-I/O ON IF STATEMENT. 
*         9. ALPHA SUBSTITUTION WITHIN FORMAT STATEMENTS. 
*        10. ADD SCRATCH REGISTERS B8-B15.
*        11. MOVE PARAMETER REGISTERS TO MEMORY.
*        12. ADD TIMEOUT COMMAND TO LOW LEVEL.
*        13. SOURCE CODE SAVED ON RFILE IF ERRORS COMPILING.
*        14. SEND DIRECTIVE TO SEND MSG TO OUTPUT AND B DISPLAY.
*        15. ERROR PROCESSING ADDED TO NOSBE IF MALET ABORTED.
*        16. TWO OUTPUT FILES SUPPORTED IF TERMINAL.
*        17. CROSS REFERENCE MAP ADDED PER MODULE.
*        18. GLOBAL CROSS REFERENCE MAP IF MAP ON MALET CALL. 
*        19. P REG UPDATING DELETED FROM DRIVER CODE AND ADDED
*            TO COMPILER CODE GENERATED.
*        20. OFF-LINE ASSEMBLY ON-LINE IF CMSE ON MALET CALL. 
*        21. TWO FORMS EQUATE XXX=NNN OR EQUATE XXX TO NNN ADDED. 
*        22. TIME LIMIT ERR IF TERMINAL AND LINE LIMIT FIXED. 
*        23. DEVICE RETURN AT MALET DROP TIME THRU CVL. 
*        24. SYSRD AND SYSWR RETURN OF STATUS FIXED FOR NOS.
*        25. MSS CSU AND MST COMPILER CODE ADDED. 
*        26. DOCUMENTATION REPLACED WITH CML 3.1 DOCUMENTATION. 
*        27. TERMINAL MODE DETERMINED FROM SYSTEM NOT CALL. 
* 
* 
*         MODSET MAL004KBS CONTAINS ADDITIONAL CHANGES FOR THESE
*         FEATURES WHICH ARE COMMON BETWEEN MALET AND MALET-II. 
* 
* 
* MALET   GLG    78/07/26 
* MALET   KBS    78/07/26 
* 
*         MODSET SUPPORTS MAL003GLG WITH CHANGES COMMON BETWEEN 
*         MALET AND MALET-II
* 
* 
* MALCMP  KBS    78/07/26 
* 
*         MODSET CORRECTS -IF- STATUEMENT CODE GENERATION WHICH 
*         CAUSED ENDLESS LOOP IN PPU
* 
* 
* MALCMP  GLG    78/08/24.
*         MODSET FIXES ERROR ON FORMAT STATEMENT WHERE LAST WORD IS NOT 
*         SUBSTITUTED IF IT EXTENDS TO COL 60.
* 
*                                                                        MAL006G
* MALCMP  GLG    78/08/28.                                               MAL006G
*         MODSET CORRECTS BAD CODE GENERATED IF MSG N N WORDS FROM       MAL006G
*         PN TO LINE.   THE MALET COMPILER FORMS LDN AND COMBINS IT      MAL006G
*         WITH THE REGISTERS ADDRESS WHICH IF MEMORY FORMS BAD CODE.     MAL006G
*                                                                        MAL006G
*                                                                        MAL008K
* MALCMP  KBS    78/09/14                                                MAL008K
* MALET20                                                                MAL008K
* MALET24                                                                MAL008K
* MALETP3                                                                MAL008K
*                                                                        MAL008K
*                CORRECTS REFERENCES TO OFF-LINE PARAMETER               MAL008K
*                REGISTER LOCATIONS                                      MAL008K
*                                                                        MAL008K
*                                                                        MAL009K
* MALCMP  KBS    78/09/14                                                MAL009K
*                                                                        MAL009K
*                CORRECTS PROBLEM WITH P REGISTER VALUE                  MAL009K
*                FOLLOWING A -GOTO XX WHILE...- STATEMENT.               MAL009K
*                                                                        MAL009K
*                                                                        MAL007G
* MALCMP  GLG    78/08/30.                                               MAL007G
*         MODSET CORRECTS PROBLEM WITH PPU DISPLAY AREA BEING            MAL007G
*         USED BY COMPILER AND NOT CLEARED AFTER ITS DONE.               MAL007G
*                                                                        MAL007G
*                                                                        MAL011K
* MALCMP  KBS    78/09/30.                                               MAL011K
*                                                                        MAL011K
*         ADDS COMPILE SUPPORT FOR OFFLINE FORCE ZERO PARITY COMMANDS    MAL011K
*         -FZCP- AND -CHANNEL PE STATUS-                                 MAL011K
*                                                                        MAL011K
*                                                                        MAL010G
* MALETP4 GLG    78/08/08.                                               MAL010G
* MALETP9                                                                MAL010G
*         MODSET ADDS ISOLATION ABLITIES TO 844HT COMPILER CODE          MAL010G
*         MUST BE INSTALLED WITH CORRESPONDING MLD CODE TO FUNCTION      MAL010G
*         CORRECTLY.                                                     MAL010G
*                                                                        MAL010G
*         NEW COMMANDS AS FOLLOWS;                                       MAL010G
*                                                                        MAL010G
*         A. CNTRL A,B,C,D,ABT Z                                         MAL010G
*            CNTRL A,B,C,D,EXECUTE,ABT Z                                 MAL010G
*            CNTRL A,B,C,D,TIME V TO X AND Y,ABT Z                       MAL010G
*            CNTRL A,B,C,D,TIME V X AND Y,ABT Z                          MAL010G
*            CNTRL A,B,C,D,TIME V X Y,ABT Z                              MAL010G
*                                                                        MAL010G
*         B. OUT CH=X,ABT Z                                              MAL010G
*            OUT CHANNEL=X,ABT Z                                         MAL010G
*                                                                        MAL010G
*         C. RES DRIVE FAULT,ABT Z                                       MAL010G
*            RES DRIVE,ABT Z                                             MAL010G
*            RES CONTROLLER,ABT Z                                        MAL010G
*                                                                        MAL010G
*         D. FLAG PULSE CH=X,ABT Z                                       MAL010G
*            FLAG PULSE CHANNEL=X,ABT Z                                  MAL010G
*                                                                        MAL010G
*         E. STATUS CHANNEL,ABT Z                                        MAL010G
*            STATUS GENERAL,ABT Z                                        MAL010G
*            STATUS DETAIL,ABT Z                                         MAL010G
*                                                                        MAL010G
*                                                                        MAL010G
*                                                                        MAL012G
* MALETPA GLG    78/08/08                                                MAL012G
*                                                                        MAL012G
*                ADDS -REFORM- , -SCAN- , AND -WRPRO- STATEMENTS TO      MAL012G
*                FMDFT COMPILER                                          MAL012G
*                                                                        MAL012G
*                                                                        MAL013G
* MALETPD GLG    78/07/24.                                               MAL013G
*         MODSET ADDS COMPILER OVERLAY FOR MSS MSC TO MALET              MAL013G
*         SUPPORTED PRODUCTS.                                            MAL013G
*                                                                        MAL013G
*                                                                        MAL014G
* MALET   GLG    78/10/09.                                               MAL014G
*                                                                        MAL014G
*         CORRECT DOUBLE LINES ON TERMINAL WHEN USING                    MAL014G
*         TWO OUTPUT FILES ON NOS                                        MAL014G
*                                                                        MAL014G
*                                                                        D44001J
* D44     JES    78/07/25                                                D44001J
*         MODSET CORRECTS MODULE D4410 SO THAT IT SHARES THE I/O         D44001J
*         CHANNEL/UNIT MORE EFFECTIVELY WITH THE O/S.                    D44001J
*                                                                        D44001J
*                                                                        D44002J
* D44     JES    78/07/25                                                D44002J
*         MODSET CORRECTS MODULE D4414 SO THAT IT SHARES THE I/O         D44002J
*         CHANNEL/UNIT MORE EFFECTIVELY WITH THE O/S AND PERFORMS        D44002J
*         RANDOM SEEKS ON ALL DEVICE CODES (CURRENTLY ALL SEEKS ARE      D44002J
*         TO CYL 000 FOR DEVICE CODES 2 AND 4).                          D44002J
*                                                                        D44002J
*                                                                        D44003J
* D44     JES    78/07/25                                                D44003J
*         MODSET CHANGES MODULE 17 SO THAT READCW COMMANDS ARE USED TO   D44003J
*         SWEEP THE PACK INSTEAD OF READ COMMANDS.  THIS PREVENTS THE    D44003J
*         TRANSMISSION OF DATA TO THE PPU OUTSIDE THE PREALLOCATED       D44003J
*         AREA IN SITUATIONS WHERE DATA SECURITY IS REQUIRED.  THIS      D44003J
*         MOD ALLOWS MODULE 17 TO EXECUTE AT AN ACCESS LEVEL OF 3        D44003J
*         AFTER THE 844 PRODUCT OVERLAY MODS REQUIRE AN ACCESS LEVEL     D44003J
*         OF 4 TO READ OUTSIDE THE PREALLOCATED AREA.                    D44003J
*                                                                        D44003J
*                                                                        MAL017G
* MALET   JES    78/07/31                                                MAL017G
*         GLG    78/10/13.                                               MAL017G
*         MODSET LOWERS THE CPU PRIORITY FOR MALET UNDER NOS TO          MAL017G
*         DECREASE THE IMPACT ON SYSTEM THRU-PUT.                        MAL017G
*                                                                        MAL017G
*                                                                        T6X001J
* T6X     JES    78/07/25                                                T6X001J
*         MODSET CHANGES ERROR OUTPUT FORMAT OF T6X TO LOOK THE SAME     T6X001J
*         AS T7X TO MAKE IT EASIER FOR THE CE TO MIGRATE FROM ONE        T6X001J
*         TEST TO THE OTHER.                                             T6X001J
*                                                                        T6X001J
*                                                                        T6X002J
* T6X     JES    78/07/25                                                T6X002J
*         MODSET CHANGES THE COMPILE CARDS FOR THE 99 SERIES MODULES OF  T6X002J
*         T6X TO CONFORM TO CODING CONVENTIONS  -  COMPILE,SOURCE        T6X002J
*                                                                        T6X002J
*                                                                        T7X002J
* T7X     JES    78/07/25                                                T7X002J
*         MODSET ALLOWS GCR OPERATIONS ON DEVICE CODE 54 DUE TO THE      T7X002J
*         INABILITY OF CVL TO DETERMINE THE CORRECT DEVICE CODE          T7X002J
*         IN NOSBE.  MODULE T7X00 IS MODIFIED.                           T7X002J
*                                                                        T7X002J
*                                                                        T7X003J
* T7X     JES    78/07/25                                                T7X003J
*         MODSET RELEASES THE I/O CHANNEL DURING LONG DELAY PERIODS      T7X003J
*         IN MODULE T7X21.                                               T7X003J
*                                                                        T7X003J
*                                                                        T7X004J
* T7X     JES    78/07/25                                                T7X004J
*         MODSET CORRECTS FIRST REVERSE START TIME PLOT IN MODULE        T7X004J
*         T7X32.                                                         T7X004J
*                                                                        T7X004J
*                                                                        T7X005J
* T7X     JES    78/07/25                                                T7X005J
*         MODSET COMPENSATES FOR TACH COUNT ERROR OF PLUS 2 IN           T7X005J
*         CONTROLWARE WHEN MEASURING FORWARD OR REVERSE GAPS IN          T7X005J
*         MODULES T7X33 AND T7X34.                                       T7X005J
*                                                                        T7X005J
*                                                                        T7X006J
* T7X     JES    78/07/25                                                T7X006J
*         MODSET CORRECTS MISSING DOCUMENTATION ON MODULE T7X45 WHEN     T7X006J
*         EXTRACTED WITH MLTDOC (BLANK LINE REMOVED).                    T7X006J
*                                                                        T7X006J
*                                                                        T7X007J
* T7X     JES    78/07/25                                                T7X007J
*         MODSET ADDS RUNNING MESSAGE TO T7X45A.                         T7X007J
*                                                                        T7X007J
*                                                                        T7X008J
* T7X     JES    78/07/25                                                T7X008J
*         THIS MODSET ADDS MODULE T7X47, CAPSTAN GO DOWN-TIME TEST, TO   T7X008J
*         THE CONFIDENCE TEST OF T7X.                                    T7X008J
*                                                                        T7X008J
*                                                                        T7X009J
* T7X     JES    78/07/25                                                T7X009J
*         THIS MODSET ADDS MODULE T7X73, SERVO ADJUST, TO THE REPAIR     T7X009J
*         SECTION OF T7X.  THIS MODULE ALLOWS ON-LINE ADJUSTMENT OF      T7X009J
*         THE CAPSTAN SERVO SYSTEM.                                      T7X009J
*                                                                        T7X009J
*                                                                        T7X010J
* T7X     JES    78/07/25                                                T7X010J
*         MODSET ADDS A LINE OF DASHES TO THE END OF AN ERROR OUTPUT     T7X010J
*         MESSAGE BLOCK TO MAKE IT EASIER TO READ.  MODULES T7X985       T7X010J
*         AND T7X986 ARE MODIFIED.                                       T7X010J
*                                                                        T7X010J
*                                                                        T7W002J
* T7W     JES    78/07/25                                                T7W002J
*         MODULE ALLOWS GCR OPERATIONS ON DEVICE CODE 54 DUE TO THE      T7W002J
*         INABILITY OF CVL TO DETERMINE THE CORRECT DEVICE CODE          T7W002J
*         IN NOSBE.  MODULE T7W00 IS MODIFIED.                           T7W002J
*                                                                        T7W002J
*                                                                        T7W003J
* T7W     JES    78/07/25                                                T7W003J
*         MODSET RELEASES THE I/O CHANNEL DURING LONG DELAY PERIODS      T7W003J
*         IN MODULE T7W21.                                               T7W003J
*                                                                        T7W003J
*                                                                        T7W004J
* T7W     JES    78/07/25                                                T7W004J
*         MODSET CORRECTS FIRST REVERSE START TIME PLOT IN MODULE        T7W004J
*         T7W32.                                                         T7W004J
*                                                                        T7W004J
*                                                                        T7W005J
* T7W     JES    78/07/25                                                T7W005J
*         MODSET COMPENSATES FOR TACH COUNT ERROR OF PLUS 2 IN           T7W005J
*         CONTROLWARE WHEN MEASURING FORWARD OR REVERSE GAPS IN          T7W005J
*         MODULES T7W33 AND T7W34.                                       T7W005J
*                                                                        T7W005J
*                                                                        T7W006J
* T7W     JES    78/07/25                                                T7W006J
*         MODSET CORRECTS MISSING DOCUMENTATION ON MODULE T7W45 WHEN     T7W006J
*         EXTRACTED WITH MLTDOC (BLANK LINE REMOVED).                    T7W006J
*                                                                        T7W006J
*                                                                        T7W007J
* T7W     JES    78/07/25                                                T7W007J
*         MODSET ADDS RUNNING MESSAGE TO T7W45A.                         T7W007J
*                                                                        T7W007J
*                                                                        T7W008J
* T7W     JES    78/07/25                                                T7W008J
*         THIS MODSET ADDS MODULE T7W47, CAPSTAN GO DOWN-TIME TEST, TO   T7W008J
*         THE CONFIDENCE TEST OF T7W.                                    T7W008J
*                                                                        T7W008J
*                                                                        T7W009J
* T7W     JES    78/07/25                                                T7W009J
*         THIS MODSET ADDS MODULE T7W73, SERVO ADJUST, TO THE REPAIR     T7W009J
*         SECTION OF T7W.  THIS MODULE ALLOWS ON-LINE ADJUSTMENT OF      T7W009J
*         THE CAPSTAN SERVO SYSTEM.                                      T7W009J
*                                                                        T7W009J
*                                                                        T7W010J
* T7W     JES    78/07/25                                                T7W010J
*         MODSET ADDS A LINE OF DASHES TO THE END OF AN ERROR OUTPUT     T7W010J
*         MESSAGE BLOCK TO MAKE IT EASIER TO READ.  MODULES T7W985       T7W010J
*         AND T7W986 ARE MODIFIED.                                       T7W010J
*                                                                        T7W010J
*                                                                        MAL016G
* MALET   JES    78/07/25                                                MAL016G
*         GLG    78/10/13.                                               MAL016G
*         MODSET ADDS SUPPORT TO A NEW FORM OF THE ASSIGN DIRECTIVE      MAL016G
*         AS FOLLOWS -         ASSIGN MNE=XX                             MAL016G
*         FOR THIS MOD TO BE EFFECTIVE, PPU ROUTINE CVL MUST BE          MAL016G
*         MODIFIED.  THESE MODS ALLOW NON-RMS DEVICES TO BE ASSIGNED     MAL016G
*         TO A MALET JOB VIA REQUEST CARDS IN BATCH MODE.                MAL016G
*                                                                        MAL016G
*                                                                        MAL015G
* MALET   GLG    78/10/13.                                               MAL015G
*         MODSET REDUCES FL FOR MALET BELOW DR REQUIREMENT OF 20K.       MAL015G
*                                                                        MAL015G
*                                                                        T7X011G
* T7X     GLG    78/10/16.                                               T7X011G
*         MODSET CORRECTS COMPILER ERRORS IN MODULE T7X47                T7X011G
*         CAUSED BY CHANGES IN DUP COMMAND FOR CML3.1.                   T7X011G
*                                                                        T7X011G
*                                                                        T7W011G
* T7W     GLG    78/10/16.                                               T7W011G
*         MODSET CORRECTS COMPILER ERRORS IN T7W47 CAUSED                T7W011G
*         BY NEW FORMAT OF DUP COMMAND ON CML3.1.                        T7W011G
*                                                                        T7W011G
* MALETP4 GLG    78/10/25.                                               MAL019G
*         MODSET CORRECTS RETURN JUMP ADDRESSES IN 844 COMPILER TO MATCH MAL019G
*         844HT DRIVER.                                                  MAL019G
*                                                                        MAL019G
*                                                                        MAL020G
* MALET   GLG    78/10/25.                                               MAL020G
*         MODSET CORRECTS MALET TO REQUEST DISK PACK SN ONLY             MAL020G
*         IF ACCESS LEVEL GRANTS WRITE OUTSIDE PRE-ALLOCATED             MAL020G
*         DISK AREA REQUESTED.                                           MAL020G
*                                                                        MAL020G
*                                                                        MAL018K
* MALET11 KBS   78/10/24.                                                MAL018K
*         MODSET CORRECTS PROBLEM WITH BINARY WRITE LENGTH TOO SHORT     MAL018K
*         IF COMPILED WITH CMSE PARAMETER AND THEN DUMPED.               MAL018K
*                                                                        MAL018K
*                                                                        D44004G
* D44     GLG    78/10/30.                                               D44004G
*         MODSET CORRECTS D4402 ERRORS IN COMPARING WORDS                D44004G
*         SB(23) AND SB(24) PLUS D4410 INACCURATLY POSTING               D44004G
*         HUNG BUFFERED CONTROLLER.                                      D44004G
*                                                                        D44004G
*                                                                        MAL008G
* MALET   GLG    78/10/31.                                               MAL008G
*         MODSET  ADDS  NEW  DOCUMENTATION FOR FMD MAINTENANCE FEATURES  MAL008G
*         ADDED TO 844HT, FMDHT, AND FMDFT DRIVERS PLUS  PLACES  CHANGE  MAL008G
*         MARKS  INTO  COLUMN  80  FOR  ALL OTHER CHANGES FOR CML3.0 TO  MAL008G
*         CML3.1 ENHANCEMENTS TO OBTAIN  LISTING  OF  CHANGES  RUN  THE  MAL008G
*         FOLLOWING DECK.                                                MAL008G
*                                                                        MAL008G
*         JOB/USER/CHARGE.   JOB FOR NOS                                 MAL008G
*         RESOURC,MT=1.                                                  MAL008G
*         REQUEST,OLDPL,VSN=CML,HY,MT,F=SI,LB=KU.                        MAL008G
*         UPDATE,Q,D.                                                    MAL008G
*         ATTACH,OPL/UN=LIBRARY                                          MAL008G
*         RFL,77000.                                                     MAL008G
*         COMPASS,I,X,S=NOSTEXT,S=CPUTEXT,S=CETEXT.                      MAL008G
*         7/8/9                                                          MAL008G
*         *ID,DEFINES                                                    MAL008G
*         *DEFINE,NOS,NOS5                                               MAL008G
*         *DEFINE,DOC                                                    MAL008G
*         *COMPILE,MALET                                                 MAL008G
*         6/7/8/9                                                        MAL008G
*                                                                        MAL008G
*                                                                        MAL008G
*         JOB,MT1.USER/CHARGE.   JOB FOR NOSBE                           MAL008G
*         REQUEST,OLDPL,VSN=CML,HY,MT.                                   MAL008G
*         UPDATE,Q,D.                                                    MAL008G
*         RFL,77000.                                                     MAL008G
*         COMPASS,I,S=SCPTEXT.                                           MAL008G
*         7/8/9                                                          MAL008G
*         *ID,DEFINES                                                    MAL008G
*         *DEFINE,NOSBE,NOSBE4                                           MAL008G
*         *DEFINE,DOC                                                    MAL008G
*         *COMPILE,MALET                                                 MAL008G
*         6/7/8/9                                                        MAL008G
*                                                                        MAL008G
*                                                                        INS001G
* INSTLDKS       GLG         78/11/01.                                   INS001G
*         MODSET CORRECTS INSTLDKS TO FUNCTION CORRECTLY ON CML 3.1.     INS001G
*                                                                        INS001G
*                                                                        TIO001K
* TIO     KBS    78/11/20.                                               TIO001K
*                                                                        TIO001K
*         CORRECTS ILLEGAL MEMORY REQUEST UNDER CMM                      TIO001K
*         REPORTED IN PSR DIG0179.                                       TIO001K
*                                                                        TIO001K
*                                                                        TIO000K
* TIO     KBS    78/11/17.                                               TIO000K
*                                                                        TIO000K
*         CORRECTS UNDEFINED SYMBOL REFERENCE REPORTED                   TIO000K
*         IN DPSR 022929.                                                TIO000K
*                                                                        TIO000K
*                                                                        TFE001G
* TFE     GLG    78/12/20.                                               TFE001G
*         MODSET CORRECTS ASSEMBLY ERRORS IN MODULE TFE04 CAUSED         TFE001G
*         BY NEW MALET FEATURES. PROBLEM REPORTED BY PTR VER1021.        TFE001G
*                                                                        TFE001G
*                                                                        MAL022G
* ASSYTAG GLG    78/12/05.                                               MAL022G
*         MODSET ADDS NOS5 AND NOSBE5 DEFINITIONS TO ASSYTAG.            MAL022G
*                                                                        MAL022G
*                                                                        MAL023G
* MALETPB GLG    79/01/09.                                               MAL023G
* MALETPC ADD SEEK RESERVE AND SEEK RELEASE TO MSS PRODUCT               MAL023G
*         OVERLAYS CSU AND MST.                                          MAL023G
*                                                                        MAL023G
*                                                                        CSU000G
* CSU     GLG    79/01/26.                                               CSU000G
*         MODSET ADDS SEEK RESERVE INTO CSU01.                           CSU000G
*                                                                        CSU000G
*                                                                        MST000G
* MST     GLG    79/01/26.                                               MST000G
*         MODSET ADDS SEEK RESERVE INTO MST01.                           MST000G
*                                                                        MST000G
*                                                                        MAL024G
* MALET30 GLG    79/02/01.                                               MAL024G
*         MODSET MOVE THE OPEN OF THE INPUT FILE FROM BEFORE LO          MAL024G
*         PARAMETERS ARE CRACKED TO AFTER. CODE IN RESPONSE TO PTR       MAL024G
*         CML31-18.                                                      MAL024G
*                                                                        MAL024G
*                                                                        MAL025G
* MALET   GLG    79/02/01.                                               MAL025G
*         MODSET CORRECTS DOCUMENTATION ON MSG COMMAND AND DELETES       MAL025G
*         UPDATE IF CODE FOR DOCUMENTATION AND CHANGES IT TO COMPASS     MAL025G
*         IF CODE.  CODE IN RESPONSE TO PTR CML31-7.                     MAL025G
*                                                                        MAL025G
*                                                                        MAL026G
* MALET   GLG    79/02/01.                                               MAL026G
* MALET12 MODSET CHANGES N.GO/DROP MESSAGES TO FLASH FOR OPERATOR        MAL026G
*         TO NOTICE THEM.  MODSET IN RESPONSE TO DPSR 32020.             MAL026G
*                                                                        MAL026G
*                                                                        MAL028G
* MALET   GLG    79/02/05.                                               MAL028G
* MALET11 MODSET CORRECTS MALET TO NOT RETURN DEVICE IF NOT IN  EST      MAL028G
*         BIT SET.                                                       MAL028G
*                                                                        MAL028G
*                                                                        D44005G
* D44     GLG    78/11/10.                                               D44005G
*         MODSET CORRECTS D44 TO RUN ON THE FMD/844.  MODULE D4402       D44005G
*         NEEDED TO BE CORRECTED.                                        D44005G
*                                                                        D44005G
*                                                                        R2D2550
* HPA    RAZ    02/01/79                                                 R2D2550
*        THIS MODSET ADDS THE FOLLOWING FEATURES TO THE 2550 REPORTS     R2D2550
*         1) ADD GRAPH ROUTINE TO OVERLAY 3                              R2D2550
*         2) ADD CALLS TO GRAPH ROUTINE FOR 2550 REPORTS                 R2D2550
*         3) ADD 80 COLUMNS OPTION TO 2550 REPORT                        R2D2550
*                                                                        R2D2550
*                                                                        R2FSCR 
*        R2FSCR                                                          R2FSCR 
* HPA    JPD    02/01/79                                                 R2FSCR 
*     THIS CORRECTION SET MAKES THE C176 REPORTS 80 COLUMNS              R2FSCR 
*     AND CORRECTS OTHER PROBLEMS.                                       R2FSCR 
*        1. TOTAL ERRORS IN ANALYSIS AND DETAIL REPORTS AREN'T THE       R2FSCR 
*           SAME.                                                        R2FSCR 
*        2. SECOND PAGE HEADER DIDN'T COME OUT IN ANALYSIS REPORT.       R2FSCR 
*        3. CHANNEL PE'S CHANNEL WAS NOT CORRECT.                        R2FSCR 
*        4.ADDS THE LCME THRESHOLD COUNT MESSAGE TO THIS REPORT.         R2FSCR 
*                                                                        R2FTAPE
*        R2FTAPE                                                         R2FTAPE
*HPA     REF          11/17/78                                           R2FTAPE
*                                                                        R2FTAPE
*        THIS FEATURE CODE DOES THE FOLLOWING:                           R2FTAPE
*        1) PUT ALL PROCESSING OF TAPE MESSAGES IN ROUTINES              R2FTAPE
*           AN3MT3 AND DL3MT3 REMOVING ROUTINES AN3NT3 AND               R2FTAPE
*           DL3NT3.                                                      R2FTAPE
*                                                                        R2FTAPE
*        2) REFORMATS THE TAPE DETAILED REPORT TO INCLUDE CHANNEL        R2FTAPE
*           NUMBER AND DATE IN DETAIL LINE, AND THE CONTROLLER           R2FTAPE
*           TYPE IN THE HEADER LINE.                                     R2FTAPE
*                                                                        R2FTAPE
*        3) ADDS THE 80 COLUMN PARAMETER TO TAPE REPORTS.                R2FTAPE
*                                                                        R2FTAPE
*        4) CORRECTS BUGS AFFECTING READ/WRITE STATUS, WRITE-EST         R2FTAPE
*           AND CONTROLLER TYPE FOR 60X/65X UNITS.                       R2FTAPE
*                                                                        R2FTAPE
*        5) CORRECTS VR AND DR INPUT PARAMETERS.                         R2FTAPE
*                                                                        R2FTAPE
*        6) REFINES THE ATS INTERVENTION REPORT.                         R2FTAPE
*                                                                        R2FTAPE
*                                                                        R2FHWMO
*        R2FHWMOD                                                        R2FHWMO
* HPA    REF    02/01/79                                                 R2FHWMO
*        THIS FEATURE CODE ADDS THE FOLLOWING:                           R2FHWMO
*         1) ADD THE HW - HISTORY WINDOW PARAMETER                       R2FHWMO
*         2) PUTS 3 DIGIT EST ORDINALS IN TAPE MEDIA                     R2FHWMO
*            REPORTS IN RESPONSE TO DPSR 33237.                          R2FHWMO
*         3) UPDATE HPERS DOCUMENTATION                                  R2FHWMO
*         4) ADD ROUTINE JULE TO OVERLAY 0.                              R2FHWMO
*         5) CLEAN UP CODE IN HPA9 AND PUT TAPE MEDIA                    R2FHWMO
*            REPORT IN 80 COLUMNS.                                       R2FHWMO
*         6) ADD ERROR COUNT TO TAPE MEDIA REJECTION LIST                R2FHWMO
*                                                                        R2FHWMO
*                                                                        HPA405S
* HPA    SHS    01/20/79                                                 HPA405S
*        THIS MODSET FIXES A PROBLEM WITH THE METHOD THAT ROUTINE        HPA405S
*        PARMS WAS STUFFING THE FILE NAMES INTO THE FITS.                HPA405S
*                                                                        HPA405S
*        ALSO ADDED IS A CALL TO CPYFTN TO INSERT THE COPYRIGHT          HPA405S
*        DATE INTO HPA BINARY.                                           HPA405S
*                                                                        HPA405S
*        MISC FIXES TO MINOR BUGS FOUND LOCALLY                          HPA405S
*                                                                        HPA405S
*                                                                        R2FECS 
*        R2FECS                                                          R2FECS 
*                                                                        HPA31C1
* HPA2,HPA36     JPD     79/10/16                                        HPA31C1
*         MODSET ENHANCES THE ECS REPORTING BY:                          HPA31C1
*         1. 80 COLUMN REPORT FORMAT                                     HPA31C1
*         2. BLANKING FIELDS THAT DON'T HAVE MEANINGFUL DATA (0'S)       HPA31C1
*         3. COUNTING THE NUMBER OF 1 WORDS READS                        HPA31C1
*         4. COMBINE UP TO 3 SEF'S (FROM NOS) INTO ONE                   HPA31C1
*            (SUBROUTINE POST2)                                          HPA31C1
*         5. FIX SEVERAL OTHER BUGS IN ORIGINAL CODE                     HPA31C1
*                                                                        HPA31C1
*         R2DFMD                                                         HPA31C1
*                                                                        HPA31C1
* HPA    JPD    02/01/79                                                 R2FECS 
*        THIS MODSET ADDS FMD SUPPORT TO THE 844 REPORT ROUTINES         R2FECS 
*        PLUS MAKING THE FOLLOWING ENHANCEMENTS:                         R2FECS 
*         1) PUT IN 80 COLUMN REPORTS FOR DISK.                          R2FECS 
*         2) PUT IN THE -R- PARAMETER TO SELECT 80 COLUMN REPORTS        R2FECS 
*         3) REWRITE THE DISK POSITION ANALYSIS SECTION OF THE           R2FECS 
*            DISK ANALYSIS REPORT.                                       R2FECS 
*         4) FORCE A DETAIL REPORT IF AN EXTENDED DETAIL REPORT          R2FECS 
*            IS SELECTED ON THE HPA CALL.                                R2FECS 
*                                                                        R2FECS 
*                                                                        CPYMOD7
* CPYFTN  SHS   01/20/79                                                 CPYMOD7
* CPYCOM                                                                 CPYMOD7
*         ADD 1979 TO FORTRAN COPYRIGHT COMMON DECK ON CML PL.           CPYMOD7
*         ADD 1979 TO COMPASS COPYRIGHT COMMON DECK ON CML PL.           CPYMOD7
*                                                                        CPYMOD7
*                                                                        VERR2G 
* HPA    SHS      02/01/79                                               VERR2G 
*        THIS MODSET CHANGES THE VERSION LEVEL OF HPA                    VERR2G 
*        TO HPAV4/R2G TO IDENTIFY FEATURE CODE MODSETS                   VERR2G 
*        ADDED FOR CMLV3.1.                                              VERR2G 
*                                                                        VERR2G 
*                                                                        MAL032G
* MALET11 GLG    79/02/13.                                               MAL032G
*         MODSET CORRECTS BIT 2**5 FROM BEING TRANSMITTED TO MLD         MAL032G
*         FOR A CHANNEL THAT HAS BEEN DOWNED.                            MAL032G
*                                                                        MAL032G
*                                                                        R2FCYB 
* HPA    GAS    79/02/22                                                 R2FCYB 
*                                                                        R2FCYB 
* R2FCYB IS A FEATURE WHICH ADDS CYBERAMA CAPABILITY TO HPA.             R2FCYB 
*        ADD A CONFIGURATION EDITOR (HPA,HPA4,HPA5,HPA8)                 R2FCYB 
*        ADD SHR TYPE RECORDS (40,41,42,43) TO ACCUMULATE                R2FCYB 
*        SYSTEM EVENT TIME DATA AS INPUT BY OPERATOR,                    R2FCYB 
*        (HPA,HPA3,HPA4,HPA6,HPA8).                                      R2FCYB 
*        ADD NEW ERROR TYPES (550B-611B).                                R2FCYB 
*                                                                        R2FCYB 
*                                                                        INS002G
* INSTLDKS GLG   79/02/13.                                               INS002G
*         MODSET ADDS INSTALL DECK FOR NOS4 AND NOSBE4 TO CML3.1         INS002G
*         MODSET CORRECTS INSTALL DECK FOR NOSBE5.                       INS002G
*                                                                        INS002G
*                                                                        MLT000R
* MLTDOC  RAS    78/12/22                                                MLT000R
*         THIS MODSET ADDS THE SOURCE LINE NUMBERS TO MALET MODULES      MLT000R
*         IN THE INTERNAL DOCUMENTATION GENERATED BY MLTDOC.             MLT000R
*         MODSET IN RESPONSE TO DPSR 31081.                              MLT000R
*                                                                        MLT000R
*                                                                        MLT000R
*                                                                        MAL029K
* MALET   KBS    79/02/06.                                               MAL029K
* MALCMP                                                                 MAL029K
*                                                                        MAL029K
*         CORRECTS DOCUMENTATION FOR CHANNEL AND FZCP COMMANDS.          MAL029K
*         CORRECTS ERROR MESSAGE ISSUED WHEN CHANNEL OR FZCP             MAL029K
*         STATEMENT IS ENCOUNTERED WHEN -CMSE- NOT SELECTED ON           MAL029K
*         MALET CALL. SATISFIES PTRS CML31-11 AND CML31-12.              MAL029K
*                                                                        MAL029K
*                                                                        MAL030K
* MALCMP  KBS    79/02/07.                                               MAL030K
*                                                                        MAL030K
*         CORRECTS DISPLAY OF ILLEGAL CHARACTERS IN ALPHA SUBSTITUTION   MAL030K
*         REPORTED IN PTR CML31-14.                                      MAL030K
*                                                                        MAL030K
*                                                                        MAL031K
* MALET   KBS    79/02/12.                                               MAL031K
* MALETP0                                                                MAL031K
*                                                                        MAL031K
*         CORRECTS DOCUMENTATION OF TIMEOUT COMMAND AND FIXES            MAL031K
*         COMPILER HANDLING OF CONSTANTS IN X/Y DELAY FORMAT.            MAL031K
*         PROBLEMS REPORTED IN PTRS CML31-15 AND CML31-17.               MAL031K
*                                                                        MAL031K
*                                                                        MAL027K
* MALET12 KBS    79/01/08.                                               MAL027K
*                                                                        MAL027K
*         CORRECTS PROBLEM IN SYSRD AND SYSWR BUFFER LENGTHS             MAL027K
*         REPORTED IN PSR DIMA170.                                       MAL027K
*                                                                        MAL027K
*                                                                        T7X012G
* T7X     GLG    79/02/26.                                               T7X012G
*         MODSET DELETES REFERENCES TO MALET FROM T7X FOR OFF-LINE       T7X012G
*                                                                        T7X012G
*                                                                        MAL033G
* MALET   GLG    79/02/27.                                               MAL033G
*         MODSET ADDS DOCUMENTATION ON FMD AND MSS TO TABLE 5-1          MAL033G
*         IN RESPONSE TO PTR CML31-19.                                   MAL033G
*                                                                        MAL033G
*                                                                        T6X003G
* T6X     GLG    79/03/05.                                               T6X003G
*         MODSET DELETES EXIT FROM T6X202 TO T6X30. IN RESPONSE TO       T6X003G
*         DPSR 030849.                                                   T6X003G
*                                                                        T6X003G
*                                                                        HPA407S
*        DPSR 33285,  DIG0186                                            HPA407S
* HPA    SHS      03/05/79                                               HPA407S
*                                                                        HPA407S
*        CORRECTIVE CODE TO ADD PROCESSING FOR UNUSED BITS 4,38,39       HPA407S
*        OF THE CY170 SCR.  PREVIOUSLY, IF BITS 38 AND 39 WERE SET,      HPA407S
*        HPA WOULD GET A FORTRAN ERROR 1.                                HPA407S
*                                                                        HPA407S
*        CORRECT MODULE TABLE ON CY176 REPORT                            HPA407S
*                                                                        HPA407S
*                                                                        MAL034G
* MALET   GLG    79/03/05.                                               MAL034G
*         MODSET ADDS DOCUMENTATION TO ERS ON MLD, SBP AND CVL           MAL034G
*         ERROR MESSAGES.                                                MAL034G
*                                                                        MAL034G
*                                                                        INS003G
* INSTLDKS GLG   79/03/13.                                               INS003G
*         MODSET CORRECTS ASSEMBLY ERRORS IN REGEN DUE TO                INS003G
*         S=CPCTEXT NOT BEING ON INSTALLATION DECK.                      INS003G
*                                                                        INS003G
*                                                                        MAL035G
* MALET   GLG    79/03/15.                                               MAL035G
*         MODSET CORRECTS ERS DOCUMENTATION FOR ERROR MESSAGE            MAL035G
*         DEVICE CODE/STATUS MISMATCH  WHICH IS RECEIVED FOR             MAL035G
*         ILLEGAL 844 UNIT ASSIGNED ON AN FMD CONTROLLER. PTR            MAL035G
*         VER1074 DESCRIBES PROBLEM. DOCUMENTATION FOR CONTROL           MAL035G
*         AND OUT COMMANDS WAS ALSO CORRECTED WITH MODSET.               MAL035G
*                                                                        MAL035G
*                                                                        HPA401R
* HPA     RAZ     3/16/79                                                HPA401R
*         THIS MODSET PRODUCES A DETAIL REPORT FROM MAINTENCE            HPA401R
*         REGISTER DATA                                                  HPA401R
*                                                                        HPA401R
*                                                                        HPA403J
* HPA     JPD     3/16/79                                                HPA403J
*         THIS MODSET CORRECTS PROBLEMS IN THE REPORTING OF THE          HPA403J
*         M2 MEMORY.                                                     HPA403J
*                                                                        HPA403J
*                                                                        R2GCYB 
* HPA     GAS    79/03/05.                                               R2GCYB 
*         MODSET R2GCYB CORRECTS MISCELLANEOUS PROBLEMS                  R2GCYB 
*          IN THE CODE OF IDENTIFIER R2FCYB.                             R2GCYB 
*                                                                        HPA401J
* HPA      JLP    03/19/79                                               HPA401J
*          SPEED UP DISK SURFACE ERROR ANALYSIS                          HPA401J
*                                                                        HPA401J
*                                                                        HPA401R
* HPA     REF    03/16/79                                                HPA401R
*         MODSET CONTAINS FEATURE CODE TO DELETE THE PAGE HEADER         HPA401R
*         REPORT NAME IF R (R = REMOTE-OUT) PARAMETER SPECIFIED.         HPA401R
*         IF X = REG (REG = REGRESSION TEST) OR TO PRINT ONLY THE        HPA401R
*                                                                        HPA401R
*                                                                        INS001R
* INSTLDKS RAZ     03/15/79                                              INS001R
*          THIS MOD WILL ADD THE COMPILE CARDS FOR HPA38 AND HPA7        INS001R
*          TO THE INSTALLATION DECKS FOR THE NOS AND NOS/BE SYSTEMS.     INS001R
*                                                                        INS001R
*                                                                        MAL036G
* MALET   GLG    79/04/01.                                               MAL036G
* MALET20 MODSET ADDS ABBREVIATIONS FOR COMPILE DIRECTIVE PARAMETERS     MAL036G
* MALCMP  SOURCE AND LIST OPTIONS AS S AND L.  DPSR 34103.               MAL036G
*                                                                        MAL036G
*                                                                        MAL037G
* MALET   GLG    79/04/04                                                MAL037G
*         MODSET ADDS EXAMPLES OF DATA STATEMENT FOR HEX DATA.           MAL037G
*                                                                        MAL037G
*                                                                        T6X004J
* T6X     JES    79/01/25                                                T6X004J
*         MODSET CORRECTS A DOCUMENTATION ERROR IN MODULE T6X09.         T6X004J
*         EC 246 IS DEFINED WHEN IT SHOULD BE EC 245.                    T6X004J
*                                                                        T6X004J
*                                                                        T6X005J
* T6X     JES    79/01/25                                                T6X005J
*         MODSET CORRECTS A PROBLEM IN PARAMETER CRACKING MODULE         T6X005J
*         T6X98P.  SINCE THIS MODULE DOES NOT VERIFY THE CONTENTS OF     T6X005J
*         PARAMETER REGISTER P2 (WORD COUNT), A PRODUCT OVERLAY ERROR    T6X005J
*         (BUFFER INDEX OR WC ERROR) IS DETECTED WHICH IS MIS-LEADING    T6X005J
*         TO THE CE IF P2 IS LEFT SET TO 0000.                           T6X005J
*         TO THE CE IF P2 IS LEFT SET TO 0000. DPSR 031064 RESPONSE.     T6X005J
*                                                                        T6X005J
*                                                                        T6X006J
* T6X     JES    79/01/25                                                T6X006J
*         MODSET CORRECTS A PROBLEM IN MODULE T6X981 THAT OCCURS WHEN    T6X006J
*         EXECUTING T6X FROM A TERMINAL. IF A 66X UNIT DROPS READY OR    T6X006J
*         DOES NOT HAVE A WRITE RING. T6X EXECUTION STOPS WITH NO ERROR  T6X006J
*         MESSAGE TO THE TERMINAL (JUST A QUESTION MARK).                T6X006J
*                                                                        T6X006J
*                                                                        MAL041G
* MALET10 GLG    79/04/13.                                               MAL041G
*         MODSET CHANGES DISPLAY FOR DEVICE CODES TO INCLUDE             MAL041G
*         7155 (FMD) CONTROLLER ON DEVICE CODE FIVE WITHIN               MAL041G
*         THE DEVICES DISPLAY.                                           MAL041G
*                                                                        MAL041G
*                                                                        MAL042G
* MALET30 GLG    79/04/13.                                               MAL042G
*         MODSET CORRECTS MALET30 TO NOT READ INPUT                      MAL042G
*         IF NOSBE.  MODSET MAL024GLG SHOULD HAVE INCLUDED               MAL042G
*         UPDATE IF CODE ON *READ* MACRO FOR NOS.                        MAL042G
*                                                                        MAL042G
*                                                                        MAL043G
* MALET   GLG    79/04/13.                                               MAL043G
*         MODSET CORRECTS DOCUMENTATION ON COMPARE COMMAND.              MAL043G
*                                                                        MAL043G
*                                                                        MAL040G
* MALET   GLG    79/04/13.                                               MAL040G
*         MODSET CORRECTS PRINT ROUTINE TO ENABLE LONG                   MAL040G
*         LINES IF ON A TERMINAL.  CURRENTLY IF TERMINAL                 MAL040G
*         IS USED THE PRINT LINE IS SPLIT INTO TWO LINES                 MAL040G
*         EVEN IF TERM=132 ON MALET CALL CARD.                           MAL040G
*                                                                        MAL040G
*                                                                        MAL039G
* MALET11 GLG    79/04/13.                                               MAL039G
*         MODSET DELETES UNUSED CODE IN CEVAL ROUTINE                    MAL039G
*         THAT HANDLED SN IN REQUIRED.  MODSET ALSO ADDS                 MAL039G
*         CODE TO REDUCE CVL CALLS IF AL WAS PROVIDED ON                 MAL039G
*         ASSIGN DIRECTIVE.                                              MAL039G
*                                                                        MAL039G
*                                                                        MAL038G
* MALET   GLG    79/04/13.                                               MAL038G
*         MODSET CORRECTS EREXIT AND RECOVR PROCESSING FOR               MAL038G
*         NOS AND NOSBE SO EQUIPMENT WILL BE RETURNED.                   MAL038G
*                                                                        MAL038G
*                                                                        HPA401J
* HPA4    JRJ     79/04/13.                                              HPA401J
*         MODSET ADDS INTERACTIVE COMMAND  "XMIT"                        HPA401J
*         WHICH SETS FROG(19) "ON".                                      HPA401J
*         FROG(19) IS NOW SET TO INDICATE THAT A TRANSMISSION FILE       HPA401J
*         FOR CENTRAL SITE IS NOW TO BE CREATED DURING THIS RUN.         HPA401J
*                                                                        HPA401J
*                                                                        HPA401T
* HPA                                                                    HPA401T
*        CORRECT OVERLAY 3 AND 4 TO GENERATE SHR31 TO SHR35              HPA401T
*        FOR CYBERAMA PROMPTER MESSAGES.                                 HPA401T
*                                                                        HPA401T
*        ADD VARIOUS FIXES TO CYBERAMA CODE                              HPA401T
*                                                                        HPA401T
*                                                                        HPA404R
* HPA      79/04/20                                                      HPA404R
*       ADD SITE MANAGEMENT REPORTS IN OVERLAY 7                         HPA404R
*                                                                        HPA404R
*                                                                        HPA402R
*         DPSR 026257                                                    HPA402R
* HPA     REF    04/13/79                                                HPA402R
*         MODSET REMOVES SECTION OF ANALYSIS REPORTS WHICH GIVE          HPA402R
*         ERROR STATISTICS BY JOB NAME.  CODE REMOVED FROM FOLLOWING     HPA402R
*         ROUTINES IN OVERLAY 3: ERDIST3, INISET3 AND STOJN3.            HPA402R
*         COMMON AREA IKD MODIFIED.                                      HPA402R
*                                                                        HPA402R
*                                                                        MLT001R
* MLTDOC  RAS    79/01/23.                                               MLT001R
*         THIS MODSET CORRECTS A PROBLEM WHICH WAS DETECTED              MLT001R
*         AFTER MODSET MLT000RAS WAS INSERTED.                           MLT001R
*         MLTDOC DOES NOT TEST FOR *END* STATEMENT PROPERLY.             MLT001R
*         PRESENTLY, MLTDOC WILL NOT DETECT AN *END STATEMENT IF         MLT001R
*         A STATEMENT NUMBER IS INCLUDED IN COLUMNS 1 AND/OR 2.          MLT001R
*         THE *ENDSUB* STATEMENT WILL ALSO BE TREATED AS AN *END*        MLT001R
*         IF THERE IS NO STATEMENT NUMBER IN COLUMNS 1 AND/OR 2.         MLT001R
*                                                                        MLT001R
*                                                                        D44006G
* D44     GLG    79/04/13.                                               D44006G
*         MODSET CORRECTS DOCUMENTATION ON D4417 TO INDICATE             D44006G
*         ACCESS LEVEL REQUIRE. DPSR 008935 REPORTED PROBLEM.            D44006G
*                                                                        D44006G
*                                                                        T7X013G
* T7X     GLG    79/04/18.                                               T7X013G
*         MODSET CORRECTS T7X012GLG WHICH ADDED CMSE17X UPDATE           T7X013G
*         *IF CODE WITHOUT A CARD COUNT ON THE *IF.                      T7X013G
*                                                                        T7X013G
*                                                                        HPA404J
*         DPSR11331                                                      HPA404J
* HPA     JPD    5/1/79                                                  HPA404J
*         MODSET CORRECTS BOARD ISOLATION PROBLEM IN THE                 HPA404J
*         CYBER 176 SCR DETAIL REPORT.                                   HPA404J
*         THE BOARD WAS ONLY INCORRECT WHEN THE SYNDROM BITS             HPA404J
*         WERE SET.  MODSET ALSO CORRECTS ANOTHER SYNDROM PROBLEM.       HPA404J
*                                                                        HPA404J
*                                                                        MAL044G
* MALETP9 GLG    79/04/23.                                               MAL044G
*         MODSET CORRECTS OFF-LINE COMPILER TO BE ABLE TO                MAL044G
*         ASSEMBLE MSS PROGRAMS.                                         MAL044G
*                                                                        MAL044G
*                                                                        MST001G
* MST     GLG    79/05/02.                                               MST001G
*         MODSET CORRECTS THE ABORT ADDRESS ON THE SEEK RESERVE          MST001G
*         IN MODULE MST01.                                               MST001G
*                                                                        MST001G
*                                                                        CSU001G
* CSU     GLG    79/04/23.                                               CSU001G
*         MODSET CHANGES DEVICE CODE (DC) REQUIRED FOR CSU FROM          CSU001G
*        102B AND 103B TO 100B AND 101B.                                 CSU001G
*                                                                        CSU001G
*                                                                        HPA408S
* HPA                                                                    HPA408S
*         CORRECTS PARAMETER USAGE AND ADDS                              HPA408S
*         VARIOUS FIXES TO SITE MANAGEMENT CODE                          HPA408S
*                                                                        HPA408S
*                                                                        HPA403R
* HPA     REF    05/11/79                                                HPA403R
*         MODSET CONTAINS CODE FOR 3 ENHANCEMENTS/CORRECTIONS:           HPA403R
*         1) ADDS THE CONTROLLER # TO AN INTERVENTION REPORT MESSAGE.    HPA403R
*         2) INCREASES THE TAPE DETAIL REPORT BLOCK COUNT TO 6 CHARS.    HPA403R
*         3) CORRECTS THE R/W BLOCK COUNT FOR TAPE CUMULATIVE STATUS.    HPA403R
*                                                                        HPA403R
*                                                                        HPA405R
* HPA                                                                    HPA405R
*        CORRECTS DEFICIENCIES IN SITE MANAGEMENT CODE                   HPA405R
*                                                                        D44007J
* D44     JES    79/03/30                                                D44007J
*         MODSET MODIFIES MODULE D4404 (SEEK TEST) TO USE STANDARD       D44007J
*         REGISTERS SO THAT THE COMMON ERROR PROCESSOR CAN BE CALLED.    D44007J
*         A SEEK TIME TOO LONG ERROR MESSAGE IS ALSO ADDED. DPSR 31049.  D44007J
*                                                                        D44007J
*                                                                        D44008J
* D44     JES    79/03/30                                                D44008J
*         MODSET MODIFIES MODULE D4405 (READ FLAW MAPS) TO USE STANDARD  D44008J
*         REGISTER VALUES SO THAT THE COMMON ERROR PROCESSOR CAN BE      D44008J
*         CALLED.  COMPARE ERROR MESSAGES ARE ALSO ADDED. DPSR 31050.    D44008J
*                                                                        D44008J
*                                                                        D44010J
* D44     JES    79/03/30                                                D44010J
*         MODSET REPLACES MODULES D44991 - D44997 WITH A SINGLE MODULE,  D44010J
*         D4499A WHICH IS A SHORT DESCRIPTION OF THE MODULES THAT MAKE   D44010J
*         UP D44. DPSR 31008.                                            D44010J
*                                                                        D44010J
*                                                                        D44011J
* D44     JES    79/05/01                                                D44011J
*         MODSET CORRECTS PROBLEM IN D44 MODULES 40,42,43,44,45 AND      D44011J
*         46 WHERE, DUE TO A CODING ERROR, THE ERROR COUNT IS NEVER      D44011J
*         INCREMENTED EVEN IF ERRORS ARE OCCURRING IF A SCOPE LOOP       D44011J
*         IS SELECTED DPSR 31012.                                        D44011J
*                                                                        D44011J
*                                                                        MAL045K
* MALCMP  KBS    79/06/08.                                               MAL045K
*                                                                        MAL045K
*                RESTORES OPERATION OF *3H FORMAT SPECIFICATION.         MAL045K
*                                                                        MAL045K
*                                                                        T5X000G
* T5X     GLG    79/05/11.                                               T5X000G
*         MODSET CORRECTS ASSEMBLY ERRORS IN T5X FOR CML 3.1 RELEASE     T5X000G
*         CAUSED BY CHANGES IN DUP COMMAND AND OVERFLOW ERRORS.          T5X000G
*                                                                        T5X000G
*                                                                        D44009J
* D44     JES    79/03/30                                                D44009J
*         MODSET REPLACES THE CURRENT ERROR PROCESSOR MODULES WITH A     D44009J
*         NEW PROCESSOR THAT PROVIDES MORE ERROR INFORMATION IN FEWER    D44009J
*         OUTPUT LINES.  THIS NEW PROCESSOR INCLUDES AN ANALYSIS OF      D44009J
*         GENERAL/DETAIL STATUS TO PROVIDE THE USER WITH THE MOST        D44009J
*         SERIOUS PROBLEM DETECTED IN STATUS. CORRECTS D44 FOR           D44009J
*         DPSR 31007.                                                    D44009J
*                                                                        D44009J
*                                                                        FMU002A
* FMU002ALJ  ALJ  79/06/12                                               FMU002A
*      MODSET CORRECTS FMU MODULE 15 TO WAIT FOR NOT BUSY                FMU002A
*      STATUS BEFORE EXECUTING THE PICTURE COMMAND AND RESERVE           FMU002A
*      DRIVE AFTER EXECUTING THE PICTURE COMMAND. DPSR 34824.            FMU002A
*                                                                        FMU002A
*  HPA   RAH 79/06/13                                                    HPA406R
*        THIS MOD CORRECTS TRANSMITTAL PROBLEMS                          HPA406R
*                                                                        HPA406R
*                                                                        HPA406R
*     DECK HPA402JRJ    JRJ    79/06/11                                  HPA402J
*                                                                        HPA402J
*     THIS CORRECTION SET ADDS THE INSERT=H/S COMMAND                    HPA402J
*     ADDS THE INCOMPLETE SUBROUTINE CHANG4 FOR THE                      HPA402J
*     CHANGE=DETAIL COMMAND,                                             HPA402J
*     DELETES ONE SUBROUTINE : PRID4                                     HPA402J
*     CHANGES THE EFFECT OF THE DELETE COMMAND TO SETTING                HPA402J
*     A FLAG FOR LATER DELETION OF A HARDWARE OR SOFTWARE ITEM           HPA402J
*     ADDS DOCUMENTATION IN VARIOUS PLACES                               HPA402J
*                                                                        HPA402J
*  HPA   TEF  79/06/11                                                   HPA402T
*        ADDS CODE TO GENERATE SHR TYPE 40                               HPA402T
*        ELIMINATES REDUNDANT FIRMWARE REVISION AND DISK PACK MOUNTS     HPA402T
*        CORRECTS USE OF SEFREC FOR NOS AND NOS/BE COMPATABILITY         HPA402T
*        CORRECTS CONDITION CAUSING RECORD MANAGER ERROR BY FORTRAN      HPA402T
*                                                                        HPA402T
*                                                                        HPA402T
*                                                                        ATC012K
* CAUTIONS KES   79/06/15.                                               ATC012K
*         MODSET ADDS CAUTIONS COMMENT FOR ATC32 WHICH DOES              ATC012K
*         NOT FULLY TEST FUNCTION 50. WHEN FCO AVAILABLE                 ATC012K
*         ATC32 WILL BE CORRECTED AND CAUTIONS COMMENT RE-               ATC012K
*         MOVED. PROBLEM IS DUE TO HARDWARE ERROR.                       ATC012K
*                                                                        ATC012K
*                                                                        FMU001A
*FMU001ALJ  ALJ  79/05/17.  DPSR  034823                                 FMU001A
*     MODSET CORRECTS MODULE FMU16 WHEN                                  FMU001A
*     RUNNING AT 2X SPEED.                                               FMU001A
*                                                                        FMU001A
*                                                                        D44012J
* D44     JMO    79/05/18                                                D44012J
*         MODSET CORRECTS CRACKING OF PARAMETERS TO ALLOW PROPER         D44012J
*         ACCESS LEVEL FOR READS AND WRITES WITHIN PART II               D44012J
*         MODULES. MODSET IS CODE FOR DPSR 32001.                        D44012J
*                                                                        D44012J
*                                                                        D44014J
*D44      JMO    79/06/15.                                               D44014J
*         MODSET CORRECTS TEMP ERROR FOR FMD CONTROLLERS.                D44014J
*         DPSR 33256.                                                    D44014J
*                                                                        D44014J
*                                                                        D44015J
*D44      JMO    79/06/26                                                D44015J
*         MODSET CORRECTS SEC/TRK COUNT ON WRITE VERIFY ERROR            D44015J
*         FOR DPSR 33254.                                                D44015J
*                                                                        D44015J
*                                                                        MY8001J
* MY8     JES    79/06/20                                                MY8001J
*         MODSET CORRECTS THE BC PROGRAM IN MODULE MY800 SO THAT         MY8001J
*         THE CODE AGREES WITH THE DOCUMENTATION (REPLACES 0901          MY8001J
*         WITH 0900 - WAIT FOR CH0 BIT 0 (FUNCTION)). DPSR 31009.        MY8001J
*                                                                        MY8001J
*                                                                        MY8002G
* MY8     GLG    79/06/22.                                               MY8002G
*         MODSET CORRECTS MY8 TO SET WC REGISTER OVER FUNC COMMAND.      MY8002G
*         MODSET DIMA142 CHANGED MLD TO CLEAR WT REGISTER ON FUNC        MY8002G
*         AND MY8 EXPECTS IT TO NOT BE CLEARED.                          MY8002G
*                                                                        MY8002G
*                                                                        BCX001J
* BCX     JES    79/06/20                                                BCX001J
*         MODSET CORRECTS THE BC PROGRAM IN MODULE BCX00 SO THAT         BCX001J
*         THE CODE AGREES WITH THE DOCUMENTATION (REPLACES 0901          BCX001J
*         WITH 0900 - WAIT FOR CH0 BIT 0 (FUNCTION)). DPSR 31010.        BCX001J
*                                                                        BCX001J
*                                                                        BCX002G
* BCX     GLG    79/06/22.                                               BCX002G
*         MODSET CORRECTS BCX TO SET WC REGISTER OVER FUNC COMMAND.      BCX002G
*         MODSET DIMA142 CHANGED MLD TO CLEAR WT REGISTER ON FUNC        BCX002G
*         AND BCX EXPECTS IT TO NOT BE CLEARED.                          BCX002G
*                                                                        BCX002G
*                                                                        T7X015J
* T7X     JES    79/04/13                                                T7X015J
*         MODSET CORRECTS MODULE 56 (RANDOM WRITE) SO THAT IT CAN        T7X015J
*         DETECT A FAILURE MODE CURRENTLY ONLY DETECTABLE BY CEAIDS      T7X015J
*         T7X.  THIS OCCURS DUE TO THE FACT THAT RANDOM DATA PATTERNS    T7X015J
*         ARE CREATED FOR EACH RECORD WRITTEN AND THE UNIT IS NOT        T7X015J
*         DRIVEN AS HARD AS IT MUST BE DRIVEN TO SEE THE FAILURE.        T7X015J
*         DPSR 31011.                                                    T7X015J
*                                                                        T7X015J
*                                                                        MAL046G
* MALCMP  GLG    79/06/21.                                               MAL046G
* MALETP0 MODSET CORRECTS COMPILER ERROR WHERE ACN INSTRUCTION           MAL046G
*         WAS BEING GENERATED FOR A MSG P0 COMMAND.  MODSET ALSO         MAL046G
*         CORRECTS TIMEOUT COMMAND WHERE VALUE FOR TYPEA WAS NOT         MAL046G
*         STORED INTO REGISTERS IF CONSTANT USED.                        MAL046G
*                                                                        MAL046G
*                                                                        MAL048G
* MALCMP  GLG    79/06/26.                                               MAL048G
*         MODSET CORRECTS MALET COMPILER TO CUT SET P INSTRUCTIONS       MAL048G
*         FOR RANDOM COMMAND.                                            MAL048G
*                                                                        MAL048G
*                                                                        MAL049G
* MALCMP  GLG    79/06/26.                                               MAL049G
*         MODSET CORRECTS MALET COMPILER TO NOT ALLOW END COMMAND        MAL049G
*         ON AN IF STATEMENT.                                            MAL049G
*                                                                        MAL049G
*                                                                        MAL050G
* MALCMP  GLG    79/06/26.                                               MAL050G
*         MODSET CORRECTS MALET COMPILER TO GENERATE CORRECT CODE        MAL050G
*         IF PARAMETER REGISTER IS USED ON LEFT SIDE OF A REPLACEMENT    MAL050G
*         STATEMENT.                                                     MAL050G
*                                                                        MAL050G
*                                                                        MAL051G
* MALCMP  GLG    79/06/26.                                               MAL051G
*         MODSET CORRECTS MALET COMPILER USAGE OF P REGISTER             MAL051G
*         WITHIN COMMANDS TO NOT GROUP IT WITH RT REGISTER               MAL051G
*         BUT GROUP IT WITH B REGISTERS.                                 MAL051G
*                                                                        MAL051G
*                                                                        CL110PD
* HISTORY RBD   79/06/30.                                                CL110PD
*         THIS MODSET ADDS THE BUILD LEVEL INDICATOR                     CL110PD
*         TO THE CORRECTION SET IDENTIFIERS AND THIS                     CL110PD
*         HISTORY STATEMENT.  ALSO DECKS FMU AND ATC                     CL110PD
*         WERE RE-SEQUENCED FOR RELEASE.                                 CL110PD
*                                                                        CL110PD
*                                                                        HPA404R
*         DPSR 30857                                                     HPA404R
*         DPSR 30858                                                     HPA404R
*         DPSR 30859                                                     HPA404R
*         DPSR 30860                                                     HPA404R
* HPA     REF    06/28/79                                                HPA404R
*         MODSET ACCOMPLISHES THE FOLLOWING, IN RESPONSE TO THE ABOVE-   HPA404R
*         MENTIONED DPSR'S:                                              HPA404R
*         1) REMOVES THE EXTRANEOUS VSN HEADER FROM THE UNRECOVERED      HPA404R
*            ERRORS SECTION OF TAPE ANALYSIS REPORTS;                    HPA404R
*         2) AMENDS 66X AND 67X DETAIL HEADERS FOR TAPE REPORTS TO       HPA404R
*            ACCURATELY REFLECT THE TYPE OF STATUS BEING REPORTED;       HPA404R
*         3) REMOVES AN EXTRA REPORT DIVIDER FROM THE POSITION           HPA404R
*            ANALYSIS SUMMARY OF 844 ANALYSIS REPORTS;                   HPA404R
*         4) FLUSHES THE VSN COUNTER APPROPRIATELY WHEN THE              HPA404R
*            NEXT RECORD IS NOT A TAPE RECORD TYPE.                      HPA404R
*                                                                        HPA404R
*  DECK  TEF 79/07/02                                                    HPA403T
*        FIXES FILE POSITIONING PROBLEM IN HPA1                          HPA403T
*        FIXES SORT PROBLEM IN HPA2                                      HPA403T
*        SETS QUALIFIER FOR SORT OF SHR 40S                              HPA403T
*        FIXES GENERATION OF EXTRA SHR 32                                HPA403T
*        FIXES SORT PROBLEM IN HPA4                                      HPA403T
*        FIXES MERGE PROBLEM IN HPA4                                     HPA403T
*                                                                        HPA403T
*                                                                        HPA403T
*  DECK JLP 79/07/02                                                     HPA402J
*        FIXES ITEM EDITOR FOR SITE MANAGER                              HPA402J
*                                                                        HPA402J
*                                                                        HPA402J
*                                                                        HPA403J
*  HPA      JRJ    79/06/15                                              HPA403J
*                                                                        HPA403J
*     MODSET CHANGES THE NAME OF TWO INDEX VARIABLES IN OVERLAY 4        HPA403J
*                                                                        HPA403J
*     FROM:   OLD        TO:   OLDXX                                     HPA403J
*             NEW              NEWXX                                     HPA403J
*                                                                        HPA403J
*  HPA   RAH 79/07/02                                                    HPA407R
*        THIS MOD CORRECTS TRANSMITTAL PROBLEMS, REVISES                 HPA407R
*        TIME ARRAY DOCUMENTATION, TURNS OFF GRAPHS WHEN                 HPA407R
*        DATA IS NOT AVAILABLE, ADDS OPERATOR MESSAGES                   HPA407R
*        TO THE DETAIL REPORT, IDENTIFIES MESSAGES, AND                  HPA407R
*        ADDS AN OPTIME MESSAGE TO THE MTBI REPORT.                      HPA407R
*                                                                        HPA407R
*                                                                        HPA407R
*                                                                        D44013J
*D44      JMO    79/07/02.                                               D44013J
*         MODSET CORECTS ASSEMBLY ERRORS FOR D44012 AND D44015.          D44013J
*         DPSR 33257.                                                    D44013J
*                                                                        D44013J
*                                                                        CL110PE
* HISTORY  RBD  70/07/06.                                                CL110PE
*          THIS MODSET ADDS THE BUILD LEVEL INDICATOR TO                 CL110PE
*          THE CORRECTION SET IDENTIFIERS AND THIS HISTORY               CL110PE
*          STATEMENT.                                                    CL110PE
*                                                                        CL110PE
*                                                                        T5X001G
* T5X     GLG    79/07/03.                                               T5X001G
*         MODSET CORRECTS BUFFER INDEX OR WC ERRORS IN                   T5X001G
*         MODULES T5X23 AND T5X43 ON CML 3.1. CODE FOR DPSR 34872.       T5X001G
*                                                                        T5X001G
*                                                                        MAL052G
* MALET   GLG    79/07/10.                                               MAL052G
* MALETP0 MODSET INCREASES TIMEOUT DELAYS ALLOWED TO 2 SECONDS           MAL052G
*         AND ADDS ABLITY TO USE MSEC ON STATEMENT.                      MAL052G
*                                                                        MAL052G
*                                                                        CL110PF
* HISTORY  PWL  79/07/16                                                 CL110PF
*          THIS MODSET ADDS THE BUILD LEVEL INDICATOR TO                 CL110PF
*          THE CORRECTION SET IDENTIFIERS AND THIS HISTORY               CL110PF
*          STATEMENT.                                                    CL110PF
*/MODSET *CL110PF* CONTAINS 11 CARDS INCLUDING THIS COMMENT              CL110PF
*  HPA   TEF  79/07/20                                                   HPA404T
*        CORRECTS TRANSMIT PROBLEM                                       HPA404T
*        CORRECTS EXCESS GRAPH GENERATION                                HPA404T
*        CORRECTS SUMMARY REPORT OVERFLOW PROBLEM                        HPA404T
*                                                                        HPA404T
*                                                                        HPA404T
*  HPA   JLP  79/07/20                                                   HPA403J
*        CORRECTS PROBLEMS IN SPA ITEM EDITOR                            HPA403J
*                                                                        HPA403J
*                                                                        HPA403J
*                                                                        INS004J
* INSTLDKS       JMO    79/07/26.                                        INS004J
*         MODSET CORRECTS THE INSTALL DECK FOR NOSBE R4 AND R5           INS004J
*         TO FIX THE FIELD LENGTH ON TIO WHICH IS TOO SMALL.             INS004J
*         DPSR 34859.                                                    INS004J
*                                                                        INS004J
*                                                                        CL110PG
* HISTORY  PWL  79/07/27                                                 CL110PG
*          THIS MODSET ADDS THE BUILD LEVEL INDICATOR TO                 CL110PG
*          THE CORRECTION SET IDENTIFIERS AND THIS HISTORY               CL110PG
*          STATEMENT.                                                    CL110PG
* REGEN   JMO    79/06/08 
*         MODSET ADDS DOCUMENTATION FOR END CASE DIFFERENCES FOR
*         DPSR 23687. 
*     HPA35  RAZ   79/07/30 
*     DPSR  30848 
*         THE TERMINAL ADDRESS AND CLUSTER ADDRESS FOR 2550 ERROR 
*         CODE 12(UPLINE BREAK) ARE REPORTED INCORRECTLY. THIS MOD WILL 
*         SET THE CORRECT DATA IN THE CORRESPONDING PRINT BUFFER. 
*   HPA3/HPA35   RAZ    79/07/19
*         DPSR  14648 
*         IF HPA TRIES TO PROCESS LCC DATA IT WILL FAIL TO RUN BECAUSE
*         OF MISSING FORMAT STATEMENTS. THIS MODSET CORRECTS THE PROBLEM
*         AND PUTS THE DATA IN THE CORRECT FORM FOR PRINTING. 
* 
* T7X     JES    79/09/18 
*         THIS MODSET ADDS MODULES T7X61 (9TK READ RECOVERY) AND
*         T7X62 (READ CLIP LEVELS TEST) TO T7X.  THESE TWO MODULES
*         PARTIALLY SATISFY DPSR 025876 AND ARE BEING SUPPLIED EARLY
*         SO THAT MANUFACTURING CAN SATISFY TOTAL UNIT TESTING WITH 
*         T7X (NO NEED FOR ON-LINE AND OFF-LINE TESTING). 
* 
* 
* HISTORY        RAF  79/10/02. 
*                THIS MODSET ADDS THE BUILD LEVEL INDICATOR 
*                TO THE CORRECTION SET IDENTIFIERS AND THIS 
*                HISTORY STATEMENT. 
* 
*                                                                        MAL31A1
* MALET   GLG    79/06/08.                                               MAL31A1
* MALET10 MODSET ADDS CVL CALL CODE FOR MSS TO MALET AND CORRECTS        MAL31A1
* MALET11 DOCUMENTATION WITHIN MALET LISTING.                            MAL31A1
*                                                                        MAL31A1
*                                                                        MLT001K
* MLTDOC KBS  79/10/05.                                                  MLT001K
*                                                                        MLT001K
*        ADDS TRADE SECRET/PROPRIETARY BANNERS TO MLTDOC OUTPUT.         MLT001K
*        (DPSR 34954)                                                    MLT001K
*                                                                        MLT001K
*                                                                        HPA31A1
*         DPSR 032024                                                    HPA31A1
* HPA36,HPA3     JPD     79/10/16                                        HPA31A1
*         MODSET CORRECTS MANY PROBLEMS IN THE LOWER CYBER SCR           HPA31A1
*         DETAIL AND ANALYSIS REPORTS FOR HPA.  THE PREVIOUS CODE FOR    HPA31A1
*         THE LOWER CYBERS HAS BEEN DELETED AND THE NEW CODE             HPA31A1
*         MERGED INTO THE CODE FOR THE CYBER 176 REPORTING.  ALSO        HPA31A1
*         ANY KNOWN PROBLEMS IN THE CYBER 176 REPORT WAS CORRECTED.      HPA31A1
*                                                                        HPA31A1
*                                                                        HPA31C1
*         DPSR 038001                                                    HPA31C1
* HISTORY JPD     79/10/16                                               HPA31C1
*         MODSET CORRECTS PROBLEMS IN THE HISTORY DECK FOR THE           HPA31C1
*         DESCRIPTIONS OF R2FECS AND R2DFMD MODSETS.                     HPA31C1
*                                                                        HPA31C1
*                                                                        D44016J
* D44     JMO    79/09/24                                                D44016J
*         MODSET CORRECTS FMD PROBLEMS IN MODULE 02.                     D44016J
*         DPSR 34895.                                                    D44016J
*                                                                        MAL31B1
* MALET11 GLG    79/10/23.                                               MAL31B1
*         MODSET CORRECTS CVL CALL ERROR CAUSED WHEN EST IS NOT          MAL31B1
*         PROVIDED ON EQUIPMENT ASSIGNMENT WHEN THE EQUIPMENT            MAL31B1
*         IS RETURNED. DPSR 34915 REPORTED PROBLEM.                      MAL31B1
*                                                                        MAL31B1
*                                                                        HPA31B1
*         DPSR 034996                                                    HPA31B1
* HPA38   JPD     79/10/16                                               HPA31B1
*         MODSET ADDS MEMORY BOARD ANALYSIS AND FAILING BIT TO           HPA31B1
*         THE M2 DETAIL AND ANALYSIS REPORTS OF HPA.                     HPA31B1
*                                                                        HPA31B1
*         DPSR 38024                                                     HPA31D1
* HPA     REF  10/24/79                                                  HPA31D1
*         MODSET SETS A FLAG IN THE GCR TAPE DETAIL REPORT FOR THE       HPA31D1
*         OCCURRENCE OF A WRITE ERROR WITH THE ERROR CORRECTION          HPA31D1
*         DISABLED BIT SET.  FLAG WILL APPEAR AS AN ASTERISK IN THE      HPA31D1
*         UNIT TYPE COLUMN AS FOLLOWS: GCR*.                             HPA31D1
*                                                                        HPA31D1
*                                                                        HPA31F1
*         DPSR  038007                                                   HPA31F1
* HPA     TEF     79/10/29                                               HPA31F1
*         MODSET CORRECTS REWIND PROBLEM IN HPA1                         HPA31F1
*                CORRECTS ENDLESS LOOP PROBLEM IN HPA5                   HPA31F1
*                ENABLES LDSET CHECKS IN HPA WITH DEBUG DEFINED          HPA31F1
*                CORRECTS SPELLING ERRORS IN HPA4                        HPA31F1
*                                                                        HPA31F1
*                                                                        HPA31E1
*         HPA31E110                                                      HPA31E1
* HPA     RAH    10/26/79                                                HPA31E1
*         MODSET CHANGES 52/53 ERRORS TO COMMENTS AND                    HPA31E1
*         ZERO FILLS RIGHT JUSTIFIED NUMERIC FIELDS                      HPA31E1
* HISTORY     RAF  79/11/02                                              CL110PI
*             THIS MODSET ADDS THE BUILD LEVEL INDICATOR                 CL110PI
*             TO THE CORRECTION SET IDENTIFIERS AND THIS                 CL110PI
*             HISTORY STATEMENT.                                         CL110PI
*                                                                        CL110PI
*/MODSET *CL110PI* CONTAINS 12 CARDS INCLUDING THIS COMMENT.             CL110PI
*                                                                        RT531A1
* RT5      DDN    79/11/12                                               RT531A1
*          MODSET CORRECTS FORMAT FOR TERMINAL OUTPUT ON MODULE 22       RT531A1
*          DPSR 006249                                                   RT531A1
*                                                                        RT531A1
*  HPA   TEF  79/11/19                                                   HPA31G1
*        MODSET HPA31G111 CORRECTS DOCUMENTATION IN HPA2                 HPA31G1
*                                                                        HPA31G1
*                                                                        HPA31G1
*                                                                        MAL31C1
* MALET   GLG    79/10/25.                                               MAL31C1
*         MODSET CORRECTS MALET TO REQUEST BOTH CSU AND MST              MAL31C1
*         ON SEPERATE CVL CALLS.  MODSET ADDS IN CORRECT CVL             MAL31C1
*         RESPONSE CODES FOR 20-32 WHICH WERE NOT BEING HANDLED          MAL31C1
*         BY MALET.  MODSET MODIFIES ASSIGN TO NOT SET BY 2**48          MAL31C1
*         WHEN C=NONE OR C=7777 ON MST ASSIGNMENT FOR CVL CALL.          MAL31C1
*         DPSR 38004 DOCUMENTS PROBLEM.                                  MAL31C1
*                                                                        MAL31C1
* HISTORY     RAF  79/12/05                                              CL111PL
*             THIS MODSET ADDS THE BUILD LEVEL INDICATOR                 CL111PL
*             TO THE CORRECTION SET IDENTIFIERS AND THIS                 CL111PL
*             HISTORY STATEMENT.                                         CL111PL
*                                                                        CL111PL
*/MODSET *CL111PL* CONTAINS 11 CARDS INCLUDING THIS COMMENT.             CL111PL
* 
* T7X     JES    79/12/10 
*         THIS MODSET SATISFIES DPSR 025876 BY SUPPLYING THE FOLLOWING
*         NEW MODULES FOR T7X;
* 
*           T7X75 - SEARCH FILE MARK TEST 
*           T7X76 - NOISE BYPASS TEST 
*           T7X77 - WARMSTART READ TEST 
*           T7X988- STATUS REPORTING FOR LOW-LEVEL MODULES
* 
* 
*FTP      DDN     79/11/26
*         MODSET CORRECTS TRAIN SELECT MODULE 12
*         DPSR 034936 
* 
* 
* D44     DDN    79/12/10 
*         MODSET CORRECTS MODULE 45 SPELLING ERROR
*         DPSR 038035 
* 
* 
* TT3      DDN    79/12/79
*          MODSET CORRECTS CHANNEL NOT RESERVED ERROR 
*          DPSR 010173
* 
*  HPA7  TEF  79/12/19
*        MODSET CORRECTS UNINITIALIZED VARIABLE CFLAG IN SUBROUTINE 
*        TRANS7 CAUSING A MODE 4 ABORT IN OVERLAY 7 
* 
* 
*  HPA7  TEF  79/12/20
*        MODSET CORRECTS CONDITION CAUSING A MODE 1 ABORT WHEN D = SY 
*        IS SELECTED AND A SEF IS UNAVAILABLE 
* 
* 
* 
* D44     JMO    79/11/30 
*         MODSET CORRECTS DOCUMENTATION FOR P7 MARGINS AND
*         ADDS A MARGINS SELECT CODE (B2) FOR INTERROGATION 
*         IN MODULE 13 UPON ERROR. DPSR 034176. 
* 
* 
* D44     DDN    80/01/02 
*         MODSET ADDS EXTERNAL DOCUMENTATION INFORMATION
*         DPSR 034177 
* 
* 
* HPA3     PWL   80/01/02 
*          MODSET SEPARATES ERROR LOG ENTRIES BY DAY, 
*          CORRECTS ERROR COUNT TOTALS IN SUMMARY REPORT
*          (S=1) AND ELIMINATES DUPLICATE ENTRIES OF
*          SYSTEM MESSAGE WHEN HW PARAMETER IS USED.
* 
* 
* MALET10 KBS    79/11/28 
* 
*         CORRECTS PROBLEM OF ZERO DATA BLANKING K/L DISPLAY WHEN 
*         DISPLAYED WITH *A FORMAT.  PROBLEM WAS REPORTED IN
*         DPSR 031649.
* 
* HISTORY RBD  80/01/14.
*         THIS MODSET ADDS THE BUILD LEVEL IDENTIFIER 
*         TO THE CORRECTION SET IDENTIFIERS AND THIS
*         HISTORY STATEMENT.  TFF WAS ADDED TO THE
*         LIBRARY DURING THIS BUILD.
*                                                                        HPA0199
* HPA5     PWL  80/01/08                                                 HPA0199
*          MODSET SEPARATES SYSTEM PERFERMANCE REPORT                    HPA0199
*          ENTRIES BY DEVICE TYPE, PRINTS DATA FOR ALL                   HPA0199
*          DEVICE TYPES IN MTBF INDEX REPORT BY DEVICE                   HPA0199
*          TYPE.                                                         HPA0199
*                                                                        HPA0199
*                                                                        HPA0319
* HPA1    PWL  80/01/02                                                  HPA0319
*         MODSET PRINTS TIMING MESSAGE FROM HPA1                         HPA0319
*         WHEN X=T PARAMETER OPTION IS USED.                             HPA0319
*                                                                        HPA0319
*                                                                        HPA0331
*        DPSR 033184                                                     HPA0331
* HPA    REF   01/16/80                                                  HPA0331
*        MODSET VERIFIES THE PRESENCE OF AN OLD HISTORY FILE WHEN IT IS  HPA0331
*        REQUIRED BY HPA PARAMETERS.  IF NO OLD HISTORY IS PRESENT, A    HPA0331
*        MESSAGE WILL RESULT.                                            HPA0331
*                                                                        HPA0331
*                                                                        HPA0380
*        DPSR 038036                                                     HPA0380
* HPA    REF  01/13/80                                                   HPA0380
*        MODSET CORRECTS THE PHYSICAL TAPE UNIT NUMBER PRINTED IN THE    HPA0380
*        DETAIL AND ANALYSIS REPORT HEADERS. SINCE THE LARGEST VALID     HPA0380
*        TAPE UNIT NUMBER IS 17 OCTAL, THE VARIABLE REQUIRES ONLY 4 BITS HPA0380
*        OF DATA FOR REPRESENTATION.                                     HPA0380
*                                                                        HPA0380
*  HPA34  RTG  80/01/16                                                  HPA0276
*        MODSET CORRECTS REPORTING OF THE PACK-ID IN THE                 HPA0276
*        UNIT ANALYSIS FLAW REPORT                                       HPA0276
*                                                                        HPA0276
*                                                                        HPA0276
*                                                                        HPA0319
*        DPSR 031967                                                     HPA0319
* HPA    REF   01/04/80                                                  HPA0319
*        MODSET ENABLES THE USE OF A SEF INPUT FILE FOR TAPE MEDIA       HPA0319
*        REPORTS WITH THE HW RETRIEVAL PARAMETER.  PREVIOUSLY, THE       HPA0319
*        HW (HISTORY WINDOW) PARAMETER PREVENTED PROCESSING OF A SEF     HPA0319
*        FILE FOR MEDIA REPORTS AND RESULTED IN A SYSTEM FATAL ERROR.    HPA0319
*                                                                        HPA0319
*                                                                        HPA0332
*        DPSR 033200                                                     HPA0332
* HPA    REF   01/21/80                                                  HPA0332
*        MODSET CORRECTS THE X=BF (BRIEF FORMAT) TO SUPPRESS THE LISTING HPA0332
*        OF FILE ASSIGNMENTS AND INPUT PARAMETERS FOR HPA REPORTS.       HPA0332
*                                                                        HPA0332
*                                                                        HPA0310
* HPA031047       GAS   11/1/79                                          HPA0310
*               MODSET ADDS INTERNAL SORT CAPABILITY TO HPA              HPA0310
*               TO ALLOW RUNNING HPA ON SYSTEM WITHOUT SORT/MERGE.       HPA0310
*                                                                        HPA0310
*                                                                        HPA0199
* HPA3     PWL  80/01/14                                                 HPA0199
* HPA5     MODSET CORRECTS CHANNEL ERROR COUNTS IN                       HPA0199
*          SUMMARY REPORT (S=2).                                         HPA0199
*                                                                        HPA0199
*  HPA7  TEF  80/01/16                                                   HPA0319
*        MODSET CORRECTS STRAY NAME IN SUBROUTINE TRANS7                 HPA0319
*                                                                        HPA0319
*                                                                        HPA0319
*  HPA5  TEF  80/01/22                                                   HPA0149
*        MODSET ALLOWS INITIAL PRINTING OF TWO GRAPHS ON FIRST PAGE      HPA0149
*                                                                        HPA0149
*                                                                        HPA0149
*  HPA7  TEF  80/01/16                                                   HPA0319
*        MODSET DELETES STRAY NAME VARIABLE PZFLG IN SUBROUTINE TRANS7   HPA0319
*                                                                        HPA0319
*                                                                        HPA0319
*  HPA7  TEF  80/01/23                                                   HPA0376
*        MODSET FIXES INCORRECT DEFINITION OF VARIABLE RTY IN            HPA0376
*        SUBROUTINE DL1CY7 CAUSING A MODE 1 FAILURE IN SETFLDS           HPA0376
*                                                                        HPA0376
*                                                                        HPA0376
*  HPA7  TEF  80/01/17                                                   HPA0319
*        MODSET CORRECTS USE OF PF PARAMETER IN SY DETAIL                HPA0319
*        AND ANALYSIS REPORTS                                            HPA0319
*                                                                        HPA0319
*                                                                        HPA0319
*  HPA8  TEF  80/01/15                                                   HPA0319
*        MODSET CORRECTS UNINITIALIZED VARIABLE ICYBEDT CAUSING A SEF    HPA0319
*        ENTRY TO BE DELETED FROM MOST RECENT DATE IN NEW HISTORY        HPA0319
*                                                                        HPA0319
*                                                                        HPA0319
*                                                                        MAL0376
* MALET   GLG    80/02/03.                                               MAL0376
*         MODSET CORRECTS ASSEMBLY ERROR WITHIN MALET CAUSED             MAL0376
*         BY CHANGE TO COMSSSJ XTEXT.  CONFLICT IN TAG NAME              MAL0376
*         FRT.  DPSR 37642 REPORTED PROBLEM.                             MAL0376
*                                                                        MAL0376
*                                                                        CL113PL
* HISTORY RBD    80/02/04                                                CL113PL
*         THIS MODSET UPDATES THE BUILD                                  CL113PL
*         IDENTIFER.                                                     CL113PL
*                                                                        CL113PL
*                                                                        D440153
* D44     JMO    80/01/28                                                D440153
*                MODSET CORRECTS INCOMPLETE MESSAGES IN                  D440153
*                MODULES 42,43,44,45 AND 46.                             D440153
*                                                                        D440153
*                                                                        HPA0349
*HPA3      PWL  80/02/05                                                 HPA0349
*HPERS     MODSET ADDS ERROR CODE 174B TO PROCESS                        HPA0349
*          "PRINT ERROR LIMIT EXCEEDED" MESSAGE.                         HPA0349
*                                                                        HPA0349
*                                                                        HPA0192
*HPA       PWL  80/02/01                                                 HPA0192
*          MODSET CHANGES OVERLAY LEVEL NUMBERS TO                       HPA0192
*          OCTAL IN HPA CALL OVERLAY STATEMENTS.                         HPA0192
*                                                                        HPA0192
*                                                                        MAL0063
* MALET10 DDN    80/01/25.                                               MAL0063
*         MODSET CORRECTS OVERFLOW ON PICTURE COMMANDS IF                MAL0063
*         NOT PPU DISPLAY PICTURE. DPSR 006324 REPORTED                  MAL0063
*         PROBLEM.                                                       MAL0063
*                                                                        MAL0063
*                                                                        INS0294
* INSTLDKS GLG   80/02/05.                                               INS0294
*         MODSET CORRECTS COMMENTS ON NOSBE INSTLDKS FOR                 INS0294
*         USER EDITLIB.  REPORTED BY DPSR 29469 AND PSR                  INS0294
*         DIM0235.                                                       INS0294
*                                                                        INS0294
*                                                                        T7X0380
* T7X     GDW    80/02/01                                                T7X0380
*         MODSET CORRECTS DATA STATEMENTS IN MODULES T7X75,              T7X0380
*         T7X76, AND T7X77 WHICH CAUSE ERRORS WHEN RUN.                  T7X0380
*         PROBLEM REPORTED BY DPSR 38012.                                T7X0380
*                                                                        T7X0380
*                                                                        HPA0319
* HPA     JLP 80/02/05                                                   HPA0319
*         THIS MOD PREVENTS USING A FILE IF THE FILE WAS SET TO ZERO     HPA0319
*         ON THE CONTROL STATEMENT.  THIS PREVENTS A RECORD MANAGER 165  HPA0319
*         ERROR.                                                         HPA0319
*                                                                        HPA0319
*                                                                        HPA0376
*        DPSR 037609                                                     HPA0376
* HPA    REF   01/23/80                                                  HPA0376
*        MODSET CORRECTS HPA PROGRAM FLOW WITH THE ELIMINATION           HPA0376
*        OF UNNECESSARY CALL TO OVERLAY SEQUENCE 2(SORT), 7 AND 8.       HPA0376
*                                                                        HPA0376
*                                                                        *CL113P
* HISTORY RRD    80/02/04                                                *CL113P
*         THIS MODSET UPDATES THE BUILD                                  *CL113P
*         IDENTIFER. IT ALSO IDENTIFIES THE                              *CL113P
*         BUILD AFTER FEATURE CODE CUT OFF.                              *CL113P
*                                                                        *CL113P
* 
* MALET11 GLG    80/02/25.
*         MODSET CORRECTS MALET PROBLEM WITH PRE-ASSIGNMENT OF TAPES
*         REPORTED BY DPSR 38055. 
* 
* 
* HPA      TEF  79/02/25
*          MODSET CHANGES REVISION NUMBER FROM R2G TO R2H 
* 
* 
* HPA35   TEF 80/02/08
*         HPA MODES OUT WHEN CHART3 IS CALLED BY AN5FE3 WITH
*         PARAMETED IX EQUAL TO 0 
* 
* 
* MALET   GLG    80/02/15.
*         MODSET CORRECTS MALET TO DROP IF RANDOM FILE FULL AND 
*         MALET RUNNING IN BATCH MODE. PROBLEM REPORTED BY
*         DPSR 034571.
* 
*  HPA5  RTG  80/01/17
*         MODSET ADDS UNIT NUMBER TO S=1 REPORT 
* 
* 
* 
* HISTORY RBD    80/03/06 
*         THIS MODSET UPDATES THE BUILD IDENTIFIER
*         FOR CML 3.1 LEVEL 114 RELEASE.
* 
* 
* FMC031013 HNS 80/01/28
* 
*         FMC01 - DATA STATEMENT ERROR. 
* 
* 
* FMC019945 HNS 80/01/28
* 
*         FMC08 - ERROR COUNT MESSAGE WITHOUT ERRORS. 
*         FMC09 - ERROR COUNT MESSAGE WITHOUT ERRORS. 
* 
* 
* FMC019964 HNS 80/02/04
* 
*         FMC16C - DETECTION/ISOLATION DATA MISSING 
* 
* 
* FMC010176 HNS 80/01/28
* 
*         FMC19 - DAYFILE ERROR MESSAGE MISSING.
* 
* 
* FMC031004 HNS 80/01/28
* 
*         FMC08 - MISSING MESSAGE.
* 
* 
* FMC008380 HNS 80/01/28
* 
*         THE RUNNING MESSAGE SHOULD NOT BE SENT TO THE DAYFILE.
* 
* 
* FMC008390 HNS 80/01/28
* 
*         FMC04 - DAYFILE ERROR MESSAGE MISSING.
*         FMC31 - DAYFILE ERROR MESSAGE MISSING.
* 
* 
* FTP     DDN    80/02/22 
*         MODSET INSURES MODULE 20 READS THE CORRECT
*         STATUS ON THE LOW LEVEL STATUS COMMAND. 
*         DPSR 032877 
* 
* 
* FTP     DDN    80/02/19 
*         MODSET CORRECTS PROBLEM IN MODULE 98B CAUSING 
*         MODULE 5 TO GET PRINT ERRORS AND COMPARE FAULT
*         USING TRAIN TYPES 2 OR 3.  DPSR 034938. 
* 
* 
* T5X     JMO    80/02/05 
*         ENHANCEMENT ALLOWS DATA COMPARE IF P3 EQUALS
*         XXX2 AND ALERT IS DETECTED. FEATURE DPSR NUMBER 
*         IS 033267 AND ENHANCEMENT DPSR IS 034920. 
* 
* 
* FMC037661 HNS 80/02/14
* 
*         FMC02 - AUTOLOAD WITH OPTIONAL 77-TABLE.
* 
* 
* HISTORY RBD    80/03/06 
*         THIS MODSET UPDATES THE BUILD IDENTIFIER
*         FOR THIS BUILD. 
* 
* 
* D44     JMO    80/02/07 
*         MODSET CORRECTS STATUS ERRORS IN MODULE 10
*         WHILE DOING SHORT READS ON A 7155 AND 844S. 
*         DPSR 037667.
* 
* 
* T7X     JMO    80/02/05 
*         ENHANCEMENT ALLOWS DATA COMPARE IF P3 EQUALS
*         XXX2 AND ALERT IS DETECTED. FEATURE DPSR NUMBER 
*         IS 033267 AND ENHANCEMENT DPSR IS 034919. 
* 
* 
* FMC037611 HNS 80/01/16
* 
*         FMC04 - ERROR MESSAGE NUMBER 64003 IS INCOMPLETE. 
*         THE CORRECTION SET ADDS THE WORDS *DETAILED STATUS* TO
*         COMPLETE THE ERROR MESSAGE. 
* 
*         FMC ALL - OTHER INCOMPLETE MESSAGES ARE CORRECTED.
* 
* 
* FMC031017 HNS 80/02/19
* 
*         FMC01B - WRONG FORMAT NUMBERS USED. 
* 
* 
* FMD031651 HNS 80/02/22
* 
*         FMD70 - CHANGE AVG. POSITIONER TIME TO 335 MICROSECONDS.
* 
* 
* FMC008381 HNS 80/02/19
* 
*         UNUSED FORMAT STATEMENTS. 
* 
* 
* FMC031025 HNS 80/03/13
* 
*         FMC03A - BAD DATA REPORTED ON ERROR.
* 
* 
* D88024479 HNS 80/03/07
* 
*         D88 - INCORRECT ABORT MESSAGE.
* 
* 
* D88024499 HNS 80/03/07
* 
*         D8860 - WRONG ERROR PROCESSOR 
* 
* 
* FMC019966 HNS 80/01/28
* 
*         FMC16 - ISOLATION DATA MISSING FROM ERROR 69021 
*         FMC21 - DEVICE INTERFACE CARD ISOLATION MISSING FOR UN 50-57. 
*         FMC22 - DEVICE INTERFACE CARD ISOLATION MISSING FOR UN 50-57. 
*         FMC23 - DEVICE INTERFACE CARD ISOLATION MISSING FOR UN 50-57. 
*         FMC33A - ISOLATION DATA MISSING FROM ERROR 6F002 AND 6F003. 
* 
* 
* D88024596 HNS 80/03/10
* 
*         D88 - B0-B1 SHOULD BE B0-B15. 
*         D8899A - B0-B1 SHOULD BE B0-B15.
* 
* 
* HPA34    PWL  80/03/11
*          MODSET CORRECTS POS/HG/SEC IN 808
*          DETAIL REPORT. 
* 
* 
* D88024592 HNS 80/03/14
* 
*         D88 - ADD FMU DEPENDENCY TO RESTRICTIONS. 
* 
* 
* D88024593 HNS 80/03/14
* 
*         D88 - WRONG MALET CALL OPTIONS. 
* 
* 
* D88024487 HNS 80/03/07
* 
*         D88 - ERROR COUNTER NOT INCREMENTED 
* 
* 
* D88024594 HNS 80/03/14
* 
*         D88 - INCORRECT ASSIGN DIRECTIVES.
* 
*  HPA1  RTG  80/03/07
*        MODSET FOR AUTOMATIC SELECTION OF D WHEN DX IS USED
* 
* 
* 
* FMC024146 HNS 80/02/07
* 
*         FMC25 - INTERMITTENT NO SYNC BYTE MISCOMPARE ERROR. 
* 
* 
* HPA7    SLJ  80/03/25 
* 
*         CORRECTS PROBLEM OF GARBAGE ON TRANSMITTAL FILE AFTER 
*         TRANSMIT FLAG HAS BEEN SET. 
* 
* 
* D88024594 HNS 80/03/14
* 
*         D88 - DOCUMENTATION INCORRECT FOR NOS/BE. 
* 
* 
* D88024470 HNS 80/03/06
* 
*         D88 - INCORRECT MODULE NUMBERS
* 
* 
* D44     JES    80/03/17 
*         MODSET CORRECTS PROBLEMS IN MODULE D4410 (SHORT READ). IT 
*         IS CURRENTLY POSSIBLE TO GET A STATUS ERROR DURING THE
*         RANDOM DATA TEST SINCE THERE IS NO CHECK FOR THE RANDOM 
*         DATA WORD BEING ZERO - IF IT IS NO STATUS ERROR OCCURS BUT
*         ONE IS EXPECTED. ERROR REPORTING IS VERY BAD IN THIS MODULE 
*         AND IS CORRECTED. DPSR 010107.
* 
* 
* D44     JMO    80/02/04 
*         MODSET CORRECTS THE POSSIBILITY OF GOING INTO A LOOP
*         IN MODULES IF A FLAW IS DETECTED IN THE LAST TRACK
*         OF A CYLINDER. DPSR 027608. 
* 
* 
* MAL     GDW    80/03/21 
*         MODSET CORRECTS MALET TO PROVIDE INTENSIFICATION OF 
*         CONTROL POINT MESSAGE *GO/DROP* TO CONSOLE OPERATOR 
*         WHEN ASSIGNING EQUIPMENT NEEDED TO EXECUTE MALET
*         DIAGNOSTICS LOADED FROM AN INTERACTIVE TERMINAL.
*         PROBLEM REPORTED BY DPSR 36104. 
* 
* 
* FMC       HNS 80/02/04
* 
*         FMC08/FMC09 - DONT WORK/PARITY SWITCH NOT TESTED. 
*         DPSR 034907 
* 
* 
* HPA      PWL  80/03/28
*          MODSET CORRECTS THE HANDLING OF LEAP YEAR. 
* 
* 
* BCX     JES    80/03/17 
*         MODSET ADDS THE TIMEOUT COMMAND TO MODULE BCX00 SUCH THAT 
*         THIS MODULE CAN BE USED FOR SCOPING PURPOSES IN REPAIRING 
*         A BUFFER CONTROLLER - TIMEOUTS ARE CURRENTLY OVER 250 MSEC
*         WHICH MAKES IT EXTREMELY DIFFICULT TO SCOPE. DPSR 010106. 
* 
* 
* MY8     JES    80/03/17 
*         MODSET ADDS THE TIMEOUT COMMAND TO MODULE MY800 SUCH THAT 
*         THIS MODULE CAN BE USED FOR SCOPING PURPOSES IN REPAIRING 
*         A BUFFER CONTROLLER - TIMEOUTS ARE CURRENTLY OVER 250 MSEC
*         WHICH MAKES IT EXTREMELY DIFFICULT TO SCOPE. DPSR 010105. 
* 
* 
* D88       HNS 80/03/21
* 
*         D88 - WORD COUNT NOT RESET. 
*         DPSR 024466 
* 
* 
* TFF     GDW    80/03/04 
*         MODSET CORRECTS FAILURE TO RUN ON 4X PP.
*         PROBLEM REPORTED BY DPSR 037663.
* 
* 
* HISTORY RBD    80/04/10 
*         THIS MODSET UPDATES THE BUILD IDENTIFIER
*         FOR THIS BUILD (CL115PL).  DECK T7W WAS 
*         MOVED TO THE CLASS 2 LIBRARY. 
* 
* 
* FMC       HNS 80/02/20
* 
*         FMC02 - MISSING STATUS CHECK AND MESSAGE. 
*         FMC28 - INCORRECT ERROR CALL
*         FMCALL - MISSING ISOLATION PARAMETER CHECK. 
*         FMCALL - *IF DEF TSP LENGTH INCORRECT.
*         FMCALL - INCORRECT EXIT ADDRESS.
*         FMCALL - ERROR COUNT MESSAGE CONFORMING TO MALET CODING SPEC. 
*         DPSR 037610 
* 
* 
* FMD       HNS 80/04/01
* 
*         FMD - DESCRIPTION 
*         DPSR 034911 
* 
* 
* TFL     GDW    80/03/31 
*         MODSET CORRECTS PROBLEM IN TFL CAUSING
*         IT TO LOOP FOREVER LOADING THE 2550.
*         PROBLEM REPORTED BY DPSR 038074.
* 
* 
* T5X     JMO    80/04/14 
*         MODSET CORRECTS THE PROBLEM OF GETTING ALTERNATE
*         PATTERNS IN MODULE 43 WHILE SELECTING CONSTANT
*         PATTERNS. DPSR 007269.
* 
* 
* HPA5     PWL  80/03/25
*          MODSET ADDS EQUIPMENT AND CHANNEL NUMBERS TO 
*          GRAPH TITLE AND ELIMINATES EMPTY GRAPHS. 
* 
* 
* MAL     GDW    80/04/01 
*         MODSET CORRECTS MALET ALPHA SUBSTITUTION
*         PROBLEM WHERE MALET WILL NOT USE
*         EITHER ONE OF THE SUBSTITUTABLE 
*         CHARACTERS IF EITHER ONE OF THEM
*         IS ILLEGAL (00,60B OR GREATER). 
*         PROBLEM REPORTED BY DPSR 038070.
* 
* 
* FMU     ALJ   80/04/17. 
*          THIS MODSET ADDS CODE TO DISPLAY ERROR 
*          MESSAGES IF ACCESS TOO LOW.
*          DPSR 036119
* 
* 
* FMU037659   ALJ  80/04/17.
*         THIS MODSET ADDS CODE FOR THE 77TABLE 
*         CHANGES IN DEMOT. 
* 
* 
* ATC     DME    80/04/23.
* 
*         COMMENTS, CORRECTION TO MODULES 30^32 
* 
* HPA35    PWL  80/04/22
*          MODSET FIXES CALLS TO PRINT3 BY AN5FE3 WITH OUT
*          OF RANGE PARAMETERS. 
* 
* 
* DECK     JLP 80/04/24 
*          THIS CORRECTION SET WILL IMPROVE THE PERFORMANCE OF HPA
*          BY REDUCING THE CORE REQUIREMENTS FOR EXECUTION. 
* 
*          THIS IS ACCOMPLISHED BY SPLITTING THE ERROR MESSAGE TABLE
*          INTO PARTS, AND PLACING THOSE PARTS IN THE 3.X OVERLAY 
*          IN WHICH THEY ARE USED INSTEAD OF RESIDENT MEMORY. 
* 
*          THIS MODSET CONSISTS OF IDENTIFIER "HPA037696", AND NEW
*          DECK AND COMDECK "HPA31" AND "COMCOMHPAERT". 
* 
* 
* ATC     DME    80/03/31.
*         COMMENTS REVISED MALET VERSION OF ATC GCR/NOT GCR.
* 
* 
* HISTORY RBD    80/05/13 
*         THIS MODSET UPDATES THE BUILD IDENTIFIER
*         FOR THIS BUILD (CL116PL).  DECK HPA31 AND 
*         COMMON DECKS COMHPAERT AND VERS WERE ADDED
*         TO THE LIBRARY. 
* 
* 
* MY8     JMO    80/04/14 
*         MDSET CORRECTS MY8 ERROR -NO BC RESPONSE TO FCN IN 30 SEC-
*         IN MODULE MY802. THE MODULE WAS NOT WAITING LONG ENOUGH FOR 
*         A BC RESPONSE WHEN RUNNING THE MEMORY TEST. DPSR 012623.
* 
* 
* T6X     JMO    80/05/01 
*         MODSET CORRECTS NO EXIT OF MODULES AFTER DETECTING END OF 
*         TAPE IN MODULES 14,15,16 AND 18. DPSR 022008. 
* 
* 
* T7X     JMO    80/06/02 
*         MODSET UPDATES THE DOCUMENTATION TO REFLECT THE USE OF
*         PARAMETER P1 2XXX AND 3XXX TO DISABLE ERROR CORRECTION. 
* 
* 
* FTP     DDN   05/05/80
*         MODSET CORRECTS IMAGE MEMORY TABLE FOR
*         A 596-4 AND 596-5 PRINT TRAIN.
*         DPSR 026311.
* 
* 
* MAL     GDW    80/05/15 
*         MODSET CORRECTS PROBLEM IN MALET DUE TO STRPPU NOT
*         CLEARING PREVIOUS NUMBER OUT BEFORE PUTTING IN NEW
*         NUMBER SUCH THAT WHEN DC 100 IS ASSIGNED ON MST=02, 
*         MSTPH=02 YOU CANNOT SWITCH BACK TO MST=00, MSTPH=00.
*         PROBLEM REPORTED BY DPSR 037695.
* 
* 
*MLT      KM     80/05/12 
*         FIXES PAGE NUMBERING ERRORS WHICH OCCUR 
*         WHEN TRYING TO PRINT MORE THAN 99 PAGES 
*         OF INTERNAL AND EXTERNAL DOCUMENTATION. 
* 
* 
* T7X     JMO    80/05/08 
*         MODSET CORRECTS MODULE 61A SO THAT ERROR CORRECTION 
*         CANNOT DISABLED FOR GCR UNITS. DPSR 035572. 
* 
* 
* HPA7    SLJ  80/05/06 
* 
* 
*         CORRECTS INTERRUPTION COUNTS FOR ANALYSIS AND 
*         GRAPH STATISTICS. 
* 
* HPA7    SLJ  80/05/06 
* 
*        CORRECTS GRAPH LABEL FOR DOWN EVENTS 
* 
* HPA4    SLJ  80/05/06 
* 
* 
*         CORRECTS CHANGE DETAIL COMMAND. 
* 
* HPA7    SLJ  80/05/06 
* 
* 
*         ADDS ABILITY TO RUN GRAPHS WITHOUT RUNNING THE ANALYSIS 
*         REPORT. 
* 
* HPA     JLP 80/06/04
*         THIS MODSET CHANGES THE VERSION IDENTIFICATION IN HPA 
*         TO USE THE CML BUILD LEVEL NUMBER INSTEAD OF A HARD-CODED 
*         INTERNAL BUILD IDENTIFIER.  IT ALSO CHANGES THE VERSION 
*         IDENTIFICATION TO IDENTIFY PRERELEASED/WORKING VERSIONS.
* 
* 
* HPA     JLP 80/05/16
*         THIS MODSET INSTALLS CODE TO DO AN ANALYSIS OF THE
*         DETAILED STATUS OF 844'S BY USE OF A DECISION 
*         LOGIC TABLE.
* 
* 
* D88       HNS 80/02/22
* 
*         D8813 - CHANGE AVG. POSITIONER TIME TO 335 MICROSECONDS.
*         DPSR 015771 
* 
* 
* HISTORY  RBD    80/07/03
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL117PL.
* 
* 
* HPA     JLP 80/07/10
*         THIS MODSET REPLACES THE CURRENT DLT TABLES USED BY HPA 
*         TO DO DETAILED STATUS ANALYSIS OF 844 ERRORS WITH AN UPDATED
*         SET OF TABLES DEVELOPED BY JIM SIPPER.
* 
* 
* FMC       HNS 80/06/17
* 
*         FMC01 - DIAGNOSTIC ISOLATION OF 7155-A16-1A38.
*         DPSR 036108 
* 
* 
* D88       HNS 80/02/27
* 
*         D8813 - ID-SWITCH MESSAGE 
*         DPSR 037614 
* 
* 
* FMD       HNS 80/02/27
* 
*         FMD01 - ID-SWITCH MESSAGE 
*         DPSR 037603 
* 
* 
* FMD       HNS 80/06/17
* 
*         FMD27 - FAILS WITH NON-ZERO I. D. SWITCH. 
*         DPSR 037604 
* 
* 
* FMC       HNS 80/02/27
* 
*         FMC33 - ID-SWITCH MESSAGE 
*         DPSR 037612 
* 
* 
* FMD       HNS 80/06/17
* 
*         FMD32 - FAILS WITH A NON-ZERO I. D. SWITCH. 
*         DPSR 037605 
* 
* 
* HPA4    SLJ  80/05/16 
* 
*         CORRECTS PROBLEM OF INCORRECT 7-DAY AND 30-DAY AVERAGES ON
*         SYSTEM PERFORMANCE SUMMARY WHEN THE YEAR CHANGES. 
* 
* 
* MALET30 JMO    80/06/24 
*         MODSET CORRECTS THE PROBLEM OF PARAMETER ERRORS ON A MALET
*         CONTROL CARD THAT ARE COMMENTS AFTER A PERIOD. DPSR 019989. 
* 
* 
*        DPSR 025408
* HPA    REF  07/03/80
*        MODSET CORRECTS THE TAPE DENSITY SUMMARY LABELS ON HPA UNIT
*        ANALYSIS REPORTS TO ACCURATELY REFLECT 7 OR 9 TRACK TAPES. 
* 
* 
* HPA     TEF   80/07/11
*         MODSET HPA03591 ADDS MMF PARAMETER AND CODE TO CHANGE 
*         SORT ORDER FROM EST TO HUID IF SELECTED 
* 
* HPA3     PWL  80/07/22
*          MODSET HPA035648 CORRECTS DISK UNIT NUMBER 
*          IN UNIT ANALYSIS REPORT. 
* 
* 
* HISTORY  DJU    80/07/28
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL118PL.
* 
* 
* HPA1    TEF  80/07/29 
* HPA2    MODSET HPA035931 ADDS CAPABILITY TO MATCH ON PARTS OF THE 
*         HARDWARE CONFIGURATION TABLE TO MMF.
* 
* 
* HPA     JLP 80/07/29
*         THIS MODSET (HPA035696) ADDS EXTENDED DETAIL STATUS 
*         ANALYSIS FOR 844'S ON 7155 CONTROLLERS, USING THE 
*         SEF CONTINUATION RECORDS FOR 844'S. IT ALSO ALLOWS
*         THE DLT EDITOR TO SPECIFY THAT THE ORIGINAL O/S ERROR 
*         CODE IS TO REMAIN UNCHANGED.
* 
* 
* HPA5     PWL  80/05/19
*          MODSET CORRECTS DATE IN SUMMARY REPORT 1.
* 
* 
* FMC       HNS 80/07/02
* 
*         FMC - CAUSES UNIT RESERVED/SYSTEM HANGS 
*         DPSR 001900 
* 
* 
* FMC       HNS 80/05/19
* 
*         FMC31 - BYPASS FMC31 UNLESS ENABLED (P4=XXX1) 
*         DPSR 033196 
* 
* 
* T6X     JES    79/12/04 
*         MODSET ADDS COMPATIBILITY TEST (T6X80) AND COMPATIBILITY
*         TAPE CLEAN-UP (T6X81).  THESE MODULES ARE COMPATIBLE WITH 
*         THE SAME MODULES IN T5X AND T7X IN ORDER TO ALLOW TESTING 
*         OF COMPATIBILITY BETWEEN 60X, 65X, 66X AND 67X TRANSPORTS.
*         DPSR 035908 
* 
* 
* DDN     80/07/10
*         MODSET ENSURES CORRECT RECORD AND FILE
*         COUNTS ON A READ REV.  MODULES 45A AND 57A. 
*         DPSR 037669 
* 
* 
* HISTORY  RBD    80/08/04
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL119PL.
* 
* 
*        DPSR 035939
*        REF  07/22/80
*        MODSET CORRECTS THE PROGRAM FLOW IN HPA5 AS FOLLOWS: 
*        1) ELIMINATES MEANINGLESS HEADERS FOR SUMMARY REPORTS 1 & 2
*           OF ERROR LOG ENTRIES IF NO SEF INPUT FILE.  ONLY THE
*           COMMENT "TOTAL ENTRIES = 0" WILL APPEAR.
*        2) ELIMINATES SYSTEM MESSAGE SUMMARY HEADER FROM ERROR LOG 
*           SUMMARY 2 REPORT IF NO SYSTEM MESSAGES. 
*        3) ENABLES THE PARAMETER SELECTION OF GRAPHS WITHOUT THE 
*           SELECTION OF SUMMARY REPORTS.  INVALID DATA FORMERLY
*           OCCURRED, DUE TO ARRAYS NOT BEING PROPERLY CLEARED. 
*        4) ELIMINATES DATES FROM GRAPHS FOR DAYS WHEN DATA EXISTS
*           BUT IS TOO MINIMAL TO BE GRAPHED. 
*        5) ENABLES A MAXIMUM OF 194 UNIT ERROR GRAPHS.  FORMERLY, A
*           LIMIT OF 100 UNIT ERROR RECORDS WERE SEARCHED FOR GRAPH DATA
*           AND THE DATA WAS STORED UNPACKED.  NOT ALL DEVICE TYPES WERE
*           GRAPHED WITH THIS LIMIT.  NOW, (MAX. OF 194) GRAPHS WILL
*           RESULT FOR ALL DEVICE TYPES THAT CONTAIN 30 DAY DATA. 
* 
* 
* T7X     JES    79/12/04 
*         MODSET ADDS COMPATIBILITY TEST (T7X80) AND COMPATIBILITY
*         TAPE CLEAN-UP (T7X81).  THESE MODULES ARE COMPATIBLE WITH 
*         THE SAME MODULES IN T5X AND T6X IN ORDER TO ALLOW TESTING 
*         OF COMPATIBILITY BETWEEN 60X, 65X, 66X AND 67X TRANSPORTS.
*         DPSR 035907 
* 
* 
* T5X     JES    79/12/04 
*         MODSET ADDS COMPATIBILITY TEST (T5X80) AND COMPATIBILITY
*         TAPE CLEAN-UP (T5X81).  THESE MODULES ARE COMPATIBLE WITH 
*         THE SAME MODULES IN T6X AND T7X IN ORDER TO ALLOW TESTING 
*         OF COMPATIBILITY BETWEEN 60X, 65X, 66X AND 67X TRANSPORTS.
*         DPSR 035910 
* 
* 
* HPA3    SLS  80/07/30 
* 
*         CORRECTS THE PROBLEM OF THE PROGRAM CAPTURES ONLY THE FIRST 
*         FIRMWARE REVISION NUMBER. 
* 
* 
* HPA35    SLS  80/07/30
* 
*         CORRECTS  PROBLEM OF CALLING HEX3 TWICE WHEN RUNNING
*         DETAIL CS.
* 
* 
* T6X     DDN    80/07/01 
*         MODSET WAS GENERATED TO ENSURE 500 WORDS WERE WRITTEN 
*         TO THE OUTPUT BUFFER ON A DUP STATEMENT.  MODULES 
*         AFFECTED ARE 01,02,03,10,11,12,13,18,201 AND 32.
*         DPSR 034200.
* 
* 
*   HPA      SLJ     80/07/17 
* 
*            CORRECTS PROBLEM OF NOT MERGING SEF RECORDS INTO 
*            ONE HISTORY RECORD WHEN BOTH SEFS ARE FOR THE SAME 
*            DAY. 
* 
* HPA36   SLS  80/07/28 
* 
*         CORRECTS PROBLEM OF SYNDROME CODE 004 PRINTING OUT AS A 
*         DOUBLE BIT ERROR WHEN IT IS A BIT 62 ERROR. 
* 
* 
* HPA36   SLJ  80/07/10 
* 
* 
*         CORRECTS PROBLEM OF ANALYSIS REPORT LISTING TOO MANY BANKS
* 
* FMD       HNS 80/07/09
* 
*         FMD - FMD27 - DIAG ISOLATION OF MAINT. SWITCH. (DEMO) 
*         DPSR 036118 
* 
* 
* HPA7     PWL  80/07/18
*          MODSET INSTALLS CODE TO SKIP THE READING OF HISTORY
*          FILES IF NO HISTORY PARAMETERS ARE CALLED FOR. 
* 
* 
* HPA2     PWL  80/07/10
* COMHPAERT  MODSET INSTALLS CODE TO PROCESS "POWER FAILURE", 
* HPA7     "POWER/ENVIRONMENT NORMAL", "SHUTDOWN IMMINENT"
*          AND 174-2X MESSAGE.
* 
* 
*        DPSR 036626
* HPA    REF  07/21/80
*        MODSET CORRECTS THE CHECKING OF ATS DETAIL STATUS BITS 
*        FOR DETERMINATION OF TAPE CONTROLLER PARITY ERRORS FROM
*        NOS/NORM.  (NOS-BE/NORMS PRESETS TCU ERRORS.)  WHEN DETECTED,
*        TCU ERRORS WILL BE REPORTED FOR CHECK-OUT IN THE INTERVENTION
*        REPORT.
* 
* 
* HPA3    SLS  80/07/30 
* 
*         CORRECTS FORMAT SPACING PROBLEM IN CS ANALYSIS REPORT.
* 
* 
* HPA1    SLJ  80/07/15 
* 
* 
*         CORRECTS PROBLEM OF CARRYING ALONG SHRS FROM THE OLDHF
*         INSTEAD OF CREATING NEW SHRS FOR ONLY THE DATA
*         EXTRACTED BY THE HR( HISTORY READ ).
* 
* HISTORY  DJU    80/08/25
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL119FC.
* 
* 
* MAL     GDW    80/08/28 
*         MODSET CORRECTS PROBLEM IN MALET FOR
*         WHICH IT DOES NOT RETURN DEVICE TO
*         SYSTEM WITH A CVL CALL WHEN A DROP
*         DIRECTIVE IS DONE.
*         PROBLEM REPORTED BY DPSR 035670.
* 
* 
* FMD       HNS 80/08/07
* 
*         FMD - FMD32 FAILS WHEN SYS. MAINT. SWITCH IS OFF. 
*         DPSR 031653 
* 
* 
* FMD       HNS 80/07/30
* 
*         FMD - FAILS ON DEVICE USED BY SYSTEM. 
*         1.PRE-POSITION SERVO (FMD35)
*         2.HAVE RES COMMAND WAIT-NOT-BUSY (FMD15/MLD)
*         3.REMOVE UN-NEEDED RES (FMD17)
*         4.MOVE SEEK SEQUENCE TO BEGINNING OF COND.(FMD70) 
*         5.LOAD CYL REG AND RTZ BEFORE ERR MSG (FMD36-40)
*           (THIS PREVENTS FMD CAUSED SYSTEM ERRORS)
*         6.CORRECT R/W CHECK TEST TO IGNORE UNUSED BITS(FMD66).
*         DPSR 037106 
* 
* 
* MALET11 JMO    80/08/04 
*         MODSET CORRECTS THE PROBLEM OF NOT BEING ABLE TO
*         DROP MALET ON THE FIRST TRY. PROBLEM WAS INTRODUCED 
*         BY MODSET MAL036104. DPSR 035651. 
* 
* HPA1    SLS  80/08/13 
* 
*         CORRECTS PROBLEM OF NOT REPORTING SECOND DATE OR NUMBER 
*         OF DAYS FOR THE HISTORY READ PARAMETER IN THE REPORTS 
*         CALLED SECTION. 
* 
* 
* HPA3     PWL  80/08/21
* HPA35    MODSET HPA031970 CORRECTS "PORTS ACTIVE VS.
*          HOUR OF DAY" GRAPH.
* 
* 
* HISTORY  AKJ    80/09/10
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL120PL.
* 
* 
*         DPSR 037822 
* HPA     REF  09/02/80 
*         MODSET CORRECTS A MAL-FUNCTIONING SORT WHICH RESULTED IN THE
*         IMPROPER ORDERING OF MESSAGE TYPES IN THE DETAIL REPORTS.  AN 
*         ERRONEOUS SORT KEY WAS PULLING OFF TOO MANY CHARACTERS. 
* 
* 
* MALET12 GLG    80/09/16.
*         MODSET CORRECTS MALET TO PASS EOR STATUS ON SYSRD 
*         COMMANDS IF NO WORDS ARE READ.  PREOBLEM REPORTED 
*         BY DPSR 37834.
* 
* 
* HPA2    DDN    80/08/18 
*         MODSET DISABLES COMPRESSION OF 607 AND 65X
*         ERRORS WITH A BLOCK COUNT OF ZERO.
*         DPSR 034577 
* 
* 
* FMC       HNS 80/08/20
* 
*         FMC31 - DISK AUTOLOAD PARAMETER FAILURE 
*         DPSR 031631 
* 
* 
* DTC       HNS 80/08/26
* 
*         DTC12-16 - LACK INITIAL MESSAGE ON TERMINAL 
*         DPSR 031638 
* 
* 
* FMC       HNS 80/07/02
* 
*         FMC25/29/31/33 - ADD LF TO UNEXPECTED ERROR MESSAGES
*         DPSR 031650 
* 
* 
* DTC       HNS 80/08/27
* 
*         DTC - FALSE ERROR REPORTING 
*         DPSR 034171 
* 
* 
* MAL     GDW    80/08/22 
*         MODSET CORRECTS PROBLEM IN MALET WHICH
*         PRODUCES THE WRONG DAYFILE MESSAGE WHEN 
*         AN INCORRECT DEVICE CODE IS SUPPLIED
*         WITH THE ASSIGN DIRECTIVE.
*         PROBLEM REPORTED BY DPSR 035929.
* 
* 
* MAL     GDW    80/09/15 
*         MODSET PERMITS MALET TO PRINT CORRECT 
*         MESSAGE WHEN CONTINUED RUN DIRECTIVE
*         IS USED.
*         PROBLEM REPORTED BY DPSR 035652.
* 
* 
* RT5     DDN    80/09/10 
*         MODSET CHANGES THE EXTERNAL DOCUMENTATION AND MODULE
*         99 TO SPECIFY D IN P0 AND P1 PORT SELECT. 
*         DPSR 016449 
* 
* 
* FMC       HNS 80/07/02
* 
*         FMC33 - ADD DETAIL STATUS TO UNEXPECTED ERROR 
*         DPSR 033197 
* 
* 
* HPA,HPA1   PWL  80/09/16
* HPA4,HPA7  MODSET HPA037836 ADDS "DATE" PARAMETER (DATE=
*            MMDDYY) TO HPA CONTROL CARD TO ENABLE THE
*            CHANGE OF RUN DATE.
* 
* 
* HPA3     PWL  80/09/15
* HPA35    MODSET HPA032044 CHANGES THE ERROR SCALE GRADUATION
*          BETWEEN PAGES TO BE CONSISTENT WHEN ERROR VS LOGICAL 
*          PORT GRAPH IS CONTINUED TO A SECOND PAGE.
*          IT CHANGES THE USAGE SCALE GRADUATION TOO TO BE
*          CONSISTENT BETWEEN PAGES.
*          IT ALSO CORRECTS THE ERROR GRAPH TO EXCLUDE THE
*          STATISTICAL DATA.
* 
* 
* FMC       HNS 80/08/08
* 
*         FMC - LF NOT DISPLAYED ON UNEXPECTED ERROR. 
*         DPSR 031652 
* 
* 
* HISTORY  AKJ    80/10/06
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL121PL.
* 
* 
* HPA1    SLS  80/10/08 
*         CORRECTS PROBLEM OF HPA NOT RECOGNIZING THE EXISTENCE 
*         OF THE SEF FILE THAT IS CREATED WHEN USING THE HR 
*         PARAMETER.
* 
* 
* INSTLDKS       JMO    80/09/30
*         MODSET CORRECTS THE INSTALL DECK FOR NOSBE R4 AND R5 TO 
*         FIX THE FIELD LENGTH ON TIO WHICH IS TOO SMALL. 
*         DPSR 037865.
* 
* 
* FMC       HNS 80/09/15
* 
*         FMC - DESCRIPTION 
*         DPSR 036131 
* 
* 
* MALET11 GLG    80/09/26.
*         MODSET CORRECTS MALET11 TO TEST ACCESS LEVEL TO SEE IF
*         IT IS LEGAL.
* 
* 
*         DPSR 037803 
* HPA     REF  09/26/80 
*         MODSET CORRECTS THE SYSTEM PERFORMANCE SUMMARY REPORT (S3)
*         BY INCLUDING DATA FOR THE SCR (SR DEVICE TYPE).  PREVIOUSLY,
*         SCR INFORMATION WAS OMITTED FROM BOTH SECTIONS OF THE S3
*         HISTORICAL SUMMARY, WHICH PROVIDES THE MTBF ERROR RATES BY
*         DEVICE TYPE/EST.
* 
* 
* MLT     KM     80/10/2
*         FIXES THE SPELLING ERROR IN 
*         THE WORD LICENSE IN MLTDOC
*         OUTPUT. 
* 
* HPA35    PWL  80/09/30
*          MODSET HPA032040 CORRECTS THE PROCESSING OF
*          2550 I5 STATISTICS.
* 
* 
* D88       HNS/RFF 80/09/29
* 
*         D88 - PRESERVICE FORECAST GROUP INCORRECT.
*         1. ISOLATION OF 7155-BO4-TP16 (BUSOUT 4). 
*         2. ISOLATION OF 7155-B04-TP14 (BUSOUT 6). 
*         3. ISOLATION OF 7155-A20-1B04 (NOC 1/15, LOOP BUS). 
*         4. ISOLATION OF 7155-B21-1A17 (DRIVE SAFE NIC 1/6). 
*         5. ADDITION OF D8812 (DRIVE BUS OUT TEST).
*         6. UPDATED DOCUMENTATION FOR D8812. 
*         7. ERROR PROCESSORS CORRECTED TO GIVE EACH ISOLATION
*            MESSAGE ITS OWN PSFG.
*         DPSR 034905 
* 
* 
* FMC       HNS 80/09/03
* 
*         FMC - DETECT/ISOLATE REQUIREMENTS NOT MET.
*         1. ADD SELECT/RESERVED CHECK TO FMC29 (B01-2A41). 
*         2. CORRECT PRESERVICE FORECAST GROUP FOR FMC25. 
*         3. ADD DRIVE RESERVED BY OPPOSITE ACCESS TO FMC25(B04-1B31).
*         4. ADD ADDRESS ERROR CHECK TO FMC29 (A20-1A09). 
*         DPSR 034906 
* 
* 
* MALET   GLG    79/09/20.
* MALETP4 MODSET DELETES DIAGRD AND DIAGWR FROM 844HT AND FMDHT 
* MALETP9 COMPILER AND ADDS PROTECTION TO OUT AND CONTROL 
* MALET20 COMMANDS FOR ACCESS LEVEL PRIVILEGES THAT COULD BE
* MALCD2  ABUSED THROUGH MISUSE.
* 
* 
* D44     GLG    80/10/03.
*         MODSET CORRECTS D44 FOR DIAGRD AND DIAGWR COMMANDS BEING
*         REMOVED BY MAL037868.  MODULE D4403 HAD TO CHANGE LANGUAGES 
*         BEING USED ON THE MODULE CARD FROM 844HT TO 844FT.
* 
* 
* FMC       HNS 80/05/19
* 
*         FMC15 - DIAGNOSTIC ISOLATION OF 7155-A02-1A20 (DEMO)
*         DPSR 036113 
* 
* 
*         DPSR 037878 
* HPA     REF  10/16/80 
*         MODSET CORRECTS A FATAL ARITHMETIC OVERFLOW IN THE HPA SITE 
*         MANAGEMENT REPORT, RUNNING WITH DEBUG, WHICH WAS CAUSED BY
*         AN UNINITIALIZED VARIABLE FLAG.  THE ERROR CONDITION WAS
*         TRIGGERED BY PARAMETER SELECTION OF THE SITE MANAGEMENT GRAPH 
*         WITHOUT ALSO SELECTING THE SITE MANAGEMENT ANALYSIS REPORT. 
* 
* 
*         DPSR 037817 
* HPA     REF  09/26/80 
*         MODSET REMOVES AN ILLEGAL CARRIAGE CONTROL CHARACTER FROM 
*         THE TAPE MEDIA DETAIL REPORT.  THIS ILLEGAL CHARACTER (:) 
*         WAS NOT DISCERNIBLE WHEN HPA WAS OUTPUT ON THE NOS SYSTEM,
*         BUT IT CAUSED PROBLEMS ON THE MICROFICHE SYSTEM.
* 
* 
* HPA35    PWL  80/10/14
*          MODSET HPA035656 DELETES MEANINGLESS CLA STATUS
*          AND CLOCK STATUS INFORMATION 
* 
* 
* FMD       HNS/RFF 80/10/28
* 
*         FMD - DETECTION/ISOLATION REQ. NOT MET. 
*         DPSR 034908 
* 
* 
* HPA3     PWL  80/10/20
*          MODSET HPA025746 CORRECTS TAPE UNIT NUMBER 
* 
* 
* FMD       HNS 80/10/20
* 
*         FMD63-65 FAIL AT AL=3 (INTERNAL)
*         1. ADD SEEK TO FMD63. 
*         2. ADD AL.LE.3 BYPASS TO FMD64-65.
*         3. REDUCE SIZE OF FMD64.
*         DPSR 037869 
* 
* 
* HISTORY  AKJ    80/11/03
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL122PL.
* 
* 
* T7X     JES    80/11/06 
*         MODULES T7X03 AND T7X04 FAIL WITH A CONTROLWARE ERROR 
*         CW4030 WRITE ATTEMPTED AT 200 BPI DENSITY IF T7X IS RUN 
*         ON A 9TK UNIT AND THE LAST 7TK UNIT USED BY THE OPERATING 
*         SYSTEM WAS SELECTED FOR 200BPI.  THERE IS NO WAY FOR T7X
*         TO SELECT 7TK DENSITY FOR THE TCU LOOPBACK DONE BY MODULES
*         03 AND 04 IF A 9TK UNIT IS BEING TESTED, AND 200 BPI WRITE
*         ON A 7TK IS ILLEGAL.  THIS MODSET SKIPS TESTING OF 7TK NRZI 
*         ON TCU LOOPBACK OPERATIONS IF A 9TK UNIT IS ASSIGNED. 
*         DPSR 8113.  DPSR 40106. 
* 
* 
* T5X     JES    80/10/17 
*         MODSET CORRECTS CAPSTAN VALVE TEST (MODULE 21D) SO THAT 
*         IT CAN DETECT A UNIQUE FAILURE MODE OF THE FORWARD CAPSTAN
*         (PLOTS ARE GOOD BUT UNIT IS CREATING SHORT GAPS ON TAPE 
*         THAT CANNOT BE HANDLED BY 66X AND 67X UNITS).  A WARNING
*         MESSAGE IS ISSUED IF SHORT GAPS ARE BEING CREATED.
* 
* 
* MAL     GDW    80/10/16 
*         MODSET PERMITS MALET TO ASSIGN BOTH MST AND CSU 
*         WHEN THE MSS EXECUTIVE IS RUNNING.
*         PROBLEM REPORTED BY DPSR 037875.
* 
* 
* DTC       HNS 80/10/21
* 
*         DTC - FAILS AT AL=3.
*         1. ADD ACCESS LEVEL CHECK AND MESSAGE TO DTC18. 
*         2. REMOVE EXTRA RES COMMAND FROM DTC03. 
*         3. REMOVE RES FROM WRITE PATTERN LOOP IN DTC03. 
*         4. REMOVE UNNECESSARY DELAY AND MESSAGE FROM DTC03. 
*         5. ADD RTZ SEEK SUBROUTINE AND APPROPRIATE CALLS(DTC03).
*         6. REMOVE UNNECESSARY RES COMMANDS(DTC03,06,07,08,09, 
*            11,12,14,16,18). 
*         7. MOVE SEEK TIME MESSAGES (DTC09). 
*         8. ADD CLEAR FAULTS COMMAND TO DTC17. 
*         DPSR 037870 
* 
* 
* DTC       HNS 80/08/22
* 
*         DTC02 - INCORRECT ERROR 
*         1. REMOVE UNNECESSARY DELAYS AND MESSAGES.
*         2. ADD RTZ SEEKS TO CLEAR DRIVE FOR OS. 
*         3. ADD RTZ TEST TO DTC01. 
*         4. CORRECT DTC02 TO RUN AL=3. 
*         5. FIX BUGS IN ERROR REPORTING. 
*         6. REDUCE LENGTH OF DTC02.
*         DPSR 023798 
* 
* 
* MAL     GDW    80/10/16 
*         MODSET PERMITS MALET TO RETURN THE DEVICE TO THE
*         SYSTEM WHEN THE DEVICE CODE IS 100 OR 101 OCTAL.
*         PROBLEM REPORTED BY DPSR O37867.
* 
* 
* DTC       HNS 80/10/28
* 
*         DTC16 - LANGUAGE CHANGE ERROR.
*         DPSR 031654 
* 
* 
* HPA3    SLS  80/10/23 
*         CORRECTS PROBLEM OF UNINITIALIZED VARIABLE - SERDATE
*         THIS VARIABLE AFFECTED CYBERAMA PROCESSING. 
* 
* 
* HPA3     PWL  80/10/21
* HPA35    MODSET HPA024340 PRINTS CHANNEL, EQUIPMENT AND 
*          UNIT NUMBERS FOR 2550 I5 REPORTS, NODE NUMBER
*          FOR 2550 NAM REPORTS.
* 
* 
* DTC       HNS 80/10/23
* 
*         DTC - HAS UNNECESSARY DELAYS AND MESSAGES.
*         1. REMOVE DELAYS AND MESSAGES(DTC01,04,05,09,11,19).
*         2. CORRECT DOCUMENTED RUN TIMES.(DTC99B)
*         DPSR 031639 
* 
* 
* JMO     80/11/03
*         MODSET INSERTS CONDITIONS INTO THE DOCUMENTATION FOR
*         RUNNING EVEN PARITY ON A 7 TRACK UNIT. DPSR 035600. 
* 
* 
* FMC       HNS 80/10/30
* 
*         FMC ATTEMPTS FMC35 WHEN P5=1. 
*         DPSR 031648 
* 
* 
* FMC       HNS 80/11/07
* 
*         FMC25 - DIAG ISOLATION OF 7155-B01-1B22. (DEMO) 
*         1. ADD DRIVE MALFUNCTION ERROR CHECK. 
*         2. REDUCE MEMORY REQ. FOR FMC25(IMPLEMENT CGS SUB). 
*         3. REDUCE NUMBER OF STATEMENTS IN FMC25.
*         4. IMPLEMENT ECWS SUBROUTINE IN FMC25.
*         5. IMPLEMENT IPCS SUBROUTINE IN FMC25.
*         DPSR 036116 
* 
* 
* HISTORY  AKJ    80/12/03
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL123PL.
* 
* 
* ATC     JMO    80/11/06 
*         MODSET CORRECTS PROBLEMS ON MODULES 30 32 36 AND 37 
*         WHEN RUNNING ON 100 IP DRIVES AND A CYBER 74. 
*         DPSR 035595.
* 
* 
* DTC       HNS 80/11/24
* 
*         DTC13/14 ISSUE WRONG MESSAGE. 
*         DPSR 015680 
* 
* 
* HPA4    SLS  80/11/10 
*         CORRECTS PROBLEM OF HPA NOT ALLOWING A ZERO TO BE ENTERED 
*         FOR OPT TIME HOURS OR FRACTION OF AN HOUR.
* 
* 
* FMC       HNS 80/11/24
* 
*         FMC35 CALLS NON-EXISTENT MODULES
*         DPSR 037910 
* 
* 
* T7X     JES    80/11/06 
*         MODULES T7X03 AND T7X04 FAIL ON A WRITE OPERATION WITH ALL
*         DATA NOT ACCEPTED FROM PP ON A CYBER 70 SYSTEM WITH EXTERNAL
*         DATA CHANNELS IF THE 67X CONTROLLER IS ATTACHED TO A SINGLE 
*         RANK CHANNEL AND A 7TK TRANSPORT IS BEING TESTED.  THE ERROR
*         IS CAUSED BY LOST DATA SINCE THE CHANNEL CANNOT KEEP UP WITH
*         THE EXPECTED SPEED AT 6250 BPI TCU LOOPBACK 6-BIT MODE.  IT 
*         WORKS OK IF A 9TK UNIT IS ASSIGNED IN PACKED MODE. THIS 
*         MODSET ENSURES THAT 200 IPS GCR DENSITY IS NOT USED IN TCU
*         LOOPBACK MODE IF A 7TK UNIT IS ASSIGNED.
*         DPSR 40105. 
* 
* 
* T7X     JMO    80/12/02 
*         MODSET CORRECTS THE PROBLEM IN T7X MODULE 22 (PARK COUNTS)
*         OF CONTINUALLY RUNNING WITHOUT ANY ERROR INDICATION IF NO 
*         DATA CAN BE READ FROM THE TAPE. DPSR 029894.
* 
* 
* T6X     DDN    80/11/20 
*         MODSET ADDS A 1000D MSEC DELAY IN MODULE
*         30 TO ENSURE THE PLOTS ARE DISPLAYED FOR
*         DEMOT.
*         DPSR 22992. 
* 
* 
* FMC       HNS 80/11/24
* 
*         FMC27 CALLS FMC250/25A. 
*         DPSR 037909 
* 
* 
* FMC       HNS 80/11/26
* 
*         FMC25 - DIAGNOSTIC ISOLATION OF 885-B28-22A(DEMO) 
*         DPSR 036121 
* 
* 
* D88       HNS 80/11/26
* 
*         D88 - DIAGNOSTIC ISOLATION OF 7155-A12-1B13(DEMO) 
*         DPSR 036111 
* 
* 
* FMC       HNS 80/05/19
* 
*         FMC29 - DIAGNOSTIC ISOLATION OF 7155-A12-1B13.
*         DPSR 036111 
* 
* 
* HPA35    PWL  80/11/14
*          MODSET HPA037893 REPORTS 2550 CE ERROR MESSAGES
*          "MODE 4 AUTO RECOGNITION FAILED", "NO RESPONSE,
*          BAD RESPONSE, ERROR RESPONSE FROM MODE 4 TER-
*          MINAL" AND "BAD FRAME DETECTED BY CRC", CORRECTS 
*          THE REPORTING OF ERRORS DETECTED BY 2550 NAM.
* 
* 
* T7X     DDN    80/12/08 
*         MODSET CORRECTS AN ERRONEOUS LINE INSERTED
*         BY MODSET T7X40106. 
*         DPSR 035946.
* 
* 
* D88       HNS 80/11/18
* 
*         D88 - DIAGNOSTIC ISOLATION OF 7155-B19-2B04 (DEMO)
*         DPSR 036114 
* 
* 
*FMU      ALJ  80/11/04 
*         FMU05 AND FMU06 WERE MODIFIED TO CHECK THE ACCESS LEVEL BEFORE
*         CHANGING THE FLAW MAPS.  THIS INSURES THAT THE ACCESS LEVEL IS
*         HIGH ENOUGH TO ALLOW FORMATTING THE TRACK AFTER THE MAPS HAVE 
*         BEEN CHANGED. 
* 
* 
*FMU      ALJ  80/11/04 
*         A NOTE WAS ADDED TO THE EXTERNAL DOCUMENTATION FOR FMU14 TO 
*         WARN THAT FORMATTING THE UTILITY TRACK DESTROYS THE UTILITY 
*         FLAW MAP. 
* 
* 
*FMU      ALJ  80/11/04 
*         FMU15 WAS MODIFIED TO ELIMINATE THE POSSIBILITY OF RELEASING
*         THE CONTROLLER BETWEEN SCANNING AND READING THE RESULTS OF
*         THE SCAN FROM THE BUFFER.  THIS PREVENTS THE OPERATING SYSTEM 
*         FROM ASSIGNING THE CONTROLLER TO ANOTHER JOB UNTIL AFTER THE
*         RESULTS OF THE SCAN HAVE BEEN OBTAINED BY FMU15.
* 
* 
*FMU      ALJ  80/11/04 
*         FMU00, FMU40, AND FMU99 WERE DELETED.  A NEW FMU99 MODULE WAS 
*         ADDED ALONG WITH FMU99A.  THESE CHANGES WERE MADE TO CONFORM
*         TO CURRENT PRACTICE FOR DISPLAYING THE PARAMETER LIST AND 
*         MODULES LIST. 
* 
* 
*FMU      ALJ  80/11/04 
*         FMU41, FMU42, FMU43, FMU45, FMU46, FMU47, FMU50, FMU51, FMU52 
*         FMU53, FMU54, FMU55, FMU57, FMU60, AND FMU98C WERE MODIFIED 
*         TO SEND AN OPERATION COMPLETE FUNCTION BEFORE RELEASING THE 
*         CONTROLLER.  IF THIS FUNCTION IS NOT SENT THE CHANNEL REMAINS 
*         RESERVED IN THE CONTROLLER.  FMU55 WAS ALSO MODIFIED TO 
*         RELEASE THE CONTROLLER WHILE SCAN RESULTS ARE ANALYZED AND
*         DISPLAYED.
* 
*         FMU511 WAS MODIFIED TO RELEASE THE CONTROLLER WHILE WAITING 
*         FOR FORMATTING TO COMPLETE.  THIS IS NECESSARY TO PREVENT A 
*         2 SECOND TIMEOUT FROM OCCURRING.  NORMALLY FORMATTING ONLY
*         REQUIRES 0.5 SECONDS PER CYLINDER, HOWEVER, AFTER FORMATTING
*         CYLINDER 822 THE CONTROLLER SETS TRACK AND SECTOR FLAWS.
*         THIS COULD REQUIRE UP TO 15 SECONDS DEPENDING ON THE NUMBER 
*         OF FLAWS.  TYPICALLY UP TO 30 FLAWS WILL REQUIRE LESS THAN
*         2 SECONDS TO FORMAT CYLINDER 822 AND SET FLAWS. 
* 
* 
* HISTORY  AKJ    81/01/07
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL124PL.
* 
* 
* HPA2    SLS  80/09/02 
* 
*        CORRECTS PROBLEMS IN HPSORT ROUTINES.
* 
* 
* MALET10 GLG    80/12/18.
*         MODSET CHANGES SEND COMMAND TO FLASH ON THE DISPLAY IF
*         THE OPERATING SYSTEM IS NOSBE OR NOS(LEVEL 528).
*         PROBLEM REPORTED ON DPSR 1354 AS AN ENHANCEMENT TO MALET. 
* 
* 
* MALET11 GLG    80/12/17.
*         MODSET ADDS A NEW PARAMETER TO THE MALET ASSIGN DIRECTIVE 
*         THAT IS REQUIRED IF THE DEVICE IS NOT IN THE EST TABLE. 
*         EST=NO IS REQUIRED ON THE ASSIGN DIRECTIVE IF THE DEVICE
*         IS NOT DEFINED WITHIN THE SYSTEM EST TABLE. 
* 
* 
* FMC       HNS 80/09/23
* 
*         FMC - DIAGNOSTIC ISOLATION OF 7155-B20-2A25. (DEMO) 
*         1. CORRECT BUGS IN FMC17 TO ATTEMPT NIC2/9 TEST.
*         2. ADD FMC26, FMC26A, FMC260, TO TEST ADDRESSES.
*         DPSR 036112 
* 
* 
* FMD       HNS 81/01/07
* 
*         FMD02 BAD ISOLATION ON 885-A/B11. (MFG) 
*         DPSR 037938 
* 
* 
* FMD       HNS 80/12/02
* 
*         FMD06/09 - DIAGNOSTIC ISOLATION OF 885-B15-30B.(DEMO) 
*         1. ADDS TWO NEW MODULES (FMD96W,FMD96X) 
*         2. ADD PWB(S) A/B22,A/B15,A/B16,A/B23,A/B28,A/B20D TO 
*            SELECTED ISOLATION MESSAGES. 
*         3. FIX FORMAT 6 TYPO IN FMD982. 
*         4. CORRECT BUG IN FMD36.
*         DPSR 036123 
* 
* 
* MAL     GDW    80/10/28 
*         MODSET CHANGES MALET TO REQUIRE CH, UN AND EQ 
*         IF EST OR MNE ARE NOT PROVIDED. 
*         PROBLEM REPORTED BY DPSR 034580.
* 
* 
* FMC       HNS 80/12/19
* 
*         FMC02 NEVER FAILS WITH P5 = 1000. 
*         DPSR 027163 
* 
* 
* FMD       HNS 81/01/07
* 
*         FMD01 BAD ISOLATION ON 885-A/B11. (MFG) 
*         DPSR 037941 
* 
* 
* FMD       HNS 81/01/12
* 
*         FMD73 WONT RUN ON-LINE. (BOEING)
*         DPSR 037162 
* 
* 
* FMD       HNS 81/01/12
* 
*         FMD DIAG. FAILS TO DETECT OPEN CABLE DETECT. (UWASH)
*         DPSR 037169 
* 
* 
*          TEF, PWL  80/12/16 
* HPA38    MODSET HPA037815 GENERATES A SEPARATE DETAIL 
*          REPORT FOR A170 IOU ERRORS.
* 
* 
* HPA38    TEF, PWL  80/12/16 
*          MODSET HPA037816 SEPARATES CALLS TO THE A170 
*          ANALYSIS REPORTS FROM THE DETAIL REPORTS, COM- 
*          BINES PROCESSOR, IOU AND MEMORY ERRORS FOR THE 
*          MESSAGE DISTRIBUTION REPORT. 
* 
* 
* HPA38    TEF, PWL  80/12/16 
*          MODSET HPA035671 INCLUDES REGISTERS 12 AND 81 IN 
*          A170 PROCESSOR DETAIL REPORT, CHECKS PAGE OVER-
*          FLOW, AND CORRECTS THE DESCRIPTION OF REGISTER 80. 
* 
* 
* HPA38    TEF, PWL  80/12/15 
*          MODSET HPA035657 CORRECTS DATE IN A170 DETAIL REPORTS. 
* 
* 
* HPA38    TEF, PWL  80/12/16 
*          MODSET HPA037814 CORRECTS THE REPORTING OF 
*          REGISTERS TO INCLUDE REGISTER 12.
* 
* 
* FMC       HNS 80/12/29
* 
*         FMC DOESNT DETECT INPUT PARITY ERRORS.
*         1. ADD INPUT DATA PARITY CHECK TO FMC08.
*         2. ADD INPUT DATA PARITY CHECK TO FMC09.
*         DPSR 037940 
* 
* REGEN   GLG    81/01/16.
*         MODSET CORRECTS REGEN TO ALLOW IT TO RUN A CYBER 170
*         MODEL 835.  THE MODSET DELETES THE USE OF 660XX AND 
*         670XX INSTRUCTIONS FROM THE DATA GENERATED BY ALX AND FST 
*         CPU TESTS WHICH ARE PART OF REGEN. OLD MASTER TAPES 
*         NEED RE-CREATION FOR RUNS AFTER MODSET IS INSTALLED.
* 
* 
* MALET12 JMO    81/01/16 
*         MODSET CORRECTS INTERNAL DOCUMENTATION IN 
*         MALET12. DPSR 040071. 
* 
* 
* T7X     JMO    81/01/12 
*         THIS MODSET MODIFIES MODULE 60 OF T7X (LADDER TEST) 
*         SUCH THAT A WAIT-NOT-BUSY IS PERFORMED AFTER EACH 
*         REVERSE READ. THIS PREVENTS A REPITITION RATE FAILURE 
*         MODE FROM OCCURRING. DPSR 040110. 
* 
* 
* FMD       HNS 81/01/08
* 
*         FMD46 FAILS ON TRACK FLAW. (MFG)
*         DPSR 037939 
* 
* 
* HISTORY  LJC    81/02/05
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL125PL.
* 
* 
* ELR035614      RBD  03/04/80
*         THIS MODSET ADDS THE DIAGNOSTIC ELR TO
*         THE CML LIBRARY.
* 
* 
* SKED35803      RBD  03/04/81
*         THIS MODSET ADDS THE DECK SKEDULR TO THE
*         CML LIBRARY.
* 
* 
* MALET   GLG    80/09/19.
*         MODSET ADDS LCN SUPPORT TO MALET. 
* 
* 
* MALET2E GLG    80/09/19.
*         MODSET ADDS COMMON DECK MALET2E TO CML 3.1 FOR
*         LCN SUPPORT.
* 
* 
* MALETPE GLG    80/10/31.
*         MODSET CORRECTS THE LCN COMPILER TO NOT ALLOW THE 
*         PATH NAME TO BE GREATER THAN 2 CHARACTERS.
* 
* 
* MALETPE GLG    80/10/31.
*         MODSET CORRECTS THE LCN COMPILER AUTODMP AND MEMORY 
*         COMMANDS TO ALLOW SB TO BE USED WITHIN FOR R/S. 
*         MODSET ALSO CORRECTS THE ERROR PRODUCED IF A BAD SUBSCRIPT
*         IS USED FROM SYNTAX ERROR TO BUFFER SUBSCRIPT ILLEGAL.
* 
* 
* MALET   GLG    80/10/31.
*         MODSET CORRECTS THE CVTHXB SUBROUTINE TO PRODUCE
*         AN ERROR IF ONLY THE POST SUBSCRIPT IS PRESENT. 
* 
* 
* MALET10 GLG    80/10/31.
*         MODSET CORRECTS MALET TO PRODUCE A CVT ERROR WHEN 
*         USING A POST RADIX OF H FOR LL OR TL. 
* 
* 
* MALET10 GLG    80/11/05.
*         MODSET CORRECTS MALET10 TO PRODUCE A PARAMETER ERROR WHEN 
*         ENTERING CLRDS,NN*MM OR SETDS,NN*MM.
* 
* 
* MALET   GLG    80/11/24.
*         MODSET CORRECTS THE DEVICE CODE FIELD ON MALET ASSIGN 
*         MESSAGE FOR UP TO FOUR DIGITS.
* 
* 
* DTC       HNS 81/01/26
* 
*         DTC04 MISLEADING ERROR REPORTING. 
*         DPSR 013618 
* 
* 
* D88       HNS 80/10/16
* 
*         D8846 - JUMP TO INCORRECT STATEMENT NUMBER. 
*         DPSR 037711 
* 
* 
* HPA36   SLS  81/02/05 
* 
*        CORRECTS UPDATE DIRECTIVE ERROR CREATED BY HPA019278.
* 
* 
* FMU     JMO    81/01/26 
*         MODSET CORRECTS FMU SO THAT A MESSAGE WILL BE 
*         DISPLAYED WHEN A PAUSE OCCURS IN VARIOUS MODULES. 
*         DPSR 027165.
* 
* 
* INSTLDKS JMO    81/02/17
*          MODSET ADDS INSTALLS FOR NOS6 AND NOSBE6. DPSR 037937. 
* 
* 
* MALET30 JMO    81/02/17 
*         MODSET ADDS THE SETFS MACRO SO MALET WILL ASSEMBLE
*         ON NOS R6. DPSR 037937. 
* 
* 
* ASSYTAG JMO    81/02/16 
*         MODSET ADDS NOS6, NOS7 AND NOSBE6, NOSBE7 DEFINITIONS 
*         TO ASSYTAG. DPSR 037937.
* 
* 
*    HPA3   SLS  81/01/20 
*    HPA7 
* 
*          CORRECTS CYBERAMA TRANSMIT PROBLEMS INCLUDING -
*            - MESSAGES INDICATING MISSING DATA 
*            - MISSING ITEMS IN THE HARDWARE CONFIGURATION LISTING
*            - INCORRECT EVENT AND LOST TIMES 
*            - DUPLICATE TRANSMIT RECORDS WITH ZERO COUNTS
* 
* FMC     JMO    81/02/09 
*         MODSET CORRECTS THE DOCUMENTATION BY INSERTING IF 
*         DEFINES SO THE PARITY SENTENCES ARE ONLY LISTED IF
*         CMSE IS DEFINED. DPSR 035972. 
* 
* 
* DTC       HNS 80/11/12
* 
*         DTC17 - GETS LOST CONTROLWORD IN CONTROL SEQUENCE.
*         1. DISPLAY CHANNEL STATUS ON ERR(DTC17/18/19) 
*         2. CORRECT CONTROL WORD SEQUENCE IN DTC17.
*         DPSR 037702 
* 
* 
* DTC       HNS 81/02/13
* 
*         DTC MESSAGE XXXXB FLAWED SECTORS FOUND. 
*         DPSR 038275 
* 
* 
* DTC       HNS 81/02/13
* 
*         DTC ERROR REPORTING.
*         DPSR 038277 
* 
* 
* MALETP8 KM     80/10/10 
*         MODSET MODIFIES THE MALETP8 COMPILER TO 
*         SUPPORT THE FEDERAL STANDARD CHANNEL. 
* 
* MALET   KM     80/10/03 
*         ADDS NEW DEVICE CODES TO MALET
* 
* MALET10 KM      80/10/2 
*         MODSET ADDS DEVICE CODES TO THE 
*         DEVICE DISPLAY DATA.
* 
* MALETPE GLG    81/01/18.
*         MODSET CORRECTS THE FOLLOWING PROBLEMS WITHIN THE LCN 
*         LCN COMPILER, 
*           1. PROPER ENTRY POINT FOR SEND COMMAND. 
*           2. WRITE DOES NOT STORE WORD COUNT FOR WRITE CODE.
*           3. READ DOES NOT STORE WORD COUNT FOR READ CODE.
*           4. ASCII FOR 0-9 GENERATED AS 160-171 SHOULD BE 60-71.
*           5. EXTRA CODE GENERATED BY INQUIRE COMMAND. 
*           6. FIELD LENGTH .GT. 20K OCTAL WORDS DUE TO LCN COMPILER. 
*           7. THE SELECT INPUT COMMAND NEEDS TO BE DELETED.
* 
* 
* HISTORY  RBD    81/03/06
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL126PL.
* 
*          PWL  81/02/23
* HPA1,2   MODSET HPA035992 CORRECTS DETAIL, DETAIL EXTENTED AND
* HPA37    ANALYSIS REPORTS FOR MSS ERROR MESSAGES, MODIFIES STA- 
* HPA8,9   TISTIC DETAIL REPORT FOR USAGE AND GENERATES MSS MEDIA 
*          REPORT.
* 
*  HPA    RAS  81/02/20 
*         MODSET HPA035406 ALLOWS THE DETAIL STATUS ANALYSIS FEATURE
*         TO BE OPTIONALLY ASSEMBLED IN HPA.  THE FEATURE IS ENABLED
*         THROUGH INCLUSION OF A "*DEFINE,XXX" DIRECTIVE DURING THE 
*         INSTALL PROCESS, WHERE XXX INDICATES THE PRODUCT TO BE
*         SUPPORTED.
* 
* 
*  HPA    RAS  81/02/23 
*         MODSET HPA035408 ADDS THE 66X DETAIL STATUS ANALYSIS FEATURE
*         TO HPA.  THIS FEATURE CAN BE IMPLEMENTED BY INCLUDING A 
*         "*DEFINE,66X" UPDATE DIRECTIVE IN THE INPUT STREAM DURING THE 
*         INSTALL PROCESS.
* 
* 
*  HPA    RAS  81/02/24 
*         MODSET HPA035411 ADDS THE 885 DETAIL STATUS ANALYSIS FEATURE
*         TO HPA.  THIS FEATURE IS ENABLED THROUGH INCLUSION OF A 
*         "*DEFINE,885" UPDATE DIRECTIVE DURING HPA'S INSTALL PROCESS.
* 
* 
* D44     JES    81/01/15 
*         THIS MODSET CORRECTS D44 SUCH THAT IT RUNS ON 844 UNITS 
*         ATTACHED TO A 7155 (FMD) CONTROLLER.  MODS ARE NECESSARY
*         DUE TO DIFFERENCES IN 7154/7155 CONTROLLER DETAIL STATUS. 
*         DETAIL STATUS ANALYSIS ERROR MESSAGES ARE ALSO CHANGED TO 
*         AGREE WITH HPA DETAIL STATUS ANALYSIS MESSAGES (ERROR CODES 
*         ECXXX ARE CHANGED TO SYMPTOM CODES SCXXX BUT THE CODES AND
*         MESSAGES REMAIN THE SAME).
* 
* 
* FMC       HNS 81/03/03
* 
*         FMC RESERVES DRIVE IN CONCURRENT OPERATION.(BOEING) 
*         1. CONVERT FMC25 TO USE FMDHT.
*         2. CONVERT FMC26 TO USE FMDHT.
*         3. SPLIT FMC25 INTO FMC24 AND FMC25.
*         4. CORRECT MISC. TYPO(S) AND ADD COMMENTS AS NEEDED.
*         5. ADD DOCUMENTATION FOR FMC26. 
*         6. UPDATE DOCUMENTATION FOR FMC24 AND FMC25.
*         7. CONVERT FMC250 TO DISPLAY GENERAL AND DETAILED STATUS. 
*         8. ADD FMC24 TO DISPLAY IN FMC99B.
*         9. CORRECT FMC21/FMC22 TYPO IN FMC99B.
*         10.ADD FMC24 TO 3.3 SECTION DESCRIPTION.
*         11.ADD AL.GE.4 CHECKS TO FMC24 AND FMC25. 
*         DPSR 037101 
* 
* 
* MALET   JES    81/02/02 
*         THIS MODSET SATISFIES THE REQUESTS MADE IN DPSR-S 032618 AND
*         037152.  TO ALLOW THE USER TO DEFINE THE SIZE OF PAPER USED 
*         FOR BATCH OUTPUT AND THE NUMBER OF LINES PER INCH TO PRINT, 
*         TWO SYMBOLS CAN BE DEFINED AT MALET ASSEMBLY TIME.  A DEFINE
*         OF 8LPI FORCES EIGHT LINES PER INCH PRINTING.  IF NOT DEFINED 
*         PRINTING WILL DEFAULT TO SIX LINES PER INCH.  A DEFINE OF 
*         PAPER85 INDICATES THAT 8.5 INCH PAPER IS BEING USED.  IF NOT
*         DEFINED, 11 INCH PAPER IS ASSUMMED.  BASED ON THESE TERMS,
*         BATCH OUTPUT IS CONSTRUCTED SUCH THAT FORMATTED OUTPUT WILL 
*         NOW USE ALL BUT ONE INCH OF THE PAGE AVAILABLE. 
*         THIS MODSET ALSO ADDS AN UNFORMATTED BATCH OUTPUT OF ALL DATA 
*         PRINTED EXCEPT COMPILER INPUT (LO=I) AND COMPILER OUTPUT
*         (LO=L).  THIS ALLOWS PAPER CONSERVATION BY PRINTING OVER THE
*         FAN-FOLDS ON BATCH OUTPUT.  PAGE EJECTS AND BANNERS ARE NOT 
*         PRINTED IN THIS FORMAT TO ALLOW PLOTS AND PICTURES TO BE
*         CONTIGUOUS.  IN ADDITION, THIS MODSET ADDS THE VERSION AND
*         LEVEL NUMBER TO THE MALET BANNER (FROM COMMON DECK VERS) AND
*         SENDS A SHORT BANNER TO THE TERMINAL ONCE IF RUNNING IN 
*         TERMINAL MODE.
* 
* 
* D44     JES    81/01/12 
*         THIS MODSET ADDS MODULE 48 TO D44.  IT PROVIDES A SCAN
*         CAPABILITY SIMILAR TO FORMAT/FMT ROUTINES WHICH PRINTS
*         THE PACK SERIAL NUMBER, CONTENTS OF THE FACTORY MAP,
*         THE UTILITY MAP AND THEN SCANS THE ENTIRE DISK PACK 
*         AND REPORTS ALL ADDRESSES WHICH HAVE THE TRACK OR SECTOR
*         FLAW BITS SET.  THIS MODULE DOES NOT PROVIDE THE ABILITY
*         TO WRITE OR MODIFY THE ADDRESS FIELDS ON A DISK PACK. 
*         THIS MODSET PARTIALLY SATISFIES REQUESTS MADE IN DPSR-S 
*         012975 AND 015557.
* 
* 
* T6X     JES    80/10/31 
*         THIS MODSET ATTEMPTS TO IMPROVE THE ABILITY OF MALET T6X
*         TO DETECT ERRORS SEEN BY CEAIDS T6X.  CURRENTLY, THE I/O
*         CHANNEL IS RELEASED TO THE SYSTEM AFTER EVERY RECORD.  THIS 
*         CONCEPT IS CHANGED TO RELEASE IT ONLY IF NEEDED BY THE O/S
*         OR A DELAY BETWEEN RECORDS OF .GT. 20D MSEC IS REQUESTED BY 
*         THE USER (MAKES T6X THE SAME AS T5X AND T7X).  THIS MODSET
*         SHOULD THEREFORE INCREASE THE REPETITION RATE OF THE TEST.
*         IT IS IN RESPONSE TO DSPR NUMBER 036132.
* 
* 
* T7X     JES    81/01/26 
*         MODSET T7X040115 ADDS A GCR KILLER PATTERN TEST (T7X82) TO
*         T7X AS A REPAIR MODULE.  THE PRIMARY PURPOSE OF THIS MODULE 
*         IS TO TEST 200 IPS 6250 BPI UNITS AND THEIR SENSITIVITY TO
*         A DATA PATTERN THAT IS KNOWN TO CREATE PEAK SHIFT PROBLEMS
*         IN THESE UNITS (FCO IN PROCESS).  HOWEVER, THIS MODULE CAN
*         BE EXECUTED ON ANY 67X UNIT.  (SATISFIES DPSR 040115).
* 
* 
* FMC       HNS 81/02/03
* 
*         FMC15 ISOLATION OF A15 MISSING FROM 6901EH. 
*         DPSR 037714 
* 
* 
* FMC       HNS 81/02/02
* 
*         FMC17B - S/W ERROR (A SOFTWARE ERROR) 
*         DPSR 037716 
* 
* 
* FMC       HNS 81/01/30
* 
*         FMC04 I/0 TIME OUT ON CH RESERVE. 
*         DPSR 037712 
* 
* 
* MALET12 JMO    81/01/22 
*         MODSET CORRECTS THE EOR RECORD STATUS ON A SYSRD. 
*         DPSR 040068.
* 
* 
* INSTLDKS JMO   81/02/18 
*          MODSET ADDS HPA31 TO INSTLDKS FOR NOS4, NOS5 
*          AND NOSBE4, NOSBE5. DPSR 013092. 
* 
* 
* MALET20 JMO    81/01/16 
*         MODSET CORRECTS THE POSSIBILITY OF HANGING THE
*         SYSTEM ON A LOG COMMAND IF THE MLD CHANNEL IS 
*         THE SAME AS THE ERROR LOG. DPSR 035988. 
* 
* 
* INSTLDKS GLG    81/03/02. 
*         MODSET MODIFIES TO NOS AND NOSBE INSTLDKS FOR LCN 
*         INSTALLATION.  DECK MALET2E MUST BE COMPILED AND THE
*         FIELD LENGTH ON NOSBE INCREASED FROM 20000 TO 21000.
* 
* 
*  INSTLDKS RAS  81/02/24 
*         MODSET INS035412 INSERTS "*DEFINE" UPDATE DIRECTIVES IN HPA'S 
*         INSTALLATION INPUT.  THESE "*DEFINES" RESULT IN THE DETAIL
*         STATUS ANALYSIS FEATURES FOR 66X,67X,844, AND 885 TO BE 
*         ENABLED.  REMOVAL OF ANY OR ALL OF THE DEFINES WILL DISABLE 
*         ASSEMBLY OF THE DSA FEATURE FOR THE INDICATED PRODUCT.  THIS
*         WILL ALLOW EACH INSTALLATION TO TAILOR HPA TO THEIR SPECIFIC
*         CONFIGURATION.  THIS WILL MINIMIZE THE EXECTION FIELD 
*         LENGTH REQUIREMENTS FOR HPA.
* 
* 
* MALET   JES    81/02/03 
*         THIS MODSET CHANGES THE WAY TERMINAL OUTPUT IS HANDLED WHEN 
*         RUNNING WITH AN ALTERNATE OUTPUT FILE (L=LFN OR O=LFN).  IN 
*         THE CURRENT DESIGN, NO OUTPUT IS SENT TO THE TERMINAL UNTIL 
*         THE INPUT FILE NAME IS INPUT.  THIS MEANS NO OUTPUT TO THE
*         TERMINAL IF A PROCEDURE FILE IS INITIATED FROM THE TERMINAL.
*         THE ORIGINAL INTENT OF THE OPTIONAL OUTPUT FILE WAS TO ALLOW
*         LARGE AMOUNTS OF OUTPUT, SUCH AS COMPILER LISTINGS, TO BE 
*         SENT TO A FILE WITHOUT LOADING DOWN THE TERMINAL.  AFTER THE
*         CHANGES ARE MADE, THIS IS STILL POSSIBLE IF THE INPUT FILE
*         NAME IS  COMPILE  .  ANY OTHER FILE NAME FOR INPUT WILL CAUSE 
*         DUPLICATE OUTPUT ON THE ALTERNATE OUTPUT FILE AND TERMINAL. 
*         THIS MODSET IS IN RESPONSE TO DPSR 015793.
* 
* 
* INSTLDK JES    81/02/24 
*         MODSET INS032618 MODIFIES THE INSTALL DECKS FOR MALET SUCH
*         THAT *DEFINE CARDS IDENTIFY THE LINES-PER-INCH PRINTING TO
*         BE USED AND THE SIZE PAPER TO BE USED.  IF 8LPI IS DEFINED, 
*         PRINTING IS PERFORMED AT 8 LINES-PER-INCH, IF NOT, AT 6 LINES 
*         PER INCH.  IF PAPER85 IS DEFINED, 8.5 INCH PAPER IS ASSUMMED, 
*         IF NOT DEFINED, 11 INCH PAPER IS ASSUMMED.
* 
* 
* D44     JES    81/01/12 
*         THIS MODSET MODIFIES MODULE D4406 (READ PRE-RECORDED CYL) 
*         SUCH THAT IT READS THE CYLINDER AT ALL COMBINATIONS OF
*         STROBES AND OFFSETS.  THIS PROVIDES A BETTER TEST FOR HEAD
*         ALIGNMENT THAN IS CURRENTLY PROVIDED.  IF AN ERROR OCCURS,
*         LINE 1 OF THE ERROR OUTPUT IDENTIFIES THE MARGINS CURRENTLY 
*         IN EFFECT.  (SATISFIES REQUESTS IN DPSR NUMBER 009296). 
*         THIS MODSET ALSO MODIFIES MODULE D4413 (MARGINS) TO REPORT
*         THE CURRENTLY SELECTED MARGINS ON LINE 1 IF AN ERROR OCCURS 
*         RATHER THAN REQUIRING THE CE TO DECODE THE CONTENTS OF B2.
* 
* 
* D44     JES    81/01/15 
*         THIS MODSET IMPROVES THE RUNNING MESSAGE PRINTED TO THE 
*         REMOTE USER FOR MODULE 46.  IT PARTIALLY SATISFIES
*         DPSR NUMBER 014268 (THE REMAINING ITEMS REQUESTED IN
*         THIS DPSR HAVE ALREADY BEEN ACCOMPLISHED WITH MODSET
*         D44015304). 
* 
* 
* T6X     JES    81/01/20 
*         THIS MODSET SATISFIES THE REQUEST MADE IN DPSR 040112 BY
*         ADDING DETAIL STATUS ANALYSIS CAPABILITY TO T6X.  DDLT AND
*         CONTROLWARE ERROR CODES SIMILAR TO THOSE POSTED BY T7X ARE
*         NOW REPORTED BY T6X.  EXTERNAL DOCUMENTATION IS ADDED THAT
*         DEFINES ALL THE NEW MESSAGES ADDED. 
* 
* 
* T6X     JES    80/12/09 
* 
*         THIS MODSET MODIFIES T6X MODULES 02,03,13,18 AND 20 TO
*         ALWAYS CREATE THE DATA IN THE OUTPUT BUFFER WHEN DATA 
*         COMPARE IS ENABLED.  THIS ALLOWS THE OUTPUT BUFFER TO BE
*         USED AS THE SLUSH BUFFER ON READ OPERATIONS, MAKING THE 
*         LAST 500B WORDS READ FROM A RECORD AVAILABLE TO THE USER. 
*         IT SATISFIES THE REQUEST MADE IN DPSR 040113 (NOTE- 
*         TO BE EFFECTIVE, THE MLD 66X PRODUCT OVERLAY MUST ALSO
*         HAVE MODSET MLD040113 INSTALLED). 
* 
* 
* HPA     SLS  81/03/12 
* HPA3
* HPA38 
* 
* 
*        ADDS A170 SECDED PHASE II TO HPA.
* 
*  HPA    RAS  81/02/23 
*         MODSET HPA035407 ADDS THE 67X DETAIL STATUS ANALYSIS FEATURE
*         TO HPA.  THIS FEATURE CAN BE IMPLEMENTED BY INCLUDING A 
*         "*DEFINE,67X" UPDATE DIRECTIVE IN THE INPUT STREAM DURING THE 
*         INSTALL PROCESS.
* 
* 
* DTC       HNS 81/03/09
* 
*         DTC DOES NOT STOP ON ERROR. 
*         DPSR 038274 
* 
* 
* ASSYTAG JMO    81/03/11 
*         MODSET ADDS DEFINES OF NOS5, NOS6 AND NOSBE5, NOSBE6
*         TO DEFINES OF NOS4, NOS5 AND NOSBE4, NOSBE5 SO MALET
*         WILL ASSEMBLE WITHOUT ERRORS. DPSR 035826.
* 
* 
* MLTDOC  JES    81/01/30 
*         THIS MODSET, IN CONJUNCITON WITH MAL037703, MAKES IT POSSIBLE 
*         TO USE A BLANK LINE TO SEPERATE EXTERNAL DOCUMENTATION FROM 
*         INTERNAL DOCUMENTATION WITHOUT USING UP ONE OF THE 120 LINES
*         OF SOURCE CODE.  A BLANK LINE IMMEDIATELY FOLLOWING AN *
*         COMMENT CARD IS CONSIDERED A LINE OF DOCUMENTATION, NOT A 
*         LINE OF SOURCE CODE.  ANY BLANK LINE NOT PRECEEDED BY AN *
*         COMMENT CARD IS STILL CONSIDERED A LINE OF SOURCE CODE.  THIS 
*         MODSET IS IN RESPONSE TO DPSR 037703. 
* 
* 
* MALET   JES    81/01/30 
*         THIS MODSET, IN CONJUNCTION WITH MLT037703, MAKES IT POSSIBLE 
*         TO USE A BLANK LINE TO SEPERATE EXTERNAL DOCUMENTATION FROM 
*         INTERNAL DOCUMENTATION WITHOUT USING UP ONE OF THE 120 LINES
*         OF SOURCE CODE.  A BLANK LINE IMMEDIATELY FOLLOWING AN *
*         COMMENT CARD IS CONSIDERED A LINE OF DOCUMENTATION, NOT A 
*         LINE OF SOURCE CODE.  ANY BLANK LINE NOT PRECEEDED BY AN *
*         COMMENT CARD IS STILL CONSIDERED A LINE OF SOURCE CODE.  THIS 
*         MODSET IS IN RESPONSE TO DPSR 037703. 
* 
* 
* MALET   JES    81/01/21 
*         THIS MODSET SATISFIES THE REQUEST MADE IN DPSR 036989.  IF
*         THE LINE LIMIT ON OUTPUT IS EXCEEDED WHILE RUNNING IN BATCH 
*         MODE (NOT TERMINAL, NOT KL FLAG ON), A MESSAGE IS ISSUED TO 
*         THE DISPLAY AND DAYFILE AND MALET TERMINATES.  THIS PREVENTS
*         MALET REMAINING AT A CONTROL POINT UNTIL THE OPERATOR DECIDES 
*         TO DROP IT OR GIVE IT A GO. 
* 
* 
*  HPA    RAS  81/02/23 
*         MODSET HPA035409 CORRECTS A PROBLEM WHERE THE DETAIL STATUS 
*         ANALYSIS TABLE SEARCH WILL TERMINATE PREMATURELY SHOULD THE 
*         120 BIT MASK, WHEN "OR"ED TOGETHER, RESULT IN NEGATIVE
*         ZERO (X0=77....77). 
* 
* 
* HPA     RTG   81/03/11
*         THIS MODSET ADDS THE MAINFRAME IDENTIFIER (MFID) TO THE 
*         UNIT ANALYSIS AND DETAIL REPORTS.  IT ALSO PROVIDES FOR 
*         MULTI-MAINFRAME SUPPORT BY ALLOWING A HARDWARE UNIQUE 
*         IDENTIFIER (HUID) TO BE USED IN PLACE OF THE EST IN ALL 
*         APPLICABLE REPORTS AS WELL AS IN THE HISTORY FILE.
* 
* HPERS   SLS  81/03/09 
* HPA 
* HPA3
* HPA36 
* 
* 
*        ADDS SECDED PHASE II TO HPA. 
* 
* TFL     TEB  81/02/16 
*         THIS MODSET ADDS K DISPLAY OF DATA COMPARE ERRORS.
* 
* 
*         DPSR HPA035827
* HPA     REF  03/11/81 
*         MODSET CONVERTS HPA FILE HANDLING FROM FORTRAN UNFORMATTED IO 
*         STATEMENTS AND FILE MANIPULATION STATEMENTS TO CENTRALIZED IO 
*         ROUTINES WHICH UTILIZE RECORD MANAGER INTERFACE (RMI).  THESE 
*         ROUTINES HAVE BEEN INSERTED ALPHABETICALLY IN HPA ZERO OVERLAY
*         PREFIXED BY "RM".  THEY REPLACE IN-LINE IO STATEMENTS AND 
*         CALLS TO SUBROUTINE GETREC, AN EARLIER EFFORT AT CENTRALIZED
*         IO HANDLING WITH FORTRAN STATEMENTS WHICH WENT UNENFORCED.
*         CIO PROVIDES THE USER WITH GREATER FILE HANDLING CAPABILITY 
*         (IE: VARIABLE LENGTH RECORDS) AND WITH DIRECT RESPONSIBILITY
*         FOR AND COMMUMICATION WITH THE SYSTEM FILE INFORMATION TABLE
*         (FIT) OF EACH FILE.  CIO ALSO PROVIDES TIGHTER PROGRAM CON- 
*         TROL.  THREE FILES REMAIN UNDER FORTRAN CONTROL, UNTOUCHED
*         BY CIO: INPUT, OUTPUT AND PUNCH.  INCLUDED IN CIO IS REMOVAL
*         OF HPA PRIMARY OVERLAY 6 (CAMS), WHICH IS NO LONGER SUPPORTED,
*         AND GENERAL HOUSE-CLEANING OF THE CODE AND LOGIC. 
* 
*         CIO ROUTINES ARE AS FOLLOWS:  
*         RMBCKSP - SPACES BACK OVER A FILE MARK
*         RMCLOSE - COMPLETES FILE PROCESSING AT END OF HPA 
*         RMFILEM - WRITES A FILE MARK
*         RMOPEN  - BUILDS FITS AND INITIALIZES FILES AT ONSET OF HPA 
*         RMREAD  - READS A RECORD
*         RMREWND - REWINDS A FILE
*         RMSKIP  - SKIPS A FILE
*         RMWRITE - WRITES A RECORD 
* 
* 
* TFL     TEB 81/02/13
*         THIS MODSET CORRECTS COMMENTS RELATIVE TO RECORDS.
*         THE WORD RECORD HAS BEEN CHANGED TO BLOCK TO BE 
*         CONSISTENT WITH THE PHYSICAL STRUCTURE OF THE TEST
*         BEING LOADED.  THIS MODSET ALSO CORRECTS COMMENTS 
*         RELATIVE TO EOR HANDLING. 
* 
* 
* TFL     TEB  81/02/13 
*         THIS MODSET FIXES OVERPRINT AT LINE 65 OF TFL99.
* 
* 
* MALETPE GLG    81/03/17.
*         MODSET DELETES HISTORY COMMENTS ADDED INTO YANK DECK. 
* 
* 
* MALETPE GLG    81/01/19.
*         MODSET ADDS NEW FORMAT FOR RES TO THE LCN COMPILER. 
* 
* 
* HPA     DDN    81/01/16 
*         MODSET WILL ALLOW UNITS TO BE SELECTABLE FOR
*         SPECIFIED HPA PARAMETERS ON MULTISPINDLE
*         DEVICES.  FOR EXAMPLE D=DTEEEUU.
*         DPSR 32619
* 
* 
* MALET10 JMO    81/03/16 
*         MODSET CORRECTS MALET SO TWO DEVICES CAN BE 
*         ASSIGNED CORRECTLY FOR MSS. DPSR 035831.
* 
* 
* MALET11 JMO    81/03/16 
*         MODSET CORRECTS MALET SO TWO DEVICES CAN BE 
*         ASSIGNED CORRECTLY FOR MSS. DPSR 035831.
* 
* 
* MALET   JES    81/01/29 
*         THIS MODSET ADDS AN AUTO EXECUTIVE DIRECTIVE TO MALET TO
*         SATISFY THE REQUESTS MADE IN DPSR 040053 AND 037139.  A 
*         STOP DIRECTIVE FROM THE KL DISPLAY CURRENTLY STOPS THE MLD
*         DRIVER, BUT DOES NOT SUSPEND READING THE INPUT FILE.  THIS
*         MAKES SHARING OF INPUT FILE AND KL DIRECTIVES IMPOSSIBLE. 
*         WITH THIS MODSET, A STOP DIRECTIVE, LEGAL ONLY FROM THE KL
*         DISPLAY WHEN NOT IN TERMINAL MODE AND THE PPU RUNNING, WILL 
*         SUSPEND READING THE INPUT FILE TO ALLOW CONTROL TO BE ASSUMED 
*         AT THE KL DISPLAY UNTIL A GO OR AUTO DIRECTIVE IS EXECUTED. 
*         READING OF INPUT WILL THEN RESUME.
* 
* 
* TFL     TEB  81/03/04 
*         THIS MODSET DOCUMENTS THE CHANGE IN ODS 2.0 
*         BINARY FILES TO DPSR LEVEL 114. 
* 
*         THE NEW BINARY FOR
*         THE ODS DIAGNOSTIC, MPRTC, REQUIRES THAT THE
*         1700 TRANSFORM BE ONE OF THE FOLLOWING- 
*         96752129, 96735700, 96752601, 96752604, 96837727, OR
*         96720404(LATEST VERSION). 
* 
* 
*  HPA3    RAS  81/02/27
*          MODSET HPA035416 COMBINES ALL DISK PACK S/N MESSAGES ON ONE
*          LINE IN THE UNIT ANALYSIS REPORTS.  THIS PREVENTS ALL
*          AVALIABLE MESSAGE SLOTS FROM BEING CONSUMED BY PACK S/N
*          MESSAGES, THUS REDUCING THE LIKELYHOOD OF TABLE OVERFLOW.
* 
* 
*  HPA    RAS  81/02/23 
*         MODSET HPA035410 MAKES MISCELLANEOUS CORRECTIONS TO THE DETAIL
*         STATUS ANALYSIS PROCESS.
* 
* 
* T7X     JES    81/01/26 
*         MODSET T7X040114 ADDS MODULE T7X36, TAPE TRACKING, TO THE 
*         STANDARD DIAGNOSTIC PASS OF T7X.  THIS MODULE SUPPORT FCO 
*         CA40786 (SINGLE FRAME SKEW) AND DPSR NUMBER 040114. 
* 
* 
* MALET   JES    81/01/28 
*         THIS MODSET ALLOWS THE RUNNING OF NON-I/O MODULES WITHOUT 
*         REQUIRING A DUMMY DEVICE TO BE ASSIGNED.  TO ACCOMPLISH 
*         THIS, THE USER MUST WRITE MODULES IN THE LOW LEVEL LANGUAGE 
*         (3000, 6000 OR BC ON MODULE CARD WITH DUMMY DEVICE CODE)
*         AND PERFORM A -RUN- DIRECTIVE WITHOUT ASSIGNING A DEVICE
*         (NO -ASSIGN- DIRECTIVE).  THIS CAPABILITY ALLOWS THE USER 
*         TO EXPERIMENT WITH THE MALET NON-I/O LANGUAGE COMMANDS IN 
*         A TRAINING ENVIRONMENT WITHOUT THE NEED TO ASSIGN A DUMMY 
*         DEVICE TO EXECUTE THE MODULES.  HOWEVER, THE SYSTEM MUST
*         STILL BE IN ENGINEERING MODE TO EXECUTE MODULES.  THIS MODSET 
*         IS IN RESPONSE TO DPSR 015559.
* 
* 
* HPA   SLS  81/03/09 
* 
* 
*        CORRECTS PROBLEM OF ACCIDENTALLY TURNING ON HPSORT IN
*        RELEASE - 125. 
* 
* HPA1    DDN    81/04/01 
*         MODSET HPA035844 CORRECTS A PROBLEM WITH MODSET HPA032619 
*         THAT WONT ALLOW ALL  DATA FOR SOME HPA PARAMATERS TO BE 
*         ENABLED.
*         DPSR HPA035844. 
* 
* 
*          PWL  81/04/01
* HPA3     MODSET HPA035836 ADDS "DATE" TO ANALYSIS REPORT
*          SUB-HEADER, PRINTS SECTION DIVIDERS. 
* 
* 
* HPA38    PWL  81/04/03
*          MODSET HPA035848 CORRECTS THE CHECKING OF
*          CONTINUE RECORDS FOR A170 REPORTS. 
* 
* 
* MALET   JES    81/04/07 
*         THIS MODSET CORRECTS A PROBLEM INTRODUCED BY MODSET MAL040053 
*         WHICH SUSPENDS READING INPUT WHEN IN TERMINAL MODE WHEN TIME
*         LIMIT IS REACHED.  MALET DOES NOT READ THE USER GO FROM THE 
*         TERMINAL. 
* 
* 
*         DPSR 035835 
* HPA     REF  03/24/81 
*         MODSET ENABLES THE READING OF A MULTI-FILE SEF BY HPA.
*         MODIFICATIONS ARE MADE TO THE OWNCODE EXIT 1 ROUTINE FOR
*         THE FIRST SORT (SEF TO LFN FSORT), WHEREBY THE SEF FILE IS
*         PROCESSED DIRECTLY, WITH CALLS TO CENTRALIZED INPUT/OUTPUT
*         (CIO) ROUTINES AND RECORD MANAGER INTERFACE (RMI) ROUTINES. 
*         EACH RECORD TO BE SORTED IS PASSED TO SORT IN ARRAY OUT(8)
*         IN THE SORT RETURN (SMRTN), AFTER BEING READ AND MASSAGED IN
*         OWNCODE EXIT 1 (SUBROUTINE ERRSET2).  A MULTI-FILE SEF IS 
*         HANDLED BY CLOSING AND RE-OPENING THE SEF FIT WHEN AN END-OF- 
*         PARTITION IS DETECTED, AS SEQUENTIAL FILES CANNOT BE POSITIONED 
*         BEYOND END-OF-INFORMATION (EOI).  NOTE THAT THE SMFILE STATE- 
*         MENT FOR THE FIRST SORT HAS BEEN DELETED IN ORDER TO PROCESS
*         THE SEF FILE DIRECTLY AND THE PARAMETERS HAVE LIKEWISE BEEN 
*         REMOVED FROM THE OWNCODE EXIT 1 SUBROUTINE ERRSET2.  MULTI-FILE 
*         SEFS MAY BE GENERATED BY SYSTEM COMMANDS COPYBR OR COPYBF.
* 
*         MODIFICATIONS HAVE ALSO BEEN MADE TO ENABLE THE READING OF A
*         MULTI-FILE SEF WHEN RUNNING HPA WITHOUT THE SORT/MERGE PACKAGE. 
*         HPA PROCESSES DATA WITH ITS OWN SORT ROUTINES IN OVERLAY 2
*         WHEN HPSORT HAS BEEN DEFINED IN THE UPDATE RUN (IE: *DEFINE 
*         HPSORT).  THESE CHANGES EXIST IN SUBROUTINE SALOAD2.
* 
* 
* HPA2    SLS  81/04/07 
* 
* 
*         MODSET HPA035850 CORRECTS THE PROBLEM OF HPSORT PRODUCING 
*         AN EXTRA RECORD OF ALL ZEROS. 
* 
* MALET   JES    81/04/02 
*         THIS MODSET CORRECTS A PROBLEM CREATED BY MODSET MAL032618. 
*         CURRENTLY, THERE IS NO PAGE EJECT PERFORMED WHEN PRINTING 
*         THE CROSS-REFERENCE TABLE FOR A MODULE AND PRINTING OCCURS
*         ACROSS THE PAPER FAN-FOLD.  THE MODLE CROSS-REFERENCE MAP 
*         IS CORRECTED TO USE FORMATTED PRINTING (PAGE EJECT/BANNER). 
* 
* 
* HISTORY  NDP    81/04/24
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL126RD.
* 
* 
*          PWL  81/03/19
* HPA5     MODSET HPA013090 CORRECTS WRONG DATES IN THE 
*          "DATE OCCURRED" SECTION OF THE SUMMARY REPORT, 
*          IF THE HISTORY FILE EXTENDS OVER THE YEAR END. 
* 
* 
* TFL     CL     81/03/13 
*         THIS MODSET ENABLES COMPILING SOURCE OF TFL99 MODULE. 
*         DPSR 030150.
* 
* 
* MALET10 JMO    81/03/31 
*         MODSET CORRECTS THE DISPLAY DIRECTIVE OF MALET
*         TO INCLUDE THE LIST AND SEND DIRECTIVES. DPSR 
*         023962. 
* 
* 
* HPA     DDN    81/03/04 
*         MODSET WILL INSERT 2 ** INTO THE LINES ON THE 
*         DETAIL REPORT WHERE THE CYLINDER,TRACK, OR
*         SECTOR INFORMATION ARE NOT IN AGREEMENT WITH
*         THE DETAILED STATUS. ALSO INSERT AN APPROPIATE
*         COMMENT AT THE END OF THE DETAIL REPORT.  THIS
*         MODSET APPLIES TO 844 AND FMD REPORTS ONLY. 
*         DPSR 033089 
* 
* 
*          PWL  81/03/31
* HPA7     MODSET CORRECTS THE REPORTING OF MTBI WHEN THERE IS
*          NO UNSCHEDULEDED DEGRADED EVENTS INTERRUPTIONS OR
*          UNSCHEDULED DOWN EVENTS INTERRUPTIONS. A DASH IS 
*          PRINTED INSTEAD OF ZEROES. 
* 
* 
* LP1     JMO    81/03/31 
*         MODSET CORRECTS MODULES 4 AND 5 TO PRINT A FULL 
*         LINE FOR A TYPE 6 TRAIN. DPSR 038213. 
* 
* 
* DTC       HNS 81/03/18
* 
*         DTC98A/98B DONT CHECK CYLINDER BOUNDARIES.(SERI)
*         DPSR 039402 
* 
* 
* DTC       HNS 81/03/18
* 
*         DTC FALSE ERROR IN MODULE DTC02.(SERI)
*         1. REMOVE REFERENCE TO DTC02B FROM DTC02 DOCUMENTATION. 
*         2. CHANGE RES ABORT TO PREVENT EXECUTION OF RTZ AT 60.
*         DPSR 039408 
* 
* 
*          PWL  81/03/23
* HPA1     MODSET HPA039407 CORRECTS PROBLEM WITH HW PARAMETER
*          WHEN THE HISTORY FILE EXTENDS OVER THE YEAR END. 
* 
* 
* TFF     JMO    81/04/01 
*         MODSET CORRECTS TFF SO THE EXTERNAL DOCUMENTATION 
*         WILL CONTAIN THE NECESSARY DOCUMENTATION TO EXECUTE 
*         THE TEST. DPSR 039603.
* 
* 
* DTC       HNS 81/03/20
* 
*         DTC IN CONCURRENT ENVIRONMENT.(SERI)
*         1. ADD ENABLE FULL SEEKS PARAM TO DTC98A/B. 
*         2. ADD P4 DOCUMENTATION TO DTC99A.
*         3. ADD P4 TO 3.2 PARAMETERS.
*         4. MOVE RES(S) IN DTC06/07/10 TO AVOID I/O TIMEOUT ERRORS.
*         5. CORRECT PARAMETER USAGE BUG IN DTC10.
*         DPSR 040078 
* 
* 
* HPERS    TEF  81/03/27
*          MODSET HPA013091 ADDS DOCUMENTATION FOR DSA PARAMETER. 
* 
* 
* DTC       HNS 81/03/24
* 
*         DTC05 GIVES ERRONEOUS MESSAGE 
*         DPSR 035984 
* 
* 
* HISTORY  NDP    81/04/24
*         THIS MODSET UPDATES THE BUILD 
*         IDENTIFIER FOR THIS BUILD TO
*         CL127PL.
* 
* 
* D88     JMO    81/01/30 
*         MODSET MODIFIES D88 TO ALLOW IT TO BE RELEASED
*         AS A NON-TSP DIAGNOSTIC. FEATURE DPSR 035893. 
* 
* 
* FMC     JMO    80/01/20 
*         MODSET INSTALLS UPDATE DEFINES INTO THE PL SO AS
*         TO ALLOW FMC TO BE ASSEMBLED WITHOUT TSP DEFINED. 
*         FEATURE DPSR 035893.
* 
* 
* FMD     JMO    80/01/20 
*         MODSET INSTALLS UPDATE DEFINES INTO THE PL SO AS
*         TO ALLOW FMD TO BE ASSEMBLED WITHOUT TSP DEFINED. 
*         FEATURE DPSR 035893.
* 
* 
* FMC       HNS 81/04/10
* 
*         FMC03 SELECTS 844 DRIVE UNIT 0. 
*         DPSR 037733 
* 
* 
* FMC       HNS 81/04/15
* 
*         FMC01 DOESNT WORK FOR UPPER BIT ERROR.
*         DPSR 027174 
* 
* 
* FMC       HNS 81/04/10
* 
*         FMC GETTING INVALID ERROR STOPS.
*         DPSR 011570 
* 
* 
* LP1     JMO    81/04/07 
*         MODSET CORRECTS THE I/O TIMEOUT THAT COULD OCCUR
*         IN LP1 MODULES 02,03,34,35 AND 38 IF THE PRINTER
*         WAS HUNG BUSY. DPSR 038217. 
* 
* 
* LP1     JMO    81/04/03 
*         MODSET CORRECTS THE IMAGE FOR A 595-6 TYPE TRAIN
*         IN LP1. DPSR 038215.
* 
* 
* TFF     JMO    81/04/08 
*         MODSET CORRECTS TFF02 TO ELIMINATE FALSE ERRORS 
*         OF PICKING BIT 11 ON TRYING TO RUN TFF AFTER
*         POWER UP OR RECABLING. DPSR 009238. 
* 
* 
* HPA35    PWL  81/04/09
*          MODSET HPA035983 RE-INITIALIZE ARRAY "NPORT" AFTER 
*          THE PROCESSING OF DATA FOR PORTS ACTIVE VS. HOUR 
*          OF DAY GRAPH.
* 
* 
* FMD     JMO    81/04/09 
*         MODSET CORRECTS FMD34 SO EXTERNAL DOCUMENTATION LINES 
*         ARE NOT ASSEMBLED AS SOURCE CODE. DPSR 035853.
* 
* 
* INSTLDKS TEF  81/04/15
*          MODSET INS035854 DELETES ALL *COMPILE,HPA6 CARDS FROM ALL
*          INSTALL DECKS AND ADDS *COMPILE,HPA39 FOR LCN
* 
* 
*         DPSR 033405 
* HPA     REF  04/20/81 
*         MODSET CREATES LCN SUB 3 OVERLAY (3,9) AND GENERATES
*         REPORTS FROM THE BINARY MAINT LOG LCN DATA WHICH WAS
*         CONVERTED TO SEF FORMAT IN NORM.  THE REPORTS ARE:  
*         1) LCN STATISTICS AND 2) LCN STATISTICS SUMMARY.  BOTH
*         PRESENT DATA FROM LCN RECORD TYPE 74B, WHICH CONSISTS 
*         OF TWO CONTIGUOUS SEF RECORDS CONTAINING DETAILED 
*         STATUS/USAGE DATA.  IN ADDITION TO USING HPA MECHANISMS 
*         FOR PROCESSING AND UNPACKING THE LCN SEF RECORDS,  LCN
*         DATA IS MASSAGED IN A SORT OWNCODE ROUTINE TO ACHIEVE 
*         ORDERING BASED ON HUI RATHER THAN EST FOR RT 74B AND ON 
*         RECORD TYPE RATHER THAN HUI/EST FOR RTS 75B/76B.
* 
* 
*         DPSR O33431 
*  HPA    REF 04/24/81
*         MODSET AMENDS THE MULTI-FILE SEF CAPABILITY, BY 
*         CORRECTLY PROCESSING THE LAST RECORD WHEN IT IS 
*         TO BE BYPASSED. 
* 
* 
* MALET   JES    81/04/24 
*         THIS MODSET CORRECTS A BUG IN THE MALET COMPILER FOR THE
*         COMPARE COMMAND (COMPARE W TO X FOR Y, ABT Z).  CURRENTLY,
*         THE COMPILER INCORRECTLY ALLOWS Y TO BE ANY REGISTER, NOT 
*         JUST B0-B15, WC AND BA AS DOCUMENTED.  CODE ADDED IN CML 3.1
*         WHICH MOVED THE PARAMETER REGISTERS P0-P9 TO MEMORY CELLS 
*         NOW MEANS BAD CODE IS GENERATED IF P0-P9 IS USED AS VALUE Y.
*         THIS BAD CODE CRASHES THE OPERATING SYSTEM. 
*         THIS MOD IS IN RESPONSE TO DPSR 033420. 
* 
* 
* HISTORY AKJ   81/05/13
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO CL128PL.
* 
* 
* MALET11 GLG    81/05/05.
*         MODSET ADDS CHECK FOR CONVERSION ERROR WHEN PROCESSING
*         ACCESS CODE FIELD ON ASSIGN DIRECTIVE.
* 
* 
* MALET20 JMO    81/04/14 
*         MODSET CORRECTS THE PROBLEM OF THE WRONG CODE 
*         BEING GENERATED FOR AN LCN INSTRUCTION FOR THE
*         LOG COMMAND INTRODUCED BY MODSET MAL035988. 
*         DPSR 035861.
* 
* 
* HPA1    SLS  81/04/13 
* HPA7
* 
*          MODSET HPAO35860 CORRECTS THE PROBLEM OF HPA SHOULD ABORT
*          IF THE I PARAMETER IS SELECTED WITHOUT THE NH PARAMETER
*          SPECIFIED. 
* 
* 
* MALET11 GLG    81/05/12.
*         MODSET ADDS HEX ABLITY TO ASSIGN PARAMETERS IF TRAILED
*         WITH A H. 
* 
* 
* DTC       HNS 81/05/13
* 
*         DTC13-16 ABORT WITH AL TO LOW.
*         DPSR 033404 
* 
* 
* DTC       HNS 81/05/13
* 
*         DTC15 LOOPS FOREVER.
*         DPSR 033402 
* 
* 
* T7X     MSF    81/05/08 
*         MODSET DETECTS AN ILLEGAL DENSITY SELECTION WHEN GCR DENSITY
*         IS SELECTED AGAINST A 679-2 THRU -4, IN MODULE 00 OF T7X
*         ON-LINE DIAGNOSTIC. 
* 
* 
* HPA34     LWW  81/05/20 
*           THE SECOND LINE OF A TWO-LINE DETAIL EXTENDED REPORT
*           ENTRY OCCASIONALLY APPEARS ON THE NEXT PAGE UNDER A SEPARATE
*           ERROR HEADING 
* 
* 
* HPA     GLG    81/05/22.
*         MODSET REMOVES INCORRECT COPYRIGHT AND PROPRIETARY
*         NOTICES.
* 
* 
* CPYCOM   GLG    81/05/22. 
*         MODSET REMOVES INCORRECT COPYRIGHT STATEMENTS FROM CPYCOM.
* 
* 
* CPYFTN  GLG    81/05/22.
*         MODSET CHANGES THE CONTROL DATA CORPORATION COPYRIGHT 
*         STATEMENTS TO MEET THE STANDARD.
* 
* 
* HPA36    SLS  81/05/28
* 
*        MODSET HPA032408  CORRECTS THE PROBLEM WHERE THE LCME SINGLE 
*        BIT FAILING AND THE SYNDROME CODE DID NOT MATCH. 
* 
* 
* MALET10 JMO    81/05/18 
*         MODSET CORRECTS THE MALET DEVICES DISPLAY ERRORS
*         CREATED BY MODS LCNMAL AND MAL37943C. DPSR 035895 
* 
* 
* HPA7    SLS  81/05/28 
* 
*        MODSET HPA035932 CORRECTS THE PROBLEM OF HARDWARE
*        RECORDS BEING XMITTED MORE THAN ONCE.
* 
* 
* HPA2    DDN    81/05/21 
*         MODSET WILL ENSURE THAT THE DEADSTART 
*         LEVEL FOR NOSBE SYSTEMS IS REPORTED ON
*         HPA SITE MANAGEMENT REPORTS.
*         DPSR 033474.
* 
* 
* HISTORY RBD   81/06/02
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO CL129PL.
* 
* 
* 
* 
* NLM     RBD 81/07/02
*         THIS MODSET ADDS DECK NLM 
*         (LCN) TO THE LIBRARY. 
* 
* 
* LCN     RBD 81/07/02
*         THIS MODSET ADDS DECK LCN 
*         TO THE LIBRARY. 
* 
* 
* LCM     RBD  81/07/02 
*         THIS MODSET ADDS DECK LCM TO THE
*         LIBRARY.
* 
* 
* NLM     MBA    81/06/24 
*         MODSET NLM037746 CORRECTS THE HARDWARE AND
*         CONTROLWARE STATUS REPORTING, CONTROL PACKAGE 
*         REPORTING, ERROR REPORTS FOR REMOTE LOAD ERRORS 
*         AND PROCESSOR STOPS FOR NLM.  THE STATUS CRACKING 
*         MODULES IN NLM HAVE BEEN UPDATED PER A02 VERSION
*         OF CONTROLWARE. 
* 
* 
* D88     JMO    81/05/22 
*         MODSET CORRECTS D88 SO IT CAN BE ASSEMBLED WITHOUT
*         TSP DEFINED. FEATURE DPSR 033484. 
* 
* 
* CR1     MSF    81/05/22 
*         MODSET CORRECTS DATA COMPARE DISPLAYS TO SHOW 80 COLUMN 
*         BINARY AND 40 COLUMN BCD DATA AND INFORMS USER IN WHICH 
*         FORM THE CARD WAS READ. DPSR 034137.
* 
* 
* HPA7    SLS  81/05/13 
* 
*        MODSET HPA033457 CORRECTS THE PROBLEM OF OPTIME MISSING
*        MESSAGE ALWAYS BEING PRINTED WHETHER THERE IS VALID
*        DATA OR NOT. 
* 
* 
* T5X     MSF    81/05/01 
*         MODSET CORRECTS DEEP END PROBLEMS IN MODULE 60
*         OF T5X WITH C17X AND 75IPS UNITS. DPSR 024349.
* 
* 
* FMC     JMO    81/05/22 
*         MODSET CORRECTS FMC SO IT CAN BE ASSEMBLED WITHOUT
*         TSP DEFINED. FEATURE DPSR 033484. 
* 
* 
* HPA1     TEF  81/06/11
*          MODSET HPA025724 CORRECTS THE PROBLEM OF MMF = X NOT BEING 
*          REPORTED IN THE "REPORTS CALLED" SECTION OF THE CONTROL CARD 
*          PARAMETER REPORT.
* 
* 
* HPA4    SLS  81/06/08 
* 
*        MODSET HPA025742  CORRECTS THE PROBLEM OF NOT
*        BEING ABLE TO USE THE CHANGE COMMAND FOR SITE
*        IDENTIFICATION INFORMATION.
* 
* 
* HPA4    SLS  81/06/08 
* HPA7
* 
*        MODSET HPA033938 CORRECTS THE PROBLEM OF THE LAST
*        TRANSMIT DATE APPEARED IN THE LAST ENTRY DATE
*        FIELD. 
* 
* 
* MALET10 JMO    81/06/01 
*         MODSET CORRECTS MALET10 SO THE FLASHING MESSAGE ON A
*         SEND COMMAND GETS CLEARED OUT AND AN OPERATOR GAVE
*         GO MESSAGE GETS PRINTED AT A TERMINAL. DPSR 033403. 
* 
* 
* FMD     JMO    81/06/05 
*         MODSET ADDS THE APPLICATIONS AND APPENDIX PORTIONS
*         OF FMD TO THE EXTERNAL DOCUMENTATION. DPSR 037167.
* 
* 
* HPA3    SLS  81/06/11 
* HPA38 
* 
*        MODSET HPA033456  CORRECTS SUMMARY REPORT ERRORS FOR 
*        SECDED PHASE II UNIQUE ERRORS. 
* 
* 
* FMC       HNS 81/06/10
* 
*         FMC02 WILL NOT LOAD CONTROLWARE.
*         1. ADD FULL AUTOLOAD DISABLED MESSAGE.
*         2. ADD CONTROLWARE VERSION LOADED MESSAGE.
*         3. REDUCE LENGTH OF FMC02 SOURCE. 
*         4. ADD FULL AUTOLOAD DISABLE MESSAGE. 
*         5. MAKE LENGTH ERRORS MORE DESCRIPTIVE. 
*         6. ADD SCRATCH FILE MISSING OR EMPTY CHECK AND MSG. 
*         7. ADD CONTROLWARE DATA CHECK TO FMC02 AND FMC31. 
*         DPSR 035554 
* 
* 
* HPA2        JRJ 81/06/10
* HPA39 
* 
*     NOTE    MODSET DIMA593 HAS TO BE CONCURRENTLY 
*     NOTE    INSTALLED IN PROGRAM LIBRARY - REL2B
*     NOTE    DECK - NORM 
* 
* 
*     DECK     HPA2 
*             SUBROUTINE - ERRSET2
*             THE SORT/MERGE OWN CODE EXIT 1 SUBROUTINE ERRSET2 
*             OF HPA2 HAS THE SEF(LCN) CHANGES DELETED. 
* 
*     DECK    HPA39 
*             SUBROUTINE - CHG39
*             ADD A *GO TO* BRANCH TO STOP THE PRINTING 
*             OF A *NAD CHANGED* MESSAGE AFTER
*             PRINTING A CHANGE DATE MESSAGE
* 
*             CHANGE FORMAT OF NUMBER OF DEFINED BUFFERS
*             FROM Z4 TO Z2.
* 
*             CHANGE FORMAT OF NAD CHANGE MESSAGE TO INCLUDE
*             A BLANK IN FRONT OF THE NAD.
* 
*             SUBROUTINE - R7439
*             INITIALIZE VARIABLE *REVLVL* WHEN R7439 IS ENTERED
* 
*             MODIFY TEST OF CHANGE IN PPU, EST, AND CHL
*             TO INCLUDE TYPE OF NAD (LOCAL/REMOTE) 
* 
* 
* 
* FMD       HNS 81/06/04
* 
*         FMD29/30 FAIL TO TEST THE ADDRESS SWITCHES CORRECTLY. 
*         1. ADD PICTURE TO DISPLAY MANUAL INTERVENTION ON TERMINAL.
*         2. ADD TESTS FOR STATUS WORD ONE TO FMD29.
*         3. CORRECT MASKS FOR STATUS CHECK IN FMC29. 
*         4. ADD ERROR MESSAGES 0503F AND 05040 TO FMD29. 
*         5. CORRECT AND ADD MASKS FOR STATUS CHECK IN FMC30. 
*         6. CORRECT SPELLING ON FMD42 SEEK TIME MESSAGE. 
*         DPSR 037730 
* 
* 
*         DPSR 033533 
* HPA     REF  07/02/81 
*         MODSET PROCESSES SEF RECORDS CONTAINING FEDERAL STANDARD
*         CHANNEL (FSC) TAPE ERRORS AND GENERATES DETAIL, DETAIL
*         EXTENDED AND ANALYSIS REPORTS.  IN ADDITION, THE FSC TAPE 
*         DATA WILL BE INCLUDED IN HPA SUMMARY AND ERROR LOG REPORTS
*         AS AN MT OR NT DEVICE TYPE.  REPORTS ARE AVAILABLE IN BOTH
*         132 AND 80 COLUMN FORMATS.  EACH FSC TAPE ERROR RESIDES 
*         IN TWO CONTINUOUS SEF RECORDS, SINCE THE INFORMATION COULD
*         NOT BE PACKED IN ONE 8 WORD RECORD.  THE DETAIL EXTENDED
*         REPORT DETAILS EACH BIT OF THE 24 HEX SENSE BYTES.
* 
* 
* MALET   JMO    81/06/09 
*         MODSET ENHANCES MALET SO IT CAN BE INTERRUPTED
*         FROM A TERMINAL WITHOUT ABORTING. ENHANCEMENT 
*         DPSR 037673.
* 
* 
* MALET10 JMO    81/06/09 
*         MODSET ENHANCES MALET SO IT CAN BE INTERRUPTED
*         FROM A TERMINAL WITHOUT ABORTING. ENHANCEMENT 
*         DPSR 037673.
* 
* 
* MALET12 JMO    81/06/09 
*         MODSET ENHANCES MALET SO IT CAN BE INTERRUPTED
*         FROM A TERMINAL WITHOUT ABORTING. ENHANCEMENT 
*         DPSR 037673.
* 
* 
* T7X     MSF    81/05/18 
*         MODSET CORRECTS THE PLOTS FOR FORWARD AND REVERSE 
*         START TIMES IN MODULES 31 AND 32 OF T7X FOR 100 
*         AND 150 IPS UNITS.  DPSR 014131.
* 
* 
* COMHPAERT, HPACOM39, HPA, HPA39  JRJ 81/07/06 
* 
*         MODSET HPA033535 ADDS CODE TO GENERATE ADDITIONAL LOOSELY COUPLED 
*         NETWORK (LCN) REPORTS.
* 
* 
* 
* MALET   JMO    81/07/09 
*         MODSET CORRECTS ILLEGAL TERMINAL REQUEST WHEN USING A 
*         BATCH JOB INTRODUCED BY MODSET MAL37673A. DPSR 033537.
* 
* 
* HISTORY RBD   81/07/14
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO CL130PL.
* 
* 
* FTP     MSF    81/24/06 
*         MODSET CLEARS MAINTENANCE STATUS IN MODULES 47 & 47A
*         OF FTP. THIS WILL LEAVE THE PRINTER IN A CONDITION
*         THAT IS USEABLE BY JANUS UNDER NOS/BE. DPSR 023778. 
* 
* 
* HPA33    SLS  81/06/18
* 
*        MODSET HPA035302 CORRECTS THE PROBLEM OF HPA ERRONEOUSLY 
*        REPORTING AN ERROR AS A 6681 INT/EXT REJECT ON A 66X 
*        TAPE SUBSYSTEM.
* 
* 
* HPA1    RAS    81/04/30 
*         MODSET HPA035403 CORRECTS THE BYPASS PARAMETER (B=EXXXX)
*         SO THAT LEADING ZEROS ARE NOT REQUIRED WHEN ENTERING ERROR
*         CODES ON THE HPA CONTROL STATEMENT. 
* 
* 
* HPA8     LWW  81/07/01
* 
*          MODSET INSTALLS CODE TO SUPPRESS THE HISTORY UPDATED 
*          REPORT, WHEN THE X=BF PARAMETER WAS SPECIFIED. 
* 
* 
* HPA1    DDN    07/10/81 
*         MODSET WILL PRINT AN INFORMATIVE ERROR MESSAGE
*         IF MORE THAN ONE X OR AN X AND R PARAMETER ARE
*         SELECTED. 
*         DPSR 038218 
* 
* 
* INSTLDKS JMO   81/07/20 
*         MODSET CORRECTS THE NOSBE R6 INSTALL DECK SO OVERFLOW 
*         IN PASS 1 ERRORS DO NOT OCCUR WHILE ASSEMBLING MALET. 
*         DPSR 033545.
* 
* 
* INSTLDKS JMO   81/07/20 
*         MODSET CORRECTS THE NOSBE R5 INSTALL DECK SO THE EDITLIB
*         DIRECTIVE FOR MALET IS CORRECT. DPSR 033547.
* 
* 
* HPA8    SLS  81/07/28 
* 
*        MODSET HPA033708 CORRECTS THE DATE IN THE HISTORY UPDATE 
*        REPORT WHEN THERE IS ONLY ONE DAY IN THE HISTORY.
* 
* 
* HPA34    LWW  81/07/01
*          MODSET CORRECTS LOOP WHEN SORTING DATA FOR "POSITION ANALYSIS
*          SUMMARY".
* 
* 
* HPA32   SLS  81/07/24 
* 
*        MODSET HPA033709  CHANGES THE SHR DESCRIPTION FIELD TO MATCH 
*        THE DETAIL DESCRIPTION FOR COMM. SUBSYSTEM HDWR ERROR CODE.
* 
* 
* MALET   JMO    81/07/29 
*         MODSET CORRECTS THE ASSIGNMENT OF AN ILLEGAL DEVICE 
*         FROM A TERMINAL. DPSR 033554. 
* 
* 
* MALET11 JMO    81/07/29 
*         MODSET CORRECTS THE ASSIGNMENT OF AN ILLEGAL DEVICE 
*         FROM A TERMINAL. DPSR 033554. 
* 
* 
* FMC       HNS 81/06/25
* 
*         FMC02 FAILS TO LOAD 8435 WORD CONTROLWARE.
*         DPSR 037747 
* 
* 
* HPA3     PWL  81/07/23
* HPA38    MODSET HPA033553 GENERATES S1/S3 SECDED II 
*          AND MAINTENANCE REGISTER REPORTS.
* 
* 
*         DPSR 033563 
*  HPA    REF  08/04/81 
*         MODSET PROCESSES SEF RECORDS CONTAINING FEDERAL STANDARD
*         CHANNEL (FSC) DISK ERRORS AND GENERATES DETAIL, DETAIL
*         EXTENDED AND ANALYSIS REPORTS.  IN ADDITION, THE FSC DISK 
*         DATA WILL BE INCLUDED IN HPA SUMMARY AND ERROR LOG REPORTS
*         AS A DX, DY, DZ OR DA FSC DEVICE TYPE.  REPORTS ARE AVAIL-
*         ABLE IN BOTH 132 AND 80 COLUMN FORMATS.  EACH FSC DISK ERROR
*         RESIDES IN TWO CONTINUOUS SEF RECORDS, SINCE THE INFORMATION
*         COULD NOT BE PACKED IN ONE 8 WORD RECORD.  THE DETAIL EX- 
*         TENDED REPORT DETAILS EACH BIT OF THE 24 HEX SENSE BYTES. 
* 
* 
* HISTORY DJU   81/08/05
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO CL131PL.
* 
* 
* 
* 
* FMC       HNS 81/06/18
* 
*         FMC DOES NOT ISOLATE LOST DRIVE CLOCK.
*         1. MODIFY FMC25 TO NOT USED FMD DRIVE.
*         2. ADD CODE TO FMC29 TO ISOLATE LOST DRIVE CLOCK. 
*         3. DELETE FMC24.
*            (SEE FMC037737)
*         4. CONVERT AND MOVE FMC24/25 TO FMC40/41 RESPECTIVELY.
*         5. ADD LOST CONTROL WORD STATUS TEST TO FMC25.
*         6. ADD SYNC BYTE SEARCH STATUS TEST TO FMC25. 
*         7. CORRECT FMC25 DOCUMENTATION. 
*         DPSR 037738 
* 
* 
* HPA34   DDN    81/08/04 
*         MODSET CORRECTS A PROBLEM IN WHICH THE
*         ERROR MESSAGE FOR DETAIL STATUS MISCOMPARE
*         IS PRINTED EVEN THOUGH A MISCOMPARE HAS 
*         NOT OCCURRED. 
*         DPSR 033542 
* 
* 
* HPA3    DDN    07/31/81 
*         THIS MODSET CORRECTS A PROBLEM IN WHICH THE LAST
*         RECORD OF SEF BEFORE EOF CAN BE MISSED FOR DETAIL 
*         AND ANALYSIS REPORTS.  THE FAILURE OCCURS ONLY
*         ON RT=44,74,33 THAT ARE NOT A CONTINUE RECORDS. 
*         DPSR 35419. 
* 
* 
* HPA8    DDN    07/17/81 
*         HPA GETTING RM 100 (POSITION BEYOND FILE
*         BOUNDS) WHEN UPDATING HISTORY FILES CON-
*         TAINING ONLY TWO RECORDS (STATISTICS AND
*         ONE SHR RECORD) WITH A SEF CONTAINING 
*         DATA FOR THE SAME DAY AS THE HISTORY. 
*         DPSR 039892 
* 
* 
* HPA7    SLS  81/07/31 
* 
*        MODSET HPA033705  CORRECTS SEVERAL SPA PROBLEMS INCLUDING -
*                        - WRONG PRINT STATEMENT FOR CYBERLOG COMMENTS
*                        - WRONG AND MISSING SEQUENCE NUMBERS 
*                        - INCORRECT LOAPR AND FORMAT STATEMENTS FOR
*                            DEADSTART MESSAGES 
* 
* 
* HPA36   SLS  81/03/30 
* 
* 
*         CORRECTS LCME SECDED BANK MISSING BITS (117 AND 116). 
* 
* MALET11 JMO    81/07/21 
*         MODSET CORRECTS THE PROBLEM OF RUNNING MALET TEST 
*         CSU ALWAYS ON CSU ZERO REGARDLESS OF WHICH CSU IS 
*         ASSIGNED BY EST ORDINAL. DPSR 011018. 
* 
* 
* HPA4    SLS  81/08/12 
* 
*        MODSET HPA033710  CORRECTS THE PROBLEM OF GARBAGE IN 
*        CHANGE = D  DUE TO NEW ERROR CODE INTRODUCED BY DSA. 
* 
* 
* HPA5     PWL  81/08/12
*          MODSET HPA035420 CONSOLIDATES LIKE ERRORS FOR
*          THE SAME DEVICE OF DIFFERENT DAYS ONTO THE SAME
*          LINE IN THE SUMMARY ERRORLOG (S=1) REPORT WITH 
*          THE R PARAMETER. 
* 
* 
* HPA1     LWW  81/07/01
* 
*          MODSET INSTALLS CODE TO IMPLEMENT A NEW HISTORY WINDOW 
*          PARAMETER FORMAT OF HW=DD, WHERE DD SPECIFIES THE NUMBER 
*          OF DAYS SELECTED STARTING FROM THE CURRENT SYSTEM DATE.
* 
* 
*         DPSR 033581 
*  HPA    REF  08/20/81 
*         MODSET MAKES CORRECTIONS TO FEDERAL STANDARD CHANNEL (FSC)
*         DETAIL REPORTS IN HPA.
* 
* 
* DTC       HNS 81/08/10
* 
*         DTC - CANNOT DETERMINE FAILING MODULE.
*         1. ADD MODULE NUMBER/TITLE MESSAGE TO LINE 2. 
*         2. CORRECT MODULE NUMBER/TITLE IN FMC01A. 
*         3. DELETE REDUNDANT LINE 2 MSG STATEMENTS.
*         4. ADD TEST TITLE LINE TO LINE 1 IN DTC98C/DTC98D.
*         5. ADD LINE/ERROR CODE MESSAGE TO DTC06A/07A/08A. 
*         6. CORRECT LINE/ERROR CODE MESSAGE IN DTC14A/16A. 
*         DPSR 039459 
* 
* 
* FMC       HNS 81/08/11
* 
*         FMC DOES NOT CHECK FOR CH ERROR(I.E. NO CABLES) 
*         DPSR 039461 
* 
* 
* DTC       HNS 81/08/07
* 
*         DTC02 FAILED TO ISOLATE BUSIN 7 FAILURE(B10-2PA13)
*         DPSR 035558 
* 
* 
* FMC       HNS 81/06/18
* 
*         FMC DOES NOT DETECT A CONTROLLER CH. ACTIVE ERROR.
*         1. ADD MISSING ABORT MESSAGES TO FMC290.
*         2. ADD .RES DRIVE. ABORT ISOLATION TO FMC29.
*         3. CHANGE READCW TO READ COMMAND TO ISOLATE CH.ACT.ERR. 
*         4. ADD CONTROLLER CHANNEL ACTIVE ERROR MSG TO FMC29A. 
*         5. ADD MODULE FMC29B FOR LOST DRIVE CLOCK ERROR MSGS. 
*         6. ADD CTRLR PROC. INSTR. TIMEOUT ERROR MSG TO FMC29B.
*         7. ADD CTRLR AND/OR DRIVE BUSY ERROR MSG TO FMC29B. 
*         8. CHANGE * TO / ON FMC29(S) SEPERATING COMMENTS. 
*         9. IMPROVE ISOLATION IN FMC29.
*         10.ADD MISSING ABORT MESSAGES TO FMC330.
*         11.ADD DETAILED STATUS DISPLAY TO FMC29 ERRORS. 
*         12.ADD CHECKWORD TYPE TO MSGS IN FMC29A.
*         DPSR 037737 
* 
* 
* FMD       HNS 81/06/19
* 
*         FMD DOESNT INDICATE POSSIBLE CONTROLLER FAILURE.
*         DPSR 037770 
* 
* 
* D88       HNS 81/06/18
* 
*         D88 GIVES WRONG PSFG ON LOST DRIVE CLOCK ERROR. 
*         DPSR 035986 
* 
* 
* 
* HPA     JRJ 81/08/28
* 
*                ******** 
*                * NOTE * 
*                ******** 
* 
* 
*         THIS MODSET MUST BE CONCURRENTLY INSTALLED WITH DIMA617 AND 
*         DIMA626 INTO NORM ON REL2B. 
* 
* 
*                ************ 
*                * END NOTE * 
*                ************ 
* 
* 
*         MODSET HPA48054 ADDS CODE TO HPA TO PROCESS LCN TYPE 3
*         INTERFACE ERRORS FOR CYBER170 AND IBM.
* 
* 
* 
* MALET30 JMO    81/08/21 
*         MODSET CORRECTS THE LEVEL NOT BEING RETURNED TO A TERMINAL
*         ON NOSBE. DPSR 033568.
* 
* 
* D44     MSF    81/08/04 
*         MODSET D44039478 CORRECTS MODULE 03 TO OUTPUT REGISTERS 
*         B0 - B7 IN THE ERROR DISPLAY.  B1 GIVES THE LOOP COUNT
*         OF A MODULE ERROR AND B4 GIVES THE LOOP COUNT OF A
*         PRODUCT OVERLAY ERROR.  THE MODSET ALSO DIFFERENTIATES
*         MODULE ERRORS FROM PRODUCT OVERLAY ERRORS.  DPSR 039478.
* 
* 
* DTC       HNS 81/08/28
* 
*         DTC98H ACCESS IN ERROR. 
*         1. CORRECT ACCESS DESIGNATORS IN DTC98H.
*         2. CORRECT ACCESS DESIGNATORS IN DTC98L.
*         DPSR 039471 
* 
* 
* MALET11 GLG    80/12/18.
*         MODSET CORRECTS MALET11 TO CHECK FOR ILLEGAL ACCESS 
*         LEVELS 5,6,7 ON RMS DEVICES. PROBLEM REPORTED ON DPSR 37947.
* 
* 
* HISTORY AKJ   81/09/10
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO CL132PL.
* 
* 
* CR1     MSF    81/08/25 
*         MODSET CR1043633 CORRECTS CR1 EXTERNAL DOCUMENTATION
*         TO INCLUDE AN OVERVIEW, RESTRICTIONS, RUN PARAMETERS, 
*         PROGRAM AND MODULE DESCRIPTIONS, ERROR PROCESSING AND 
*         MESSAGES ISSUED, MAINTENANCE PHILOSOPHY AND AN IMAGE
*         OF THE CR1 TEST DECK.  DPSR 043633. 
* 
* 
* FMD       HNS 81/08/28
* 
*         FMD72 CH NOT ASSIGNED.
*         DPSR 033564 
* 
* 
* HPA35    PWL  81/09/04
*          MODSET HPA033574 ADDS CODE TO PROCESS THE C3 PART
*          OF SCLN ACCOUNT FILE MESSAGES--NUMBER OF BLOCKS
*          TRANSMITTED OR RECEIVED IN ERROR.
* 
* 
* HPA38    PWL  81/08/24
* HPA8     MODSET HPA033556 ADDS 80 COLUMN REPORTS, REFORMATES
* HPA9     THE 132 COLUMN REPORTS FOR MSS.
* 
* 
* HPA7     LWW  81/07/30
*          MODSET COMPUTES SYSTEM AVAILABILITY PERCENTAGE AND 
*          CHANGES LAST COLUMN IN A=SY REPORT TO REFLECT
*          PREVIOUS MONTHS DATA 
* 
* 
* LCM      MRL 81/09/01 
* 
*          CORRECTION OF LCM MESSAGE FORMAT 
*          1. CORRECT MESSAGE HEADER ON A COMPARE ERROR 
* 
* HPA3    DDN    81/08/07 
*         MODSET CORRECTS A PROBLEM IN WHICH THE
*         DATES CONTAINED IN THE ANALYSIS REPORTS 
*         ARE NOT CONSISTANT WITH THE DATES IN THE
*         HISTORY FILE. 
*         DPSR 032410 
* 
* 
* TFF     JMO    81/09/09 
*         MODSET CORRECTS MODULES TFF05, 06 AND 10 TO CHECK FOR 
*         THE PROPER AMOUNT OF WORDS TRANSMITTED ON MULTIWORD 
*         INPUTS AND OUTPUTS. DPSR 046915.
* 
* 
* LP1     MSF 81/09/01
*         MODSET CORRECTS MODULES (04,05,06,07,09,10,14,24) OF
*         LP1 TO ISOLATE THE FAILING COLUMN NUMBER AND FAILING CHARACTER OF 
*         A PRINT ERROR.  DPSR 027318.
* 
* 
* HPA2     PWL  81/09/17
*          MODSET HPA040079 REPORTS THE FAILING CHANNEL 
*          IN THE INTERVENTION REPORT.
* 
* 
* HPA7    SLS  81/09/15 
* 
*        MODSET HPA033582  CORRECTS PROBLEM OF AN UNDEFINED VARIABLE
*        (IERR) IN SUBROUTINE DL1CY7. 
* 
* 
* HPA4    SLS  81/09/16 
* HPA7
* 
*        MODSET HPA039560  CORRECTS THE PROBLEMS OF - 
*        - DELETES NOT BEING REMOVED FROM SHR WHICH CAUSED
*          FILE OVERFLOW WHEN ADDING MORE HARDWARE CONFIGURATION. 
*        - INSERT LIST NOT STAYING IN THE ORDER WHICH IT WAS
*          ENTERED. 
*        - ADDED CY AND MMF TO SHR 50.
* 
* 
* HPA9    DDN    81/09/16 
*         THE TAPE MEDIA SCRATCH FILE IS NOT SORTED 
*         BY DAY AND AS A RESULT THE TAPE MEDIA 
*         SUMMARY REPORTS ARE NOT IN CORRECT ORDER
*         AND/OR NOT ALL DATES INCLUDED.  THIS MODSET 
*         WILL CORRECT THE PROBLEM. 
*         DPSR 039557.
* 
* 
* HPA2    SLS  81/09/16 
* 
*        MODSET HPA039563  ALLOWS CHANNEL, EQUIPMENT, AND UNIT
*        NUMBER TO BE ENTERED WITHOUT LEADING ZEROS 
*        WHEN CREATING THE HARDWARE CONFIGURATION TABLE.
* 
* 
* HPA3    SLS  81/09/17 
* HPA5
* HPA8
* HPA9
* 
*        MODSET HPA039564  CHANGES THE PRINT FORMAT OF THE HUID 
*        FROM OCTAL TO DECIMAL(INTEGER).
* 
* 
* HPA9    SLS  81/09/22 
* 
*        MODSET HPA039566 CORRECTLY CONVERTS THE HUID TO DECIMAL
*        IN THE MESSAGE "PLEASE RUN DIAGNOSTICS ON UNIT XX" 
*        WHEN RUNNING IN MMF MODE.
* 
* 
* HPA3     PWL  81/09/15
*          MODSET HPA033572 BYPASSES THE COUNTING OF 2550 
*          MESSAGES AGAINST CHANNEL 0.
* 
* 
*         DPSR 034707 
*   HPA   REF 09/25/81
*         MODSET ENHANCES THE TAPE UNIT ANALYSIS REPORT WITH A RANKED 
*         LIST OF VSNS HAVING THE GREATEST NUMBER OF RECOVERED ERRORS.
*         ONLY THE 20 MOST ERRONEOUS VSNS WILL BE REPRESENTED; VSNS 
*         WITH LESS THAN 3 ERRORS WILL BE EXCLUDED.  THUS, A TOOL FOR 
*         EVALUATING UNIT VS. MEDIA PERFORMANCE IS PROVIDED, AS PRO-
*         POSED IN SOLUTION DAP ARH 4352. 
* 
* 
* HISTORY RBD   81/10/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO CL133PL.
* 
* 
* 
* D44     MSF    81/09/17 
*         MODSET CORRECTS D44 MODULE 36 TO GO TO END
*         OF TEST.  DPSR 041310.
* 
* 
* HPA1    REH    07/01/81 
*         THIS MODSET ADDS A CHECK FOR ERRORS AFTER 
*         A CALL TO IVAL1.
*         DPSR 039573 
* 
* 
* FMC       HNS 81/09/30
* 
*         FMC01 ERROR MESSAGE 61001 LACKS PROD.OVERLAY MESSAGE. 
*         DPSR 033588 
* 
* 
* HPA      PWL  81/09/30
*          MODSET HPA007271 CORRECTS THE BUILD LEVEL ID 
*          IN THE RELEASED HPA PL.
* 
* 
* COMHPAERT    PWL  81/09/28
*          MODSET HPA033584 ENABLES 'FUNCTION TIME OUT' 
*          MESSAGES TO BE PROCESSED AS CHANNEL MESSAGES.
* 
* 
* HPA36    SLS  81/09/16
* 
*        MODSET HPA015794  ADDS THE BIT TO THE SCR ANALYSIS REPORT
*        AND REMOVES THE ROW SELECT, CHIP SELECT AND BOARD
*        FROM THE SCR ANALYSIS AND DETAIL REPORTS.
* 
* 
* HPERS   SLS  81/09/29 
* HPA2
* HPA3
* HPA38 
* 
*        MODSET HPA039562 CORRECTS THE PROBLEM OF WHEN DSA AND MMF
*        ARE BOTH SELECTED FICTITIOUS JOB NAME OF CONTINU APPEARS 
*        IN DETAIL REPORTS AND THE DSA PROCESSING IS NOT DONE.
* 
* 
* MALETP3 JMO    81/10/20 
*         MODSET CORRECTS MUX COMPILER SO THE CORRECT PARAMETER 
*         REGISTER ADDRESS IS USED WHEN COMPILING THE MUX DIAGS.
*         DPSR 034756.
* 
* 
* HPA38    SLS  81/10/12
* 
*        MODSET HPA034715 CORRECTS PROBLEMS IN THE
*        M2 SECDED ERROR REPORTS. 
* 
* 
* HPA37    PWL  81/10/20
*          MODSET HPA034714 SHORTENS THE EXTENDED DETAIL ERROR
*          REPORT FOR MSS.
* 
* 
* F44      LJC  81/10/29
*          THIS MODSET ADDS THE NEW F44 
           TO THE PROGRAM LIBRARY.
* 
* 
* FMU     JMO    81/10/22 
*         MODSET CLARIFIES THE ARCHIVE MESSAGE IN FMU17.
*         DPSR 034741.
* 
* 
* FLM     LJC  81/10/30 
*         THIS MODSET ADDS THE NEW FLM
*         TO THE PROGRAM LIBRARY. 
* 
* 
* FSM     LJC  81/10/30 
*         THIS MODSET ADDS THE NEW FSM
*         TO THE PROGRAM LIBRARY. 
* 
* 
* FFU     LJC  81/10/30 
*         THIS MODSET ADDS THE NEW FFU
*         TO THE PROGRAM LIBRARY. 
* 
* 
* F7X      LJC  81/10/30
*          THIS MODSET ADDS THE NEW F7X 
*          TO THE PROGRAM LIBRARY.
* 
* 
* HISTORY RBD   81/11/02
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO CL134PL.
* 
* 
* 
* F88      LJC  81/10/29
*          THIS MODSET ADDS THE NEW F88 
*          TO THE PROGRAM LIBRARY.
* 
* 
* HISTORY KES   82/01/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO CL135PL.
* 
* 
* 
* 
* HPA2    SLS  81/10/26 
* 
*        MODSET HPA034757 ADDS DOCUMENTATION TO MATCH2 AND CONFIG2. 
* 
* 
* D88     MSF    81/10/28 
*         MODSET CORRECTS MODULE 23 OF D88 TO ADD AN ABORT
*         PROCESSOR TO PROCESS THE FIRST RES DRIVE, READ, 
*         AND MARGINS ABORT.  DPSR 019285.
* 
* 
* D88     MSF    81/10/28 
*         MODSET CORRECTS MODULE 44 OF D88 TO RUN ALL READ
*         MARGINS SELECTED IN PARAMETER P7.  DPSR 042598. 
* 
* 
* ATC     MSF    81/09/16 
*         MODSET CORRECTS ATC MODULE 15 TO NOT RUN TCU
*         LOOP WRITE TO READ AT 200 IPS GCR IN SIX-BIT
*         MODE.  DPSR 038722. 
* 
* 
* CR1     MSF    81/10/07 
*         MODSET CORRECTS MODULES 04, 04A, 04B, 04C AND 
*         04D OF CR1 TO REPORT FOUR DATA COMPARE ERRORS 
*         BEFORE GOING TO END OF TEST.  DPSR 041448.
* 
* 
* MALET   JMO    81/11/13 
*         MODSET CORRECTS THE INTERNAL DOCUMENTATION OF MALET 
*         DEVICE CODES. DPSR 027329.
* 
* 
* HPA35    PWL  81/10/26
*          MODSET HPA034772 DELETES "BLOCKS RETRANSMITTED" AND
*          "UPLINE BREAK" SUB-HEADINGS FOR 2550 NAM AND INTER-
*          COM 5 TERMINAL DETAIL REPORTS. 
* 
* 
* HPA3     SLS  81/11/03
* HPA38 
* 
*        MODSET HPA034771 CORRECTS THE CHECK FOR CONTINUATION.
* 
* 
* HPA1    DDN    11/05/81 
*         MODSET ADDS A JULIAN DATE FEATURE TO THE *HW* 
*         PARAMETER.  IMPLEMENTATION ALLOWS THE JULIAN
*         DATE TO BE USED IN THE SAME MANNER AS THE 
*         CALENDAR DATE ENTRIES.
*         DPSR 039572 
* 
* 
* MALET   JMO    81/10/21 
*         MODSET CORRECTS MALET TO ADD XTEXT FOR CHANNEL TABLES 
*         FOR NOS R6. DPSR 034766.
* 
* 
* MALET10 JMO    81/10/23 
*         MODSET CORRECTS MALET10 SO IT ASSEMBLES AND EXECUTES
*         CORRECTLY WITH NOS R6. DPSR 034766. 
* 
* 
* MALET11 JMO    81/10/23 
*         MODSET CORRECTS MALET11 SO IT ASSEMBLES AND EXECUTES
*         CORRECTLY WITH NOS R6. DPSR 034766. 
* 
* 
* MALET   JMO    81/10/30 
*         MODSET CORRECTS MALET SO IT WILL ISSUE A MESSAGE TO 
*         THE DAYFILE IF THE RANDOM FILE IS FULL. DPSR 046916.
* 
* 
* COMHPAERT    PWL  81/11/09
*              MODSET HPA034597 ADDS ERROR CODE 403 (FUNCTION 
*              TIME OUT) TO HPA32 FOR THE UNIT RECORD EQUIP-
*              MENTS. 
* 
* 
*          DPSR HPA016366 
* HPERS    RTG  81/10/26
*          MODSET HPA016366 UPDATES HPERS TO INCLUDE SPA
*          RECORD FORMAT INFORMATION
* 
* 
* MALET   MSF    81/10/05 
*         MODSET CORRECTS A DOCUMENTATION ERROR IN THE
*         CODES FOR DEVICES TABLE FOR THE 580-20 LINE 
*         PRINTER.  DPSR 027325.
* 
* 
* DECK    MSF    81/11/04 
*         MODSET CORRECTS MODULE 36 OF T7X TO INFORM THE
*         USER THAT THE MODULE RUNS IN PHASE DENSITY ONLY.
*         DPSR  040087. 
* 
* 
* MALET   JMO    81/07/14 
*         MODSET CORRECTS THE POSSIBILITY OF CALLING MULTIPLE COPIES
*         OF SBP INTO ALL AVAILABLE PPS UNDER SPECIAL CONDITIONS. 
*         MODSET DIMA577 CORRECTS DECK SBP. DPSR 033544.
* 
* 
* MALET10 JMO    81/07/14 
*         MODSET CORRECTS THE POSSIBILITY OF CALLING MULTIPLE COPIES
*         OF SBP INTO ALL AVAILABLE PPS UNDER SPECIAL CONDITIONS. 
*         MODSET DIMA577 CORRECTS DECK SBP. DPSR 033544.
* 
* 
* MALET12 JMO    81/07/14 
*         MODSET CORRECTS THE POSSIBILITY OF CALLING MULTIPLE COPIES
*         OF SBP INTO ALL AVAILABLE PPS UNDER SPECIAL CONDITIONS. 
*         MODSET DIMA577 CORRECTS DECK SBP. DPSR 033544.
* 
* 
* HPA2     PWL  81/11/13
*          MODSET HPA034799 PICKS UP HUID FROM FMD SWITCH SETTINGS
*          IN DETAIL STATUS.
* 
* 
* RT5     MSF    81/11/11 
*         MODSET CORRECTS RT5 MODULE 6 TO RESERVE 
*         THE DEVICE AND CHANNEL IN THE SINGLE
*         CHARACTER SEQUENCE.  DPSR  035575.
* 
* 
* DTC     MSF    81/11/11 
*         MODSET CORRECTS DTC MODULE 12 TO DO A RES DRIVE,
*         AFTER A RETURN FROM THE MARGINS SUBROUTINE, BEFORE
*         ISSUING A READCW COMMAND.  DPSR 040090. 
* 
* 
* F7X     MSF    81/11/20 
*         MODSET CORRECTS F7X MODULE 980 TO DETECT TAPE PRESENT 
*         WHEN THE TAPE UNIT IS READY AND AT LOAD POINT.
*         DPSR  033451. 
* 
* 
* HPA2     PWL 81/11/30 
*          MODSET HPA042707 SENDS SORT MESSAGES TO THE DAYFILE
*          INSTEAD OF THE HPA OUTPUT WHEN HPSORT IS SPECIFIED.
* 
* 
* HPA      PWL  81/11/20
*          MODSET HPA034612 PICKS UP ALL 7 CHARACTERS OF THE VERSION
*          ID FOR HPA HEADER FROM EACH INTERNAL AND RELEASE BUILD.
* 
* 
* HPA36    SLS  81/12/03
* 
*        MODSET HPA039899 CORRECTS THE PROBLEM OF ECS READ PARITY 
*        AND WRITE PARITY ERRORS SHOWING UP AS UNUSED MESSAGES. 
* 
* 
* F44     JMO    81/11/19 
*         MODSET CORRECTS MODULE 14 OF F44 SO THE ERROR 
*         COUNT IS PRINTED TO THE DAYFILE. DPSR 033440. 
* 
* 
* F44     JMO    81/11/19 
*         MODSET CORRECTS F44 MODULE 13 SO A COMPARE ERROR
*         RESERVES THE DRIVE AFTER GOING TO THE ERROR PRO-
*         CESSOR. DPSR 033449.
* 
* 
* RT5     MSF    81/11/16 
*         MODSET CORRECTS RT5 DOCUMENTATION TO INFORM THE USER THAT IN
*         SIMULATOR MODE P2 DOES NOT CHANGE THE CHARACTER/BIT TIMES, THAT 
*         SIMULATOR CLOCK SET TO ANYTHING OTHER THAN 2000 BAUD WILL CAUSE 
*         RT5 TO FAIL, AND THAT AN INCORRECT SETTING OF THE SIMULATOR 
*         CLOCK WILL CAUSE FALSE ERRORS.  DPSR  035574. 
* 
* 
* NLM     MRL 81/09/17
* 
*         NLM GETS A SUBR ENTRY/EXIT ERROR
*         1. NLM02B HAS INCORRECT STACKING OF GOSUBS
*         2. END PREVIOUS SUBR BEFORE CALLING ANOTHER 
* 
* 
* F7X     MSF    81/12/03 
*         MODSET CORRECTS F7X MODULE 22 TO CHANGE THE ERROR 
*         CODE AT LINE 71 FROM 240 TO 241.  DPSR 033441.
* 
* 
* F7X     MSF    81/11/25 
*         MODSET CORRECTS F7X TO REMOVE OBSOLETE DETAILED STATUS
*         ERROR CODES, INCORPORATE NEW DETAILED STATUS ERROR CODES, 
*         AND TO ADD MODULE 987 TO PROCESS THE NEW DETAILED STATUS
*         ERROR CODES.   DPSR 033450. 
* 
* 
* FMD     MSF    81/12/08 
*         MODSET CORRECTS FMD MODULE 34 TO POSITION THE POSITIONER
*         TO CYLINDER 0 PRIOR TO THE ISSUE OF THE RTZ COMMAND WHEN IN 
*         A SHARED ENVIRONMENT AND HEAVY SYSTEM ACTIVITY. DPSR 033066.
* 
* 
* HPA2    SLS  81/12/22 
* 
*        MODSET HPA034611  CORRECTS A DUPLICATE DELETION IN 
*        MODSET HPA039563.
* 
* 
* HPA34    PWL  81/12/17
*          MODSET HPA034608 ADDS RT FOR RETRY COUNT IN DISK 
*          DETAIL REPORT SUBHEADER. 
* 
* 
*         DPSR 034613 
*  HPA    REF 12/14/81
*         MODSET REMOVES THE UNIT TYPE FROM THE DETAIL LINE OF TAPE 
*         REPORTS: FROM ERROR MESSAGE AND CUMULATIVE STATUS REPORTS,
*         FOR ALL DEVICE TYPES (60X/65X, 66X AND 67X) AND FOR 80 OR 
*         132 COLUMN FORMATS.  REASON: THE CURRENTLY REPORTED UNIT
*         TYPE IS EITHER INACCURATE (REFLECTS THE TCU RATHER THAN 
*         TU CAPABILITY) OR INVALID (STATUS WORDS NOT PRESENT FOR 
*         DETERMINATION).  SINCE THE ACTUAL UNIT TYPE REFLECTS THE
*         CONTROLLER TYPE, THE CORRECTED FIELD BECOMES REDUNDANT
*         INFORMATION AND THUS EXPENDABLE.  (ONE EXCEPTION: GCR 
*         UNIT TYPE FOR 67X CONTROLLERS. HOWEVER, THIS UNIT TYPE
*         IS OBVIATED BY THE DENSITY.)
* 
* 
*         DPSR 034616 
*  HPA    REF 12/29/81
*         MODSET ENABLES A COMPLETE LIST OF SELECTED HPA REPORTS, AS
*         SPECIFIED BY THE INPUT PARAMETERS.  THE LIST APPEARS AUTO-
*         MATICALLY, ON THE FIRST PAGE OF HPA OUTPUT, FOLLOWING THE 
*         FILE ASSIGNMENT SECTION.  HPA WAS NEGLECTING TO LIST
*         REPORTS SELECTED AFTER THE HISTORY WINDOW (HW) PARAMETER. 
* 
* 
* HPA5     PWL  81/12/21
*          MODSET HPA034633 ADVANCES THE PRINT LINE COUNT 
*          IN THE SYSTEM PERFORMANCE SUMMARY REPORTS. 
* 
* 
*         DPSR 033594 
*  HPA    REF 12/29/81
*         MODSET EDITS SELECTED SEF DATA - BOTH BEFORE AND AFTER IT IS
*         SORTED.  SPECIFICALLY, IT CHECKS THE RECORD TYPE, DEVICE TYPE 
*         AND THE DATE FOR VALIDITY.  ANY RECORDS WHICH CONTAIN UNQUALI-
*         FIED DATA ARE PRINTED AND DISCARDED, THUS ALERTING THE USER 
*         AND PROTECTING HPA REPORTS AND HISTORY FILE.  IN ADDITION,
*         MODSET SCREENS INFORMATION ENTERED WITH THE "DATE" PARAMETER, 
*         TO PREVENT A FATAL FORTRAN EXECUTION ERROR. 
* 
* 
* MALET   JMO    81/12/17 
*         MODSET CORRECTS MALET SO THE TERMINAL INTERUPT
*         WILL CHANGE THE NAME OF INPUT FILE BACK TO INPUT
*         IF IT HAS BEEN CHANGED. DPSR 034630.
* 
* 
* HISTORY GLG   82/01/14
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO CL136PL.
* 
* 
* 
* 
* SKEDULR JES    81/07/13 
*         THIS MODSET CORRECTS SKEDULR SUCH THAT APR CALLS TO EXECUTE 
*         SKEDULR CAN BE PERFORMED ONCE EVERY 3 HOURS INSTEAD OF ONCE 
*         AN HOUR (CURRENTLY, IF THE APR CALL SPECIFIES A RE-CALL OF
*         TIME OF MORE THAN 60 MINUTES, NO JOBS WILL BE SCHEDULED 
*         SINCE SKEDULR TREATS A PREVIOUS RUN OF MORE THAN AN HOUR
*         AGO AS TOO OLD, SO A NEW SEQUENCE IS STARTED).  THIS MODSET 
*         IS IN RESPONSE TO DPSR 033940 SUBMITTED BY S. BOUWMAN.
* 
* 
* SKEDULR JES   81/05/20
*         THIS MODSET CORRECTS A BUG IN SKEDULR THAT CAUSES JOBS THAT 
*         SHOULD BE SCHEDULED ON A SPECIFIC DAY OF THE WEEK TO ACTUALLY 
*         BE SCHEDULED ON THE WEEKEND.  THIS MODSET IS IN RESPONSE TO 
*         PSR 012078 (DIM0338) FROM ERIC LUIIJF.
* 
* 
* SKEDULR JES    81/05/20 
*         THIS MODSET CORRECTS THE PROGRAM DOCUMENTATION FOR THE NOSBE
*         SAMPLE JOB FOR EXECUTING SKEDULR.  TIMING PROBLEMS WITH THE 
*         APR CALLS FOR SOME SYSTEMS PREVENTS THE JOB FROM BEING
*         RESCHEDULED BY APR.  CHANGES ARE ALSO MADE TO CLEAN UP
*         JOB TERMINATION BY RELEASING PERMANENT FILES IN NOSBE TO
*         PREVENT TIMING PROBLEMS BETWEEN END OF JOB PROCESSING AND 
*         PERMANENT FILE PROCESSING ROUTINES.  THIS MODSET IS IN
*         RESPONSE TO PSR 012074 (DIM0339) FROM ERIC LUIIJF.
* 
* 
* SKEDULR JES    81/07/13 
*         THIS MODSET CORRECTS SKEDULING PROBLEMS IN NOSBE CREATED BY 
*         CLOCK WRAP-AROUNDS AT MIDNIGHT.  IT IS CURRENTLY POSSIBLE TO
*         MISS A SCHEDULING OR CAUSE THE SCHEDULE TO OCCUR ON THE SECOND
*         RUN PAST MIDNIGHT.  THESE PROBLEMS WERE REPORTED ON DPSR
*         033941 AND 033704 BY S. BOUWMAN.
* 
* 
* FMU       HNS 81/10/06
* 
*         FMU LONG CONTROLWARE MODS.
*         1. MODIFY FMU21 TO LOAD BOTH LENGTHS OF CONTROLWARE.
*         2. MODIFY FMU61 TO LOAD BOTH LENGTHS OF CONTROLWARE.
*         DPSR 033600 
* 
* 
* MALET   JMO    82/01/19 
*         MODSET CORRECTS MALET SO THE DEVICE CODE IS NOT CLEARED 
*         WHEN INTERRUPTING AT THE GO/DROP PAUSE. DPSR 34700. 
* 
* 
* MALET11 JMO    82/01/19 
*         MODSET CORRECTS MALET SO THE DEVICE CODE IS NOT CLEARED 
*         WHEN INTERRUPTING AT THE GO/DROP PAUSE. DPSR 34700. 
* 
* 
* HPA3    PWL  82/01/20 
*         MODSET HPA035523 CORRECTS THE PROBLEM OF MULTIPLE 
*         USAGE ENTRIES IN SHR BY ASSIGNING AN ERROR CODE 
*         OF 7777B TO USAGE RECORDS.
* 
* 
* HPA2    RAS  81/01/12 
* HPA21   MODSET HPA032624 SPLITS THE HPA SORT OVERLAY (2) INTO 
* HPA22   PRIMARY AND SECONDARY OVERLAYS.  THE RESULT IS: 
*         1- THE EXECUTION FIELD LENGTH REQUIREMENTS FOR HPA
*         ARE REDUCED BY APPROXIMATELY 11.2K OCTAL. 
*         2- FUTURE ADDITIONS OF DETAIL STATUS ANALYSIS FOR NEW 
*         DEVICES WILL HAVE LITTLE OR NO IMPACT ON THE EXECUTION
*         FIELD LENGTH REQUIREMENTS OF HPA. 
* 
*         THIS MODSET ALSO PLACES THE TABLES CVDT, DLT, AND SCT IN
*         SUBROUTINE *DSA* UNDER THE CONTROL OF A *CTEXT* PSEUDO, 
*         THEREBY REDUCING THE SIZE OF THE HPA PROGRAM LISTING BY 
*         8-131 PAGES.  THE *CTEXT* PSEUDO HAS NO IMPACT ON HPA 
*         EXECUTION.
* 
* 
*         DPSR 033160 
*  HPA    REF 01/20/82
*         MODSET HPA033160 EDITS SELECTED SEF DATA WHEN HPSORT IS USER- 
*         DEFINED.  SPECIFICALLY, IT CHECKS THE RECORD TYPE, DEVICE TYPE
*         AND THE DATE FOR VALIDITY.  ANY RECORDS WHICH CONTAIN UNQUALI-
*         FIED DATA ARE PRINTED AND DISCARDED, THUS ALERTING THE USER 
*         AND PROTECTING HPA REPORTS AND HISTORY FILE.
* 
* 
* NLM     MRL 81/08/18
* 
*         ADDITION OF REAL TIME CLOCK TO LOC. 40
*         1. MOVE DEVICE TYPE FROM 40 TO 44 
*         2. ADD REAL TIME CLOCK TO LOC. 40 
* 
* FLM     CJC   81/10/06
* 
*         ADDITION OF REAL TIME CLOCK TO LOCATION 40 OF LCN 
*         1. MOVE DEVICE TYPE FROM 40 TO 44 
* 
* 
* LCM     MRL 81/08/24
* 
*         ADDITION OF REAL TIME CLOCK TO NAD LOC. 40
*         1. DELETE READS FROM LOC. 40 IN NAD 
*         2. INSERT DOCUMENTATION CHANGES 
* 
* D44     MSF    81/12/21 
*         MODSET CORRECTS D44 MODULE 35 TO DO A FORWORD 
*         OFFSET EARLY STROBE READ MARGIN IN PASS NUMBER
*         6. THIS MODSET ALSO CORRECTS MODULE 36 TO DO A
*         REVERSE OFFSET LATE STROBE IN PASS NUMBER 4 AND A 
*         FORWORD OFFSET EARLY STROBE IN PASS NUMBER 6. 
*         DPSR  042466. 
* 
* 
* D44     MSF    81/12/17 
*         MODSET CORRECTS D44 MODULE 10 TO CHECK GENERAL
*         STATUS AFTER DOING A SHORT READ AND IN CONDITION
*         3.  DPSR 034625.
* 
* 
* D44     MSF    81/12/10 
*         MODSET CORRECTS D44 EXTERNAL DOCUMENTATION TO CAUTION 
*         THE USER THAT DATA CAN BE DESTROYED ANYWHERE ON THE 
*         PACK WHEN THE DIAGNOSTIC IS RUNNING UNDER PARAMETER 
*         DRIVEN MODULES WITH AN ACCESS LEVEL OF 4.  DPSR 034635. 
* 
* 
* DTC     MSF    81/12/10 
*         MODSET CORRECTS DTC EXTERNAL DOCUMENTATION TO CAUTION 
*         THE USER THAT DATA CAN BE DESTROYED ANYWHERE ON THE 
*         PACK WHEN THE DIAGNOSTIC IS RUNNING UNDER PARAMETER 
*         DRIVEN MODULES WITH AN ACCESS LEVEL OF 4.  DPSR 034635. 
* 
* 
* FTP     MSF    82/01/12 
*         MODSET CORRECTS FTP MODULES 46A AND 47A TO PRINT
*         THE CORRECT CHARACTER CODES FOR THE FORMAT LEVEL
*         WHEN TRAIN TYPE 6.  DPSR 024040.
* 
* 
* FMU     JMO    82/01/06 
*         MODSET CORRECTS THE FMU PL SO THE ENDIF STATEMENTS
*         DO NOT HAVE EXTRA LINES. DPSR 035004. 
* 
* 
* D44     JMO    82/01/04 
*         MODSET CORRECTS D44 MODULES 01 AND 02 SO
*         D44 AND D88 CAN BE RUN ON 2 ACCESSES AT 
*         THE SAME TIME UNDER DEMOT. DPSR 033454. 
* 
* 
* LCN     AKJ  81/12/07 
*         LCN MODULES LCN05 AND LCN12 
*         FAILS DUE TO CHANGE IN THE A03
*         LCN COMMON CONTROLWARE. 
* 
* 
* TFF     JMO    82/01/26 
*         MODSET CORRECTS MODULE 10 OF TFF SO IT WILL RUN 
*         WHEN THE TEST SEQUENCE IS EXECUTED. DPSR 034698.
* 
* 
* MALET11 JMO    82/01/27 
*         MODSET CORRECTS MALET11 SO THE PUNCH FILE WILL BE 
*         OUTPUTED ONLY ON A PUNCH DIRECTIVE ON NOS 6. DPSR 
*         034699. 
* 
* 
* MALET30 JMO    82/01/27 
*         MODSET CORRECTS MALET30 SO THE PUNCH FILE WILL BE 
*         OUTPUTED ONLY ON A PUNCH DIRECTIVE ON NOS 6. DPSR 
*         034699. 
* 
* 
* MALET10 JMO    82/01/29 
*         MODSET CORRECTS MALET SO AN EXTRA OPERATOR GO IS
*         NOT NECESSARY ON NOS R4. DPSR 034692. 
* 
* 
* FLM     JMO    82/01/19 
*         MODSET CORRECTS ALL THE PAUSES IN FLM SO A MESSAGE
*         WILL BE DISPLAYED AND PRINTED AT THE TIME OF THE
*         PAUSE. DPSR 033439. 
* 
* 
* FLM     JMO    82/01/18 
*         MODSET CORRECTS MODULE 02B SO 2 PAUSES DO NOT OCCUR 
*         ON 1 ERROR. DPSR 033437.
* 
* 
* MALET   JMO    82/01/20 
*         MODSET ADDS THE CALL VERS TO ALL OF THE MALET 
*         OVERLAYS SO THE BUILD LEVEL WILL APPEAR ON THE
*         DEADSTART BINARY. DPSR 035006.
* 
* 
* F44     JMO    82/01/07 
*         MODSET CORRECTS F44 MODULE 16 SO IT DOES NOT ERROR ON 
*         TRACK FLAWS. DPSR 035001. 
* 
* 
* INSTLDKS  PWL  82/02/04 
*           MODSET INS035010 ADDS "*COMPILE,HPA21" AND
*           "*COMPILE,HPA22" TO INSTALL DECKS.
* 
* 
* FLM     MSF    82/01/18 
*         MODSET CORRECTS FLM MODULE 01 TO RERESERVE THE CHANNEL
*         AFTER THE ERROR PROCESSOR HAS STOPPED THE PPU.
*         DPSR  033436. 
* 
* 
* SKEDULR JES    81/05/20 
*         THIS MODSET PROVIDES A NOSBE CAPABILITY TO DEFINE THE ORDER 
*         OF DAY, MONTH AND YEAR AS ENTERED BY THE OPERATOR AT DEAD-
*         START TIME.  CURRENTLY, IF THE ORDER IS NOT MONTH, DAY, YEAR
*         (MDY), SKEDULR WILL NOT SCHEDULE JOBS PROPERLY.  THIS DATA
*         IS OBTAINED FROM NOSBE IPTEXT, THEREFORE THE INSTALLATION 
*         OF SKEDULR INTO A NOSBE SYSTEM WILL NOW REQUIRE  S=IPTEXT 
*         ON THE COMPASS CARD (SEE INSTALLATION EXAMPLE IN THE CODE). 
*         THIS MODSET IS IN RESPONSE TO PSR 012076 (DIM0337) FROM 
*         ERIC LUIIJF.
* 
* 
* SKEDULR JES    81/05/20 
*         THIS MODSET CORRECTS A BUG IN SKEDULR THAT OCCURS WHEN A
*         LARGE JOB IS SCHEDULED UNDER NOSBE.  THE JOB DECK SUBMITTED 
*         TO THE INPUT FILE IS SHUFFLED SINCE THE SAME BUFFER IS USED 
*         BY SKEDULR TO PERFORM READS AND WRITES ON TWO DIFFERENT 
*         FILES.  IT ALSO CORRECTS PROBLEMS CREATED BY USING CMICRO 
*         INSTEAD OF MICRO STATEMENTS IN NOSBE.  THIS MODSET IS IN
*         RESPONSE TO PSR 012079 (DIMA0341) FROM ERIC LUIIJF. 
* 
* 
* SKEDULR JMO    82/02/111
*         MODSET CORRECTS SKEDULR SO IT DOES NOT GIVE DAYFILE MESSAGE 
*         SETQP MACRO NOT SUPPORTED ON NOS R6. DPSR 034691. 
* 
* 
*         DPSR 033158 
* HPA     02/08/82
* HPA39   MODSET HPA03158 ADDS CODE TO HPA39 TO PROCESS LCN NOS/BE
*         ERROR MESSAGES (RTY 76B).  IN ADDITION, THE MODSET ENHANCES 
*         OR CORRECTS LCN PROCESSING AS FOLLOWS:  
*         1) GENERATES LCN ANALYSIS REPORTS FOR NOS AND NOS/BE ERRORS;
*         2) ALLOWS USER TO SELECT LCN REPORTS WITH HPA PARAMETERS: 
*         DETAIL, STATUS AND/OR STATISTICS; 
*         3) CORRECTS THE SOURCE, MAINFRAME ID AND TYPE 3 BUFFER SIZE 
*         FIELDS IN THE LCN STATISTICS REPORT;
*         4) SUPPLIES THE LCN ERROR MESSAGES FOR THE SUMMARY AND SHR
*         REPORTS;
*         5) RESTORES THE EST FIELD FOR THE SUMMARY AND SHR REPORTS;
*         6) REMOVES THE DATE FIELD FROM THE LCN HEADERS AND INSERTS
*         THE DATE ON THE DETAIL LINE - TO REFLECT DATE CHANGES.
* 
* 
* HISTORY TRR   82/02/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L137*. 
* 
* 
* 
* 
* SKEDULR DAT    82/02/18 
*         THIS MODSET CORRECTS A MODSET TRANSMITTAL ERROR 
*         IN MODSET DIM0341 
* 
* 
* FMD     MSF    82/02/02 
*         MODSET CORRECTS FMD MODULE 96T TO ADD THE DECK BOARDS 
*         TO THE EXISTING LIST OF BOARDS TO BE REPLACED WHEN A
*         0A020 FAILURE OCCURS.   DPSR 027332.
* 
* 
* NLM     MSF    82/01/25 
*         MODSET CORRECTS NLM MODULE 01A TO DISPLAY THE CORRECT 
*         ERROR AND NOT ALLOW A FALSE SECOND ERROR OF BUFFER INDEX
*         OR WC ERR.  DPSR 033279.
* 
* 
* HPA38   PWL  82/01/26 
*         MODSET HPA034643 ADDS CODE TO CONTROL REPEATED LINES
*         OF MR DETAIL REPORT AND TO ELIMINATE UN-CALLED FOR MR 
*         ANALYSIS REPORT HEADER. 
* 
* 
* CR1     JMO    82/02/17 
*         MODSET CORRECTS CR1 SO IT WILL DETECT THE HARDWARE ERROR OF 
*         THE CHANNEL NOT GOING DEACTIVE ON AN END OF RECORD READ 
*         FUNCTION THE SAME AS KEDIAGS CR1 AND SMM CR1. DPSR 043698.
* 
* 
* HPA5    SLS  82/02/17 
* 
*        MODSET HPA016369 CORRECTS THE PROBLEM OF THE HUID GETS 
*        PRINTED AS **** IN S=3 REPORTS.
* 
* 
* HPA5    SLS  82/02/17 
* 
*        MODSET HPA016367  CORRECTS THE PROBLEM OF INCORRECT HUID 
*        IN THE HISTORY GRAPH REPORT. 
* 
* 
* HPA2    SLS  82/02/17 
* 
*        MODSET HPA016368 CORRECTS THE PROBLEM OF NO MATCH IS MADE
*        IF UNIT NUMBER IS 40 OR GREATER AND CONSEQUENTLY NO HUID 
*        IS RETURNED. 
* 
* 
*         DPSR 034636 
* HPA5    82/02/19 REF
*         MODSET HPA034636 CORRECTS THE DATES PRINTED IN THE
*         "DATE OCCURRED" PORTION OF THE SUMMARY REPORT WHEN
*         THE ERROR LOG MESSAGES SPAN A YEAR BOUNDARY.
* 
* 
*         DPSR 033159 
* HPA     REF 02/19/82
*         MODSET HPA033159 ADOPTS A UNIFORM DATE FORMAT THROUGHOUT HPA
*         REPORTS AS FOLLOWS: YY/MM/DD.  THE INCONSISTENT DATE PROBLEM
*         WAS IDENTIFIED BY PSR DIMA394.
* 
* 
* FTP     82/02/22
*         MODSET CORRECTS FTP98B SO THE CHARACTER A IS NOT
*         MISSING IN THE RIPPLE PATTERN GENERATION FOR A
*         TYPE 6 TRAIN. DPSR 042463.
* 
* 
* MALET   JMO    82/03/01 
*         MODSET CORRECTS THE PROBLEM OF HANGING MLD IN A PP
*         WITH A TERMINAL INTERRUPT IF RC IS ON WITH NOS R6.
*         DPSR 034603.
* 
* 
* MALET12 JMO    82/03/01 
*         MODSET CORRECTS THE PROBLEM OF HANGING MLD IN A PP
*         WITH A TERMINAL INTERRUPT IF RC IS ON WITH NOS R6.
*         DPSR 034603.
* 
* 
* HISTORY TRR   82/03/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L138*. 
* 
* 
* 
* 
* F7X     MSF    82/03/11 
*         MODSET CORRECTS F7X MODULE 03 TO DO A REWIND MOTION 
*         FUNCTION TO CLEAR THE RESET KEY DEPRESSED STATUS LATCH
*         IN THE TAPE DRIVE PRIOR TO THE CHECKING OF UNIT STATUS. 
*         DPSR  008064. 
* 
* 
* HPA21   SLS  82/03/10 
* 
*        MODSET HPA033598 CORRECTS THE PROBLEM OF A STATEMENT 
*        LABEL ON AN END STATEMENT. 
* 
* 
* MALET   JMO    82/03/08 
*         MODSET REMOVES THE MALET DOCUMENTATION THAT IS LISTED 
*         WITH THE *DEFINE,DOC WHEN ASSEMBLING MALET. THIS INFO 
*         IS THE SAME AS THE CML REFERENCE MANUAL. DPSR 027333. 
* 
* 
* HPA1    PWL  82/02/03 
*         MODSET HPA034647 CHANGES "PROGRAM ABORT" AND "ABORT"
*         MESSAGES TO "HPA RUN ABORT" IN ORDER TO AVOID THE 
*         CONFUSION WITH OPERATING SYSTEM ABORT.
* 
* 
* F44     JMO    82/03/05 
*         MODSET CORRECTS F44 MODULE 16 SO ONE ERROR WILL NOT 
*         CAUSE THE MODULE TO EXIT. DPSR 034627.
* 
* 
* F88     JMO    82/03/05 
*         MODSET CORRECTS F88 MODULE 16 SO ONE ERROR WILL NOT 
*         CAUSE THE MODULE TO EXIT. DPSR 034627.
* 
* 
* HPA36   SLS  82/02/25 
* 
*        MODSET HPA032625 CORRECTS THE PROBLEM OF REPORTING A 
*        FAILING BIT WHEN HPA DETECTS A DOUBLE BIT ERROR ON 
*        CY170 MACHINE. 
* 
* 
* F44     JMO    82/03/17 
*         MODSET CORRECTS MODULE 20 SO IF STOP ON ERROR 
*         IS CLEARED WHILE RUNNING SURFACE ANALYSIS THE 
*         MODULE WILL NOT  EXIT AFTER  10 ERRORS.  DPSR 
*         023622. 
* 
* 
* F88     JMO    82/03/17 
*         MODSET CORRECTS MODULE 20 SO IF STOP ON ERROR 
*         IS CLEARED WHILE RUNNING SURFACE ANALYSIS THE 
*         MODULE WILL NOT  EXIT AFTER  10 ERRORS.  DPSR 
*         023622. 
* 
* 
* LCN     MSF    82/03/08 
*         MODSET CORRECTS LCN MODULES 08, 10, AND 11 TO REPORT
*         A CONTROLWARE STATUS ERROR OF 17B (TRANSFER NOT READY)
*         ONLY AFTER A 10D ERROR LIMIT.   DPSR 033589.
* 
* 
* HPA36    SLS  82/02/25
* 
*        MODSET HPA027334 CORRECTS THE PROBLEM OF AN EXTRA BLANK
*        LINE IN THE SCR DETAIL REPORT, ADDS THE MMF ID TO THE
*        SCR ANALYSIS REPORT, AND ADDS THE ROW SELECT AND CHIP
*        THE SCR ANALYSIS AND DETAIL REPORTS. 
* 
* 
* COMHPAERT   PWL  82/03/10 
* HPS35       MODSET HPA032632 ADDS CE ERROR CODES TO 2550 MESSAGES,
*             CREATES A MATRIX OF CE ERRORS VS. PORT NUMBERS, AND 
*             CHANGES GRAPHS AND STATISTICS SUMMARY REPORTS TO BE 
*             CONTROLLED BY ST AND A PARAMETER AND DETAIL STATISTICS
*             REPORTS TO BE CONTROLLED BY ST AND D PARAMETER. 
* 
* 
* HPA36   SLS  82/03/11 
* 
*        MODSET HPA032623 CORRECTS PROBLEM OF SINGLE SECDED 
*        ERRORS NOT INCLUDED IN SR UNIT ANALYSIS REPORT.
* 
* 
*         DPSR 035014 
* HPA39   03/15/82
*         MODSET HPA035014 CORRECTS LCN/HPA REPORT IRREGULARITIES.
* 
* 
* MALET11 JMO    82/03/18 
*         MODSET CORRECTS THE PROBLEM OF GETTING INVALID
*         ACCESS LEVEL IF ASSIGNING RMS DEVICE WITH AN
*         AL OF 10. DPSR 034646.
* 
* 
* SKED    JMO    82/03/24 
*         MODSET CORRECTS SKEDULR SO CHANGING TFPFN OR PFILEID
*         CAN BE ACCOMPLISHED ON NOSBE WITOUT ASSEMBLY ERRORS.
*         DPSR 035045.
* 
* 
* HISTORY LJC   82/04/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L139*. 
* 
* 
* 
* 
* ATC     JMO    82/04/19 
*         MODSET CORRECTS ATC MODULE 52 SO IT DOES NOT FAIL 
*         WHEN RUN AFTER MODULE 51 ON DEMOT. DPSR 007059. 
* 
* 
* HPA21   SLS  82/04/13 
* 
*        MODSET HPA039591 CHANGES HPA SO IT OPTIONALLY
*        PRINTS (USING DX) SY MESSAGES OTHER THAN DEADSTART 
*        AND CYBERLOG.
* 
* 
* MALET   JMO    82/04/05 
*         MODSET UPDATES THE VERSION NUMBER TO 2 FOR THE CHANGES
*         THAT OCCURRED IN LEVEL 126 BUT WERE NEVER UPDATED IN
*         THE 66X AND 844HT PRODUCT OVERLAYS. DPSR 035579.
* 
* 
* SKEDULR JMO    82/04/15 
*         MODSET CORRECTS ASSEMBLY ERRORS OF SKEDULR ON NOSBE 
*         CAUSED BY MODSET SKED35045. DPSR 033141.
* 
* 
* HPA7    SLS  82/04/15 
* 
*        MODSET HPA033945 CORRECTS PROBLEM OF INCORRECT UNIT NUMBERS
*        IN THE SHR AFTER THE TRANSMIT FLAG IS SET. 
* 
* 
* DTC     MSF    82/03/31 
*         MODSET CORRECTS DTC MODULES 08 AND 11 TO RERESERVE
*         THE DISK DRIVE BEFORE THE NEXT SEEK TO A NEW CYLINDER 
*         IS ISSUED.  DPSR 039655.
* 
* 
* HPA8    SLS  82/04/01 
* 
*        MODSET HPA034747 CORRECTS THE PROBLEM OF CHANGES MADE
*        TO CYBERLOG ENTRIES WHICH WERE PREVIOUSLY CHANGED
*        ARE NOT SAVED. 
* 
* 
* COMHPAERT  PWL  82/03/25
*            MODSET HPA039589 COMBINES SYSTEM MESSAGES "POWER 
*            FAILURE" AND "POWER DOWN" INTO ONE ERROR MESSAGE 
*            "POWER FAILURE/DOWN" (327B). 
* 
* 
* HPA2    SLS  82/04/05 
* 
*        MODSET HPA035528 ADDS DATE / TIME AND LINE LIMIT CAPABILITY
*        TO THE INTERVENTION REPORT.
* 
* 
* SKEDULR JMO    82/04/16 
*         MODSET CORRECTS THE PROBLEM OF A SYNTAX ERROR ON
*         THE JOBS FILE AND AFTER CORRECTING THE SYNTAX TO
*         CONTINUE TO ROUTE THE EMPTY OUTPUT FILE EACH TIME 
*         SKEDULR IS ROLLED IN. DPSR 040505.
* 
* 
* HPA32   SLS  82/04/02 
* 
*        MODSET HPA033128 CORRECTS TYPING ERROR OF ERROR MESSAGE -
*        SCHEDULED MAINTENANCE. 
* 
* 
* HISTORY PMW   82/05/03
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L140*. 
* 
* 
* 
* 
* MALET   JMO    82/04/28 
*         MODSET CORRECTS MALET SO THE CROSS REFERENCE MAP IS NOT 
*         RETURNED TO A TERMINAL BUT TO THE ALTERNATE FILE AS THE 
*         LISTING IS WHEN THE MAP OPTION IS USED. DPSR 033597.
* 
* 
* MALET40 JMO    82/04/28 
*         MODSET CORRECTS MALET SO THE CROSS REFERENCE MAP IS NOT 
*         RETURNED TO A TERMINAL BUT TO THE ALTERNATE FILE AS THE 
*         LISTING IS WHEN THE MAP OPTION IS USED. DPSR 033597.
* 
* 
*         DPSR 037779 
* HPA21   05/03/82
*         MODSET HPA037779 ENABLES THE TAPE INTERVENTION REPORT TO
*         APPEAR CONCURRENTLY WITH THE SELECTION OF DETAILED STATUS 
*         ANALYSIS (DSA). 
* 
* 
*         DPSR O37781 
* HPA22   05/03/82
*         MODSET HPA037781 ENABLES DETAILED STATUS ANALYSIS (DSA) TO
*         PROCESS 67X/ATS RECORDS FROM NORM THAT CONTAIN AN UNDETERMINED
*         ERROR CODE (IE, ERROR CODE = 0).
* 
* 
*         DPSR HPA037780
* HPA     REF 04/29/82
*         MODSET HPA037780 ADDS THE 66X/MTS GENERAL STATUS WORD II
*         TO THE 80 AND 132 COLUMN TAPE DETAIL REPORTS.  ADDITIONALLY:  
* 
*         1) MODSET REMOVES CODE PREVIOUSLY INSERTED IN SETFLDS (IDENT
*         HPA403REF) TO COMPENSATE FOR MIS-ALIGNED TAPE SEF FIELDS FROM 
*         NORMS (NOS/BE).  NORMS WAS CORRECTED WITH IDENT DIM0371;
* 
*         2) MODSET ADDS AN ASTERISK TO THE DENSITY FIELD OF 67X DETAIL 
*         REPORTS TO DENOTE "ERROR CORRECTION DISABLED" CONDITION;
* 
*         3) MODSET ELIMINATES TRIPLICATE LABELING OF HPA33 TAPE FIELDS,
*         REMOVING IFLD ARRAY EQUVALENTS: FDS ARRAY AND FTX VARIABLES.
* 
*         THE GENERAL STATUS WORD II WAS PREVIOUSLY AVAILABLE BUT UNUSED
*         IN NORM-GENERATED SEFS; IT WAS MADE AVAILABLE IN NORMS-GENER- 
*         ATED SEFS WITH IDENT DIM0371. 
* 
* 
* HPA5    SLS  82/05/03 
* 
*        MODSET HPA034641 PRINTS REVISION NUMBER FOR FIRMWARE 
*        REVISION MESSAGE ENTRY IN DECIMAL INSTEAD OF OCTAL.
* 
* 
* HPA,HPA35   PWL  04/27/82 
* COMHPAERT   MODSET HPA033135 REPORTS CCP LINE, TRUNK, AND NPU 
* HPA3        STATISTICS FOR MULTI-HOST.
* 
* 
* HPA35   PWL  82/05/04 
*         MODSET HPA46713 STOPS THE PRINTING OF EMPTY PORT
*         ACTIVITY GRAPH AND STATISTICS SUMMARY HEADINGS
*         WHEN THERE IS NO INPUT. 
* 
* 
* FMD     JMO    82/05/04 
*         MODSET CORRECTS FMD MODULE 29 SO ADDRESS SWITCHES 
*         REFLECT A/B20 BOARDS INSTEAD OF JUST THE A20
*         BOARD. DPSR 050813. 
* 
* 
* FMD     JMO    82/05/04 
*         MODSET CHANGES THE ERROR MESSAGE IN FMD MODULE 97M
*         TO SET SYS MAINT BEFORE REPLACING ANY BOARDS. DPSR
*         050809. 
* 
* 
* D44     JMO    82/05/13 
*         MODSET CORRECTS MODULE 48 SO A RUNNING MESSAGE IS 
*         POSTED AND THE ERROR PROCESSOR IS CALLED FOR ALL
*         RESERVE ABORTS. DPSR 035897.
* 
* 
* FMD     JMO    82/05/05 
*         MODSET CORRECTS FMD MODULE 96S FOR ERROR MESSAGE 0A025
*         TO INCLUDE ADDRESS FIELD DATA BAD. DPSR 050802. 
* 
* 
* HPERS   SLS  82/05/24 
* HPA 
* HPA3
* HPA36 
* 
*        MODSET HPA050698 ADDS ESM DETAIL AND ANALYSIS REPORTS
*        TO HPA.
* 
* 
* MALET   JMO    82/02/01 
*         MODSET ADDS SYSREAD SYSWRITE AND SYSREWIND ESM TO MALET.
*         DPSR 035012.
* 
* 
* MALET11 JMO    82/02/01 
*         MODSET ADDS SYSREAD SYSWRITE AND SYSREWIND ESM TO MALET.
*         DPSR 035012.
* 
* 
* MALET12 JMO    82/02/01 
*         MODSET ADDS SYSREAD SYSWRITE AND SYSREWIND ESM TO MALET.
*         DPSR 035012.
* 
* 
* HPA7    PWL  82/05/27 
*         MODSET HPA33138 PRINTS "OPTIME NOT ENTERED" FOR AVAIL-
*         ABILITY IN THE SITE MANAGEMENT ANALYSIS REPORT WHEN 
*         OPTIME IS ZERO, AND "--" WHEN DOWN TIME EXCEEDS OPTIME. 
* 
* 
* HISTORY DJU   82/06/14
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L141*. 
* 
* 
* 
* 
* HPA4    SLS  82/06/09 
* 
*        MODSET HPA020015 MAKES SURE MMF AND CY ARE PLACED ON DUMMY 
*        50 AND 51 RECORDS. 
* 
* 
* ATC     JMO    82/06/14 
*         MODSET CORRECTS ATC MODULE 00 SO THE CONNECT FAILURE
*         MESSAGE IS NOT MISLEADING. DPSR 040518. 
* 
* 
*         DPSR 016701 
* HPA     REF  06/14/82 
*         MODSET HPA016701 RESPONDS TO THE IDENTIFICATION OF NOS R-6
*         1MT ERROR CODE CHANGES.  WHEN IMPLEMENTING THESE CHANGES IN 
*         NORM UNDER PSR DIMA777, AN INCORRECT ERROR CODE CONVERSION
*         WAS DETECTED.  MODSET HPA016701 ADDS AN ERROR CODE TO HPA TO
*         ENABLE THE CORRECT CONVERSION.  SPECIFICALLY, HPA ERROR CODE
*         37-NON-FATAL-USER-ERROR IS ADDED TO REFLECT NOS 1MT ERROR 
*         CODE 21-MFM-MULTI-FILE-NOT-FOUND.  IT IS CLASSIFIED AS A
*         COMMON ERROR, ACCESSIBLE TO ALL DEVICE TYPES. 
* 
* 
*         DPSR 033947 
* HPA22   RAS    82/06/04 
*         MODSET HPA033947 REPLACES THE 844 DETAIL STATUS 
*         ANALYSIS TABLES IN HPA.  THE MODSET CORRECTS TWO
*         PROBLEMS- 
* 
*         1. ISSUES TRACK FLAW OR SECTOR FLAW MESSAGES
*         IF A FLAWED SECTOR IS PROCESSED AND 
*         DETAIL STATUS ALSO INDICATES AN ADDRESS 
*         COMPARE ERROR (DPSR 033947) 
* 
*         2. CORRECTS A PROBLEM IN THE FLOW WHICH RESULTED
*         IN 2 ERROR MESSAGES NEVER BEING PRODUCED. 
*         (SC302-DSU P.S. TEMP ABNORMAL, SC303-DSU LOGIC
*         TEMP ABNORMAL) (DPSR 047826)
* 
*         NOTE - THE MODSET CHANGES THE HPA ERROR CODES ASSIGNED TO 
*         THE SPECIFIC MESSAGES.  844 REPORTS PRODUCED FROM 
*         HISTORY FILE DATA MUST BE GENERATED WITH THE
*         -DSA=ALL- PARAMETER INCLUDED ON THE HPA CONTROL 
*         STATEMENT AFTER THIS MODSET IS INSTALLED. 
*         OTHERWISE, ERRONEOUS REPORTS WILL BE PRODUCED.
*         ONCE ALL HISTORY FILE DATA WHICH HAD ERROR CODES
*         ASSIGNED BY A PREVIOUS VERSION OF HPA HAS BEEN
*         DROPPED, THE -DSA=ALL- PARAMETER IS NO LONGER 
*         REQUIRED.  IT MAY ALSO BE NECESSARY TO EDIT OLD 
*         ENTRIES FROM THE SHR RECORD.
* 
* 
* TFE     RJN    02/24/82 
*                MODSET ADDS 2400,4800, AND 9600 BAUD ASYNC 
*                SUPPORT TO DIAGNOSTIC TFE. PARAMETER REGISTER
*                P2 MUST BE SET TO 2402,4002 OR 6002 TO ENABLE
*                TESTING AT THESE SPEEDS.  THE CORRESPONDING
*                MODSET MUST BE INSTALLED IN MLD ON REL2B OR PL5
*                WHICH ALLOWS THE ABOVE PARAMETERS TO BE LEGAL. 
* 
* 
* T6X     JES    82/05/19 
*         THIS MODSET CORRECTS A PROBLEM IN THE COMPATIBILITY TEST, 
*         T6X80 AND T6X80A, CREATED BY CHANGES TO MLD WHICH USES
*         THE OUTPUT BUFFER AS A SLUSH BUFFER ON READS.  T6X80 USED 
*         WORD 477 OF OB TO SAVE AN INDEX FOR T6X80A WHICH GETS 
*         DESTROYED.  THIS CAUSES A BUFFER INDEX ERROR IN T6X80A ON 
*         7TK UNITS AND INVALID ERROR INFORMATION DISPLAYED FOR 9TK 
*         UNITS (IF T6X80A DETECTS AN ERROR). DPSR 038260.
* 
* 
* FMC       HNS 82/06/30
* 
*         REMOVE TSP CODE FROM FMC. 
*         DPSR 037799 
* 
* 
* MALETP2 JMO    82/06/30 
*         MODSET CORRECTS THE 580 LANGUAGE COMPILER SO A SELECT 
*         PREPRINT OR POSTPRINT WITHOUT THE Y PARAMETER WILL
*         GENERATE A SYNTAX ERROR. DPSR 050652. 
* 
* 
*         DPSR 037782 
* HPA2    REF  06/24/82 
* HPA21   MODSET HPA037782 ENABLES THE BYPASSING OF AN HUID.
* HPA22   THIS GOAL WAS ACCOMPLISHED BY RESTRUCTURING THE HPA2 OVERLAY
* HPA23   AS FOLLOWS: 
*         1) EDITING, HUID AND BYPASSING OPERATIONS HAVE BEEN MODULAR-
*         IZED AND PLACED ON THE PRIMARY OVERLAY LEVEL (2,0).  THEY ARE 
*         THUS ACCESSIBLE FROM THE HPA21-SORT/MERGE, HPA21-HPSORT AND 
*         HPA22-DSA SUB-OVERLAYS; 
*         2) THE READING OF THE HARDWARE CONFIGURATION TABLE, IN RE-
*         SPONSE TO THE MMF PARAMETER, HAS BEEN PLACED IN HPA23, A
*         NEW SUB-OVERLAY;
*         3) HPSORT (THE IN-LINE SORTING TO SUPPLANT THE SORT/MERGE 
*         PACKAGE) DATA HANDLING HAS BEEN MADE IDENTICAL TO THE SORT/ 
*         MERGE CAPABILITIES, WITH THE ADDITION OF MMF (ADDING AN HUID) 
*         AND DSA (DETAILED STATUS ANALYSIS); 
*         4) DATA FLOW HAS BEEN STREAMLINED, INDEPENDENT OF PARAMETERS
*         AND *IF,DEFINES.  EDITING, HUID AND BYPASSING OPERATIONS ARE
*         DONE PRIOR TO DSA AND SORTING; INTERVENTION REPORTING IS DONE 
*         AFTER DSA BUT PRIOR TO SORTING; DATA COMPRESSION IS DONE AFTER
*         DSA AND SORTING HAVE OCCURRED.
* 
*         RESTRUCTURING HAS GAINED 1K OF CRUCIAL FIELD LENGTH IN THE
*         HPA21-SORT/MERGE OVERLAY. 
* 
*         FURTHERMORE, MODSET HPA037782 REFORMATS INTERVENTION REPORTS, 
*         PROVIDING FORMAT CONSISTENCY BETWEEN DIFFERENT MESSAGES, AND
*         INCLUDING CHANNEL, EQUIPMENT AND UNIT NUMBERS IN ALL MESSAGES.
* 
* 
* HISTORY DJU   82/07/09
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L142*. 
* 
* 
* 
* 
*         DPSR 050621 
* HPA8    REF  07/01/82 
*         MODSET HPA050621 ENABLES MSFS MEDIA REPORTS FROM A HISTORY
*         (NEW OR OLD) FILE.  PREVIOUS CODE WAS NON-OPERATIONAL: EACH 
*         ACCESS OF A HISTORY FILE WAS PREFACED WITH A SKIPFILE COMMAND.
* 
* 
* MALET   JMO    82/05/17 
*         MODSET ADDS REPRIEVE PROCESSING TO MALET. THIS ALLOWS 
*         TERMINAL INTERRUPTS TO WORK CORRECTLY. DPSR 035040. 
* 
* 
* MALET10 JMO    82/05/17 
*         MODSET ADDS REPRIEVE PROCESSING TO MALET. THIS ALLOWS 
*         TERMINAL INTERRUPTS TO WORK CORRECTLY. DPSR 035040. 
* 
* 
* MALET11 JMO    82/05/17 
*         MODSET ADDS REPRIEVE PROCESSING TO MALET. THIS ALLOWS 
*         TERMINAL INTERRUPTS TO WORK CORRECTLY. DPSR 035040. 
* 
* 
* MALET12 JMO    82/05/17 
*         MODSET ADDS REPRIEVE PROCESSING TO MALET. THIS ALLOWS 
*         TERMINAL INTERRUPTS TO WORK CORRECTLY. DPSR 035040. 
* 
* 
* MALET30 JMO    82/05/17 
*         MODSET ADDS REPRIEVE PROCESSING TO MALET. THIS ALLOWS 
*         TERMINAL INTERRUPTS TO WORK CORRECTLY. DPSR 035040. 
* 
* 
*         DPSR 050620 
* HPERS   REF  07/30/82 
* HPA2    MODSET HPA050620 ENABLES THE PROCESSING OF SEF MESSAGES 
* HPA3    CONTAINING CORRECTED TAPE ERRORS.  SPECIFICALLY, THREE
* HPA33   HARDWARE-CORRECTED ERRORS ARE PROCESSED, AS FOLLOWS:  
* HPA8    -GCR SINGLE-TRACK READ CORRECTION,  ERROR CODE 2450B; 
* HPA9    -GCR SINGLE-TRACK WRITE CORRECTION, ERROR CODE 2451B; 
*         -66X/67X LATE DATA ERROR,           ERROR CODE 2452B. 
* 
* 
* COMHPAERT  PWL  82/07/15
* HPA,HPA1   MODSET HPA50633 GENERATES DETAIL AND ANALYSIS REPORTS
* HPA3,34    FOR DEMA.
* 
* 
* INSTLDKS JMO    82/07/28
*         MODSET ADDS COMPILE DECKS OF MALET2F MALET2G AND
*         MALET2H TO THE CML INSTALL DECKS. DPSR 050671.
* 
* 
* ATC     JMO    82/06/24 
*         MODSET CORRECTS ERRORS IN MODULES 36 AND 37 WHEN
*         RUNNING ON DOUBLE RANKED CHANNELS ON A 6000 OR
*         CYBER 70 WITH PATTERNS 2,5 AND 7. DPSR 050617.
* 
* 
* HISTORY LJC   82/08/09
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L143*. 
* 
* 
* 
* 
*         DPSR  HPA054338 
* HPA9    REF   08/12/82
*         MODSET HPA054338 SUPPLIES A CORRECTION TO MEDIA REPORTS FOR 
*         CORRECTED TAPE ERRORS.
* 
* 
*         PSR  DIM0448
* HPERS   REF  08/09/82 
* HPA1    MODSET DIM0448 EMBELLISHES THE HISTORY WINDOW PARAMETER 
*         DOCUMENTATION IN THE HPERS.  IT EXPLAINS THAT THE SPECIFIED 
*         NUMBER OF DAYS FOR THE HISTORY WNDOW ARE COUNTED BACKWARDS
*         IN TIME FROM THE REQUESTED BEGINNING DATE.
*         -----EXAMPLE: HW=820809/3 TRANSLATES TO HW=820809/820807. 
* 
*         MODSET ALSO PROVIDES 1 AS THE DEFAULT NUMBER OF DAYS, RATHER
*         THAN ALLOWING HPA TO ABORT WITH AN ERROR MESSAGE. 
*         -----EXAMPLE: HW=820809 TRANSLATES TO HW=820809/1.
*         -----EXAMPLE: HW TRANSLATES TO HW=CURRENT SYSTEM DATE/1.
* 
* 
*         PSR  DIM0446
* HPERS   REF  08/06/82 
* HPA1    MODSET DIM0446 CORRECTS THE HISTORY WINDOW PARAMETER TO 
*         COMPLY WITH THE STANDARD NOS SYSTEM DATE FORMAT OF YYMMDD.
*         IT REPLACES THE FORMAT OF MMDDYY. 
* 
* 
* NLM   GJH 82/3/12 
*       CLARIFY DOCUMENTATION PARAMETER P8
*       ALSO 99 MODULES NDM99, NDP99 AND NDT99
* 
* 
* HPA36   PWL  82/08/20 
*         MODSET HPA42779 REMOVES THE CHECKING OF ALPHA CHARATERS 
*         FOR MFID IN SCR DETAIL REPORTS TO ALLOW THE USE OF
*         NUMERIC CHARACTERS. 
* 
* 
*         DPSR  HPA042808 
* HPA33   REF   08/23/82
*         MODSET HPA042808 INSERTS A CUSTOMER-REQUESTED BLANK LINE IN 
*         THE TAPE ANALYSIS REPORT, FOR GREATER CLARITY.
* 
* 
*         DPSR  HPA042810 
* HPA34   REF   08/19/82
*         MODSET HPA042810 CORRECTS THE DISK DETAIL REPORT PROBLEM OF 
*         EVOKING A NEW PAGE WITH MISSING SUBHEADERS WHEN A DATE OR 
*         MESSAGE CHANGE FOR THE SAME DEVICE OCCURS MID-PAGE, BEFORE
*         THE CURRENT PAGE IS FILLED. 
* 
* 
*         DPSR  HPA042780 
* HPA5    REF   08/23/82
*         MODSET HPA042780 ENABLES THE HUID CHARACTER FLAG TO BE
*         PRINTED ASIDE THE HUID IN THE SYSTEM PERFORMANCE SUMMARY
*         REPORT AND GRAPH.  IT COMPLETES THE EFFORTS INITIATED UNDER 
*         MODSETS HPA016367 AND HPA016369.
* 
* 
*         PSR  DIM0447
* HPA33   REF  08/02/82 
*         MODSET DIM0447 CORRECTS THE PAGE LINE COUNT FOR HPA TAPE
*         DETAIL REPORTS.  IT PREVENTS A STAND-ALONE PAGE SUB-HEADER
*         FROM APPEARING AT THE BOTTOM OF A PAGE (IE. UN-FOLLOWED BY
*         DATA).  HPA DEFAULTS TO A PAGE LINE LIMIT OF 56.
* 
* 
* ATC      FBV    08/18/82
*          THIS MODSET PLACES MODULE 28 OF ATC
*          OUT OF THE ON-LINE TESTS SINCE IT
*          CAUSES CHANNEL PARITY ERRORS. DPSR 50701.
* 
* 
*         DPSR HPA054339
* HPA22   RAS  82/08/04 
*         MODSET HPA054339 ADDS THE DETAIL STATUS ANALYSIS FEATURE FOR
*         885-4X/7155-4X (DEMA) TO HPA. 
* 
* 
* COMHPAERT  PWL  82/08/04
* HPA35      MODSET HPA50619 DELETES CE ERROR CODE AND SUB-CODE 
*            FROM 2550 DETAIL REPORTS BECAUSE THE ARE INCLUDED
*            IN THE TEXT OF THE MESSAGES. 
* 
* 
*         PSR   DIMA800 
* HPA39   REF   08/25/82
*         MODSET DIMA800 SUPPRESSES UNREQUESTED LCN STATISTICS
*         REPORTS.  LCN STATISTICS CAN ONLY BE OBTAINED WHEN BOTH 
*         LCN DETAIL AND STATISTICS REPORTS HAVE BEEN REQUESTED.
*         (D=NC OR =ALL AND ST=NC OR =ALL.) 
* 
* 
* MALET12 JMO    82/09/02 
*         MODSET CORRECTS SYSRDESM AND SYSWRESM SO THEY DO NOT
*         READ OR WRITE PAST ESM EOI. DPSR 054347.
* 
* 
* HISTORY PMW   82/09/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L144*. 
* 
* 
* 
* 
* MALET   JMO    82/09/16 
*         MODSET CORRECTS MALET SO 5 CONSECUTIVE ESM
*         SYSRDS GIVE A STATUS OF 2 WHICH INDICATES 
*         EOI. DPSR 054363. 
* 
* 
* HPA2    PWL  82/08/13 
* HPA3    MODSET HPA039314 CORRECTS THE PROCESSING OF ECS MESSAGES. 
* HPA36   1. ECS MESSAGES WILL NO LONGER BE SORTED BY LINK CHARACTER
*            OR ERROR INCIDENT NUMBER.
*         2. DETAIL REPORT WILL BE REFORMATED.
*         3. BLANK LINES IN ANALYSIS REPORT (ADDRESSES CONTAIN NO 
*            DATA) WILL BE SUPPRESSED.
*         4. CHANNEL NUMBER AND UNIT NUMBER OF EC MESSAGES WILL BE
*            BLANKED OUT. 
*         5. UNKNOWN RECOVERY WILL BE LEFT BLANK. 
* 
* 
* HPA8    PWL  82/09/20 
*         MODSET HPA042804 CORRECTS THE PROBLEM OF COMPLEMENT 
*         DATA REPRESENTATION IN SHR DETAIL REPORT. 
* 
* 
* COMHPAERT 
* HPA22   RAS    82/09/13 
*         MODSET HPA054303 CHANGES THE 885 DSA FLOW SO THAT NO ATTEMPT
*         IS MADE TO ISOLATE LOST DATA ERRORS TO A SPECIFIC HEAD ON A 
*         FOUR HEAD PARALLEL DRIVE.  THIS SUPPORTS THE CHANGE TO THE
*         ERS RECEIVED FROM D. ROWE, 82/09/07.  THIS MODSET WAS 
*         CREATED USING THE DLT EDITOR, AND CORRESPONDS TO MODSET 
*         -DEMA03- ON FLOWPL. 
* 
* 
* HISTORY LJC   82/10/05
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L145*. 
* 
* 
* 
* 
*         DPSR  HPA042781 
* HPA     REF   09/28/82
* HPA1    MODSET HPA042781 PROVIDES ACCESS TO THE OLD HISTORY FILE FOR
* HPA23   MMF, SHR AND MEDIA REPORTS, WHEN THE HR (HISTORY READ) PARAM- 
* HPA4    ETER IS USED.  GENERAL ACCESS TO THE HISTORY FILE IS DENIED 
* HPA8    WITH THE HR PARAMETER, SINCE THE GENERATED SEF CONSISTS OF
*         RECORDS EXTRACTED FROM THE HISTORY FILE.  (REPORTS WHICH
*         RESULT FROM MERGED HISTORY AND SEF FILES WOULD BE INVALID:  
*         THE SUMMARY, SPA AND NEW HISTORY REPORTS AND NEW HISTORY
*         FILE.)  MODSET HPA042781 RESTORES ACCESS TO THE OLD HISTORY 
*         FILE, IN CONJUNCTION WITH THE HR PARAMETER, FOR SELECTED
*         FUNCTION/REPORTS WHICH DO NOT MERGE RECORDS FROM HISTORY AND
*         SEF FILES: THE MMF FUNCTION AND THE SHR AND MEDIA REPORTS.
*         EX: HP,H,HR,MMF=X,SHR,T,MF=H RESULTS IN THE FOLLOWING:  
*         1) MMF FUNCTION - CONFIGURATION TABLE READ FROM HISTORY FILE; 
*         2) SHR REPORT - PRODUCED FROM OLD HISTORY FILE; 
*         3) MEDIA REPORT - T,MF=H - PRODUCED FROM OLD HISTORY FILE.
*         MODSET HPA042781 ALSO CONTAINS AN ASSORTMENT OF CHECKS AND
*         MESSAGES TO PROTECT AND INFORM THE USER OF FILE AVAILABILITY
*         AND FILE REQUEST VALIDITY.  TO AVOID THE GENERATION OF INCOM- 
*         PLETE NEWHF AND NEWHF REPORTS, THE USER WILL NOT BE ABLE TO 
*         REQUEST A NEWHF WITH THE HR PARAMETER: A MESSAGE WILL RESULT
*         THAT THE NEWHF REQUEST HAS BEEN DENIED. 
* 
* 
*         PSR DIMA801 
* HPA1    REF 10/22/82
*         MODSET DIMA801 PREVENTS THE GENERATION OF JUNK RECORDS WITHIN 
*         HPA.  THE PROBLEM OCCURRED WHILE GENERATING A SEF FILE WITH 
*         HR (HISTORY READ) PARAMETER AND THE OLD HISTORY FILE DID NOT
*         CONTAIN ANY SPECIFED HR RECORDS TO EXTRACT.  EXAMPLE: HR=DT,
*         HR=EST OR HR=ESTUN AND THE HISTORY FILE DID NOT CONTAIN ANY 
*         SPECIFIED DATA, THE SEF WOULD CONTAIN A JUNK RECORD (THE FILE 
*         MARK) WHICH HPA WOULD CONTINUE PROCESSING.  MODSET DIMA801
*         ABORTS PROCESSING WHEN THIS CONDITION OCCURS, WITH THE
*         FOLLOWING MESSAGE:  
*         "--- OLDHF DID NOT CONTAIN SPECIFIED SEF DATA TO EXTRACT ---".
* 
* 
* HISTORY PMW   82/11/01
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L146*. 
* 
* 
* 
* 
*         PSR CMLA027 
* INITEM  REF 82/11/18
*         MODSET CMLA027 ADDS THE FOLLOWING LCN/REMOTE NAD ERROR CODES: 
*         - BML EC 2143B / HPA EC 1243B = ABNORMAL RESPONSE 
*         - BML EC 2144B / HPA EC 1244B = CONNECT IN PROGRESS TIMEOUT.
* 
* 
* HISTORY PMW   82/12/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L147*. 
* 
* 
* 
* 
* FMU       HNS 81/12/18
* 
*         PROVIDE A UTILITY FOR 885-4X DRIVES.
*         DPSR 034638 
* 
* 
* FMD       RFF     07/08/82
*           THIS MODSET WILL REMOVE THE *IF UPDATE DIRECTIVES FOR THE 
*           TSP SOURCE CODE IN THE FMD DECK. ALL NON-TSP CODE IN THE
*           FMD DECK WILL BE REMOVED. 
* 
* 
* FMD       RFF     07/08/82
*           THIS MODSET WILL ADD CODE TO THE FMD DECK TO WHICH WILL 
*           ENABLE IT TO TEST AN 885-4X DRIVE AS WELL AS THE 885-1X 
*           DRIVE AS IT NOW DOES.  DEFINING THE TERM SFMD DURING THE
*           UPDATE RUN WILL CAUSE THE TEST FMD TO BE COMPILED OR
*           DEFINING THE TERM PFMD DURING THE UPDATE RUN WILL CAUSE THE 
*           TEST FHD TO BE COMPILED.
* 
* 
* FMC       HNS 81/08/26
* 
*         FMC FOUR HEADS PARALLEL CORRECTIONS.
*         1. MOVE FMC17 AND RENAME IT FMC20.
*         2. SWAP ORDER OF ENOC/IPCS IN FMC18/19. 
*         3. ADD 4 HEADS MODULE NAMES (*IF PFMD). 
*         4. CONVERT ALL REFERENCES TO FMC TO COMPILE FHC CONDITIONALLY.
*         5. UPDATE DOCUMENTATION TO REFLECT CHANGES FOR 4 HEADS. 
*         6. ADD HEAD SELECT AND CHANNEL CHECKING LOOP CODE TO FMC18/19.
*         7. ADD CODE TO CHECK ALL SIX BITS OF NOC 3 IN FMC03.
*         8. UPDATE ISOLATION MESSAGES IN FMC03/18/19/20/21/22/23/
*            25/26/27.
*         9. ADD 30-SERIES FOR 844,40 FOR 885-1X, AND 50 FOR 885-4X.
*         10.CONVERT FMC24 TO TEST 4 HEADS IN LOW LEVEL.
*         11.ADD 4 HEADS PSFG(S). (FHDC/FHDD) 
*         12.UPDATE ERS FOR FHC AND 4 HEADS PARALLLEL.
*         13. MOVE CONTROLWARE CHECK IN FMC02 TO FMC989.
*         14. ADD CHECK FOR CONTROLWARE, CONTROLLER, AND DIAGNOSTIC 
*             COMPATIBILITY TO FMC02. 
*         15. CONVERT ALL MODULES OF FHC TO ALLOW DEVICE CODE 14. 
*         16. CONVERT FHC21/22/23/25/26/27 TO USE 6000 PROD. OVERLAY. 
*         17. ADD PARAMETER CHECKING SUBMODULES TO 30,40,AND 50 SERIES. 
*         18. ADD P8 PARAMETER CHECKS TO FMC00. 
*         19. CONVERT FHC29 TO LOW LEVEL AND NON-DRIVE TEST.
*         20. ADD LF DISPLAY TO UNEXPECTED ERROR MESSAGES.
*         21. CORRECT FORMAT 13 IN FMC01A FOR PFMD. 
*         22.ISOLATE A15-TP02 IN FMC01 (61006). 
*         23.FIX FHC02 WHEN CTRLR HANGS AT DS W/O CWARE.
*         24.ADD CHANNEL STATUS DISPLAY TO ERROR MESSAGES.
*         25.CORRECT MISCELLANEOUS TYPO(S). 
*         26.ADD FMC98X MODULES FOR DEMA1/DEMA2 PRODUCT OVERLAYS. 
*         27.UPDATE INTERNAL DOCUMENTATION. 
*         28.CORRECT DUPLICATE ERROR NUMBER IN FMC21B.
*         29. ADD STATUS VALID CHECKS TO FMC21/22/23. 
*         30.ADD CONTINUE TEST CAPABILITY TO 62002 ERROR MESSAGE. 
*         31.ADD GENERAL STATUS/A-REGISTER DISPLAY TO MSG 62002.
*         32.ADD PROCESSOR CLOCK TO CONTROL(S) IN FMC23.
*         33.ADD AL AND DC TO FMC99B DISPLAY. 
*         34.UPDATE RUN TIMES FOR ALL MODULES.
*         35.ENABLE NIC 2 TEST IN FMC20.
*         36.ADD LOST DATA TEST TO FMC20. 
*         37.CONVERT FMC20 TO DO FULL 16-BIT TEST.
*         38.ADD ISOLATION OF UPPER 8-BITS TO FMC20.
*         39.REMOVE GENERAL STATUS FROM FMC15/20. 
*         40.REMOVE GENERAL STATUS MESSAGES FROM FMC15B/15C/20A/20B.
*         41.PURGE FMC26 (NIC2 NOW TESTED BY FMC20).
*         42.ADD MISSING PWB(S) TO FMC23 MESSAGES.
*         43.ADD MISSING PWB(S) TO FMC18/19/20 MESSAGES.
*         44.ADD MISSING PWB(S) TO FMC03 MESSAGES (WIRED FANOUTS).
*         45.ADD MISSING PWB(S) TO FMC01 MESSAGES.
*         46.REMOVE DATA DISPLAY FROM MSG 6A007.
*         47.CORRECT ISOLATION MESSAGES IN FMC18A/B.
*         48.CORRECT ISOLATION MESSAGES IN FMC19A/B.
*         49.ADD BUSIN/OUT PARITY TEST TO FMC22.
*         50.ADD A18 TO FMC21/22 MESSAGES.
*         51.ADD FAILING DIFFERENCE TO FMC03 MSGS.
*         52.UPDATE DOCUMENTATION FOR FMC20.
*         53.REMOVE DATA DISPLAY FROM LOST CONTROLWORD MSG(FMC18) 
*         54.UPDATE DOCUMENTATION FOR FMC15.
*         55.ADD DOCUMENTATION FOR FMC27. 
*         56.CONVERT FMC02/03/04/07/08/09/11/13/15/18/19/20/21/22/23/24 
*            TO USE FHC010 FOR UNEXPECTED ERROR MESSAGES. 
*         57.DELETE FMC020/030/040/070/080/090/110/130/150/180/190/ 
*            200/210/220/230/240. 
*         58.RENAME FMC27/28/29/31/33 TO BE FMC25/26/27/28/29.
*         59.ADD NON-DRIVE SYNC BYTE SEARCH TEST (FMC24). 
*         60.ADD NON-DRIVE ECC FUNCTIONAL TEST (FMC27). 
*         61.ADD NON-DRIVE WRITE VERIFY TEST (FMC29). 
*         DPSR 037777 
* 
* 
* FEP     THIS MODSET ADDS THE DECK FEP TO THE CML LIBRARY. 
* 
* 
* MALET10 GLG    81/09/16 
*         MODSET ADDS DEMA SUPPORT TO MALET10.
* 
* 
* MALET20 GLG    81/09/15.
*         MODSET ADDS THE MALET COMPILER DEMA COMPILE SUPPORT 
*         TO MALET20. 
* 
* 
* MALETPF GLG    81/09/16.
*         MODSET ADDS COMDECK MALETPF TO CML 3.2 FOR DEMA SUPPORT.
* 
* 
* MALETPG GLG    81/09/16.
*         MODSET ADDS COMDECK MALETPG TO CML 3.2 FOR DEMA2 SUPPORT. 
* 
* 
* MALETPH GLG    81/09/16.
*         MODSET ADDS COMDECK MALETPH TO CML 3.2 FOR DEMA3 SUPPORT. 
* 
* 
* MALET2F GLG    81/09/15.
*         MODSET ADDS DECK MALET2F FOR DEMA1 SUPPORT TO MALET.
* 
* 
* MALET2G GLG    81/09/15.
*         MODSET ADDS DECK MALET2G FOR DEMA3 SUPPORT TO MALET.
* 
* 
* MALET2H GLG    81/09/15.
*         MODSET ADDS DECK MALET2H FOR DEMA3 SUPPORT TO MALET.
* 
* 
* LCI     PMW 82/04/01
*         THIS MODSET ADDS TEST LCI 
*         TO THE CL LIBRARY.
* 
* 
* D88        HNS 82/10/20 
* 
*         PROVIDE CONFIDENCE TEST (DH8) FOR DEMA SUBSYSTEM. 
*         1. ENABLE DH829 TO POST E0016 MESSAGE ON ERROR. 
*         2. ADD MODULES DH814/16/18/22/24 FOR DEMA SUPPORT.
*         3. ADD THREE SETS OF STATUS CRACKING SUBMODULES, ONE
*            FOR EACH DEMA PRODUCT OVERLAY. 
*         4. UPDATE DOCUMENTATION FOR DHEMA CHANGES.
*         5. ADD TWO NEW PSFG-S (CESM, DESM). 
*         6. CHANGE PARAMETER P8 TO BE FWA OF BUFFER DUMP.
*         7. CORRECT SPELLING ERRORS WHERE DISCOVERED.
*         8. ADD DOCUMENTATION FOR RESET ERRORS.
*         9. CONVERT THE SEEK TIMES IN DH813 TO DISPLAY IN DECIMAL. 
*         10.CORRECT DH809 TO DISPLAY CORRECT ERROR MESSAGE(E0004/E0005). 
*         11.CAUSE THE DH811 RUNNING MESSAGE LOOP COUNT TO INCREMENT. 
*         12.UPDATE DATA PATTERNS IN DH817 TO SUPPORT 4HP.
*         13.ADD CODE TO DELETE DEMA3 MODULES WHEN CMSE17X IS DEFINED.
*         14.CORRECT D8897I/98I TO DISPLAY DATA SYNC BYTR ERR MSG.
* 
* 
* D88        HNS 82/10/25 
* 
*         REMOVE *IF TSP-S FROM D88.
* 
* 
* FMD       RFF     12/16/82
*           THIS MODSET WILL REMOVE A EXTRA LINE OF CODE IN THE FMD DECK
*           WHICH CAUSES FMD98K MODULE TO GET COMPILE ERRORS WHEN 
*           COMPILED UNDER MALET. 
* 
* 
* HPA,HPA3   PWL  82/10/26
* HPA36      MODSET CMLA005 PROCESSES 865, 875 MAINTENANCE REGISTER 
*            DATA TO GENERATE DETAIL AND ANALYSIS REPORTS.
* 
* 
* FMU        HNS 82/12/13 
* 
*         FMU26, 27 DESTROY UTILITY MAPS. 
* 
* 
* HISTORY PMW   83/01/04
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L148*. 
* 
* 
* 
* 
* HPA31   RAS    82/12/20 
* HPA32   MODSET CMLA042 CHANGES THE NAME OF THE COMPASS SUBROUTINE 
* HPA33   *INITEM* TO *INTEMXX*, WHERE XX INDICATES THE OVERLAY TO
* HPA34   WHICH THE SUBROUTINE APPLIES.  THIS WILL ALLOW THESE
* HPA35   SUBROUTINES TO BE MORE EASILY MANIPULATED USING THE SYSTEM
* HPA36   UTILITIES *LIBEDIT* AND *COPYL*, SINCE THE SUBROUTINE WILL
* HPA37   NOW HAVE A UNIQUE NAME FOR EACH DIFFERENT OVERLAY.  THIS
* HPA38   WILL DECREASE THE AMOUNT OF SYSTEM RESOURCES REQUIRED TO
* HPA39   MAINTAIN THE PROGRAM. 
* 
* 
*         PSR CMLA028 
* HPERS   REF 83/01/19
* HPA     MODSET CMLA028 ADDS THE PROCESSING CAPABILITY OF SEF/4HPFMD 
* HPA1    RECORDS, RECORD TYPE=53B, DEVICE TYPE=DC, TO HPA. 
* HPA22   MODSET CMLA028 ALSO DROPS HPA SUPPORT OF THE FOLLOWING
* HPA3    OBSOLETE EQUIPMENTS:  
* HPA32   - 501 LINE PRINTER   - HPA RECORD TYPE 22B, DEVICE TYPE LP; 
* HPA33   - 808 DISK DRIVE     -  "    "     "   40B,   "     "   DB; 
* HPA34   - 813/814 DISK DRIVES-  "    "     "   41B,   "     "   DF; 
* HPA35   - 821 DISK DRIVE     -  "    "     "   42B,   "     "   DH; 
* HPA36   - 853/854 DISK DRIVES-  "    "     "   45B,   "     "   DD; 
* HPA37   - 863/865 DRUM       -  "    "     "   46B,   "     "   DC; 
* HPA38   - 6603 DISK DRIVE    -  "    "     "   47B,   "     "   AA/AC;
*         - LCC/M1000          -  "    "     "   53B,    "    "   CS/DA.
*         ANY ERRORS LOGGED AGAINST THE ABOVE DEVICES WILL APPEAR AS
*         UNUSED NORM MESSAGES.  ACTION WAS PROMPTED BY NOS REASSIGNMENT
*         OF DEVICE TYPES: DB AND DC REASSIGNED FROM THE 808 AND 863/865
*         TO DEMA AND 4HPFMD. 
* 
* 
* MALET10 JMO    82/11/18 
*         MODSET ALLOWS TWO PPS TO BE CALLED ON NOS 2 WITHOUT 
*         SETTING OR CLEARING THE DIS FLAG. PSR CMLA049.
* 
* 
* T7X     JMO    01/31/83 
*         MODSET CORRECTS CH NOT RESERVED ERROR IN T7X43 IF AN ERROR
*         IS DISPLAYED ON THE LAST RECORD OF THE CURRENT FILE BEFORE
*         THE ENDFILE COMMAND. PSR CML0056. 
* 
* 
* HISTORY LJC   83/02/09
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L149*. 
* 
* 
* 
* 
* FMC/FHC    HNS 83/01/20 
* 
*         FMC09/FHC09 EXAMINES WRONG PARAMETER BITS.
* 
* 
* FMC/FHC    HNS 83/01/20 
* 
*         FMC04/FHC04 TIME LIMIT CHECK IS INACCURATE. 
*         1. CORRECT DOC. ON DELAY TIME EQUATE. 
*         2. CHANGE LOWER TIME LIMIT CHECK TO USE B7. 
*         3. REMOVE 2**12 CARRY FROM QUOTIENT LOWER INCREMENT.
* 
* 
* FMC/FHC    HNS 83/01/20 
* 
*         FMC08/FHC08 UNEXPECTED ERROR DISPLAY MISSING. 
* 
* 
* FMC/FHC    HNS 83/01/19 
* 
*         FMC/FHC ISOLATION PERCENTAGES TOO LOW.
*         1. CORRECT FHC59 ISOLATION OF B23-2A33. 
*         2. CORRECT FHC02 ISOLATION OF CONTROLLER HUNG FAULTS. 
* 
* 
* FMC/FHC    HNS 83/01/20 
* 
*         FMC/FHC CONTAIN ILL-FORMATTED MESSAGES. 
*         1. CORRECT FORMAT OF MSG 69006H IN FMC15B/FHC15B. 
*         2. REMOVE REDUNDANT DATA FROM 6A010H IN FMC19A/FHC19A.
*         3. REMOVE REDUNDANT DATA FROM 69003H IN FMC15A/FHC15A.
* 
* 
* HPA36   PWL  83/02/09 
*         MODSET CMLA047 ADDS ESM SYNDROME CODE FAILING BITS TO 
*         ESM SINGLE BIT ERROR REPORT, STOPS THE PRINTING OF DOUBLE 
*         BIT ERRORS WHEN THE VALID BIT IS NOT SET, AND STOPS THE 
*         PRINTING OF PROGRAMMABLE SINGLE BIT COUNTER WHEN THE
*         COUNT IS ZERO.
* 
* 
* HPA38   PWL  83/01/12 
*         MODSET CMLA048 GENERATES DETAIL AND ANALYSIS REPORTS FOR
*         855 PROCESSOR ERROR MESSAGES AND DETAIL REPORT FOR MICRO- 
*         CODE/EI IDENTIFICATION. 
* 
* 
* DECK   MRL    83/02/24
*        MODSET CHANGES COMMENTS TO THE TROUBLE SHOOTING
*        MAP TO READ TROUBLE SHOOTING GUIDE 3-1.
* 
* 
* FMD    MRL    83/02/24
*        MODSET CHANGES MODULE 97T SO NOW THE 
*        ERROR MSG IS CORRECT.
* 
* 
* FMD     MRL   83/02/24
*         MODSET CHANGES A GOTO 44, TO A GOTO 46. 
*         THIS CHANGE IS IN MODULE 46.
* 
* 
* FMD    MRL    83/02/24
*        MODSET MAKES CHANGES TO MODULE 96J SO NOW
*        ISOLATION MODULES WILL BE DISPLAYED. 
* 
* 
* FMD    MRL    83/02/24
*        MODEST MAKES A CHANGE IN MODULE 48 WHERE 
*        A GOTO 30 IS NOW A GOTO 26.
* 
* 
* HISTORY PMW   83/03/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L150*. 
* 
* 
* 
* 
* MALET   JMO    03/11/83 
*         MODSET CORRECTS THE MULTIPLE ISSUING OF ERROR MESSAGES
*         ON AN ABORT. PSR CMLA069. 
* 
* 
* D88     JMO    03/14/83 
*         MODSET CORRECTS COMPILER ERRORS IN D88/DH8 MODULE 41. 
*         PSR CML0126.
* 
* 
*         PSR CMLA071 
* HPA     REF 83/03/25
* HPA3    MODSET CMLA071 PROVIDES THE PORT NUMBER FOR 875 MAINTENANCE 
* HPA36   REGISTER/SECDED ERRORS IN THE HPA DETAIL AND ANALYSIS REPORTS.
*         FIELD ENGINEERS WERE UNABLE TO DETERMINE THE ERROR SOURCE FROM
*         THE PREVIOUSLY-REPORTED CABINET NUMBER.  THESE 875 ERRORS ARE 
*         LOGGED IN THE NOS/BML WITH MSGID=205B, SYMPTOM CODE=334B/314B.
* 
* 
* FMD     JMO    83/03/23 
*         MODSET CORRECTS INTERMITTANT FALSE ERRORS IN FMD
*         MODULE 19 AND THE PROBLEM OF THE DRIVE GOING NOT
*         READY AS THE RESULT OF GIVING A GO AFTER THE
*         ERROR CONDITION. PSR CML0051. 
* 
* 
* HPA38   PWL  03/04/83 
*         MODSET CMLA064 ELIMINATES THE PRINTING OF P3 PFS
*         REGISTER CONTENTS OF ZEROS AND SEPARATES UNCORRECTED
*         ERROR COUNTS FROM THE TOTAL ERROR COUNTS. 
* 
* 
* HPA38   PWL  83/03/01 
*         MODSET CMLA067 SEPARATES SECDED DATA FROM MEMORY DATA IN
*         THE A170 MR SUMMARY REPORT, CONDENSES THE MEMORY SUMMARY
*         REPORTS AND CHANGES THE SUBHEADINGS TO BE MORE SPECIFIC.
*         IT ALSO MODIFIES CODE TO PROCESS REGISTER 21 FOR UN-
*         CORRECTED MEMORY ERRORS.
* 
* 
* HISTORY PMW   83/04/04
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L151*. 
* 
* 
* 
* 
* FMD     JMO    83/04/01 
*         MODSET CORRECTS INTERMITTANT FALSE ERRORS IN FMD MODULE 34
*         WHEN RUNNING ON 170 SERIES 835 TYPE HARDWARE. PSR CML0077.
* 
* 
* CIU     GWG    82/02/26 
*         THIS MODSET ADDS THE DIAGNOSTIS CIU TO THE CML
*         LIBRARY.
* 
* 
* FMD     JMO    83/04/07 
*         MODSET CORRECTS FMD MODULE 97R NOT TO CALLOUT THE 
*         DUPLICATE PWB OF A/B23 FOR THE ERROR CODE OF 0600B. 
*         PSR CML0125.
* 
* 
* HPA38   PWL  03/04/83 
*         MODSET CMLA063 GENERATES DETAIL AND ANALYSIS REPORTS
*         FOR P1 AND P2 ERROR MESSAGES. 
* 
* 
* FEP     JMO    83/04/14 
*         MODSET CORRECTS THE ERROR PROCESSORS TO GENERATE A
*         TRUE DISK ERROR MESSAGE AND TO DISPLAY THE CORRECT
*         CYLINDER TRACK AND SECTOR FOR A WRITE VERIFY ERROR. 
*         PSR CMLA038.
* 
* 
* D88/DH8 JMO    83/04/14 
*         MODSET CORRECTS THE ERROR PROCESSORS TO GENERATE A
*         TRUE DISK ERROR MESSAGE AND TO DISPLAY THE CORRECT
*         CYLINDER TRACK AND SECTOR FOR A WRITE VERIFY ERROR. 
*         PSR CMLA037.
* 
* 
* D88     JMO    83/04/22 
*         MODSET CORRECTS A DEFINE OF SFMD TO 2 LINES INSTEAD OF 3. 
*         PSR CMLA073.
* 
* 
* DH8     JMO    83/04/21 
*         MODSET CORRECTS DH8 TO INCLUDE PSFG FHDC ON AN
*         FMD ADDRESS FIELD CHECKWORD ERROR IN MODULES 15 
*         AND 17. PSR CMLA065.
* 
* 
* FMU     JMO    83/04/26 
*         MODSET CORRECTS FMU MODULE 04 AND 24 TO POST A MESSAGE
*         OF CANNOT SET FLAW IN FACTORY TRACK. PSR CML0165. 
* 
* 
* D44     JMO    83/04/25 
*         MODSET ADDS THE MESSAGE OF D4406 ERROR MODULE 41 MAY
*         HAVE TO BE RUN WHEN ENCOUNTERING AN ERROR ON EITHER 
*         A READ CODED OR COMPARE DURING THE FIRST PASS ONLY. 
*         PSR CML0107.
* 
* 
* D44     JMO    83/04/22 
*         MODSET CORRECTS D4407 TO CHECK FOR HT CONTROLWARE ON
*         A 7154 AND TO ISSUE A MESSAGE INDICATING THAT D4407 
*         REQUIRES FT CONTROLWARE. PSR CML0057. 
* 
* 
* HISTORY PMW   83/05/02
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L152*. 
* 
* 
* 
* 
* CMLINST RAS    83/1504/15 
*         MODSET CML0153 ADDS DECK CMLINST TO THE PROGRAM LIBRARY.
*         THIS DECK CONTAINS NEW CYBER CONTROL LANGUAGE (CCL) 
*         INSTALLATION PROCEDURES FOR CML.  REFER TO THE DSRB 
*         FOR INFORMATION CONCERNING THE USE OF THESE PROCEDURES. 
* 
* 
* D44     JMO    83/04/28 
*         MODSET CORRECTS D44 TO OUTPUT STATUS BUFFER WORDS 13
*         14 AND 15 FOR THE CORRECTION VECTORS. THIS MAKES D44
*         CONSISTANT WITH THE 844HT AND 844FT PRODUCT OVERLAYS. 
*         PSR CML0111.
* 
* 
* MLTDOC  JMO    83/05/04 
*         MODSET CORRECTS MLTDOC TO ALLOW FOR PAGE NUMBERS
*         GREATER THAN 999. PSR CML0025.
* 
* 
* HPA34    PWL  83/04/25
*          MODSET CMLA077 CORRECTS PRINT FORMAT FOR 819 DETAIL
*          REPORT.
* 
* 
* HPA36    PWL  83/05/06
*          MODSET CML0009 DELETES THE ADDRESS FIELD FROM THE DETAIL 
*          REPORT OF LCME SECDED ERROR COUNT BECAUSE THE INFORMATION
*          IS INCOMPLETE. 
* 
* 
* HPA36    PWL  83/05/06
*          MODSET CML0069 ELIMINATES THE PRINTING OF FAILING BIT
*          FOR LCME MULTIPLE BIT ERRORS.
* 
* 
* FMD     JMO    83/05/09 
*         MODSET CORRECTS FHD SO THE ISOLATION FOR 8005 ERROR 
*         CODE CALLS OUT A/B07 INSTEAD OF A/B11. PSR CML0174. 
* 
* 
* CMLINST RAS    83/05/12 
*         MODSET CMLA083 CORRECTS THE FOLLOWING PROBLEMS IN THE 
*         NOS/BE CML INSTALLATION PROCEDURES. 
*         1- CORRECTS AN ERROR IN THE DOCUMENATATION WHICH CAUSES 
*         PROCEDURE CML TO ABORT. 
*         2- CORRECTS A PROBLEM WHERE THE EDITLIB PARAMETER WAS NOT 
*         PASSED TO PROCEDURE CML2. 
*         3- UPDATES THE DOCUMENTATION TO REFLECT THE REQUIREMENT 
*         FOR PROCEDURE CML2 TO USE THE EDITLIB PARAMETER.
*         4- CHANGES THE TEST FOR THE EDITLIB PARAMETER IN CML2 SO
*         THAT IT IS EVIDENT WHAT PARAMETER IS BEING TESTED BY THE
*         STATEMENT.
*         5- CORRECTS THE COMMENT ON THE CML4 JOB STATEMENT.
* 
* 
* MALET   JMO     83/05/12
*         MODSET CORRECTS MALET PARAM LL DISPLAY OF 1750D 
*         WHEN 1000D IS SELECTED. PSR CMLA081.
* 
* 
* FMD     JMO    83/05/17 
*         MODSET CORRECTS FHD TO ISOLATE TO THE CORRECT BOARD ON A
*         08009 ERROR. PSR CML0187. 
* 
* 
* MALET   JMO    83/05/20 
*         MODSET CORRECTS MALET TO POST THE MESSAGE ON NOSBE OF 
*         RMS/AL GE 10 DISABLE UNITS NOT UNDER TEST ON CHCC.
*         PSR CML0181.
* 
* 
* MALET11 JMO    83/05/20 
*         MODSET CORRECTS MALET TO POST THE MESSAGE ON NOSBE OF 
*         RMS/AL GE 10 DISABLE UNITS NOT UNDER TEST ON CHCC.
*         PSR CML0181.
* 
* 
* CR1     JMO    83/05/25 
*         MODSET CORRECTS CR1 TO PAUSE ON THE ERROR CODE OF 0500
*         AND DISPLAY THE MESSAGE - UNEXPECTED EOR ON SCRATCH - 
*         ALSO ON THE NUMBER OF ERRORS AND THE MESSAGE - ABNORMAL 
*         TERMINATION - BEFORE EXITING THE MODULE. PSR CML0058. 
* 
* 
* CP1     JMO    83/05/25 
*         MODSET CORRECTS CP1 MODULE 21 TO PUNCH P4 NUMBER OF CARDS 
*         INSTEAD OF JUST 103 CARDS. PSR CML0121. 
* 
* 
* T7X     JMO    83/05/25 
*         MODSET CORRECTS T7X MODULE 36 TO ALLOW RUNNING ON A 9 TK
*         WITH ERROR CORRECTION DISABLED. PSR CML0071.
* 
* 
* COMHPAERT 
* HPA22   RAS    82/12/06 
*         MODSET CML0052 CORRECTS THE FOLLOWING PROBLEMS: 
* 
*         1- CORRECTS A PROBLEM WHERE SC107-X-SOFTWARE ADDRESS ERROR
*         IS ERRONEOUSLY GENERATED FROM A NOS/BE ERROR MESSAGE. 
* 
*         2- CORRECT MINOR TYPOGRAPHICAL ERRORS IN 4 ERROR MESSAGE
*         TEXTS.
* 
*         THIS MODSET WAS GENERATED BY THE DLT EDITOR AND CORRESPONDS 
*         TO MODSET 885FLO001 ON FLOWPL.
* 
* 
* FMD     JMO    83/05/26 
*         MODSET CORRECTS FHD 979 TO CALL OUT THE CORRECT MATCHED PAIR
*         FOR ERROR CODE OF 0800A. PSR CML0224. 
* 
* 
* HISTORY LJC   83/06/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L153*. 
* 
* 
* 
* 
* HPA38   PWL  83/05/23 
*         MODSET CMLA108 CORRECTS POTENTIAL BAD PAK LOCATIONS FOR 
*         P1/P2 FS MESSAGES AND CHANGES PAK NAMES FOR S1 MINUS
*         PROCESSOR FS MESSAGES.
* 
* 
* CMLINST RAS    83/05/16 
*         MODSET CMLA092 CORRECTS A TAPE MISPOSITIONING PROBLEM IN
*         CML1 FOR NOS/BE IF NEITHER 66X NOR 7X54 IS DEFINED IN THE 
*         CALLING PROCEDURE.  MISCELLANEOUS CORRECTIONS TO PROCEDURE
*         DOCUMENTATION ARE ALSO MADE.
* 
* LCI   DHW      83/06/08 
*       THIS CHANGE ALLOWS LCI TO EXECUTE WITHOUT ERROR 
*       WHEN THE REAL TIME CLOCK IS ENABLED IN THE NAD. 
* 
* 
* TFF     83/04/11
*         MODSET CORRECTS TFF98A SO THE LOOP COUNTER GETS CLEARED 
*         IF RUNNING A SECONDARY COUPLER. PSR MSL0175.
* 
* 
* SKEDULR JMO    83/06/08 
*         MODSET CORRECTS SKEDULR TO DETECT END OF INFORMATION IF 
*         THE LAST CARD IS NOT A /EOF. PSR CML0067. 
* 
* 
* D44     JMO    83/06/17 
*         MODSET CORRECTS D44 SO MODULE 17 IS PARAMETER DRIVEN AND
*         MOVED OUT OF THE CONFIDENCE PORTION AND INTO THE INDIVIDUAL 
*         SELECTABLE PORTION OF THE TEST. PSR CML0118.
* 
* 
* FMD     JMO    83/06/22 
*         MODSET CORRECTS FHD TO ISOLATE TO THE CORRECT HEAD GROUP
*         IF RETRY IS NOT PERFORMED. PSR CML0322. 
* 
* 
* D44     JMO    83/06/20 
*         MODSET CORRECTS D44 SO MODULES 35 AND 36 ARE PARAMETER
*         DRIVEN AS INDICATED IN THE 99 MODULE. PSR CML0055.
* 
* 
* SKEDULR JMO    83/06/14 
*         MODSET CORRECTS SKEDULR TO ID THE TFILE AND THEREFORE NOT 
*         ABORT IN A MMF ENVIRONMENT BECAUSE THE SAME TFILE BEING 
*         USED. PSR CML0136.
* 
* 
* HPA38   PWL  83/05/18 
*         MODSET CMLA091 ANALYZES IOU FAULT STATUS REGISTER CONTENTS
*         TO REPORT ERROR MESSAGES IN DETAIL REPORT AND TO SUMMARIZE
*         ERROR TYPES IN ANALYSIS REPORT. 
* 
* 
* HPA35   PWL  83/07/06 
*         MODSET CMLA114 REPORTS 2550 NPU C3 AND C4 STATISTICS
*         MESSAGES. 
* 
* 
* ELR     JMO    83/07/08 
*         MODSET CORRECTS ELR TO REPORT SINGLE BIT CHIP LOCATIONS IN
*         DECIMAL. PSR CML0340. 
* 
* 
* CYPFTN  DJU    06/22/83 
*         THIS MODSET CONVERTS CYPFTN TO ASSEMBLE UNDER 
*         FORTRAN VERSION 5 OR VERSION 4
* 
* 
* TIO     DJU    06/22/83 
*         THIS MODSET CONVERTS TIO TO ASSEMBLE UNDER
*         FORTRAN VERSION 5 
* 
* 
* REGEN   DJU    06/22/83 
*         THIS MODSET CONVERTS REGEN TO ASSEMBLE UNDER
*         FORTRAN VERSION 5 
* 
* 
* HISTORY PMW   83/07/15
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L154*. 
* 
* 
* 
* 
* D88/DH8     JMO    83/07/11 
*         MODSET CORRECTS DH897P AND DH898P SO THE DOCUMENTATION
*         REFLECTS THE CORRECT MODULE TO WHICH THEY EXIT. ALSO
*         CORRECTS D88 TO CLEAR THE MARGINS FOR THE NEXT ITERATION. 
*         PSR CMLA125.
* 
* 
* HPA35   PWL  83/07/11 
*         MODSET CML0339 MODIFIES 2550 DETAIL REPORT TO REFLECT THE 
*         FACT THAT CERTAIN CE ERRORS CAN BE REPORTED BY EITHER 
*         MODE-4 OR HASP TIP. 
* 
* 
* TFF     JMO    83/07/08 
*         MODSET CORRECTS TFF01 NOT TO ERROR ON THE THIRD PASS AFTER
*         DROPPING NAM. PSR CML0345.
* 
* 
* FMC/FHC     JMO    83/06/28 
*         MODSET CORRECTS FMC/FHC TO DELAY AFTER THE SEEK AND BEFORE
*         THE READ PROTECTED SECTOR IN FMC/FHC 28. THIS ELIMINATES
*         FALSE ERRORS FROM OCCURING. PSR CMLA126.
* 
* 
* MALET   JMO    83/07/08 
*         MODSET CORRECTS MALET SO AN AUTOMATIC GO IS NOT GIVEN ON A
*         TERMINAL INTERRUPT AT THE GO DROP MESSAGE. PSR CML0337. 
* 
* 
* MALET11   JMO    83/07/08 
*         MODSET CORRECTS MALET11 SO AN AUTOMATIC GO IS NOT GIVEN ON A
*         TERMINAL INTERRUPT AT THE GO DROP MESSAGE. PSR CML0337. 
* 
* 
* HPA3    PWL  83/07/22 
* HPA36   MODSET CMLA128 CORRECTS THE PROBLEM OF INCORRECT ADDRESS
*         FOR CY176 SECDED ERROR COUNT MESSAGES WITH SYNDROM BIT
*         FAILURES AND TOTALS THE COUNTS FOR 865/875 SECDED ERRORS
*         FOR SHR RECORDS.
* 
* 
* HPA38    PWL  83/07/26
*          MODSET CMLA127 ADDS CODE TO HPA38 TO REPORT 845 PROCESSOR
*          ERROR MESSAGES.
* 
* 
* HPA38   PWL  83/07/25 
*         MODSET CMLA130 MODIFIES HPA FOR THE MICROCODE/EI ID BML 
*         LOGGING CHANGES AND TO PROCESS S1 MINUS AND S1 FULL 
*         PERFORMANCE IOU MR MESSAGES.
* 
* 
* D44     JMO    83/07/28 
*         MODSET CORRECTS D4499 DISPLAY FOR MARGINS.
*         PSR CML0199.
* 
* 
* CMLINST RAS    83/07/25 
*         MODSET CMLA132 MODIFIES THE CML INSTALLATION PROCEDURES TO
*         INCLUDE SUPPORT FOR THE 834/7153 (ISD) DISK SUBSYSTEM.  THIS
*         SUBSYSTEM IS SUPPORTED ONLY UNDER NOS.
* 
* 
* CMLINST RAS    82/07/25 
*         MODSET CMLA135 MODIFIES THE CML1 INSTALLATION PROCEDURES IN 
*         THE FOLLOWING MANNER- 
* 
*         1- CHANGES CML1 TO SUPPORT BUILDING THE RANDOM PL FROM
*            FILE 2 INSTEAD OF FILE 1.
*         2- SUPPORTS THE USE OF LABELED INSTEAD OF UNLABELED CML 
*            RELEASE TAPES. 
*         3- CHANGES CML1 FOR NOS/BE SO THAT BINARIES OF MCDUMP 
*            (FILE 10) AND MCCOMP (FILE 11) ARE LOADED IF THE 800 
*            PARAMETER IS DEFINED.
*         4- REDUCES THE FIELD LENGTH REQUIRED FOR THE LIBEDIT
*            IN CML4 FROM 160K TO 120K OCTAL. 
*         5- CHANGES THE LOGIC IN CML5A SO THAT THE PRECOMPILED 
*            MALET DIAGNOSTIC BINARY (CONTAINED IN FILE 14 OF 
*            THE CML RELEASE TAPE) WILL BE SAVED IF THERE ARE 
*            NO MODIFICATIONS TO BE INCORPORATED INTO THE 
*            DIAGNOSTIC.  THIS IS IN LIEU OF RECOMPILING THE
*            DIAGNOSTIC DURING INSTALLATION.  THIS CHANGE WILL
*            CONSIDERABLY REDUCE THE TIME AND SYSTEM RESOURCES
*            REQUIRED FOR CML INSTALLATION. (THIS CHANGE APPLIES
*            TO NOS ONLY.)
* 
* 
* CMLINST RAS    83/05/31 
*         MODSET CMLA138 ADDS AN INTERFACE PROCEDURE WHICH, WHEN PLACED ON THE
*         CML TAPE AS THE FIRST FILE, CAN BE CALLED DIRECTLY TO EVOKE CML 
*         INSTALLATION.  THIS MODSET ALSO MAKES MINOR CHANGES TO THE
*         EXISTING CML PROCEDURES TO MAKE THEM COMPATIBLE WITH THIS INTERFACE 
*         AND TO UPDATE THE DOCUMENTATION.
* 
* CMLINST RAS    83/07/25 
*         MODSET CMLA133 MODIFIES THE CML INSTALLATION PROCEDURES TO
*         UNCONDITIONALLY ASSEMBLE MLD/SBP FROM THE CML PROGRAM 
*         LIBRARY.
* 
* 
* CMLINST RAS    83/07/25 
*         MODSET CMLA134 ADDS A NEW PARAMETER TO THE INSTALLATION 
*         PROCEDURES WHICH WILL ALLOW THE USER TO SPECIFY THAT ONLY 
*         FTN4 IS AVALIABLE ON THE HOST SYSTEM (FTN5 NOT AVALIABLE).
*         IF KEYWORD "FTN4ONLY" IS INCLUDED ON THE BEGIN STATEMENT, 
*         ALL FORTRAN PROGRAMS WILL BE COMPILED USING FTN4.  IF OMITTED,
*         CERTAIN FORTRAN PROGRAMS WILL BE COMPILED USING FTN5. 
* 
* 
* HISTORY PMW   83/08/02
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L155*. 
* 
* 
* 
* 
* MLD     JMO    83/07/11 
*         MODSET CORRECTS THE PRODUCT OVERLAYS SO THE COMMON ERROR
*         MESSAGES ARE IDENTICAL AS INTENDED. PSR CMLA115.
* 
* 
* LOW     JMO    83/07/06 
*         MODSET CORRECTS LOW PRODUCT OVERLAY TO RUN ON 835 AND 855 
*         AND CHANNEL SWITCHES. PSR CML0328.
* 
* 
* 580     JMO    83/07/06 
*         MODSET CORRECTS 580 PRODUCT OVERLAY TO RUN ON 835 AND 855 
*         AND CHANNEL SWITCHES. PSR CML0328.
* 
* 
* MLTDOC  DJU   83/7/22 
*         THIS MODSET CONVERTS MLTDOC TO COMPILE UNDER
*         FORTRAN VERSION 5 
* 
* 
* FMD     JMO    83/07/29 
*         MODSET CORRECTS FMD OF PROBLEMS FOUND WHILE TESTING FHD.
*         PSR CMLA084.
* 
* 
* LCM     DHW     83/07/21
*         THIS CHANGE ALLOWS LCM TO BE EXECUTED ON
*         A TRANSMIC NAD.  CODE IS ADDED  TO  PRE-
*         VENT ADDRESSES FF01 TO FFFF  FROM  BEING
*         TESTED IF A TRANSMIC NAD IS SELECTED  BY
*         PARAMETER P1 = 17.
* 
* 844FT   JMO    83/08/08 
*         MODSET CORRECTS THE PRODUCT OVERLAY TO TEST CONTROLLER
*         CONNECTED ON A STATUS COMMAND. PSR CMLA078. 
* 
* 
* FMDFT   JMO    83/08/08 
*         MODSET CORRECTS THE PRODUCT OVERLAY TO TEST CONTROLLER
*         CONNECTED ON A STATUS COMMAND. PSR CMLA079. 
* 
* 
* MALET12     JMO    83/08/16 
*         MODSET CORRECTS MALET12 TO SET SUSPEND INPUT FLAG ON PPU
*         HALT. THIS ALLOWS FOR A DIRECTIVE AFTER AN ERROR OCCURS 
*         DURING BATCH MODE AND MULTIPLE COPIES. PSR CML0215. 
* 
* 
* HPA3    JDG/83/08/16
*         MODSET CML0146 CORRECTS THE PROBLEM OF PRINTING GCR-RECOVERED 
*         READ ERRORS ON NON-GCR UNITS AND REPORTING THEM INCORRECTLY 
*         ON GCR CAPABLE UNITS. 
* 
* 
* HPA9    JLD 08/12/83
*         MODSET CML0027 INSERTS THE EARLIEST AND LATEST USAGE DATES
*         INTO THE TAPE MEDIA SUMMARY EXCESSIVE ERROR REPORT. 
* 
* 
* HPA37   PWL  83/08/04 
*         MODSET CML0081 ADDS TOTAL MOUNTS PER MST TO THE MSS 
*         ANALYSIS REPORT.
* 
* 
* CMLINST RAS    83/08/15 
*         MODSET CMLA148 PREVENTS THE INSTALLATION PROCEDURE "CMLINST"
*         FROM PERFORMING A LIBGEN IF RUNNING ON NOS4 OR NOS5.  THOSE 
*         VERSIONS OF NOS DO NOT SUPPORT EXECUTION OF CCL PROCEDURES FROM 
*         A LIBRARY FILE. 
* 
* CMLINST RAS    83/08/15 
*         MODSET CMLA145 MAKES THE FOLLOWING CHANGES IN DECK CMLINST. 
* 
*         THE MODSET CORRECTS THE GENERATION OF NON-FATAL LOADER
*         ERRORS IN REGEN AND TIO WHEN THOSE PROGRAMS ARE COMPILED
*         USING FTN5.  THE ERRORS WERE CAUSED BY LOADING PROGRAMS FROM
*         THE FTN4 LIBRARY (SL-FORTRAN) INSTEAD OF THE FTN5 LIBRARY 
*         (SL-FTN5LIB).  THE PROBLEM OCCURS ONLY WHEN THE FTN5 BINARIES 
*         ARE LOADED AFTER FTN4 BINARIES DURING THE SAME LOAD SEQUENCE. 
*         THE PROBLEM IS CORRECTED BY SPLITTING THE LOAD OF THE CPU 
*         PROGRAMS INTO TWO SEPARATE LOAD SEQUENCES WHEN REGEN AND TIO
*         ARE COMPILED USING FTN5.
* 
*         CORRECTS AN ERROR IN NOS/BE DOCUMENTATION.
*         IT CHANGES THE "INHIBIT UNLOAD" PARAMETER ON THE LABEL
*         STATEMENT FROM "IU" TO "X=IU".
* 
*         REMOVES THE "NOTSECURE" STATEMENTS FROM THE UPDATE INPUT
*         STREAM IN JOB CML2.  THEY ARE NO LONGER NEEDED IN THIS JOB. 
* 
*         AN "EXIT,U." STATEMENT IS PLACED AFTER THE ATTACH OF ILOCK4 
*         IN NOS/BE JOB CML3.  THIS WILL KEEP JOB CML3 FROM ABORTING
*         SHOULD IT REQUIRE A RERUN.
* 
*         CHANGES NOS/BE PROCEDURE "CML" SO THAT ALL CREATED JOBS ARE 
*         RETURNED PRIOR TO REVERTING BACK TO THE CALLER. 
* 
* 
* CMLINST RAS    83/08/83 
*         MODSET CMLA149 MODIFIES THE INSTALLATION JOB CML4 TO REQUEST A
*         RUNNING FIELD LENGTH (RFL) OF 160K OCTAL OR THE VALUE OF MFL, 
*         WHICHEVER IS LESS.  THIS WILL ALLOW CML TO BE INSTALLED ON 65K
*         SYSTEMS.
* 
* 
* CMLINST RAS    83/08/16 
*         MODSET CMLA144 ADDS PROCEDURES "BININST" AND "LDMAL" TO DECK
*         "CMLINST".  THESE PROCEDURES SUPPORT THE NOS REPACKAGING
*         EFFORT AND IS USED WHEN PERFORMING A BINARY INSTALLATION
*         OF CML.  THE PROCEDURES CAN BE EXECUTED ONLY ON NOS 2.1 LEVEL 
*         580 AND LATER SYSTEM LEVELS.
* 
* 
* MLD     JMO    83/08/22 
*         MODSET CORRECTS THE CML PL TO ASSEMBLE ALL THE PRODUCT
*         OVERLAYS FOR NOS AND TO DELETE MSS FROM NOSBE.
*         PSR CMLA150.
* 
* 
*         JLD 08/23/83
* HPA4    MODSET CML0096 ENABLES WRITING AND CHANGING CONFIGURATION 
*         RECORD LONGER THAN 162 ENTRIES. 
* 
* 
* HPA3    JLD 83/08/26
*         MODSET CML0190 INCREASES TABLE SIZES TO ENABLE PRINTOUT 
*         OF UP TO 70 LINES OF ERRORS FOR EACH UNIT ANALYSIS REPORT.
* 
* 
* CMLINST RAS    83/08/26 
*         MODSET CMLA153 CORRECTS THE FOLLOWING PROBLEMS IN THE CML 
*         INSTALLATION PROCEDURES.
* 
*         - CORRECTS NOS/BE PROCEDURE CML1 SO THAT THE PARAMETER "CEID" 
*         IS PROPERLY PASSED. 
* 
*         - CORRECTS NOS/BE JOB CML2 SO THAT FTN5 CAN BE USED TO
*         COMPILE REGEN AND TIO.  THIS IS ACCOMPLISHED BY HAVING FTN5 
*         WRITE THE RELOCATABLE BINARY ON A DIFFERENT LOADER INPUT FILE 
*         THAN DOES FTN4, AND PERFORMING 2 SEPARATE LOAD SEQUENCES. 
* 
*         - CORRECTS NOS/BE JOB CML3 SO THAT THE SYSTEM VERSION 
*         (SYSVER) IS INCLUDED IN THE UPDATE INPUT DIRECTIVE STREAM.
* 
*         - CORRECTS A TYPOGRAPHICAL ERROR INTRODUCED BY MODSET CMLA134 
*         WHICH CAUSES NOS/BE JOB CML2 TO ABORT.
* 
*         - ADDS EXIT PROCESSING TO PROCEDURE "CMLINST".
* 
*         - CORRECTS NOS AND NOS/BE JOB CML6 SO THAT MLTDOC CAN BE
*         COMPILED PROPERLY WHEN COMPILING UNDER FTN4.
* 
*         - INCREASES THE FIELD LENGTH REQUIREMENTS IN THE EDITLIB
*         DIRECTIVES FOR TIO TO 53000.  THIS ADDITIONAL FIELD LENGTH IS 
*         REQUIRED WHEN TIO IS COMPILED USING FTN5. 
* 
* 
* 
* HISTORY LJC   83/09/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L156*. 
* 
* 
* 
* 
* ELR     JMO    83/09/08 
*         MODSET CORRECTS ELR TO GIVE THE CORRECT CABINET ON
*         FOUR MILLION WORD ESM. PSR CML0373. 
* 
* 
* LCN     MSF    83/08/29 
*         MODSET CHANGES THE LOOP BACK FUNCTION CODE FROM 300B
*         TO 205B IN THE LCN PRODUCT OVERLAY.  PSR CMLA059. 
* 
* 
* DTC     JMO    83/09/01 
*         MODSET CORRECTS DTC TO RECOGNIZE CHANNEL STATUS ERRORS
*         AND NOT TO GIVE VERBAL DESCRIPTIONS FROM CHANNEL STATUS 
*         MISTAKEN FOR DETAILED STATUS. PSR CML0367.
* 
* 
* FMC/FHC     JMO    83/09/08 
*         MODSET ADDS DOCUMENTATION TO FMC TO NOTE THE FACT 
*         THAT FMC02 MAY CAUSE RAM/ROM PES DURING HIGH CHANNEL
*         ACTIVTIY (MASS STORAGE CHANNELS). PSR CML0208.
* 
* 
*         PSR CMLA143 
* HPERS   REF 83/08/12
* HPA     MODSET CMLA143 PROCESSES NEW NOS DISK MESSAGES AND
* HPA3    GENERATES APPROPRIATE HPA REPORTS FOR THE FOLLOWING:  
* HPA34   1) ISD SUBSYSTEM ERRORS FROM THE ERROR LOG; 
*         2) ISD SUBSYSTEM DIAGNOSTICS FROM THE BML;
*         3) FUNCTION TIMEOUT ENHANCEMENTS: 844/885/FSC/DEMA/PFMD/ISD.
* 
* 
* HPA38  PWL  83/08/31
*        MODSET CMLA147 REPORTS MEMORY, IOU AND PROCESSOR MAINTENANCE 
*        REGISTER MESSAGES AND SECDED ERRORS MESSAGES FOR 810, 820. 
*        IT ALSO BY-PASSES P3 MR BITS THAT ARE NOT USED FOR ERROR 
*        REPORTING IN ORDER TO REDUCE FIELD LENGTH. 
* 
* 
* CMLINST GHS    83/09/22 
* 
*         MODSET CMLA156 CORRECTS  PROCEDURE CML TO PROPERLY EXIT.
* 
* 
* MALETPG MSF    83/04/06.
*         MODSET ADDS THE WRITECB COMMAND TO THE DEMA2 LANGUAGE 
*         COMPILER.  PSR CMLA022. 
* 
* 
* DEMA2   DEH    83/09/10 
*         THIS MODSET ADDS WRITECB COMMAND TO DEMA2 PRODUCT OVERLAY.
*         PSR  CMLA022. 
* 
* 
* MLD     JMO    83/09/15 
*         MODSET ADDS THE PERMANENT DEFINES OF LSFMD AND FSD
*         TO THE CMLPL. PSR CMLA155.
* 
* 
* D44     JMO    83/09/21 
*         MODSET CORRECTS D4406 TO PRINT A MESSAGE FOR EACH MARGIN. 
*         PSR CML0250.
* 
* 
* HPA34   JLD 83/09/15
*         MODSET CML0227 CHANGES CODE WHICH UNDER CERTAIN 
*         CIRCUMSTANCES WOULD GIVE EXTRA BLANK PAGES IN THE DISK
*         POSITION ANALYSIS SUMMARY.  ALSO UPDATES DOCUMENTATION
* 
* 
* MALETPA MSF    83/09/16.
*         MODSET ADDS THE WRITECB COMMAND TO THE FMDFT LANGUAGE 
*         COMPILER.  PSR CMLA021. 
* 
* 
* FMDFT     JMO    83/09/16 
*         MODSET ADDS WRITECB COMMAND TO FMDFT PRODUCT OVERLAY. 
*         PSR CMLA021.
* 
* 
* FEP     JMO    83/09/23 
*         MODSET ADDS A PARAGRAPH TO RESTRICTIONS AND APPLICATIONS ABOUT
*         STRESS TESTING WITH FEP. PSR CML0371. 
* 
* 
* HPA37   JLD 83/09/22
*         MODSET CML0307 CHANGES AN3MS7 SO THAT THE MFID IS PROPERLY
*         REPORTED IN THE USAGE LINE OF THE MSS ANALYSIS REPORT 
* 
* 
* SKEDULR     JMO    83/08/10 
*         MODSET CORRECTS SKEDULR TO DO TWO CYCLES ON THE FIRST 
*         RUN AFTER A CLOCK WRAP WAS ENCOUNTERED. THIS ASSURES
*         THAT ANY JOBS MISSED BY SKEDULR BEFORE MIDNIGHT ARE 
*         SUBMITTED EVEN THOUGH THE DATE HAS CHANGED. PSR CML0176.
* 
* 
* FMU     JMO    83/09/27 
*         MODSET CHANGES FMU MODULES 13, 33 AND 57 TO ALLOW ARCHIVE OF
*         FACTORY AND UTILITY MAPS OR ONLY FACTORY OR ONLY UTILITY MAPS 
*         USING PARAMETER P5. PSR CML0249.
* 
* 
* HISTORY PMW   83/10/04
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L157*. 
* 
* 
* 
* 
* MALET   JMO    83/09/29 
*         MODSET ADDS THE SCRATCH FILE NAME TO THE PARAMETER DISPLAY. 
*         ALSO CORRECTS THE ERROR MESSAGE FOR SCRATCH= DIRECTIVE. 
*         PSR CMLA158.
* 
* 
* MALET11  JMO    83/09/29
*         MODSET ADDS THE SCRATCH FILE NAME TO THE PARAMETER DISPLAY. 
*         ALSO CORRECTS THE ERROR MESSAGE FOR SCRATCH= DIRECTIVE. 
*         PSR CMLA158.
* 
* 
* HPA     JLD 83/09/27
* HPA1    MODSET CML0296 CHANGES THE FOLLOWING SUBROUTINES: 
* HPA2    SETREF - CHANGED TO CORRECTLY SET FLAGS TO ENABLE HUID CHECKS 
* HPA3    INPTST1 - CHANGED TO ALLOW BUILD OF INITIAL MMF CONFIG TABLE
* HPA5    RDHIS1 - CHANGED TO USE SETREF FOR HIST READ PARAMETER
*         SETPAR1 - CHANGES FROP ARRAY ENCODING FOR BYP ERR AND HUID
*         EDIT2 - CHANGES BYPASS ERROR CODE CALL
*         INVRPT2 - CHANGED TO PRINT MFID FOR INTERVENTION REPORT 
*         MATCH2 - WHEN EST PUT INTO HUID FIELD IT IS CHANGED TO DECIMAL
*         GNR3 - CHANGED TO BYPASS UNIT CHECK IF MMF DEFINED
*         GRAPH5 - CHANGED TO DEFINE IFLD(FHUID) WHEN NEEDED FOR MMF
* 
* 
* LSP         HNS 83/08/10
* 
*         LSP DOES NOT SUPPORT PARITY ENHANCED ESM. 
* 
*         1.  UPDATE ERS FOR PARITY ENHANCED MIU PARAMETER. 
*         2.  UPDATE DOCUMENTATION FOR LSP35. 
*         3.  ADD EQUATES TO LSP35 FOR *READ* AND *DBLERR*. 
*         4.  ADD READ AND STATUS CHECK FOR DOUBLE ERROR TO LSP35.
*         5.  UPDATE LSP99B FOR PARITY ENHANCED MIU PARAMETER.
* 
* 
* FMC     JMO    83/10/06 
*         MODSET CORRECTS FMC/FHC TO NOT ERROR IN MODULE 24 WITH
*         A08 AND A02 CONTROLWARE. PSR CMLA163. 
* 
* 
* MSSCSU  JMO    83/10/12 
*         MODSET CORRECTS MSS PRODUCT OVERLAYS TO RUN ON CYBER 170
*         MODEL 855. PSR CML0411. 
* 
* 
* MSSMST  JMO    83/10/12 
*         MODSET CORRECTS MSS PRODUCT OVERLAYS TO RUN ON CYBER 170
*         MODEL 855. PSR CML0411. 
* 
* 
* MSSMSC  JMO    83/10/12 
*         MODSET CORRECTS MSS PRODUCT OVERLAYS TO RUN ON CYBER 170
*         MODEL 855. PSR CML0411. 
* 
* 
* HPA1    JLD 83/10/25
*         MODSET CML0308 CHANGES INPTST1 TO CHECK FOR END OF
*         INFORMATION BEFORE DECLARING THE RSEF FILE TO BE EMPTY. 
* 
* 
* HPA5   PWL  83/10/24
*        MODSET CMLA110 PREVENTS THE PRINTING OF THE LAST EMPTY 30 DAY
*        ERROR HISTORY GRAPH WHEN THERE IS NO INPUT.
* 
* 
* HPA9    JDG 83/10/28
*         MODSET CML0298 CHANGES THE THRESHOLD FOR PRINTING THE TAPE
*         UNIT EVALUATION GRAPH IN THE MEDIA SUMMARY REPORT.
* 
* 
* CMLINST RAS    83/10/31 
*         MODSET CMLA164 ADDS SUPPORT FOR THE LARGE SECTOR 885 DISK TO
*         THE CML INSTALL PROCEDURES.  THE PROCEDURES MODFIED 
*         INCLUDE-
* 
*         BININST     CML 
*         CMLINST     CML5
* 
*         IF "885LS" IS SPECIFIED IN THE CALL TO "CMLINST" OR AN
*         AFFIRMATIVE RESPONSE IS GIVEN WHEN PROMPTED BY "BININST", 
*         DIAGNOSTICS FLD AND DL8 WILL BE INCLUDED IN THE USER'S
*         PERMANENT FILE BASE.  DIAGNOSTICS FMC AND FMU WILL ALSO 
*         BE INCLUDED IF NOT LOADED BY OTHER PARAMETERS (7155/885/DEMA).
* 
*         THIS MODSET ALSO CLEANS UP PROCEDURE "LDMAL" TO STANDARDIZE 
*         THE PROCESSING OF INFORMATIVE MESSAGES, AND CAUSES THE 885
*         DSA TABLES TO BE INCLUDED IN HPA IF "DEMA" IS SPECIFIED.
* 
* 
* CMLINST RAS    83/10/31 
*         MODSET CMLA165 CORRECTS THE NOS/CML INSTALLATION PROCEDURES 
*         BININST AND CML5 SO THAT THE CORRECT MODULES ARE LOADED FOR 
*         MALET DIAGNOSTIC FSD. 
* 
* 
* MUX     JMO    83/11/02 
*         MODSET CORRECTS MUX TO ALLOW TFE TO RUN WITHOUT FALSE ERRORS
*         ON SYNC CLAS. PSR CML0417.
* 
* 
* HISTORY PMW   83/11/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L158*. 
* 
* 
* 
* 
* LSP         HNS 83/11/14
* 
*         LSP FAILS IN PARITY ENHANCED MIU MODE.
* 
* 
* 
* HPERS   JLD 83/09/22
* HPA21   MODSET CML366A CHANGES SORT TO USE CONTINUATION REEL NUMBER 
* HPA33   AS WELL AS TAPE VSN.  CHANGES MEDIA TO UNCONDITIONALLY USE
* HPA9    BOTH. UPDATES HPERS DOCUMENTATION.
* 
*       **********  HPERS   ****************
* 
* FMU     JMO    83/11/15 
*         MODSET CORRECTS FMU TO CHECK FOR AN ERROR AFTER A REFORM
*         COMMAND. PSR CML0388. 
* 
* 
* FMDHT   JMO    83/11/15 
*         MODSET CORRECTS THE PRODUCT OVERLAYS TO TEST FOR A
*         FMD TYPE CONTROLLER IN RESERVE. PSR CML0020.
* 
* 
* FMDFT   JMO    83/11/15 
*         MODSET CORRECTS THE PRODUCT OVERLAYS TO TEST FOR A
*         FMD TYPE CONTROLLER IN RESERVE. PSR CML0020.
* 
* 
* DEMA1   JMO    83/11/15 
*         MODSET CORRECTS THE PRODUCT OVERLAYS TO TEST FOR A
*         FMD TYPE CONTROLLER IN RESERVE. PSR CML0020.
* 
* 
* DEMA2   JMO    83/11/15 
*         MODSET CORRECTS THE PRODUCT OVERLAYS TO TEST FOR A
*         FMD TYPE CONTROLLER IN RESERVE. PSR CML0020.
* 
* 
* DEMA3   JMO    83/11/15 
*         MODSET CORRECTS THE PRODUCT OVERLAYS TO TEST FOR A
*         FMD TYPE CONTROLLER IN RESERVE. PSR CML0020.
* 
* 
* FMD     JMO    83/11/15 
*         MODSET CORRECTS FMD70 TO DISPLAY THE SEEK TIME ON 
*         ERROR CODES 0B004 AND 0B005. PSR CML0262. 
* 
* 
* SKEDULR     JMO    83/11/21 
*         MODSET CORRECTS SKEDULR TO FORCE ITS ORIGIN TYPE ONTO THE 
*         SUBMITTED JOB. PSR CML0400. 
* 
* 
* D88     JMO    83/11/10 
*         MODSET CORRECTS D88 AND DH8 MODULE 17 TO BYPASS FACTORY MAP 
*         AND TRACK FLAWED SECTORS. PSR CML0426.
* 
* 
* FMD     JMO    83/11/10 
*         MODSET CORRECTS FMD AND FHD MODULE 47 TO BYPASS FACTORY MAP 
*         AND TRACK FLAWED TRACKS. PSR CML0425. 
* 
* 
* MLD     JMO    83/11/23 
*         MODSET CORRECTS MLD TO DO A *CALL COMPCUA RATHER
*         THAN XTEXT STATEMENTS FOR NOSBE. PSR CMLA170. 
* 
* 
* SBP     JMO    83/11/23 
*         MODSET CORRECTS SBP TO DO A *CALL COMPCUA RATHER
*         THAN XTEXT STATEMENTS FOR NOSBE. PSR CMLA170. 
* 
* 
* HISTORY PMW   83/12/12
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L159*. 
* 
* 
* 
* 
* D88     JMO    83/12/15 
*         MODSET CORRECTS D88 FOR A PFMD DEFINE IN THE DOCUMENTATION. 
*         PSR CMLA177.
* 
* 
* ATC     JMO    83/11/22 
*         MODSET CORRECTS ATC MODULES 38 AND 45 TO RUN
*         ON NON-GCR CONTROLLERS. PSR CML0206.
* 
* 
* HPA3,38  PWL  83/12/01
*         MODSET CMLA161 CORRECTS THE TOTAL OF SECDED ERROR 
*         COUNTS IN THE ANALYSIS REPORT FOR C170-8XX AND THE
*         CHECKING OF 810/830 ELEMENT ID AND MEMORY SIZE. 
* 
* 
* FMC     JMO    83/12/05 
*         MODSET CORRECTS FMC MODULE 00 TO ALLOW A UNIT 57. 
*         PSR CML0432.
* 
* 
* T6X     JMO    83/11/21 
*         MODSET ADDS MODULE T6X82 KILLER PATTERN TO T6X. 
*         PSR CML0313.
* 
* 
* LOW     GLG    83/12/02 
*         MODSET CML0164A ADDS THE ABLITY TO USE ANY FUNCTION WITH
*         THE FUN8 COMMAND WITHIN THE LOW LANGUAGE. 
* 
* 
* FMU         HNS 83/12/06
* 
*         FMU NEEDS SELECTIVE PACK FORMATTING.
* 
* 
* 
* FMC/FHC     HNS 82/12/09
* 
*         FHC 08 FAILS. 
* 
* 
* 
* FMC     JMO    83/12/16 
*         MODSET CORRECTS FMC/FHC MODULE 15 TO ADD RT BOARDS TO 
*         6901E ERROR. PSR CML0440. 
* 
* 
* MALET   JMO    83/12/06 
*         MODSET CORRECTS MALET TO SET THE ERROR FLAG ON ABORT. 
*         PSR CML0200.
* 
* 
* T7X     JMO    83/12/05 
*         MODSET CORRECTS T7X TO REFLECT VALLEY FORGE SPECS FOR 
*         STOP START TIMES. PSR CML0430.
* 
* 
* SBP     JMO    83/12/05 
*         MODSET CORRECTS SBP TO WAIT FOR THE OUTPUT REG TO 
*         CLEAR ON A MONITOR PAUSE FUNCTION. PSR CML0435. 
* 
* 
* D44     JMO    83/11/22 
*         MODSET ADDS MODULES 50 THROUGH 53 FOR PLOTTING
*         THE POSITIONER TIMING. PSR CML0405. 
* 
* 
* FTP     JMO    83/12/05 
*         MODSET CORRECTS FTP MODULE 06 TO ALSO CHECK NUMBER OF 
*         LINES AS WELL AS END OF PAGE. PSR CML0431.
* 
* 
*         PSR CMLA157 
* HPERS   REF 83/10/31
* HPA     MODSET CMLA157 PROCESSES NEW NOS DISK MESSAGES AND
* HPA3    GENERATES APPROPRIATE HPA REPORTS FOR THE FOLLOWING:  
* HPA32   1) CONTROLWARE LOGGED-DS/DFTERM MESSAGES; 
* HPA34   2) CONTROLWARE LOADED-OPERATOR MESSAGES;
*         3) CONTROLWARE LOADED-SYSTEM MESSAGES.
*         MODSET CMLA157 ALSO UPDATES THE DEFINITIONS FOR ISD 
*         DIAGNOSTIC MESSAGES.
* 
* 
* BCX     JMO    83/12/12 
*         MODSET ADDS BCX03 CONTROLWARE LOAD MODULE.
*         PSR CML0229.
* 
* 
* MY8     JMO    83/12/12 
*         MODSET ADDS MY803 CONTROLWARE LOAD MODULE.
*         PSR CML0229.
* 
* 
* FMU         HNS 83/11/21
* 
*         FMU NEEDS 885 ON-LINE FLAWING ROUTINE.
* 
* 
* 
*         PSR CMLA111 
* HPA     REF 83/12/27
*         MODSET CMLA111 ENABLES A MEDIA REPORT TO OCCUR FROM A SEF FILE
*         WHEN THE NS (NO-SORT) HPA PARAMETER IS SELECTED.  NS SPECIFIES A
*         PRE-SORTED SEF FILE FOR THE SOURCE OF INPUT DATA.  HPA WAS
*         ERRONEOUSLY SEEKING MEDIA DATA FROM AN EMPTY UNSORTED SEF 
*         (RSEF) FILE INSTEAD OF THE PRE-SORTED SEF (FSORT) FILE. 
* 
* 
* FMD     JMO    83/12/28 
*         MODSET CORRECTS FMD MODULES 46 AND 47 TO PROCESS REPEAT 
*         CONDITION 1 CORRECTLY. PSR CMLA179. 
* 
* 
* HPA4     TEF  83/12/29
*          MODSET CMLO097 LIMITS SHR 50 FIELDS TO 10 CHARACTERS 
* 
* 
* HPA3    PWL  83/12/28 
*         MODSET CML0421 SETS THE CORRECT MFID FOR THE FIRST
*         DISK ERROR MESSAGE AFTER A PACK S/N MESSAGE.
* 
* 
* HPA,HPA3  PWL  83/12/29 
* HPA36   MODSET CML0404 MODIFIES HPA TO PROCESS C176 CM SECDED 
*         UNIQUE ID AND ERROR COUNTS MESSAGES WITH RECORD TYPE
*         12B IN ORDER TO DISTINGUISH THEM FROM C170 CM SECDED
*         MESSAGES. 
* 
* 
* SKEDULR     JMO    84/01/04 
*         MODSET CORRECTS SKEDULR TO NOT GET CPM- ARGUMENT ERROR
*         ON NOS 2.2. PSR CML0446.
* 
* 
* CMLINST     JMO    84/01/05 
*         MODSET CORRECTS THE CML INSTALLATION PROC FOR SKEDULR 
*         THE ADDITION OF S=NOSTEXT IN THE COMPASS STATEMENT. 
*         PSR CML0446.
* 
* 
* HPA1    JDG 84/01/06
*         MODSET CMLA185 CORRECTS TYPING ERROR AND DELETES DUPLICATE LINE 
*         IN DECK RDHIS1 WHICH ERRORS WERE INTRODUCED BY ME IN MODSET 
*         CML0296 AND CAUSED HR PARAMETER OF FORM DTEEE TO NOT WORK.
* 
* 
* HISTORY PMW   84/01/09
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L160*. 
* 
* 
* 
* 
* MALET   MSF    83/07/14 
*         MODSET ADDS FSD SUPPORT TO MALET. 
*         PSR CMLA140.
* 
* 
* MALET11 MSF    83/06/20 
*         MODSET ADDS FSD SUPPORT TO MALET11.  PSR CMLA140. 
* 
* 
* MALET12     MSF    83/07/25 
*         MODSET ADDS ISD SUPPORT TO MALET12.  PSR CMLA140. 
* 
* 
* MALETPI GLG    83/02/17.
*         MODSET ADDS COMDECK MALETPI TO CML FOR FSD SUPPORT. 
*         PSR CMLA140.
* 
* 
* MALET2I GLG    83/02/17.
*         MODSET ADDS DECK MALET2I FOR FSD SUPPORT TO MALET.
*         PSR CMLA140.
* 
* 
* MLD     JMO    83/05/03 
*         MODSET INCREASES THE TIME LIMIT FOR SYSTEM COMMUNICATIONS 
*         FROM 2 SECONDS TO 4 SECONDS. PSR CMLA140. 
* 
* 
* ISD     JMO    83/07/25 
*         MODSET ADDS SUPPORT OF ISD TO MALET.
*         PSR CMLA140.
* 
* 
* FSD     MSF    83/09/08 
*         MODSET ADDS SUPPORT OF ISD TO MALET.
*         PSR CMLA140.
* 
* 
* MALET10 MSF    83/03/15.
*         MODSET ADDS LARGE SECTOR SERIAL FMD SUPPORT AND 
*         INTELLIGENT SMALL DISK SUPPORT TO DECK MALET10. 
*         PSR CMLA139.
* 
* 
* MALET20 MSF    83/03/16.
*         MODSET CMLA139B ADDS LARGE SECTOR SERIAL FMD SUPPORT
*         AND INTELLIGENT SMALL DISK SUPPORT TO DECK MALET20. 
*         PSR CMLA139.
* 
* 
* MALET2J MSF    83/01/05.
*         MODSET ADDS DECK MALET2J TO MALET FOR SUPPORT 
*         OF LARGE SECTOR SERIAL FMD.   CMLA139.
* 
* 
* MALETPJ MSF    83/01/04.
*         MODSET ADDS COMDECK MALETPJ TO CML 3.2 FOR SUPPORT
*         OF LARGE SECTOR SERIAL FMD.  PSR CMLA139. 
* 
* 
* MALET2K MSF    83/01/05.
*         MODSET ADDS DECK MALET2K TO MALET FOR SUPPORT 
*         OF LARGE SECTOR SERIAL FMD.   PSR CMLA139.
* 
* 
* MALETPK MSF    83/01/05.
*         MODSET ADDS COMDECK MALETPK TO MALET FOR SUPPORT
*         OF LARGE SECTOR SERIAL FMD.   PSR CMLA139.
* 
* 
* FMD     JMO    84/01/16 
*         MODSET CORRECTS FMD 47 DOCUMENTATION IN THE USE THE 
*         PARAMETER P2. PSR CMLA187.
* 
* 
* NLM     DHW    84/01/18 
*        THIS CHANGE ADDS DOCUMENTATION TO NLM
*        CONCERNING THE USE OF PARAMETER P2 BY
*        THE TEST NDP.
* 
* D88     JMO    84/01/12 
*         MODSET CORRECTS D88 AND DH8 MODULE 25 TO DO ERROR 
*         CORRECTION TO TEST THE HARDWARE AND CONTROLWARE.
*         PSR CML0455.
* 
* 
* 844HT   JMO    84/01/19 
*         MODSET CORRECTS THE PRODUCT OVERLAY TO DO ERROR CORRECTION. 
*         PSR CML0454.
* 
* 
* 844FT   JMO    84/01/19 
*         MODSET CORRECTS THE PRODUCT OVERLAY TO DO ERROR CORRECTION. 
*         PSR CML0454.
* 
* 
* D44     JMO    84/01/19 
*         MODSET CORRECTS D44 MODULE 10 TO DO ERROR CORRECTION
*         CORRECTION TO TEST THE HARDWARE AND CONTROLWARE.
*         PSR CML0454.
* 
* 
* COMHPAERT 
* HPA22   RAS    84/01/18 
*         MODSET CML0295 CORRECTS THE 67X DSA FLOW TO PROPERLY CHECK
*         FOR CRC1-CRC2 MISCOMPARE ERRORS.  THIS MODSET CHANGES 4 ERROR 
*         MESSAGES AND ADDS 4 ERROR MESSAGES. 
* 
* 
* NLM   DHW   84/01/26
*       THIS DECK MODIFIES MODULE NDM99A TO INDICATE
*       CHANGES IN PARAMETER P1 REQUIRED TO EXECUTE 
*       NDM ON A TRANSMIC NAD.
* 
* 
* HPA3,38  PWL 12/21/83 
*         MODSET CMLA175 UPDATES C170 8XX MAINTENANCE REGISTER
*         REPORTS TO INCLUDING THE FOLLOWING NOS FEATURES:  
*         1. DUAL CPU REPORTING FOR S1 AND S1CR.
*         2. THRESHOLDING OF CORRECTED PROCESSOR ERRORS.
*         3. PROCESSING OF UNCORRECTED PROCESSOR ERRORS.
*         4. CRITICAL ERROR LOGGING.
*         5. P1 SECDED CONTROL STORE ERORR LOGGING. 
* 
* 
* MLD     DEH    83/08/31.
*         THIS MODSET MODIFIES MLD IN ORDER TO PERFORM *CALLS 
*         OF COMDECKS LSFMD1 AND LSFMD2 UNDER A170 NOS. 
* 
* 
* LSFMD1  DEH    83/08/31.
*         THIS MODSET ADDS LSFMD1 PRODUCT OVERLAY TO MALET. 
*         LSFMD1 IS A DRIVER FOR LARGE SECTOR SERIAL FMD DISK 
*         SUBSYSTEMS WHICH USES AN 885-1X DRIVE IN 1 TO 1 
*         INTERLACE MODE. 
* 
* 
* LSFMD2  DEH    83/08/31.
*         THIS MODSET ADDS LSFMD2 PRODUCT OVERLAY TO MALET. 
*         LSFMD2 IS A DRIVER FOR LARGE SECTOR SERIAL FMD DISK 
*         SUBSYSTEMS WHICH USES AN 885-1X DRIVE IN 1 TO 1 
*         INTERLACE MODE. 
* 
* 
* FMU     BD 83/7/7 
* 
*         ADDITIONS TO FMU TO ADD LARGE SECTOR SERIAL CAPABILITY
* 
* 
* FMD     B.D   83/08/31
*        MODSET ADDS LSFMD TO FMD 
* 
* 
* FMC     BD 83/7/7 
* 
*         ADDITIONS TO FMC TO ADD LARGE SECTOR SERIAL CAPABILITY
* 
* 
* D88     BD 83/7/7 
* 
*         ADDITIONS TO D88 TO ADD LARGE SECTOR SERIAL CAPABILITY
* 
* 
* MLD     JMO    83/12/28 
*         MODSET CORRECTS THE PERMANENT DEFINES FOR LARGE SECTOR FMD. 
*         PSR CMLA181.
* 
* 
* MALET10     JMO    84/01/27 
*         MODSET ADDS ISMT SUPPORT TO MALET.
*         PSR CMLA190.
* 
* 
* 67X     JMO    83/12/14 
*         MODSET CORRECTS 67X PRODUCT OVERLAY TO SUPPORT ISMT.
*         PSR CMLA190.
* 
* 
* CMLINST RAS    840126 
*         MODSET CMLA193 CORRECTS A PROBLEM IN PROCEDURE CML5A OF 
*         THE NOS/CML INSTALLATION PROCEDURES WHERE THE CML PROGRAM 
*         LIBRARY WAS NOT BEING ATTACHED. 
* 
* 
* NLM   DHW   84/01/16
*       THIS DECK ALLOWS NLM TO LOAD AND MONITOR
*       TRANSMIC NAD TEST TNT.
* 
* 
*         PSR CML0477 
* HPA9    RAS 84/02/03
*         MODSET CML0477 ADDS CODE TO SUBROUTINE TAPREP9 TO 
*         CAUSE ARRAY "PRIM" TO BE WRITTEN TO TAPE10 (SCR1).
*         THIS DATA CAN THEN BE USED BY PROGRAM "MTPLOT" FOR
*         SUBSEQUENT PROCESSING.
* 
* 
* HISTORY PMW   84/02/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L161*. 
* 
* 
* 
* 
* MCCOMP  GLG    84/02/08.
*         MODSET ADDS DECK MCCOMP TO CML. 
* 
* 
* MCDUMP  GLG    84/02/08.
*         MODSET ADDS DECK MCDUMP TO CML. 
* 
* 
* MTPLOT  GLG    84/02/08.
*         MODSET ADDS DECK MTPLOT TO CML. 
* 
* 
* CRP     RVS     84/02/06
*        MODSET CRP ADDS CYBER RING PORT MALET MODULES
*        TO THE CML PL. 
* 
* 
* FMU     JMO    84/02/05 
*         MODSET ADDS MODULES FMU68, AND FMU681 TO FORMAT TRACKS. 
*         PSR CMLA174.
* 
* 
* D88     JMO    84/02/02 
*         MODSET CORRECTS D88, DH8 AND DL8 TO USE THE WRITECB 
*         COMMAND IN MODULE 11. PSR CMLA066.
* 
* 
* FSD     JMO    84/02/01 
*         MODSET ADDS MODULES FSD10, FSD98H AND FSD98I TO SUPPORT 
*         ICI PARITY STATUS TEST. PSR CMLA189.
* 
* 
* MALET     JMO    84/02/14 
*         MODSET CORRECTS MALETS CROSS REFERENCE TABLE TO BE
*         CORRECT WHEN IN BASE DECIMAL OR OCTAL. PSR CMLA194. 
* 
* 
* MALET10     JMO    84/02/14 
*         MODSET CORRECTS MALETS CROSS REFERENCE TABLE TO BE
*         CORRECT WHEN IN BASE DECIMAL OR OCTAL. PSR CMLA194. 
* 
* 
* MALET20     JMO    84/02/14 
*         MODSET CORRECTS MALETS CROSS REFERENCE TABLE TO BE
*         CORRECT WHEN IN BASE DECIMAL OR OCTAL. PSR CMLA194. 
* 
* 
* FSD     JMO    84/02/16 
*         MODSET CORRECTS FSD MODULE 96G DOCUMENTATION. 
*         PSR CMLA200.
* 
* 
* HPACOM2  PWL  84/02/06
* HPA,2,3,33,8  MODSET CMLA195 GENERATES DETAIL, DETAIL EXTENDED AND
*               ANALYSIS REPORTS FOR INTELLIGENT SMALL MAGNETIC TAPE
*               ERROR MESSAGES. 
* 
* 
* 580     JMO    84/02/23 
*         MODSET CORRECTS 580 PRODUCT OVERLAY TO DOUBLE THE EMPTY 
*         CHECK TIME AFTER OAM INSTRUCTION. PSR CML0493.
* 
* 
* LP1     JMO    84/02/23 
*         MODSET CORRECTS LP1 MODULE 97Z TO DISPLAY THE CORRECT WT
*         VALUE. PSR CML0492. 
* 
* 
* D88    B.D   84/02/15 
*        MODSET CORRECTS, MESSAGE DISPLAY AND PROBLEM WITH
*        HALTING AND RESTARTING, AND WHEN PROGRAM HANGS 
*        BECAUSE OF PARAMETER CONFIGURATION.
* 
* CMLINST RAS    84/02/27 
*         MODSET CMLA203 ADDS SUPPORT FOR THE DIAGNOSTIC CRP (CYBER RING
*         PORT) TO THE INSTALLATION PROCEDURES. 
* 
* 
* CMLINST RAS    84/02/08 
*         MODSET CMLA202 SETS THE I/O TIME LIMIT ON THE NOS/BE
*         INSTALLATION JOBS TO AN INFINITE VALUE.  THIS WILL PREVENT
*         THEM FROM ABORTING ON I/O TIME LIMIT AT THOSE INSTALLATIONS 
*         WHICH HAVE CHANGED THE DEFAULT VALUE FOR THIS PARAMETER.
* 
*         THIS MODSET ALSO ADDS "S=PSSTEXT" TO THE COMPASS STATEMENT
*         IN NOS JOB CML2.  THIS CORRECTS ASSEMBLY ERRORS IN MALET
*         DO TO A CHANGE IN LOCATION OF SOME SYSTEM MACROS. 
* 
* 
* CMLINST RAS    83/02/17 
*         MODSET CML0479 SUPPORTS THE CHANGE OF THE VOLUME SERIAL 
*         NUMBER (VSN) OF THE CML RELEASE TAPE FROM "CML" TO "CMLVSN".
*         THIS CHANGE TO A SIX CHARACTER VSN SHOULD ELIMINATE CONFUSION 
*         OVER THE VSN ON NOS/BE. 
* 
* 
* CMLINST RAS    84/02/28 
*         MODSET CML0497 CHANGES THE CML2 AND CML6 INSTALLATION PROCEDURES TO 
*         TO FORCE "ANSI=0" ON THE FTN5 CONTROL STATEMENT WHEN COMPILING
*         REGEN, TIO, AND MLTDOC.  THIS WILL PREVENT COMPILATION ERRORS FROM
*         OCCURRING AT INSTALLATIONS THAT HAVE CHANGED THE ANSI PARAMETER 
*         RELEASED DEFAULT VALUE IN FORTRAN 5.
* 
* 
* CMLINST RAS    84/02/03 
*         MODSET CMLA199 SUPPORTS COMPILATION OF MCCOMP AND MCDUMP FROM 
*         SOURCE INSTEAD OF LOADING THE PRE-COMPILED BINARIES FROM THE
*         CML RELEASE TAPE.  THIS MODSET ALSO INCORPORATES COMPILATION
*         OF MTPLOT INTO THE INSTALLATION PROCEDURES.  INSTALLATION 
*         JOBS/PROCEDURES AFFECTED INCLUDE BININST, CML, CML1, AND
*         CML6.  THIS MODIFICATION APPLIES TO BOTH NOS AND NOS/BE.
* 
* 
* CMLINST RAS    84/01/26 
*         MODSET CMLA198 CONVERTS THE CML INSTALLATION PROCEDURES TO
*         PERFORM ALL FORTRAN COMPILATIONS USING FTN5 INSTEAD OF FTN4.
*         THIS IS NECESSARY SINCE HPA CAN NO LONGER BE COMPILED WITH
*         FTN4.  THIS MODSET ALSO REMOVES THE "FTN4ONLY" PARAMETER
*         FROM THE INSTALLATION PROCEDURES, AND CHANGES PROCEDURE 
*         CML2 TO LOOK FOR SEPARATE MOD FILES FOR MALET, HPA, REGEN 
*         AND TIO.
* 
* 
* HISTORY PMW   84/03/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L162*. 
* 
* 
* 
* 
* FMU     JMO    84/03/06 
*         MODSET CORRECTS FMU MODULE 59 TO CALL THE CORRECT 
*         SUBMODULE. PSR CMLA205. 
* 
* 
*         PSR CMLA171 
* HPERS   REF 84/03/08
* HPA     MODSET CMLA171 IMPLEMENTS HPA FIELD LENGHTH REDUCTION EFFORTS 
* HPA1    VIA THE FOLLOWING MEASURES: 
* HPA2    1) DISCONTINUES THE SITE PERFORMANCE ANALYSIS (SPA) FEATURE.
* HPA21   INCLUDES REMOVAL OF DETAIL, ANALYSIS AND SUMMARY REPORTS AND
* HPA3    DISCONTINUANCE OF THE PUNCH FILE. 
* HPA35   2) RECLASSIFIES THE DETAILED STATUS ANALYSIS (DSA) FEATURE
* HPA4    FROM OPTIONAL TO DEFAULT.  DSA PARAMETER WILL FORCE THE PROCESS 
* HPA5    ANEW, TO ACCOMMODATE UPDATED DSA TABLES.
* HPA7    3) DISCONTINUES THE IN-LINE HPERS DECK.  CONSULT THE HPA
* HPA8    USER REFERENCE MANUAL OR CML INSTALLATION PROCEDURES FOR
*         USAGE INFORMATION.
*         4) DISCONTINUES GRAPH REPORTS (G PARAMETER).
*         5) DISCONTINUES TREND ANALYSIS (SUMMARY REPORT S=3 PARAMETER.)
*         6) DISCONTINUES SHR UNIT/CYBERLOG RECORDS AND REPORTS (SHR AND
*         EH-EDIT HISTORY PARAMETERS).
*         **CML DECKS DELETED** HPERS,HPACOM7,HPACOM2X,HPACOM4X,HPA7
* 
* 
* D44     JMO    84/03/14 
*         MODSET CORRECTS D44 DOCUMENTATION TO INCLUDE MODULES 50-53. 
*         PSR CMLA211.
* 
* 
* D44     JMO    84/03/02 
*         MODSET CORRECTS D8848 TO READ THROUGH TRACK 22. 
*         PSR CML0503.
* 
* 
* LCI      DHW  03/09/84
*          THIS CHANGE CORRECTS THE PROBLEM OF
*          MEMORY PARITY ERRORS AFTER A NAD HAS 
*          BEEN POWERED OFF AND BACK ON.
* 
* MALET     JMO    84/02/17 
*         MODSET ALLOWS MALET TO RUN ON A 721 TYPE CONSOLE. 
*         PSR CMLA207.
* 
* 
* MALET10     JMO    84/02/17 
*         MODSET ALLOWS MALET TO RUN ON A 721 TYPE CONSOLE. 
*         PSR CMLA207.
* 
* 
* MALET11     JMO    84/02/17 
*         MODSET ALLOWS MALET TO RUN ON A 721 TYPE CONSOLE. 
*         PSR CMLA207.
* 
* 
* ASSYTAG     JMO    84/03/07 
*         MODSET CORRECTS ASSYTAG FOR NOS DEFINES OF NOS23 AND ABOVE. 
*         PSR CMLA207.
* 
* 
* SKEDULR     JMO    84/03/09 
*         MODSET CORRECTS SKEDULR TO RECOGNIZE NOS23 DEFINE.
*         PSR CMLA207.
* 
* 
* CMLINST RAS    84/03/16 
*         MODSET CMLA207F ADDS NEW SYSTEM VERSION SUPPORT OF "NOS23"
*         TO THE CML INSTALLATION PROCEDURES. 
* 
* CMLINST RAS    84/03/13 
* 
*         MODSET CML0504 MAKES THE FOLLOWING CHANGES TO THE NOS CML 
*         INSTALLATION PROCEDURES.
* 
*         -ADDS AN ITEMIZE STATEMENT TO CML2 AND CML3 TO LIST 
*         THE CONTENTS OF FILES CMLBIN AND MLDBIN.
* 
*         - CHANGES THE LIBEDIT DIRECTIVE IN CML1 TO LIST ONLY ERRORS 
*         ENCOUNTERED WHEN GENERATING THE MALET DIAGNOSTIC LIBRARY. 
* 
*         - CHANGES THE LIBEDIT DIRECTIVE IN CML4 TO LIST ONLY ERRORS,
*         DIRECTIVES, AND MODIFICATIONS.
* 
*         - ADDS A CAUTION TO THE VALIDATION PARAMETER "FS" 
* 
* 
* CMLINST RAS    84/03/13 
*         MODSET CMLA209 MAKES TO FOLLOWING CHANGES TO THE NOS/BE CML 
*         INSTALLATION PROCEDURES.
* 
*         - CORRECTS DUPLICATE FILE NAME "OLDPL" IN CML3
* 
*         - REMOVES ERRONEOUS "REVERT,ABORT" FROM CML3
* 
*         - ADDS AN ITEMIZE OF CMLBIN AND MLDBIN TO CML3 AND CML4 
* 
* 
* CMLINST RAS    84/03/13 
*         MODSET CMLA208 ADDS TO THE CML INSTALLATION PROCEDURES SUPPORT
*         FOR THE 639 MAGNETIC TAPE SUBSYSTEM.
* 
* 
* HPA.HPA9  PWL  84/03/20 
*         MODSET CMLA154 CONVERTS HPA FROM FORTRAN 4 TO FORTRAN 5.
* 
* 
* CMLINST RAS    84/03/21 
*         MODSET CMLA215 SEPARATES THE LOAD SEQUENCE FOR MALET, HPA,
*         REGEN, AND TIO INTO SEPARATE LOAD SEQUENCES.  THIS CORRECTS 
*         EXECUTION ERRORS IN TIO.
* 
*         THIS MODSET ALSO CORRECTS MINOR DOCUMENTATION ERRORS. 
* 
* 
* CRP     RVS    84/03/27 
*         MISC CORRECTIONS TO EXTERNAL DOCUMENTATION
*         CMLA213A. 
* 
* 
* CMLA213BRVS    84/30/27 
*         REDUCE LINE LENGTH ON MANY DOCUMENTATION LINES IN CRP.
*         CMLA213B. 
* 
* 
* CMLA213CRVS    84/03/27 
*         MODSET CORRECTS LINE LENGTH IN CRP99 MODULES. 
*         CMLA213C. 
* 
* 
* MALET   RVS 84/03/22
* MALET10 MODSET ADDS THE CYBERPLUS AND PLATO EQUIPMENT 
*         TO THE DEVICE DISPLAY FOR MALET.
*         CMLA213 
* 
* 
*         PSR CMLA192 
* HPA34   REF 84/03/26
*         MODSET CMLA192 INCORPORATES THE CHANGE MADE BY TWIN CITY DISK 
*         TO THE PACK SERIAL NUMBER FOR ISD: THE FIELD IS REDUCED FROM
*         12 TO 6 CHARACTERS.  MODSET ALSO INCLUDES CORRECTIONS OF THE
*         READ/WRITE FLAG, SECTOR ADDRESS AND REPORT LOGIC. 
* 
* 
* FMC    B.D   84/02/03 
*        MODSET MODIFIES FHC AND FMC TEST IN ORDER TO ADD 
*        LARGE SECTOR SERIAL ENHANCEMENT TO FHC.
* 
* FMC    B.D   84/03/10 
*        MODSET CORRECTS FHC08 AND FHC09 FROM OVERFLOWING;
*        ALSO CORRECTS OVERFOLOWING OF RANDOM FILE, WHEN
*        ASSEMBING OFF LINE.
* 
*         PSR CML0471 
* HPA3    REF 84/03/26
* HPA33   MODSET CML0471 BRINGS RELIEF TO OVERFLOW PROBLEM EXPERIENCED
* HPA37   IN PROCESSING MASS STORAGE FACILITY SUBSYSTEM (MSFS) ERRORS.
*         THE REDUNDANT MESSAGE HAS BEEN ELIMINATED FOR EACH OCCURRENCE 
*         OF "TABLE FULL ... ACCUM3".  THE ANALYSIS REPORT WILL SEPARATE
*         THE VSN ACCUMULATION INTO RECOVERED AND UNRECOVERED ERRORS. 
*         ONLY THE 20 MOST ERRONEOUS VSNS WITH RECOVERED ERRORS WILL BE 
*         PRINTED (VSNS WITH LESS THAN 3 ERRORS WILL BE EXCLUDED), FOLLOWED 
*         BY A COUNT OF TOTAL NUMBER OF VSNS WITH RECOVERED ERRORS (MAX 
*         OF 217).  THE NEXT SECTION OF THE ANALYSIS REPORT WILL LIST 
*         EACH VSN THAT INCURRED AN UNRECOVERED ERROR (MAX OF 217), ALONG 
*         WITH NUMBER OF ERRORS ACCUMULATED.  THE ACCUMULATION PROCESS WILL 
*         BE SKIPPED IF ANALYSIS REPORTS ARE NOT SELECTED.
* 
* 
* MALET     JMO    84/03/27 
*         MODSET CORRECTS MALET TO ASSEMBLE CORRECTLY ON NOSBE. 
*         PSR CMLA221.
* 
* 
* SKEDULR     JMO    84/03/27 
*         MODSET CORRECTS SKEDULR TO ASSEMBLE CORRECTLY ON NOSBE. 
*         PSR CMLA219.
* 
* 
* HPA34,4,9  PWL  84/03/30
*         MODSET CMLA216 CHANGES INACTIVE STATEMENTS IN HPA34 AND 
*         HPA9 TO COMMENTS SO THEY WILL NOT APPEAR AS TRIVIAL ERRORS
*         DURING COMPILATION, CORRECTS A FORMAT SYNTEX ERROR IN HPA9, 
*         AND A SORT/MERGE WARNING MESSAGE IN HPA2. 
* 
* 
* CMLINST RAS    84/04/02 
*         MODSET CMLA117 ADDS STAND-ALONE CML INSTALLATION UTILITIES TO THE 
*         CML INSTALLATION PROCEDURES.
* 
* 
* HISTORY PMW   84/04/04
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L163*. 
* 
* 
* 
* 
* CMLINST RAS    84/03/28 
*         MODSET CMLA220 APPLIES THE FOLLOWING CORRECTIONS TO THE CML 
*         INSTALLATION PROCEDURES.
* 
*         - CORRECTS A PROBLEM OF INSUFFICIENT FIELD LENGTH TO PERFORM A
*         LIBEDIT IN NOS JOB CML1.
* 
*         - ADDS SECONDARY PROGRAM LIBRARY NAME "OPL1B" TO THE UPDATE STATEMENTS
*         IN NOS/BE JOB CML3.  THIS SUPPORTS THE CHANGE IN MLD/SBP FROM "XTEXT" 
*         PSEUDOS TO UPDATE "*CALL"S. 
* 
*         - INCREASES THE NOS/BE EXECUTION FIELD LENGTH FOR MALET TO A
*         MAXIMUM OF 25K. 
* 
*         - INCREASES THE NOS/BE EXECUTION FIELD LENGTH FOR TIO TO 53.3K. 
* 
*         - CORRECTS A MISPLACED STATEMENT INTRODUCED BY MODSET CMLA208.
* 
*         - CORRECTS MISCELLANEOUS PROBLEMS IN THE CML INSTALLATION UTILITIES 
*         (INTRODUCED BY CMLA117).
* 
*         - CORRECTS A CONFLICT BETWEEN *DEFINES FOR MLD/SBP AND HPA. 
* 
* 
* ITU    RFF    84/04/11
*        THIS MODSET ADD THE DECK ITU TO THE CML LIBRARY.  ITU IS A 
*        MALET UTILITY ROUTINE USED TO MAINTAIN THE INTELLIGENT SMALL 
*        MAGNETIC TAPE SUBSYSTEM (ISMT).
* 
* 
*         PSR CML0130 
* HPA    REF 84/04/05 
* HPA2    MODSET CML0130 ENHANCES THE REPORTING OF LCN ERRORS,
* HPA3    REFLECTING NAD COMMON CONTROLWARE WITH QMODS AND RHF
* HPA39   ENHANCEMENTS. 
*         *****CML COMMON DECK HPACOM39 IS DELETED***** 
* 
* 
* HPA,HPA2  PWL  04/06/84 
* HPA3,HPA38  MODSET CMLA225A RE-ASSIGNS RECORD TYPE 22B TO 170-8XX 
*         PROCESSOR MESSAGES, ROUTES THEM TO BE PROCESSED BY HPA310,
*         DELETES OLD CODE FOR PROCESSING THEM FROM HPA38, AND SETS 
*         EST ORDINAL FOR MICROCODE/EI ID MESSAGES TO ZERO. IT ALSO 
*         CORRECTS SORT/MERGE WARNING MESSAGES IN HPA21.
* 
* 
* HPA310  PWL  04/06/84 
*         MODSET CMLA225B ADDS DECK HPA310 TO PROCESS C170-8XX
*         PROCESSOR ERRORS. 
* 
* 
* COMHPAERT  PWL  04/09/84
*         MODSET CMLA226 UPDATES ISMT ERROR MESSAGES. 
* 
* 
* NLM     JMO    84/04/12 
*         MODSET CORRECTS NLM DOCUMENTATION IN NDT99D.
*         PSR CMLA227.
* 
* 
* MALET   MSF    82/07/23 
*         MODSET ADDS THE 16-BIT COMPILER ERROR 
*         MESSAGES, INCREASES THE MODULE BUFFER, CODE 
*         BUFFER, AND THE DATA BUFFER IN MALET. 
* 
* 
* MALET10 MSF    82/10/07 
*         MODSET ADDS UPDATE DISPLAY ROUTINE UPPU16 TO
*         MALET10 FOR 16-BIT MALET. 
* 
* 
* MALET11 MSF    82/11/01 
*         MODSET CHANGES THE ASSIGN DIRECTIVE TO ALSO WRITE THE 
*         DISK PACK SERIAL NUMBER INTO WORD FOUR OF THE MESSAGE 
*         BUFFER FOR 16-BIT MALET.
* 
* 
* MALET12 MSF    82/10/07 
*         MODSET ADDS PPUMSG16 ROUTINE TO MALET12 FOR 
*         16-BIT MALET. 
* 
* 
* MALET20 MSF    82/07/16 
*         MODSET ADDS THE MALET COMPILE 16-BIT COMPILER 
*         SUPPORT TO MALET20. 
* 
* 
* MLD     MSF    82/10/07 
*         MODSET CHANGES THE DISPLAY BUFFER LENGTH AND
*         THE CHECKPOINT BUFFER LENGTH FOR 16-BIT MALET.
* 
* 
* SBP     MSF    82/11/29 
*         MODSET INCREASES BUFFER LENGTHS FOR 16-BIT MALET. 
* 
* 
* MALET     JMO    84/04/11 
*         MODSET CORRECTS MALET TO HANDLE SE WHEN RUNNING MALET VIA A 
*         PROC WITH DIRECTIVES ON ALTERNATE INPUT FILE. PSR CML0535.
* 
* 
*         PSR CML0527 
* HPA37   REF 84/04/12
*         MODSET CML0527 CORRECTS THE COUNTING OF TOTAL MOUNTS IN THE 
*         MSS UNIT ANALYSIS REPORT. 
* 
* 
* FMC     JMO    84/04/12 
*         MODSET CORRECTS FMC TO NOT EXECUTE MODULE 32 IF 844 OPTION
*         INSTALLED BECAUSE OF FALSE ERRORS PRODUCED. PSR CML0474.
* 
* 
* MALET11     JMO    84/04/25 
*         MODSET CORRECTS MALET NOT TO GET ASSEMBLY ERRORS ON NOSBE.
*         PSR CMLA233.
* 
* 
*         PSR CMLA234A
* HPA2    REF 84/04/30
*         MODSET CMLA234A INSURES LCN ARRAY LIMIT WILL NOT BE EXCEEDED
*         BY MULTITUDE OF MLTF ERRORS FOR THE SAME SAMPLE TIME. 
* 
* 
*         PSR CMLA234B
* HPA39   REF 84/04/30
*         MODSET CMLA234B REFORMATS THE PRINTING OF LCN CHANNEL FROM
*         HEX TO OCTAL. 
* 
* 
* HISTORY PMW   84/05/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L164*. 
* 
* 
* 
* 
*         PSR CML0470 
* HPA3    REF 84/05/07
* HPA37   MODSET CML0470 CORRECTS THE PROCESSING OF MSS ERRORS SO THAT
*         THEY DO NOT GET OUT OF SYNC, THUS PROVIDING INCORRECT ERROR 
*         INFORMATION (DENOTED BY JOB NAME OF "CONTINU" AND UNSORTED
*         HH.MM.SS) AND EVENTUALLY CAUSING AN ABORT.  MODSET CML0470
*         ALSO ENHANCES THE MSS DETAIL REPORT BY REMOVING THE DATE FROM 
*         THE HEADER AND INSERTING IT IN THE DETAIL LINE, THEREBY 
*         ELIMINATING THE NEED OF A NEW MESSGE HEADER FOR EACH DATE 
*         CHANGE, EFFECTING A SAVINGS IN REPORT LENGTH.  (PROBLEM CAUSED
*         BY NORM, AND MIRRORED BY INABILITY OF HPA/MSS RECORDS TO COPE 
*         WITH RECORDS OUT OF SYNC.  NORM PROBLEM WILL BE CORRECTED IN
*         NOS 2.3, NORM L607, BY MODSET CML0481.) 
* 
* 
* FMC     JMO    84/05/04 
*         MODSET CORRECTS FMC TO MAKE SEPERATE DECKS ON FMC AND FHC.
*         PSR CMLA166.
* 
* 
* FHC     JMO    84/05/08 
*         MODSET ADDS DECK FHC AFTER SPLITTING FMC/FHC. 
*         PSR CMLA166.
* 
* 
* MALET12     JMO    84/05/23 
*         MODSET CORRECTS MALET SO SCRATCH FILES CAN BE SAVED.
*         PSR CML0561.
* 
* 
*         PSR CMLA240 
* HPA34   REF 84/05/23
*         MODSET CMLA240 CORRECTS PRINTING FORMAT ERROR CAUSED BY FTN5
*         CONVERSION FOR THE FOLLOWING DISK ERRORS: FUNCTION TIMEOUT, 
*         CONTROLLER STOP AND RAM PARITY. 
* 
* 
*         PSR CML0554 
* HPA34   REF 84/05/30
*         MODSET CML0554 CORRECTS THE 819 CYLINDER ADDRESS.  IT INCLUDES
*         THE MOST SIGNIFICANT BIT (BIT 10) WHEN REPORTING THE CYLINDER 
*         IN THE 819 DETAIL REPORTS.
* 
* 
* HISTORY PMW   84/MM/04
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L165*. 
* 
* 
* 
* 
* FSD     JMO    84/05/31 
*         MODSET ADDS MODULE 11 DEADMAN TIMER TEST. 
*         PSR CML0510.
* 
* 
* FSD     JMO    84/06/08 
*         MODSET CORRECTS FSD10 TO NOT HOLD THE CONTROL MODULE
*         RESERVED. PSR MSLA278.
* 
* 
* FFU     JMO    84/06/07 
*         MODSET CORRECTS FFU65 TO NOT GET SYNTAX ERRORS ON *HEX. 
*         PSR CMLA247.
* 
* 
*         PSR CMLO517 
* HPA3    REF 84/06/14
*         MODSET CMLO517 ENABLES THE PROCESSING OF LCN ERROR LOG RECORDS
*         FROM NOS/BE NORMS.  THESE RECORDS WERE BEING SWALLOWED IN HPA3
*         (AFTER BEING SORTED) BY AN ANCIENT (HPA402JLP/1979/CL110) ITEM
*         EDITOR FIX FOR SITE MANAGEMENT, WHICH IS NO LONGER VALID. 
*         IF USING A PRE-CML 161 RELEASE, SUBSTITUTE THE FOLLOWING CODE:  
*         *DELETE HPA402JLP.6,7 
* 
* 
*         PSR CMLA235 
* HPA2    REF 84/06/20
* HPA3    MODSET CMLA235 CORRECTS SEVERAL LCN REPORT DISCREPANCIES.  THE
* HPA39   ALGORITHM FOR DETERMINING AN LCN TRUNK ERROR LOG MESSAGE FROM 
*         TCU STATUS WORDS I AND II HAS BEEN EXPANDED TO PREVENT A REMOTE 
*         NAD CONTROLWARE PROBLEM FROM BEING INCORRECTLY IDENTIFIED AS A
*         LOCAL TCI/TCU PROBLEM.  ADDITIONALLY, VARIOUS HEADER LABELS 
*         HAVE BEEN ENHANCED, AS FOLLOWS: 
*         1) TCU ADR CHANGED TO TCU EADR (TCU ERROR ADDRESS); 
*         2) TCU LINE CHANGED TO INTR LINE; 
*         3) TCU ENBL/CNCT IDENTIFIED WITH CORRESPONDING BIT. 
*         FINALLY, MODSET GIVES VISIBILITY TO INVALID FUNCTION CODES
*         PASSED FROM THE OS FOR DEVICE INTERFACE AND PATH ERRORS 
*         DETECTED BY LOCAL HOST SOFTWARE, BY ALLOWING THE PRINTING OF
*         THE UPPER-MOST INVALID BITS, UPON OS ANALYSTS REQUEST.
* 
* 
* HPA34   PWL  06/21/84 
*         MODSET CML0552 BLANK FILLS ACTUAL UNIT NUMBER IN 819 DETAIL 
*         REPORT WHEN NO BITS ARE SET IN THE CONTROLLER STATUS TO 
*         INDICATE IT IS NOT AVAILABLE. 
* 
* 
* ITU       RFF     06/26/84
*           THIS MODSET ADDS A MASTER CLEAR FUNCTION TO THE BEGINNING 
*           OF ALL MODULES AND CORRECTS THE FUNCTION TIMEOUT ERROR
*           BEING REPORTED IN MODULES ITU11 AND ITU13 WHEN THE ISMT 
*           TRYING TO CONNECT TO THE STU. 
* 
* 
* HISTORY PMW   84/MM/02
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L166*. 
* 
* 
* 
* 
*         PSR CML0584 
* HPA35   REF 84/07/13
* HPA38   MODSET CML0584 CORRECTS THE PAGE LINE COUNTS FOR MR SECDED AND
*         2550 NPU DETAIL REPORTS.
* 
* 
* D88     JMO    84/07/17 
*         MODSET CORRECTS D8815 TO INDICATE THE CORRECT HEAD ON 
*         GET SERIAL COMMAND. PSR CML0569.
* 
* 
* CMLINST     JMO    84/07/24 
*         MODSET CORRECTS CMLINST DOCUMENTATION TO BCXMODS. 
*         PSR CMLA258.
* 
* 
* HPA3,33  PWL  06/28/84
*         MODSET CMLA254 REPORTS ISMT CUMULATIVE STATUS MESSAGES. 
* 
* 
* HPA3,35   PWL     07/18/84
*         MODSET CMLA250 REPORTS 2550 CE ERROR MESSAGES 37 (NO
*         RESPONSE FROM TERMINAL), 38 (BAD-UNEXPECTED RESPONSE) 
*         AND 39 (WORKSTATION IGNORING WAIT-A-BIT) FOR THE HASP-
*         TIP.
* 
* HPA35   PWL  07/20/84 
*         MODSET CMLA183 REPORTS ADDITIONAL INFORMATION IN
*         2550 LINE STATISTICS. 
* 
* 
* HPA3    PWL  84/07/26 
*         MODSET CML0586 CORRECTS SUB-HEADING FOR MULTI-HOST
*         2550 STATISTICS MESSAGE ANALYSIS REPORT.
* 
* 
* CMLINST     JMO    84/07/31 
*         MODSET CORRECTS CMLINST TO HANDLE RT3.
*         PSR CML0544.
* 
* 
* RT3     JMO    84/08/02 
*         MODSET ADDS DECK RT3 TO CML FOR 6673/6674 SUPPORT.
*         PSR CML0544.
* 
* 
* MALET     JMO    84/05/04 
*         MODSET CORRECTS PARAM DISPLAY TO DISPLAY ONLY 4 DIGITS. 
*         PSR CMLA266.
* 
* 
* MALET12     JMO    84/07/31 
*         MODSET CORRECTS MALET12 NOT TO HANG MLD ON SYSREAD. 
*         PSR CMLA266.
* 
* 
* MALET20     JMO    84/05/02 
*         MODSET CORRECTS MALET COMP TO NOT ALLOW H AND 3H DATA 
*         IN 16 BIT MODE. PSR CMLA266.
* 
* 
* LCO     JMO    84/07/24 
*         MODSET CORRECTS LCN PRODUCT OVERLAY NOT TO HANG MLD ON
*         A HARDWARE PROBLEM. PSR CML0594.
* 
* 
* CMLINST     JMO    84/07/30 
*         MODSET CORRECTS CML INSTALL PROCS FOR MTPLOT FHC AND
*         LCN TESTS. PSR CMLA264. 
* 
* 
* HISTORY PMW   84/08/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L167*. 
* 
* 
* 
* 
* HPA36   PWL  84/07/28 
*         MODSET CMLA242 DISTINGUISHES AN 875CR FROM AN 875 WITH A
*         DIFFERENT DETAIL REPORT SUB-HEADER. 
* 
* 
* D44     JMO    84/07/18 
*         MODSET CORRECTS D44 ERROR PROCESSORS TO DISTINGUISH 
*         WRITE VERIFY FROM P.O. ABORT. PSR CML0543.
* 
* 
* MALET     JMO    84/08/16 
*         MODSET CORRECTS PARAMETER DISPLAY FOR NOS 2.3.
*         PSR CMLA278.
* 
* 
* MLD     JMO    84/08/14 
*         MODSET CORRECTS MLD TO ASSEMBLE LARGE SECTOR FOR NOSBE. 
*         ALSO CHANGES THE PERMANENT DEFINES FOR 66X,67X AND 844. 
*         PSR CMLA277.
* 
* 
* CMLINST     JMO    84/08/15 
*         MODSET CORRECTS CML INSTALL PROCS FOR FHC AND NOSBE.
*         PSR CMLA277.
* 
* 
*         PSR CMLA265 
* HPA33   REF 84/08/07
* HPA34   MODSET CMLA265 SUPPRESSES EXTRANEOUS REPORT SUB-HEADER
*         INFORMATION WHEN PAGE OVERFLOW OCCURS IN THE TAPE ANALYSIS
*         REPORT.  IT ALSO CORRECTS ERROR CODE CHECK FOR SUMMATION
*         OF ISD ERROR-FREE DIAGNOSTICS: FROM DECIMAL TO OCTAL. 
* 
* 
* HPA3,38 PWL  84/08/03 
*         MODSET CMLA268
*         1) REPORTS ONLY UNCORRECTED MEMORY ERRORS BY
*         ADDRESS AND SEPARATES POTENTIAL HARD SECDED ERRORS AND
*         POTENTIAL TRANSIENT SECDED ERRORS IN ANALYSIS REPORT. 
*         2) FLAGS POSSIBLE OVERFLOW CONDITIONS OF MORE THAN 77B COUNTS 
*         PER UNIQUE ADDRESS AND MORE THAN TEN UNIQUE ADDRESS ERRORS
*         PER HOUR. 
*         3) BLANKS OUT CH-EQ-UN FIELDS IN ANALYSIS REPORTS FOR PRO-
*         CESSOR ERRORS (RT=22B). 
*         4) ELIMINATES THE PRINTING OF THE CONTENTS OF REGISTERS 10, 
*         12, AND 20 IN THE DETAIL EXTENDED MEMORY REPORT.
*         5) PRINTS "*** STATUS SUMMARY REGISTER INVALID" AND THE CON-
*         TENTS OF ALL REGISTERS IN THE MEMORY REPORT WHEN NEITHER THE
*         COR OR THE UNC BIT IS SET IN THE SS REGISTER. 
* 
* 
* HPA38   PWL  05/04/84 
* HPA310  MODSET CMLA244 REPORTS M3 AND P3 COST REDUCED MAINTENANCE 
*         REGISTER MESSAGES, AND NEW M3CR SECDED BML MESSAGES.
* 
* 
* MALET     JMO    84/08/20 
*         MODSET CORRECTS MALET TO HOLD PARAMETERS BETWEEN RUNS.
*         PSR CMLA280.
* 
* 
* MALET10     JMO    84/08/20 
*         MODSET CORRECTS MALET10 TO HOLD PARAMETERS BETWEEN RUNS.
*         PSR CMLA280.
* 
* 
*         PSR CMLA284 
* HPA34   REF 84/08/21
*         MODSET CMLA284 CORRECTS THE FSC DISK 80 COLUMN DETAIL 
*         REPORT PRINT FORMAT ERROR WHICH RESULTED FROM FTN5
*         CONVERSION. 
* 
* 
* CMLINST     JMO    84/08/27 
*         MODSET CORRECTS CMLINST TO RFL UP AUTOMATICALLY IF NOS2 
*         FOR MLD/SBP IN CML3. PSR CMLA282. 
* 
* 
*         PSR CMLA285 
* HPA39   REF 84/08/24
*         MODSET CMLA285 CORRECTS THE ALGORITHM FOR DETERMINING 
*         THE LCN TRUNK ERROR LOG MESSAGE.  THE ALGORITHM IS
*         CORRECTED TO RECOGNIZE A MODE STREAM PROBLEM AS REMOTE. 
* 
* 
*         PSR CMLA288 
*         REF 84/09/05
* COMHPAERT 
*         MODSET CMLA288 CORRECTS THE SYMPTOM CODE PRINTED FOR 885 DSA
*         R/U DATA CKWD ERR HD 0 (SC214).  IT WAS BEING INCORRECTLY PRINTED 
*         AS SYMPTOM CODE 207 (R/U ADDR CKWD ERR HD O). 
* 
* 
* DSPLOT  GLG    84/08/29.
*         MODSET ADDS PROGRAM DSPLOT TO CML 
* 
* 
* DKDATA  GLG    84/08/29.
*         MODSET ADDS PROGRAM DKDATA TO CML 
* 
* 
* FTP     JMO    84/08/03 
*         MODSET CORRECTS FTP TO HANDLE 8.5, 11 AND 12 INCH 
*         PAPER FOR PFC TYPES. PSR CML0255. 
* 
* 
* 580     JMO    84/08/01 
*         MODSET CORRECTS FTP TO RUN DIFFERENT SIZE PAPER.
*         PSR CML0255.
* 
* 
* HPA36   PWL  09/04/84 
*         MODSET CML0597
*         1) DELETES "MESSAGE" FROM DETAIL REPORT SUBHEADER FOR 
*         SECDED ERROR COUNT MESSAGES.
*         2) PRINTS "SECDED ERROR COUNT" UNDER MESSAGE IN THE 
*         ANALYSIS REPORT.
*         3) CHANGES SECDED ERROR COUNTS TO DECIMAL.
*         4) PRINTS SINGLE, DOUBLE, MULTIPLE OR SYNDROME ERROR
*         TYPES FOR SECDED ERROR COUNT MESSAGES.
*         5) BLANKS OUT FAILING BIT FOR DOUBLE, MULTIPLE SECDED 
*         ERRORS. 
*         6) BLANKS OUT FAILING BIT WHEN SYNDROME CODE IS ZERO. 
*         7) BY-PASSES SEF RECORDS WITH RT=12B AND DT NOT EQUAL TO SR.
*         8) CORRECTS DATA ACCUMULATION FOR CY176 SCR MESSAGES. 
* 
* 
* HISTORY PMW   84/09/10
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L168*. 
* 
* 
* 
* 
* MTPLOT     JMO    84/09/14
*         MODSET CORRECTS TYPO IN REPORT 1 ON MTPLOT. 
*         PSR CML0613.
* 
* 
* CMLINST     JMO    84/09/04 
*         MODSET ADDS SUPPORT TO CMLINST FOR DSPLOT.
*         PSR CMLA289.
* 
* 
* HPA36    PWL  84/09/18
*          MODSET CMLA295 REINSTATES CODE TO PROCESS NOS/BE SCR DATA
*          CORRECTLY. (CODE WAS REMOVED TO ALLOW NOS C170/C176 SCR
*          DATA TO BE PROCESSED WITHOUT ERROR.) 
* 
* 
*         PSR CMLA286 
* HPA     REF 84/09/19
* HPA3    MODSET CMLA286 SUPPORTS CHANNEL PARITY ERRORS DETECTED BY 
* HPA32   AN IOU INSTRUCTION FOR 180-XXX DEVICES (EXCLUDING 865/875). 
*         NOS/NORM PROVIDED CH PE SUPPORT FOR 844/885/FSC/ISD/DEMA/PFMD 
*         DISKS AT 2.3; SUPPORT WILL BE PROVIDED FOR TAPES AND UNIT 
*         RECORD EQUIPMENT AT 2.3+.  (NOS SUPPORT PROVIDED IN CONJUNC-
*         TION WITH TRANSPARENCY.)  HPA PROVIDES DETAIL, ANALYSIS AND 
*         SUMMARY REPORTS FOR DISK, TAPE AND UNIT RECORD CHANNEL ERRORS.
* 
* 
*         PSR CMLA269 
* HPA     REF 84/09/19
* HPA3    MODSET CMLA269 SUPPORTS BATCHIO TRANSPARENCY. 
* HPA32 
* 
* 
* LCN1     JMO    84/08/29
*         MODSET CORRECTS LCN PRODUCT OVERLAY NOT TO REWIND ON A LOAD 
*         COMMAND. PSR CMLA290. 
* 
* 
* NLM     JMO    84/08/28 
*         MODSET CORRECTS NOT TO HANG ON SYSTEM COMMANDS. 
*         PSR CMLA290.
* 
* 
* FLM     JMO    84/08/28 
*         MODSET CORRECTS FLM NOT TO HANG ON SYSTEM COMMANDS. 
*         PSR CMLA290.
* 
* 
* MALET10     JMO    84/09/19 
*         MODSET CORRECTS MALET TO PASS TCU ENABLES CORRECTLY.
*         PSR CMLA290.
* 
* 
*         PSR CMLA260 
* HPA39   REF 84/09/19
*         MODSET CMLA260 SUPPORTS THE LCN NAD ERROR LOG UNAVAILABLE 
*         FEATURE, MADE AVAILABLE BY RHF IN NOS 2.3+. 
* 
* 
* NLM     JMO    84/09/25 
*         MODSET CORRECTS NLM 99 MODULES TO BE LESS CONFUSING.
*         PSR CMLA297.
* 
* 
* CMLINST     JMO    84/09/24 
*         MODSET CORRECTS PROBLEMS IN CMLINST.
*         PSR CML0620.
* 
* 
* 580     JMO    84/09/26 
*         MODSET CORRECTS 580 NOT TO GET ASSEMBLY ERRORS ON NOSBE.
*         PSR CMLA300.
* 
* 
*         PSR CMLA303 
* HPA33   REF 84/09/28
* COMHPA- MODSET CMLA303 SUPPORTS ADDITIONAL MAGNET ERROR CODES 
* ERT     FOR EXTENDED TAPE ERROR RECOVERY. 
* 
* ******************** HPA COMMON DECK - COMHPAERT *******************
* 
*         PSR CMLA301 
* HPA21   REF 84/09/27
* HPA3    MODSET CMLA301 ELIMINATES CHANNEL PARITY ERRORS FROM THE
* HPA32   INTERVENTION REPORT WHEN USING THE IN-LINE SORT, HPSORT.
* HPA5
* 
* 
* HISTORY LJC   84/10/01
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L169*. 
* 
* 
* 
* 
* HPA3    PWL  84/10/02 
* HPA310  MODSET CML0621 ADDS CORRECTED AND UNCORRECTED PROCESSOR 
*         ERRORS IN THE SUMMARY REPORT AND UNIT ANALYSIS REPORT.
*         IT ALSO ADDS THE REPORTING OF 840 PROCESSOR MESSAGES. 
* 
* 
* FMDFT     JMO    84/09/28 
*         MODSET CORRECTS FSC TESTS TO NOT GET FALSE ERROR ON GENERAL 
*         STATUS DUE TO FMDFT PO. PSR CMLA308.
* 
* 
* FLM     JMO    84/09/28 
*         MODSET CORRECTS FLM 99 MODULES TO COMPILE SOURCE. 
*         PSR CMLA310.
* 
* 
* HPA38   PWL  84/09/27 
*         MODSET CMLA304 FLAGS M1/M1CR/M3CR SECDED REPORT FIELDS
*         THAT ARE NOT CORRECT BECAUSE NOS DOES NOT LOG THE RIGHT 
*         ADDRESS AND SYNDROME BITS. IT ALSO ELIMINATES THESE 
*         SECDED SUMMARY REPORTS IN THE ANALYSIS REPORT.
* 
* 
* LCN1     JMO    84/10/05
*         MODSET CORRECTS LCN PRODUCT OVERLAY TO HANDLE 4X PPUS 
*         ON A 205B FUNCTION. PSR CMLA313.
* 
* 
*         PSR CMLA311 
* HPA32   REF 84/10/05
*         MODSET CMLA311 BYPASSES CYBERAMA MESSAGES GENERATED BY
*         OLDER VERSIONS OF THE NORMALIZER, NORM. 
* 
* 
*         PSR CMLA271 
* HPA5    REF 84/10/08
*         MODSET CMLA271 INHIBITS AN EXTRA PAGE HEADER WHEN PAGE
*         OVERFLOW OCCURS IN THE ERROR LOG SUMMARY REPORT.
* 
* 
*         PSR CMLA272 
* HPA5    REF 84/10/08
*         MODSET CMLA272 INHIBITS AN EXTRA HEADER FROM APPEARING
*         IN THE ERROR LOG SUMMARY REPORT.  IT CHANGES THE LOGIC
*         TO CHECK FOR PAGE OVERFLOW BEFORE PRINTING THE DATA 
*         RATHER THAN AFTERWARDS. 
* 
* 
* D88     JMO    84/10/10 
*         MODSET CORRECTS D8817 TO NOT GET FALSE ERRORS ON A FLAWED 
*         TRACK WHILE READING PRE-WRITTEN DATA. PSR CML0628.
* 
* 
* FMD     JMO    84/10/04 
*         MODSET CORRECTS FMD40 TO DOUBLE THE NUMBER OF TIMES 
*         TO CHECK FOR TRACK CROSSINGS. PSR CML0625.
* 
* 
*         PSR CML0626 
* HPA36   REF 84/10/15
*         MODSET CML0626 ALLOWS LARGE SECDED COUNTS TO BE PRINTED 
*         IN THE CY170/176 SCR AND 865/875 MR ANALSIS REPORTS.
* 
* 
* LCN     JMO    84/10/12 
*         MODSET CORRECTS LCN TO RUN REMOTELY WITH EITHER QMOD OR 
*         NON QMOD CONTROLWARE. PSR CMLA316.
* 
* 
*         PSR CMLA321 
* HPA33   REF 84/10/18
*         MODSET CMLA321 CORRECTS THE FORMAT FOR 80 COLUMN DETAIL 
*         REPORTS FOR 66X/67X CUMULATIVE STATUS.  A MINOR ERROR 
*         RESULTED FROM THE FTN5 CONVERSION ( MODSET CMLA154).
* 
* 
* MALET     JMO    84/08/08 
*         MODSET ADDS DISK IDLE SUPPORT TO MALET. 
*         PSR CMLA246.
* 
* 
* MALET11     JMO    84/08/08 
*         MODSET ADDS DISK IDLE SUPPORT TO MALET. 
*         PSR CMLA246.
* 
* 
* CMLINST     JMO    84/10/31 
*         MODSET CORRECTS CMLINST TO DO L=1 IN THE UPDATE FOR CMLINST 
*         MODS. PSR CML0632.
* 
* 
* HISTORY PMW   84/11/05
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L170*. 
* 
* 
* 
* 
* 67X     JMO    84/10/31 
*         MODSET CORRECTS 67X PRODUCT OVERLAY TO DO A SHORT WRITE 
*         IN PACKED MODE. PSR CML0640.
* 
* 
* T7X     JMO    84/10/31 
*         MODSET CORRECTS T7X MODULES 03, 10, 11, 46, AND 57 TO NOT GET 
*         FALSE ERRORS ON A SHORT WRITE. PSR CML0640. 
* 
* 
* F7X     JMO    84/10/31 
*         MODSET CORRECTS F7X MODULES  13, AND 20 TO NOT GET
*         FALSE ERRORS ON A SHORT WRITE. PSR CML0640. 
* 
* 
* SKEDULR     JMO    84/11/09 
*         MODSET CORRECTS SKEDULR MODSET CML0176 TO STORE PREVIOUS DAY. 
*         PSR CMLA324.
* 
* 
* D88     JMO    84/11/05 
*         MODSET ADDS MODULE 47 RANDOM READ CHECKWORD TEST. 
*         PSR CML0617.
* 
* 
* CMLINST     JMO    84/11/14 
*         MODSET CORRECTS CMLINST TYPO FOR NOSBE BUILD OF MLDBIN. 
*         PSR CML0643.
* 
* 
* FMU     JMO    84/11/14 
*         MODSET CORRECTS FMU MODULES 61 THRU 77 TO NOT ERROR WITH DOES NOT 
*         SUPPORT DEVICE CODE BECAUSE OF TWO 98G MODULES. PSR CMLA335.
* 
* 
* MALET20     JMO    84/11/27 
*         MODSET CORRECTS MALET 20 TO CHECK FOR BINARY OVERFLOW.
*         PSR CMLA341.
* 
* 
* FMC     JMO    84/11/15 
*         MODSET ADDS MODULES 08B AND 09A TO FMC FOR PARITY CHECKING ON 
*         AN 810, 815, 825, OR 830 TYPE MAINFRAME. PSR MSL0405. 
* 
* 
* FHC     JMO    84/11/15 
*         MODSET ADDS MODULES 08B AND 09A TO FHC FOR PARITY CHECKING ON 
*         AN 810, 815, 825, OR 830 TYPE MAINFRAME. PSR MSL0405. 
* 
* 
* MALET10     JMO    84/11/28 
*         MODSET ADDS DEVICE CODE 115 FOR 895 DISK. 
*         PSR CMLA342.
* 
* 
* MALET11     JMO    84/11/28 
*         MODSET ADDS DEVICE CODE 115 FOR 895 DISK. 
*         PSR CMLA342B. 
* 
* 
*         PSR CMLA320 
* HPA     REF 84/11/28
* HPA3    MODSET CMLA320 SUPPORTS 7165/895 DISK ERRORS AND USAGE
* HPA32   INFORMATION.  IT PROVIDES REPORTS FOR 895 MESSAGES FROM 
* HPA34   THE SEF FILE GENERATED BY NORM/NOS. 
* HPA37 
* 
* 
* HISTORY PMW   84/12/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L171*. 
* 
* 
* 
* 
* MALET     JMO    84/12/06 
*         MODSET CORRECTS MALET MSGE50 TO INCLUDE DC MISSING. 
*         PSR CML0654.
* 
* 
* MALET11     JMO    84/12/06 
*         MODSET CORRECTS MALET11 TO HANDLE RMS DC BETWEEN 110 AND 117. 
*         PSR CML0654.
* 
* 
* CMLINST     JMO    84/12/05 
*         MODSET ADDS 895 SUPPORT TO CMLINST PROCEDURES.
*         PSR CMLA345.
* 
* 
* MALET10     JMO    84/12/10 
*         MODSET ADDS DEVICE CODE FOR CCC/MASSTOR TO MALET. 
*         PSR CMLA348.
* 
* 
* HPA,HPA2  PWL  84/12/12 
* HPA3,HPA32  MODSET CMLA298 GENERATES DETAIL, EXTENDED DETAIL, 
* HPA37,HPA8  ANALYSIS, SUMMARY AND MEDIA SUMMARY REPORTS FOR 
* HPA9        MASSTOR CCC AND 7990 ERROR MESSAGES AND 7990 USAGE
*             MESSAGES. 
* 
* 
* LOW     JMO    84/12/06 
*         MODSET CORRECTS LOW TO GIVE ERROR CODE 4010 RATHER THAN 4024
*         ON AN EQUIPMENT FUNCTION. PSR CML0652.
* 
* 
* FMU     JMO    84/12/07 
*         MODSET CORRECTS FMU TO EXIT AFTER ARCHIVING FACTORY TWICE.
*         PSR CMLA344.
* 
* 
* TIO     JMO    84/12/12 
*         MODSET CORRECTS TIO NOT TO GET ERROR 68 AFTER START OF SEQ
*         PASS. PSR CMLA347.
* 
* 
* CMLINST     JMO    84/12/17 
*         MODSET CORRECTS CMLINST FOR NLM CHANGES TO 99 MODULES.
*         PSR CMLA351.
* 
* 
* DFU    B.D    84/11/30
*     DFU IS A FORMATTING UTILITY PROGRAM FOR 895 DEVICE. 
* 
* 
*         PSR CML0637 
* HPA     REF 84/12/10
* HPA2    MODSET CML0637 PROVIDES A VARIETY OF MODIFICATIONS TO 
* HPA3    LCN REPORTS, AS FOLLOWS:  
* HPA34   1) RENAMES STATUS WORDS I AND II, FROM TCU TO TCI STATUS; 
* HPA39   2) CHANGES CY7000 DEVICE INTERFACE NUMBER, PRE-QMODS, 111 TO 110; 
*         3) SUPPORTS DEADCODE FOR DEVICE INTERFACE ERRORS DETECTED BY HOST;
*         4) ENABLES CONNECTION ERRORS DETECTED BY LOCAL HOST;
*         5) INTERPRETS THE HARDWARE STATUS BITS FOR DI AND PATH ERRORS.
*         6) MASSAGES THE ALGORITHM FOR TRUNK ERROR LOG MSGS, TYPES 1 & 2.
* 
* 
* FMU     JMO    84/12/18 
*         MODSET CORRECTS FMU FORMAT ROUTINES TO SKIP CYL 1511 TRACK
*         0 AND 1 CORRECTLY. PSR CML0660. 
* 
* 
* CLM    DHW    84/12/28
*        CLM IS A LOADER/MONITOR FOR THE  CYBER 
*        CHANNEL COUPLER(CCC).  IT IS A COPY OF 
*        FSM WITH CODE ADDED TO INVOLKE THE IN- 
*        LINE DIAGNOSTICS  IN THE  CCC PRIOR TO 
*        LOADING A TEST TO BE EXECUTED. 
* 
* 
* CCM    DHW    84/12/28
*        CCM IS A MEMORY TEST FOR THE CYBER CHANNEL 
*        COUPLER(CCC).  IT IS A COPY OF THE FSM DI- 
*        AGNOSTIC FOR THE FSC.  CODE IS ADDED TO A- 
*        VOIDE WRITING INTO LOCATIONS 1E00 TO  1FFF 
*        OF MEMORY, AS  THEY ARE  USE FOR  HARDWARE 
*        TRACING OF FUNCTIONS.
* 
* 
* HISTORY PMW   85/01/09
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L172*. 
* 
* 
* 
* 
* CMLINST     JMO    85/01/09 
*         MODSET CORRECTS CMLINST FOR 895 MISSING PARAMETER.
*         PSR CMLA355.
* 
* 
* CMLINST     JMO    85/01/10 
*         MODSET CORRECTS CMLINST FOR CLM LAST MODULE BEING 99. 
*         PSR CMLA356.
* 
* 
* HPA3    PWL  84/12/14 
* HPA38   MODSET CMLA331 REMOVES IOU STATUS REGISTER FROM THE 
*         DETAIL REPORT SUBHEADING BECAUSE IT CHANGES OFTEN 
*         WITH EACH ERROR MESSAGE. IT ALSO ENABLES HPA TO PRO-
*         CESS IOU MESSAGES WITH EITHER 2 OR 3 SEF RECORD.
* 
* 
* HPA38   PWL  12/18/84 
* HPA310  MODSET CMLA352 MODIFIES HPA TO REPORT 810-860 SECDED
*         MESSAGES IN THE NEW FORMAT: 36/ADDRESS, 12/SYNDROME,
*         RIGHT JUSTIFIED AND LAST 2 BITS/COUNT.
*         IT ALSO 
*         1) CORRECTS THE LINE COUNT FOR MAINTENANCE REGISTER REPORTS,
*         2) CHANGES MESSAGE 'CRITICAL' TO 'DEADSTART ERROR LOG', 
*         3) REPORTS DUAL PROCESSOR ERRORS FOR S3 AND S3CR, 
*         4) REPORTS PAK LOCATION FOR S1, S1CR AND M3CR MEMORY ERRORS 
*            WITHOUT FAILING BIT IDENTIFICATION,
*         5) FLAGS EDD MESSAGES.
* 
* 
*         PSR CMLA358 
* HPA22   REF 85/01/10
* HPA34   MODSET CMLAHPA SUPPORTS 895/1XM CHANGES MADE BY THE OS TO:  
*         1) RECOGNIZE A MEDIA DEFECT (ERROR CODE = 157B);
*         2) REPORT ISOLATION GENERAL STATUS TAKEN AFTER A ZERO-WORD
*         AUTOLOAD. 
* 
* 
* FMC     JMO    85/01/11 
*         MODSET CORRECTS FMC02 TO DISPLAY THE CORRECT CW REV LEVEL.
*         PSR CMLA360.
* 
* 
* FHC     JMO    85/01/11 
*         MODSET CORRECTS FHC02 TO DISPLAY THE CORRECT CW REV LEVEL.
*         PSR CMLA360.
* 
* 
*         B.D    85/1/14
*         MODSET WILL REDUCE THE STATUS DISPLAY AND ALSO
*         CORRECTS THE DOCUMENTATION TO REFLECT THE CODE. 
* 
* 
* MLD     JMO    85/01/18 
*         MODSET CORRECTS PRODUCT OVERLAYS SO ACCESS LEVEL FOR READ 
*         ANYWHERE IS CORRECT. PSR CMLA364. 
* 
* 
* D88     JMO    85/01/17 
*         MODSET CORRECTS D88/DH8/DL8 MODULE 99 FOR ACCESS LEVELS.
*         PSR CMLA364.
* 
* 
* FMC     JMO    85/01/23 
*         MODSET CORRECTS FMC DOCUMENTATION FOR RUNNING PARITY MODULES. 
*         PSR MSLA343.
* 
* 
* FHC     JMO    85/01/23 
*         MODSET CORRECTS FHC DOCUMENTATION FOR RUNNING PARITY MODULES. 
*         PSR MSLA343.
* 
* 
*         PSR CMLA368 
* HPA32   REF 85/01/23
*         MODSET CMLA368 PROVIDES SUPPORT FOR NIP (NON-IMPACT PRINTER)
*         ERRORS AND CONTROLWARE MESSAGES.
* 
* 
* D88     JMO    84/12/20 
*         MODSET CORRECTS DH825 PATTERN 1 TO SELECT ALL 4 HEAD GROUPS.
*         ALSO CORRECTS INTERMITTANT DH825 ERRORS. PSR CML0671. 
* 
* 
* CLM      DHW  01/30/85
*          THIS CHANGE CORRECTS MISCELLANOUS DOCUMENTATION
*          ERRORS AND ADDS SOME ADDITIONAL EXPLANATIONS AS
*          DEEMED NECESSARY.
* 
* CCM      DHW  01/30/85
*          THIS CHANGE CORRECTS MISCELLANEOUS DOCUMENTATION 
*          ERRORS AND ADDS SOME ADDITIONAL  EXPLANATIONS AS 
*          DEEMED NECESSARY.
* 
* DFU     B.D    2/1/85 
*         MODSET CMLA367 ADDS THE 834 MODULES TO DFU. 
*         THESE MODULES ARE DFU11, DFU13, DFU15, DFU17. 
* 
* 
*         PSR CMLA369 
* HPA21   REF 85/01/30
*         MODSET CMLA369 ENABLES TAPE AND MASSTOR MEDIA REPORTS USING 
*         HPSORT, THE INTERNAL IN-LINE SORT (RATHER THAN SORT/MERGE). 
*         THE MESSAGE "TOO MANY SORT KEYS" APPEARED AT CML L170,
*         DENOTING THAT THE MEDIA REPORTS WERE DISABLED.
* 
* 
* HPA2    PWL  01/29/85 
*         MODSET CMLA334 DELETES FROM HPA THE PROCESSING OF NOS/BE
*         MESSAGE 316B (EST ENTRY). 
* 
* 
*       PSR CMLA328 
* HPA32 MBA 01/28/85
*       MODSET CMLA328 CHANGES COS TO CM IN THE DETAIL CHANNEL REPORT 
*       HEADER FOR CONTROLWARE LOGGED.  THE CM INDICATES CONTROL MODULE 
*       NUMBER. 
* 
* 
* FMC     JMO    85/01/21 
*         MODSET CORRECTS FMC28 TO DISPLAY THE CORRECT CW REV LEVEL.
*         PSR CMLA361.
* 
* 
* FHC     JMO    85/01/21 
*         MODSET CORRECTS FHC28 TO DISPLAY THE CORRECT CW REV LEVEL.
*         PSR CMLA361.
* 
* 
* MALETPI     JMO    84/10/30 
*         MODSET DELETES DEFECT, REFORM, AND REALLOCATE COMMANDS FROM 
*         THE FSD HIGH LEVEL LANGUAGE. PSR CMLA376. 
* 
* 
* ISD     JMO    84/10/30 
*         MODSET DELETES DEFECT, REFORM, AND REALLOCATE COMMANDS FROM 
*         THE ISD PRODUCT OVERLAY. PSR CMLA376. 
* 
* 
* FSD     JMO    84/11/06 
*         MODSET ADDS TEST 73 BACK INTO FSD, ADDS TEST 100H ISI TEST
*         AND DELETES MODULES FSD23, FSD25, AND FSD27 FROM TEST FSD.
*         PSR CMLA376.
* 
* 
* HISTORY PMW   85/02/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L173*. 
* 
* 
* 
* 
* FSD     JMO    85/01/31 
*         MODSET CORRECTS FSD10 TO USE MORE THAN 1 PATTERN. 
*         PSR CML0673.
* 
* 
*         PSR CMLA370 
* HPA     REF 85/02/04
*         MODSET CMLA370 REDUCES HPA FIELD LENGTH BY CHANGING THE 
*         PROGRAM STRUCTURE FROM OVERLAYS TO OVCAPS.
* 
* 
* MALET10     JMO    85/01/21 
*         MODSET ADDS DEVICES CODES 31 AND 32 FOR NON-IMPACT PRINTERS.
*         ALSO ADDS DEVICE CODE FOR PDP11 UNIBUS. PSR CMLA366.
* 
* 
* CMLINST     JMO    85/01/21 
*         MODSET ADDS NON-IMPACT PRINTER SUPPORT TO CMLINST PROCS.
*         PSR CMLA366.
* 
* 
* CMLINST     JMO    85/02/21 
*         MODSET CORRECTS CMLINST PROCS FOR NOSBE L577 CEID.
*         PSR CML0684.
* 
* 
* 844HT     JMO    85/02/25 
*         MODSET CORRECTS PRODUCT OVERLAY TO WAIT ONE SECOND ON INACTIVE. 
*         PSR CMLA375.
* 
* 
* 844FT     JMO    85/02/25 
*         MODSET CORRECTS PRODUCT OVERLAY TO WAIT ONE SECOND ON INACTIVE. 
*         PSR CMLA375.
* 
* 
* DFU     B.D    2/1/85 
*         MODSET CMLA377 MODIFIES 834 MODULES TO SUPPORT
*         835 DISK DRIVE. 
* 
* 
* HISTORY PMW   85/03/05
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L174*. 
* 
* 
* 
* 
* MALET10     JMO    85/02/27 
*         MODSET ADDS SUPPORT OF 836 DISK TO MALET. 
*         PSR CMLA383.
* 
* 
* ISD     JMO    85/02/14 
*         MODSET ADDS ISD2 SUPPORT TO PRODUCT OVERLAY.
*         PSR CMLA383.
* 
* 
* CMLINST     JMO    85/02/28 
*         MODSET ADDS SUPPORT FOR 836 DISK. 
*         PSR CMLA383.
* 
* 
* CMLINST     JMO    85/03/08 
*         MODSET CORRECTS NOSBE CMLINST FOR RETURN OF SKEDMODS TO 
*         BE SKEDMDS. PSR CML0692.
* 
* 
* PDP    DLK    85/01/04
*        THIS MODSET ADDS DECK PDP, WHICH IS THE CYBER/UNIBUS DIAGNOSTIC. 
* 
* 
* CRP      HPQ   03/05/85 
*          THIS MODSET REDUCES THE EXECUTION TIME OF CRP MODULES
*          TO AN ACCEPTABLE LEVEL BY REDUCING THE LOOP COUNTS OF
*          APPROXIMATELY HALF OF THE CRP MODULES. 
* 
* 
* CRP      HPQ   03/05/85 
*          THIS MODSET CORRECTS NUMEROUS CODING ERRORS IN MODULE
*          CRP53, 53A, AND 531. 
* 
* 
* CRP      HPQ   03/05/85 
*          THIS MODSET CHANGES THE DIAGNOSTIC REGISTER WRITE SUB- 
*          ROUTINE IN MODULES 29-53 FROM A MODE 0 TO A MODE 2 WRITE.
*          THIS INSURES THAT THE UPPER 4 BITS OF THE DIAGNOSTIC 
*          REGISTER ARE NOT INADVERTENTLY WRITTEN WITH 1'S, THUS
*          CAUSING A DMAU RESET.
* 
* 
* CRP      HPQ   03/05/85 
*          THIS MODSET CORRECTS CRP MODULE 98X - THE ERROR PROCESSOR
*          FOR MODULE CRP25.  A DIFFERENT SECTION OF THE OUTPUT 
*          BUFFER IS USED AS THE STAGING AREA FOR ERROR MESSAGES. 
* 
* 
* CRP      HPQ   03/05/85 
*          THIS MODSET CLEARS OUT THE CRP EXTERNAL RESET REGISTER 
*          AT THE END OF MODULES CRP09, CRP11, AND CRP19 TO PREVENT 
*          ANY ACTIVE RESETS FROM REMAINING AFTER MODULE EXECUTION. 
* 
* 
* CRP      HPQ   03/05/85 
*          THIS MODSET REMOVES A DCN FROM MODULES 23C, 23D, AND 23E 
*          DURING THE PROCESSING OF DATA ERRORS.  BY DEACTIVATING THE 
*          CHANNEL BETWEEN DATA FIFO READS THE REGISTER LOOP LOOSES SYNC. 
* 
* 
* HPA38   PWL 02/27/85
*         MODSET CMLA381 MODIFIES HPA FOR 810/830 AND 815/825 
*         MEMORY ENHANCEMENT. 
* 
* 
* HPA     PWL  02/28/85 
* HPA22   MODSET CMLA382A REMOVES THE PROCESS OF 845, 855, 840/860
* HPA3    PROCESSOR MESSAGES FROM DECK HPA310, ASSIGNS RECORD TYPE
* HPA310  102B TO 845, 855, 840/860 PROCESSOR MESSAGES AND SHORTENS 
*         P1MSG ARRAY.
* 
* 
* HPA311  PWL  85/03/01 
*         MODSET CMLA382B ADDS DECK HPA311 TO PROCESS 845, 855, 
*         AND 840/860 PROCESSOR MESSAGES. 
* 
* 
* HPA310  PWL  01/29/85 
*         MODSET CMLA253 UPDATES PAK LOCATION FOR 810/830 PROCESSOR 
*         ERRORS. 
* 
* 
* HPA310  PWL  01/30/85 
*         MODSET CMLA252 UPDATES PAK LOCATIONS FOR 835 PROCESSOR ERRORS.
* 
* 
* HPA35   PWL  03/12/85 
*         MODSET CMLA291 CORRECTS THE REPORTING OF PIP AND NPU/ 
*         COUPLER INTERFACE ERRORS. 
* 
* 
* HPA38    PWL  02/27/85
* HPA310  MODSET CMLA293
*         1) CHANGES THE SYMPTOM CODE FOR IOU EDD MESSAGES TO 112B
*            AND THE SYMPTOM CODE FOR P1/P2 EDD MESSAGES TO 113B, 
*         2) CORRECTS A PROBLEM THAT THE POTENTIAL HARD SECDED ERROR
*            SUMMARY SUBHEADER IS PRINTED WHEN THERE IS NO DATA,
*         3) REPORTS FAILING LOCATIONS FOR I1/I2 ERRORS WHEN LOCATION 
*            OF THE MODULES IS THE SAME FOR ALL BARRELS REGARDLESS
*            OF PP ERROR BITS.
* 
* 
* HPA310  PWL  01/30/85 
*         MODSET CMLA372 UPDATES PAK LOCATIONS FOR 815/825 PROCESSOR
*         ERRORS. 
* 
* 
* MALET     JMO    85/03/14 
*         MODSET CORRECTS MALET MESSAGE FOR DISK IDLE FROM UNLOAD 
*         TO DOWN. PSR CMLA385. 
* 
* 
*         PSR CMLA384 
* HPA2    REF 85/03/18
* HPA22   MODSET CMLA384 CORRECTS THE NON-STANDARD RELOCATIONS IN THE 
*         COMPASS-CODED DSA PROCESS.
* 
* 
* MSC     JMO    85/03/08 
*         MODSET CORRECTS MSC TO CHECK ALL MEMORY LOCATIONS.
*         PSR CML0588.
* 
* 
* NLM     CPK     85/03/21
*         MODSET ADDS *CALL COMDECKS CDNDM, CDNDP AND CDNDT TO NLM. 
*         PSR NUMBER IS CMLA388A. 
* 
* 
* CLM     CPK     85/03/21
*         MODSET ADDS *CALL COMDECKS CDNDM AND CDNDP TO CLM.
*         PSR NUMBER IS CMLA388B. 
* 
* 
* FLM     CPK     85/03/21
*         MODSET ADDS *CALL COMDECKS CDNDM AND CDNDP TO FLM.
*         PSR NUMBER IS CMLA388C. 
* 
* 
* CDNDM     CPK     85/03/21
*           MODSET CREATES COMMON DECK CDNDM. 
*           CDNDM IS CALLED BY NLM, CLM, AND FLM. 
* 
* 
* CDNDP     CPK     85/03/21
*           MODSET CREATES COMMON DECK CDNDP. 
*           CDNDP IS CALLED BY NLM, CLM, AND FLM. 
* 
* 
* CDNDT     CPK     85/03/21
*           MODSET CREATES COMMON DECK CDNDT. 
*           CDNDT IS CALLED BY NLM. 
* 
* 
* HPA37   PWL  03/19/85 
*         MODSET CMLA387 UPDATES ERROR CODES FOR MASSTOR M860 
*         MICROCODE LEVEL TCA.
* 
* 
* MALET11     JMO    85/03/21 
*         MODSET CORRECTS MALET11 TO HANDLE RESPONSE CODE OF 41B. 
*         PSR CMLA389.
* 
* 
* NIP    DHW    85/03/20
*        NIP IS A MONITOR FOR THE 5870 NON IMPACT PRINTER.
*        THE MONITOR ONLY SERVES TO INVOKE THE CONTROLWARE
*        DATA INTEGRITY TEST FUNCTION OF 77.
* 
* 
* DFU     B.D    3/25/85
*         MODSET CMLA390 CHANGES THE REFERENCES TO ISD(II)
*         FROM 835 TO 836.
* 
* 
*         PSR CMLA396 
* HPA3    REF 85/03/26
* HPA34   MODSET CMLA396 SUPPORTS THE ISD II, DEVICE TYPE DG. 
* 
* 
* DSPLOT   DDC    85/03/27
*          MODSET CORRECTS SPACING PROBLEMS IN THE HEADING AND
*          TEXT OF THE CE ERROR CODE LIST. PSR CML0699. 
* 
* 
* HISTORY PMW   85/04/03
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L175*. 
* 
* 
* 
* 
* CMLINST     JMO    85/04/05 
*         MODSET CORRECTS CMLINST FOR MORE THAN 50 CCL PARAMETERS.
*         PSR CMLA397.
* 
* 
* FSD     RDS     85/04/09
*         CMLA379 MODIFIES FSD TO SUPPORT EXECUTION ON ISD II DISK
*         SUBSYSTEM, AND REMOVES ALL LEVEL II DIAGNOSTICS 
*         CORRECTIVE ACTION MODULES 
* 
* 
* CMLINST     JMO    85/04/08 
*         MODSET CORRECTS CMLINST TO SUBSTITUTE THE VSN FOR REL1A FROM
*         THE ONE SPECIFIED WITH OPLVSN. PSR CML0703. 
* 
* 
* CMLINST     JMO    85/04/10 
*         MODSET CORRECTS CMLINST FOR THE NEW MODULES IN NLM, CLM AND 
*         FLM WHICH INCLUDE THE COMDECKS FOR DOCUMENTATION. PSR CMLA401.
* 
* 
* NIP      DHW  04/22/85
*          THIS CHANGE CORRECTS MISCELLANOUS DOCUMENTATION
*          ERRORS AND AN ERROR MESSAGE. 
* 
* MALET20     JMO    85/04/19 
*         MODSET CORRECTS MALET COMPILER FOR OFFLINE MODULE OVERFLOW. 
*         PSR CMLA415.
* 
* 
* DSPLOT  DDC    85/04/19 
*         MODSET CORRECTS DSPLOT FOR PACK SN TO BE READABLE.
*         PSR CMLA402.
* 
* 
*         PSR CMLA409 
* HPA     REF 85/04/17
* HPA36   MODSET CMLA409 SUPPORTS MAP III/IV TRANSPARENCY, WHICH
*         INVOLVES THE PROCESSING OF ERRORS FROM THE BML FILE.
*         ADDED ERROR INFORMATION TO BE REPORTED BY HPA CONSISTS
*         OF THE PPU AND THE MAP ACCESS NUMBER (A OR B).  ALSO, THE 
*         DETAIL REPORT HAS BEEN REVISED (PUT THE DATE ON THE DETAIL
*         LINE, ELIMINATE UNUSED HEADER FIELDS (EQ/UN), AND INCLUDE 
*         THE CHANNEL AND MFID).  FINALLY, ALL MAP III REFERENCES ARE 
*         CHANGED TO MAP III/IV AND THE MP3 (PP DRIVER) ERROR CODE
*         INTERPRETATION HAS BEEN CORRECTED.
* 
* 
* MALET     JMO    85/03/14 
*         MODSET ENHANCES MALET TO DISPLAY THE CVL ABORT MESSAGES 
*         AS A VALIDATION DENIED MESSAGE. PSR CML0269.
* 
* 
* MALET11     JMO    85/03/14 
*         MODSET ENHANCES MALET11 TO DISPLAY THE CVL ABORT MESSAGES 
*         AS A VALIDATION DENIED MESSAGE. PSR CML0269.
* 
* 
* MLD     JMO    85/03/14 
*         MODSET CORRECTS MLD TO HANDLE CHANNEL RESERVATION FOR 
*         NOSVE WHEN NOT IN THE EST. PSR CML0269. 
* 
* 
* CMLINST     JMO    85/04/23 
*         MODSET CORRECTS CMLINST PROC UPDATE TO RUN ON TAPE
*         RESIDENT OLDPL ON SECOND PASS. PSR CMLA411. 
* 
* 
* DSPLOT     JMO    85/04/24
*         MODSET CORRECTS DSPLOT FOR SPACING PROBLEM. 
*         PSR CMLA417.
* 
* 
* MALET     JMO    85/04/15 
*         MODSET CHANGES THE 77 TABLE FOR OFFLINE DEMOT TO MATCH A
*         STANDARD TYPE 77 TABLE. PSR CMLA418.
* 
* 
* MALET11     JMO    85/04/15 
*         MODSET CHANGES THE 77 TABLE FOR OFFLINE DEMOT TO MATCH A
*         STANDARD TYPE 77 TABLE. PSR CMLA418.
* 
* 
* CLM      DHW  04/23/85
*          THIS CHANGE ALLOWS A STATUS OF 0000 OR 5403
*          FOLLOWING THE INVOKING OF THE IN-LINE DIAG.
* 
* MLTDOC  JMO   85/05/01. 
*         MODSET CORRECTS MLTDOC NOT TO SAY TRADE SECRET AS PER THE 
*         MEMO BY R.V. SCHORNSTEIN. PSR CMLA422.
* 
* 
* CPYCOM  JMO   85/05/01. 
*         MODSET CORRECTS CPYCOM NOT TO SAY TRADE SECRET AS PER THE 
*         MEMO BY R.V. SCHORNSTEIN. PSR CMLA422.
* 
* 
* CPYFTN  JMO   85/05/01. 
*         MODSET CORRECTS CPYFTN NOT TO SAY TRADE SECRET AS PER THE 
*         MEMO BY R.V. SCHORNSTEIN. PSR CMLA422.
* 
* 
* DMA    HPQ     85/05/03.
* 
*         DMA IS A SET OF MODULES DESIGNED FOR TESTING THE CYBERPLUS
*         DIRECT MEMORY ACCESS UNIT (DMAU). 
* 
* 
* HISTORY LJC   85/05/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L176*. 
* 
* 
* 
* 
*         PSR CMLA421 
* HPA     REF 85/04/30
*         MODSET CMLA421 COMPENSATES FOR THE FTN5 DEFICIENCY OF NOT 
*         SEARCHING SYSTEM LIBRARIES FOR OVCAP CALLS.  IT REPLACES
*         LOVCAP, THE FTN5 LOADER ROUTINE, WITH AN INLINE ROUTINE OF
*         THE SAVE NAME WHICH SPECIFIES THE USER LIBRARY HPALIB IN ITS
*         SEARCH FOR OVCAPS.  THE COMPASS CODE WAS SUPPLIED BY CHUCK
*         FOLEY AND INTEGRATED INTO THE MAIN HPA OVERLAY. 
* 
* 
* CMLINST     JMO    85/05/06 
*         MODSET CORRECTS CMLINST FOR HPA OVL CAP CHANGES.
*         PSR CMLA424.
* 
* 
* MST     JMO   85/04/30. 
*         MODSET CORRECTS MST FOR CORRECT HEAD SELECTION BY STREAM
*         NUMBER. PSR CMLA404.
* 
* 
* D88     JMO    85/05/02 
*         MODSET CORRECTS DL8 TO ALSO POST A SMALL SECTOR MESSAGE OF
*         CYLINDER TRACK AND SECTOR TO BE USED FOR FLAWS. PSR CML0716.
* 
* 
* D88     JMO    85/05/15 
*         MODSET CORRECTS D88 SO DH847 WILL BE COMPILED FOR OFFLINE.
*         PSR CMLA431.
* 
* 
* CMLINST     JMO    85/05/16 
*         MODSET CORRECTS CMLINST TO DELETE REPLACE HPA IN THE EDITLIB. 
*         THIS IS NO LONGER NEEDED BECAUSE OF OVL CAPS. PSR CMLA434.
* 
* 
* T7X     JMO    85/05/16 
*         MODSET CORRECTS T7X MODULE 76 TO TEST THE BYPASS OF NOISE 
*         RECORDS IN FORWARD RATHER THAN REVERSE. THIS IS TO MATCH
*         THE NEW MICROCODE. PSR CMLA435. 
* 
* 
*         PSR CMLA425 
* HPA21   REF 85/05/09
* HPA32   MODSET CMLA425 REDUCES THE FIELD LENGTH WHEN USING HPSORT,
* HPA4    THE INLINE SORT.
* HPA8
* HPA9
* 
* 
*         PSR CMLA427 
* HPA2    REF 85/05/16
*         MODSET CMLA427 ADDS ERROR CODES 40/41B TO THE PROCESS MACROS
*         FOR DISKS, THUS ENABLING DETAILED STATUS ANALYSIS (DSA) FOR 
*         DISK READ/WRITE PARITY ERRORS.  THESE ERRORS WERE INTRODUCED
*         BY NOS 2.3 WITH DISK TRANSPARENCY.
* 
* 
*         PSR CML0649 
* HPA36   REF 85/02/28
*         MODSET CML0649 CORRECTS THE UNIT ANLYSIS REPORT PROBLEM OF
*         TREATING CY176 STATUS/CONTROL REGISTER SSM ERRORS AS LCME 
*         ERRORS. 
* 
* 
*         PSR CML433
* HPA3    REF 05/16/85
*         MODSET CMLA433 PROCESSES ERRORS LOGGED IN THE BML DURING
*         DEADSTART TIME, BEFORE THE OPERATOR HAS ENTERED DATE/TIME.
*         NORM HAS SUPPLIED THE DATE OF PROCESSING IN THE DATE FIELD. 
*         THE HH. (HOURS) FIELD WILL BE FLAGGED BY "DS" FOR DEADSTART 
*         AND THE MM.SS (MINUTE.SECOND) FIELD WILL CONTAIN THE SECONDS
*         AFTER DEADSTART PROCESS BEGAN AT WHICH THE ERROR WAS LOGGED.
*         THUS, ERRORS WHICH OCCURRED DURING DEADSTART WILL BE REPORTED 
*         FOR ALL DEVICES.  THE NEED FOR THIS REPORTING WAS MANIFESTED
*         BY AN ABUNDANCE OF 895 ERRORS WHICH CAN OCCUR DURING DEADSTART. 
* 
* 
*         PSR CML442
* HPA22   REF 05/24/85
* HPA34   MODSET CMLA442 DISPLAYS SELECTED ISD I/II HEXADECIMAL FIELDS
*         IN THE DETAIL REPORT.  THE FOLLOWING FIELDS WILL BE DISPLAYED 
*         AFTER THEY ARE EXTRACTED FROM DETAILED STATUS AND VALIDATED:  
*         SYSTEM INTERVENTION CODE, MANUAL INTERVENTION CODE, DELAY CODE
*         AND LEVELS I AND II DIAGNOSTIC CODES.  MODSET ALSO DISABLES 
*         THE DESCRIPTION OF CM DIAGNOSTIC ERROR CODES.  THIS FEATURE 
*         PROVED UNSUPPORTABLE.  THE CODES ARE VENDOR-SUPPLIED AND NOT
*         CONTROLLED BY CDC.
* 
* 
* COMHPAERT 
* HPA22   RAS    85/02/15 
*         MODSET CMLA443 MAKES SIGNIFICANT CHANGES TO THE 885 DSA 
*         PROCESS.  THIS MODSET CHANGES THE ERROR CODE ASSIGNED TO
*         MOST MESSAGES.  USE OF HPA HISTORY DATA WHICH WAS PROCESSED 
*         USING A PREVIOUS VERSION OF HPA MUST BE REPROCESSED USING 
*         THE DSA=ALL PARAMETER. OTHERWISE, ERRONEOUS ERROR MESSAGES
*         WILL BE PRODUCED.  THIS MODSET WAS GENERATED USING THE DSA
*         DLT EDITOR AND CORRESPONDS TO MODSET CMLA443 ON FLOWPL. 
* 
* 
* CMLINST     JMO    85/05/13 
*         MODSET ADDS DECK DMA FOR CYBERPLUS TO CMLINST.
*         PSR CMLA429.
* 
* 
* FMC     JMO    85/05/20 
*         MODSET CORRECTS FMC99A TO NOT TRUNCATE THE DESCRIPTION OF 
*         PARAMETER P8. PSR CMLA430.
* 
* 
* FHC     JMO    85/05/20 
*         MODSET CORRECTS FHC99A TO NOT TRUNCATE THE DESCRIPTION OF 
*         PARAMETER P8. PSR CMLA430.
* 
* 
* CMLINST     JMO    85/05/23 
*         MODSET CORRECTS CMLINST UTIL PROC TO HANDLE OV CAPS FOR 
*         NEW HPA. PSR CMLA437. 
* 
* 
* ISD     JMO    85/05/24 
*         MODSET CORRECTS ISD PRODUCT OVERLAY TO NOT RESERVE THE CM 
*         ON A AUTOLOAD HOST COMMAND. PSR CMLA439.
* 
* 
* MALET20     JMO    85/05/22 
*         MODSET CORRECTS THE COMPILER TO LIST DEMOT MODULES IN 
*         THE OUTPUT FILE CORRECTLY. PSR CMLA440. 
* 
* 
* FMU     JMO    85/05/21 
*         MODSET ADDS A WARNING MESSAGE TO THE FMU FORMAT UTILITY 
*         TRACK MODULES. PSR CML0720. 
* 
* 
* HISTORY LJC   85/06/04
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L177*. 
* 
* 
* 
* 
*         PSR CMLA448 
* HPA32   REF 06/11/85
* HPA34   MODSET CMLA448 ENHANCES 895 REPORTING BY SELECTIVELY PROVIDING
*         SENSE BYTE STATUS FOR ALL ERRORS, DEVICE TYPES "CH" AND "DC", 
*         BASED ON GENERAL STATUS.  IT ALSO SUPPRESSES THE DETAIL REPORTING 
*         OF FORMAT 6 ERRORS (OVERRUNS) AND PROVIDES A SUMMARIZATION
*         OF FORMAT 6 ACTIVITY AT THE END OF THE DETAIL REPORT. 
* 
* 
*         PSR CMLA449 
* HPA22   REF 06/17/85
*         MODSET CMLA449 ELIMINATES THE LOADER ERROR INTRODUCED BY
*         INTEGRATION OF DSA 885 CODE (MODSET CMLA443) AND OVCAPS.
*         IT RESULTED FROM NONSTANDARD RELOCATIONS EXISTING IN THE
*         INTERMIXED COMPASS CODE.  STANDARD RELOCATION IS THE RE-
*         LOCATION OF 18 BIT FIELDS WHOSE RIGHTMOST BIT IS BIT 0, 
*         15 OR 30 OF A CENTRAL MEMORY WORD.
* 
* 
* HPTEXT   DDC    85/06/07
*          THE DECK HPTEXT IS A TEXT FILE  WHICH CONTAINS A SYMBOL NAME 
*          FOR EACH AND EVERY ERROR CODE AND SYMPTOM CODE KNOWN TO HPA. 
*          THIS DECK SHOULD HELP IN THE GENERATION AND MAINTENANCE OF 
*          PROGRAMS WHICH PROCESS ERRORS FROM THE SEF FILE OR THE OLDHF 
*          FILE.  THIS DECK IS NOW USED BY THE PROGRAM DSPLOT AT CML
*          LV 173 AND ABOVE.
* 
* 
* CWEOR7    DDC    85/06/07 
*           COMPILING THE DECK CWEOR7 CAUSES AN END OF RECORD TO BE WRITTEN 
*           ON THE COMPILE FILE.  THIS DECK IS USED DURING THE INSTALLATION 
*           OF THE PROGRAM DSPLOT.
* 
* 
* DSPLOT   DDC    85/06/06
*          THIS MODSET CORRECTS A VARIETY OF ILL WITH THE PROGRAM 
*          DSPLOT. PSR CMLA446. A LIST OF THOSE ILLS FOLLOWS. 
*          1.  THE MFID WAS NOT PROCESSED PROPERLY
*          2.  REPORT NUMBER FOUR DID NOT LIST THE FAILING MFID 
*          3.  THE NUMBER OF DAYS TO PROCESS WAS CONFUSING. 
*          5.  A PACK NUMBER OF ALL 0'S WAS PRINTED AS COLON'S
*          6.  A LISTING OF ERRORS BY MFID AND CHANNEL WAS NEEDED.
*          7.  HARD- CODDED OCTAL ERROR AND SYMPTOM CODES WERE REPLACED 
*              BY SYMBOL NAMES THAT ARE SATISFIED BY THE TEXT FILE
*              HPTEXT IN ORDER TO SYMPLIFY PROGRAM MAINTENANCE
* 
* 
* DKDATA   DDC    85/04/24
*          MODSET MAKES CORRECTIONS AND ADDITIONS TO ERROR
*          DESCRIPTION TEXT IN THE FILE DKDATA. PSR CMLA446.
* 
* 
* CMLINST DDC 85/04/01
*         THIS MODSET ADDS THE TEXT FILE HPTEXT TO THE CML INSTALLATION 
*         PROCEDURES.THIS FILE WILL BE USED BY THE PROGRAM DSPLOT 
*         AS A REFERENCE FOR CONVERTING OCTAL CODES OBTAINED FROM THE 
*         SEF OR OLDHF, INTO SYMPTOM CODES. 
*         THIS MODSET WILL ALSO MODIFY THE INSTALL PROCESS FOR DSPLOT IN
*         ORDER TO USE THE TEXT FILE HPTEXT. PSR CMLA445. 
* 
* 
* CMLINST     JMO    85/06/24 
*         MODSET CORRECTS CMLINST FOR EXECUTE IF DEBUG IS NOT USED
*         ON NOSBE FOR PDP AND NIP. PSR CMLA454.
* 
* 
* CMLINST     JMO    85/06/20 
*         MODSET CORRECTS CMLINST DOCUMENTATION SO SYSVER=NOS23 ALSO
*         CAN BE USED FOR NOS 2.3 AND ABOVE. PSR CMLA450. 
* 
* 
* CCM     DHW   85/06/21. 
* 
*         THIS MODSET ALLOWS CCM TO SUPPORT THE 895 
*         (DC=115), MASSTOR(DC=104) AND NIP(DC=31,32) 
*         SUBSYSTEMS. 
* 
* 
*         PSR CML380
* HPA     REF 06/14/85
* HPA39   MODSET CMLA380 ENHANCES LCN REPORTING AS FOLLOWS@D
*         1) SUPPRESSES CONSECUTIVE CONNECTION ERROR MESSAGES THAT ARE
*            IDENTICAL EXCEPT FOR TIME.  THEIR OCCURRENCE IS DENOTED BY 
*            A REPEAT COUNT, ALONG WITH THE FROM/TO TIMES;
*         2) ADJUSTS THE TRUNK ERROR LOG ALGORITHM; 
*         3) IGNORES BIT READOUT OF HARDWARE STATUS IF STATUS=7777B;
*         4) CHANGES CONNECTION ERROR MESSAGES FROM SX TO TX. 
* 
* 
* HPA     PWL 04/30/85
* HPA3    MODSET CMLA400 SUPPORTS CYBER 180-990 (THETA) PROCESSOR AND 
* HPA311  MEMORY ERRORS.
* HPA313
* HPA314
* HPA5
* 
* 
* MALET30     JMO    85/06/27 
*         MODSET CORRECTS MALET INITIALIZATION TO SET CHANNELS
*         20-33 ON A 10 PP SYSTEM FOR 180S. PSR CML0729.
* 
* 
* MLD     JMO    85/06/11 
*         MODSET CORRECTS MLD TO LOAD FROM THE NEW MODULE BUFFER
*         ADDRESS EQUATED BY THE NEW 77 TABLES. PSR CMLA447.
* 
* 
* HISTORY LJC   85/07/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L178*. 
* 
* 
* 
* 
*         PSR CML455
* HPA32   REF 07/02/85
*         MODSET CMLA455 CORRECTS THE CONTROLWARE REVISION NUMBER FOR THE 
*         CHANNEL MESSAGE DETAIL REPORT WHEN IT CONTAINS LOADING ZEROS, 
*         WHICH IT CONVERTS TO BLANKS.
* 
* 
*         PSR CMLA460 
* HPA     REF 85/07/12
* HPA3    MODSET CMLA460 SUPPORTS RMS RAM ENHANCEMENTS - PHASE I. 
* HPA32 
* HPA34 
* HPA36 
* 
* 
* HPTEXT   DDC    85/07/19
*          THIS MODSET ADDS FOUR ERROR CODES TO THE DECK HPTEXT.
*          THESE ERROR CODES WERE ADDED BY THE  RMS RAM ENHANCEMENTS
* 
* 
* DSPLOT   DDC    85/07/19
*          THIS MODSET ENTERS FOUR NEGENERIC ERROR CODES INTO 
*          THE DSPLOT PROCESS. THESE CODES WERE GENERATED BY THE
*          RMS RAM ENHANCMENT.  THIS MOD WILL ALSO INCLUDE SOME EROR
*          CODES THAT WERE PREVIOUSLY CHARGED AGAINST THE DISK PACK 
*          IN REPORT NUMBER ONE THAT SHOULD NOT HAVE BEEN.
* 
* 
* DKDATA   DDC    85/07/19
*          THIS MODSET ADDS FOUR NEW CODES TO DKDATA AS A RESULT OF THE 
*          RMS RAM ENHANCMENT PROGRAM.
* 
* 
* CLM      DHW  06/14/85
*          THIS CHANGE ADDS A MODULE TO CLM WHICH INVOKES 
*          THE DATA CHECK TEST (04 FUNCTION) IN THE MASS- 
*          TOR SUBSYSTEM CCC CONTROLWARE. 
* 
* FMD     JMO    85/07/08 
*         MODSET CORRECTS FMD MODULE 69 NOT TO RESERVE THE DRIVE BETWEEN
*         THE LAST WRITE AND THE WRITE VERIFY. PSR CMLA458. 
* 
* 
* MALET     JMO    85/05/09 
*         MODSET CORRECTS MALET IN TERMINAL MODE TO USE THE AUTO
*         FEATURE. PSR CML0715. 
* 
* 
* MALET10     JMO    85/05/09 
*         MODSET CORRECTS MALET IN TERMINAL MODE TO USE THE AUTO
*         FEATURE. PSR CML0715. 
* 
* 
* MALET12     JMO    85/05/09 
*         MODSET CORRECTS MALET IN TERMINAL MODE TO USE THE AUTO
*         FEATURE. PSR CML0715. 
* 
* 
* MALET30     JMO    85/05/09 
*         MODSET CORRECTS MALET IN TERMINAL MODE TO USE THE AUTO
*         FEATURE. PSR CML0715. 
* 
* 
* CMLINST     JMO    85/07/29 
*         MODSET CORRECTS CMLINST PROCEDURES FOR CMLUTIL PROC FOR THE 
*         CORRECT SYSVER DEFINE FOR SKEDULR. DPSR CML0738.
* 
* 
* SKEDULR     JMO    85/07/30 
*         MODSET CHANGES SKEDULR TO CALL COMDECK ASSYTAG FOR ASSEMBLY 
*         TAG DEFINES SO "SYSVER" PARAMETER CAN BE TIED TO THE CURRENT
*         SYSTEM IN THE CMLINST PROCEDURES. PSR CMLA465.
* 
* 
* CMLINST     JMO    85/08/01 
*         MODSET CORRECTS CMLINST PROCEDURES FOR NOSBE TO USE SYSVER IN 
*         THE ASSEMBLY OF SKEDULR. PSR CMLA465. 
* 
* 
* MALET     JMO    85/08/06 
*         MODSET ALLOWS MALET TO HANDLE LOWER CASE ASCII ALPHA CHARACTERS.
*         PSR CML0740.
* 
* 
* HISTORY LJC   85/08/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L179*. 
* 
* 
* 
* 
* MALET10  RDS    85/08/07
*          MODSET CMLA469A MAKES CHANGES TO DECK MALET10 FOR ADDITION OF
*          FSD2 PRODUCT OVERLAY 
* 
* 
* MALET20  RDS    85/08/07
*          MODSET CMLA469B MAKES CHANGES TO DECK MALET20 FOR ADDITION OF
*          FSD2 PRODUCT OVERLAY 
* 
* 
* MALET2P RDS   85/08/07. 
* 
*         THIS MODSET ADDS DECK MALET2P TO THE CL LIBRARY.
*         DECK MALET 2P IS THE LANGUAGE COMPILER SUBSET FOR THE 
*         FSD2 PRODUCT OVERLAY. 
* 
* 
* MALETPP RDS   85/08/07. 
* 
*         THIS MODSET ADDS COMMON DECK MALETPP TO THE CL LIBRARY. 
*         MALETPP IS THE COMMON DECK USED BY THE FSD2 PRODUCT 
*         OVERLAY COMPILER. 
* 
* 
* MLD   RDS     85/08/07
*       MODSET CMLA469C MAKES CHANGES TO DECK MLD FOR ADDITION OF 
*       FSD2 PRODUCT OVERLAY
* 
* 
* ISD1    RDS   85/06/05. 
* 
*         THIS MODSET ADDS COMMON DECK ISD1 TO THE CL LIBRARY.
*         COMMON DECK ISD1 CONTAINS THE CODE FOR THE FSD2 PRODUCT 
*         OVERLAY.
* 
* 
* DTI   RDS     85/08/07
*       THIS MODSET ADDS DECK DTI TO THE CL LIBRARY.  DTI IS A
*       DATA PATH INTEGRITY TEST FOR THE ISD DISK SUBSYSTEMS, 
*       WRITTEN IN MALET. 
* 
* 
* CMLINST     JMO    85/08/19 
*         MODSET ADDS DTI TO CMLINST PROCEDURES.
*         PSR CMLA472.
* 
* 
* FMC     JMO    85/08/23 
*         MODSET CORRECTS FMC MODULES 49 AND 69 TO CHANGE THE MESSAGE 
*         FOR B14 TO ADD IF PRESENT. PSR CML0743. 
* 
* 
*         PSR CMLA473 
* HPA3    REF 85/09/03
* HPA32   MODSET CMLA473 SUPPRESSES THE FUNCTION CODE LOGGED BY 6DI WHEN
* HPA34   THE NOS FLAG INDICATING A VALID CODE IS NOT SET.  NOS INTRODUCES
*         THIS FLAG AT L642, NOS 2.4.2. 
* 
* 
* HISTORY LJC   85/09/11
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L180*. 
* 
* 
* 
* 
* CDNDT   WJD   85/9/19 
*         ADDS COMMENTS FOR NDT MODULE 7 LARGE BUFFER TESTING 
* 
* 
* T7X     DDC    85/01/03 
*         THIS MODSET INSERTS SEVERAL CHANGES TO T7X. 
*         1. CHANGE MODULE T7X82 TO DO LONG WRITES AND USE RANDOM PATTERN 
*            IF PARAMETER WORD 4 HAS 2XXX SET.
* 
*         2. ADDS MODULES 83, 83A, 84, 85, 85A, AND 93 TO REPAIR
*            MODULES AND MODULES 98F AND 98G TO ERROR PROCESSING MODULES. 
*            ADD MODULES 86 AND 87 TO ALLOW TESTING TAPE MEDIA. 
* 
*         3. INSERT MODULE T7X93 TO PROVIDE THE ABILITY OF READING
*            MOST ANY TAPE AND DISPLAYING ACCUMULATED TRACK ERRORS
*            IN A MANNER SIMILAR TO T7X82.
* 
*         4. HAVE END-OF-TAPE CHECK TO MODULES T7X83A AND T7X85A. 
*            THIS WAS DONE BY ADDING A COMMON ERROR CODE 0060 WHICH 
*            MAY BE USED BY OTHER MODULES.  AN ADDITIONAL MODULE
*           (T7X98G) HAD TO BE ADDED TO PROCESS EC0060, VIA A CALL
*            TO T7X98A WITH (EC) = 0060.
* 
*         5. AFTER GIVING A GO TO THE FOLLOWING ERROR-
*                 T7X43 - ERROR CODE = 200 AT LINE (EA) = 0076
*            WE GET  T7X43 - ABORT ON .ENDFILE. COMMAND - 
*                  T7X43  EC5110 L111  CH NOT RESERVED
* 
*            MODSET ADDS CODE TO MODULE T7X84 TO RESERVE
*            THE CHANNEL AFTER AN ERROR IS GIVEN A *GO*.
* 
* 
*         PSR CMLA480 
* HPA     REF 85/09/05
* HPA3    MODSET CMLA480 SUPPORTS DFT FOR THETA PROCESSOR AND MEMORY. 
* HPA313
* HPA314
* 
* 
* DFU     DHW   85/09/19. 
* 
*         THIS MODSET CORRECTS DOCUMENTATION AND
*         MODULE CARD DEVICE CODES IN THE 99
*         MODULES.
* 
* 
* DMA      HPQ   09/20/85 
*          THIS MODSET CORRECTS CODING ERRORS IN MODULE 
*          DMA39 AND DMA43. 
* 
* 
*         PSR CMLA483 
* HPA32   REF 85/09/25
* HPA34   MODSET CMLA483 SUPPRESSES FORMAT 6 STATS/OVERRUN DATA FOR 
*         895 CHANNEL ERRORS AND SUMMARIZES THE COUNTS AT THE END OF
*         THE DETAIL REPORT.
* 
* 
*         PSR CMLA486 
* HPA3    REF 85/09/26
* HPA38   MODSET CMLA486 SUPPORTS DFT FOR THETA PROCESSOR/MEMORY AND I2 
* HPA313  FOR THE 2ND PRE-RELEASE VERSION TO CE.
* HPA314
* 
* 
* DTI      RDS    85/09/27
*          THIS MODSET MAKES THE NECESSARY CHANGES TO ALLOW 
*          EXECUTION OF THE DTI TEST ON AN 895 DISK SUBSYSTEM.
* 
* 
* ISD1     RDS    85/09/27
*          THIS MODSET MAKES CHANGES TO THE FSD2 PRODUCT OVERLAY
*          TO SUPPORT THE 895 DISK SUBSYSTEM
* 
* 
* CMLINST     JMO    85/09/30 
*         MODSET ADDS DTI SUPPORT FOR 895 TO CMLINST PROCS. 
*         PSR CMLA488.
* 
* 
*         PSR CMLA489 
* HPA34   REF 85/10/02
*         MODSET CMLA489 CORRECTS THE FATAL CONDITION WHICH RESULTED
*         FROM A TYPO IN CMLA483/CL179PD. 
* 
* 
* MST     JMO    85/10/02 
*         MODSET CORRECTS MST TO NOT STOP ON MSA BYTE 15 BIT 5 WHICH
*         IS UNDEFINED. PSR CML0753.
* 
* 
* FMD     JMO    85/10/03 
*         MODSET CORRECTS FMD MODULES 52 THROUGH 60 TO RERESERVE
*         THE DRIVE ON MODULE DETECTED ERROR IF CONDITIONS 0 OR 1.
*         PSR CML0757.
* 
* 
* MALET     JMO    85/10/08 
*         MODSET CORRECTS MALET PRINT TO DISPLAY ON A TERMINAL LINE LIMIT 
*         MESSAGE WHEN TWO OUTPUT FILES ARE SPECIFIED. PSR CML0752. 
* 
* 
* DSPLOT  GLG    85/10/09 
*         MODSET CORRECT LOADER ERRORS WITH DSPLOT. 
* 
* 
* DTI      RDS    85/10/03
*          MODSET CMLA491 INSERTS MODULE RUN TIMES IN THE EXTERNAL DTI
*          DOCUMENTATION. 
* 
* 
* FMD     JMO    85/10/09 
*         MODSET CORRECTS FMD TO ADD THE CLOCK PWBS TO ERROR 01003. 
*         PSR CML0763.
* 
* 
* MLTDOC     JMO    85/10/10
*         MODSET CORRECTS MLTDOC TO PRINT THE CORRECT DOCUMENTATION TYPE
*         ON THE LAST PAGE OF THE TABLE OF CONTENTS. PSR CMLA494. 
* 
* 
* T7X     DDC    85/10/10 
*         MODSET ADDS DOCUMENTATION LINES TO T7X99 FOR MODULE T7X86,
*         T7X87 AND T7X93.
* 
* 
* HISTORY LJC   85/10/14
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L181*. 
* 
* 
* 
* 
*         PSR CMLA487 
* HPA2    GFS 85/10/03
* HPA21   MODSET CMLA487 CONVERTS SORT/MERGE 4 COMMANDS TO SORT/MERGE 5 
*         COMMANDS. 
* 
* 
* CMLINST     JMO    85/10/23 
*         MODSET CORRECTS PROC CML1 FOR CODING ERROR ON MASSTOR.
*         PSR CMLA501.
* 
* 
*         PSR CMLA498 
* HPA     REF 85/10/01
* HPA22   MODSET CMLA498 SUPPORTS DFT FOR ALL MAINFRAME ERRORS AND
* HPA3    FOR THE 2ND PRE-RELEASE VERSION TO CE.
* HPA38   MESSAGES. 
* HPA310
* HPA311
* HPA312
* HPA313
* HPA314
* 
* 
* CMLINST     JMO    85/11/04 
*         MODSET CORRECTS CMLINST PROC SYSTAPX FOR ENDIF STEP4C.
*         PSR CMLA506.
* 
* 
* MALET10     JMO    85/10/09 
*         MODSET CORRECTS MALET10 TO PUT THE LANGUAGE COMPILERS AND 
*         PRODUCT OVERLAYS IN THE CORRECT ORDER. PSR CMLA505. 
* 
* 
* MALET20     JMO    85/10/09 
*         MODSET CORRECTS MALET20 TO PUT THE LANGUAGE COMPILERS AND 
*         PRODUCT OVERLAYS IN THE CORRECT ORDER. PSR CMLA505. 
* 
* 
* MALET2P     JMO    85/10/09 
*         MODSET CORRECTS MALET2P TO PUT THE LANGUAGE COMPILERS AND 
*         PRODUCT OVERLAYS IN THE CORRECT ORDER. PSR CMLA505. 
* 
* 
* MALET     JMO    85/10/23 
*         MODSET CORRECTS MALET FOR NOSBE ASSEMBLY ERRORS.
*         PSR CMLA500.
* 
* 
* HISTORY LJC   85/11/05
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L182*. 
* 
* 
* 
* 
* ISD1     RDS    85/11/05
*          THIS MODSET CORRECTS A PROBLEM WITH THE RESERVE SEQUENCE 
*          OF THE ISD1 PRODUCT OVERLAY WHEN RUN ON 895 DISK 
* 
* 
*         PSR CML0758 
* COM-    REF 85/10/31
* HPAERT  MODSET CML0758 CONDENSES 2550, ISMT AND 7990 ERROR MESSAGES 
*         OF 30 CHARACTERS TO THE REQUIRED 28 CHARACTERS FOR HPA. 
* 
* 
*         PSR CMLA407 
* HPA     REF 85/10/30
* HPA3    MODSET CMLA407 SUPPORTS I4 ERRORS LOGGED IN THE BML WITH A
* HPA312  MSGID OF 250B.  AFTER PROCESSING IN THE BMLDFT ROUTINE, THE 
* HPA314  I4 ERRORS RESIDE ON THE SEF FILE FOR REPORTING BY HPA, WITH 
*         AN MR DEVICE TYPE AND A 107B RECORD TYPE. 
* 
* 
*         PSR CML0737 
* HPA3    REF 85/11/07
* HPA35   MODSET CML0737 CORRECTS THE 2550 NODE NUMBER TO CORRESPOND
* HPA5    TO THE DECIMAL NODE NUMBER REPORTED BY THE OPERATING SYSTEM.
*         HPA HAD BEEN REPORTING THE NODE NUMBER AS AN OCTAL VALUE IN 
*         2550 DETAIL, ANALYSIS AND SUMMARY REPORTS.
* 
* 
*         PSR CMLA496 
* HPA     GFS 85/11/08
* HPA3    MODSET CMLA496 ENABLES HPA TO REPORT ERROR MESSAGES 
* HPA32   PERTAINING TO CDCNET THAT ARE NOT REPORTED IN NPA.
* HPA35 
* COMHPAERT 
* 
* 
*         PSR CMLA511 
* HPA21   REF 85/11/18
*         MODSET CMLA511 REDUCES HPA FIELD LENGTH TO <100K, WHEN THE
*         INTERNAL SORT, HPSORT, IS DEFINED.
* 
* 
* CMLINST     JMO    85/11/19 
*         MODSET CORRECTS PROC CML5 NOT TO COMPILE DFU AND DTI IF 83X IS
*         NOT DEFINED. PSR CMLA512. 
* 
* 
* IST    WJD    85/11/18
* 
* 
* 
*         PSR CMLA514 
* HPA32   GFS 85/11/19
*         MODSET CMLA514 CORRECTS AN ERROR IN REPORTING THE MDI SOFTWARE
*         VERSION NUMBER AND THE MFID CODE. 
* 
* 
* MALET20     JMO    85/11/19 
*         MODSET CORRECTS MALET20 FOR CORRECT DT FOR D895.
*         PSR CMLA515.
* 
* 
* T7X     JMO    85/11/13 
*         MODSET CORRECTS T7X TO ADD PARAMETER TO DISABLE ERROR CORRECTION
*         IN THE REVERSE READ MODULES. NORMAL FOR REVERSE READ WILL BE
*         ERROR CORRECTION. PSR CMLA510.
* 
* 
* FSD     JMO    85/11/11 
*         MODSET CORRECTS MODULE 11 DEADMAN TIMER TO THE NEW SPEC 
*         OF 5-16 SECONDS. PSR CMLA508. 
* 
* 
* HISTORY LJC   85/12/11
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L183*. 
* 
* 
* 
* 
* ITU   WJD     85/11/18
*       MODSET ADDS DEAD MAN TIMER TESTING TO ITU 
* 
* 
* CMLINST     JMO    85/12/16 
*         MODSET CORRECTS CMLUTIL PROC TO ADD MESSAGE ABOUT IAF.
*         PSR CML0775.
* 
* 
* T7X     JMO    85/12/13 
*         MODSET CORRECTS T7X MODULE 31 FOR THE CHANGE IN TACH PULSES CREATED 
*         BY FCO CA 46394 ON PE/GCR 200 IPS UNITS. PSR CML0771. 
* 
* 
* CMLINST     JMO    85/12/10 
*         MODSET CORRECTS DOCUMENTATION TO SORT/MERGE 5 RATHER THAN 4.
*         PSR CMLA517.
* 
* 
* HISTORY LJC   86/01/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L184*. 
* 
* 
* 
* 
* CMLINST     JMO    85/12/03 
*         MODSET ADDS MENU DRIVEN INTERACTIVE PROCEDURES FOR INSTALLING 
*         CML ON NOS. PSR CMLA528.
* 
* 
*         PSR CMLA534 
* HPA2    REF 86/01/16
*         MODSET CMLA534 PROTECTS HPA FROM MLTF OVERFLOW ENTRIES, WHICH 
*         MAY CAUSE HPA TO FAIL.  THE REASON FOR THE OCCURRENCE OF MORE 
*         THAN 21 MLTF ENTRIES PER TIME STAMP REMAINS UNRESOLVED, BUT IT
*         COULD BE EXPLAINED BY RUNNING WITH MORE THAN ONE MLTF.
* 
* 
*         PSR CMLA526 
* HPA     GFS 86/01/13
* HPA3    MODSET CMLA526 SUPPORTS CYBERPLUS ERRORS LOGGED IN THE BML WITH 
* HPA315  A MSGID OF 310B.  AFTER PROCESSING IN THE BMLCP ROUTINE, THE
* HPA5    CYBERPLUS ERRORS RESIDE ON THE SEF FILE FOR REPORTING BY HPA, 
*         WITH AN RP DEVICE TYPE AND A 63B RECORD TYPE. 
* 
* 
* MALET20     JMO    86/01/23 
*         MODSET CORRECTS MALET COMPILER TO TO SKIP MISSING LANGUAGE
*         COMPILERS FOR OFFLINE. PSR CMLA540. 
* 
* 
* MLD     JMO    86/01/23 
*         MODSET ADDS PERMANENT DEFINE FOR 895M TO ASSEMBLE THE CORRECT 
*         PRODUCT OVERLAYS FOR 895 DISK. PSR CMLA538. 
* 
* 
*         PSR CML0667 
* HPA1    REF 86/01/16
* HPA22   MODSET CML0667 PROVIDES NEW REPORT FORMATS FOR DISK ADDRESS ERRORS
* HPA3    THAT EXCLUDE PATH DATA (CHANNEL AND UNIT) AND DETAIL STATUS, WHICH
* HPA31   ARE NOT AVAILABLE FOR THE OS TO LOG IN THE BML OR FOR HPA TO REPORT.
* HPA34   HPA HAS NOT EXCLUDED THESE FIELDS PREVIOUSLY, ON THE SUPPOSITION
*         THAT THESE FIELDS WOULD BE DEVOID OF DATA.  HOWEVER, THESE FIELDS ARE 
*         BEING LOGGED BY THE OS WITH UNDEFINED DATA AND THE APPEARANCE OF THIS 
*         UNDEFINED DATA IN HPA REPORTS IS MISLEADING.  SECONDLY, THE MODSET
*         REMOVES THE EQ FIELD FROM DISK REPORTS (EQ IS NOT RELEVANT FOR DISKS) 
*         AND ADDS THE PP TO THE DETAIL LINE IN DISK REPORTS. 
* 
* 
* DSPLOT  DDC    85/12/18 
*         THIS MODSET CHANGES DSPLOT IN ORDER TO USE SORT/ MERG 
*         VERSION 5.
*         THIS MOD ALSO FIXES A PROBLEM WHICH LEFT ERROR CODES
*         OF 40,41 AND 42 FROM BEING REPORTED AGAINST A DISK
*         UNIT IN REPORTS 1 THROUGH THREE.
* 
* 
* CMLINST     JMO    86/01/28 
*         MODSET CORRECTS CMLINST TO NOT DO A LIBGEN IF NOS 4 OR 5 IS 
*         DEFINED AS SYSVER. PSR CML0779. 
* 
* 
* CMLINST     JMO    86/01/27 
*         MODSET CORRECTS CMLINST TO ERROR EXIT ON ASSEMBLY OR COMPILE
*         ERRORS. PSR CML0780.
* 
* 
* HISTORY LJC   86/02/04
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L185*. 
* 
* 
* 
* 
*         PSR CMLA395 
* HPA35   GFS 86/02/07
*         MODSET CMLA395 CHANGES THE PORT VS. HOUR OF DAY GRAPH TO THE
*         ACTIVE DEVICES VS. HOUR OF DAY GRAPH. THE SCNQ MESSAGE IS 
*         USED FOR INPUT DATA INSTEAD OF THE SCLI MESSAGE.
* 
* 
*         PSR CMLA394 
* HPA35   GFS 86/02/07
*         MODSET CMLA394 ALLOWS HPA TO REPORT 2550 BLOCK AND CHARACTER
*         COUNTS IN DECIMAL RATHER THAN HEX, AND TO PROVIDE THE ACTUAL
*         CHARACTER COUNTS RATHER THAN COUNTS THAT HAVE BEEN DIVIDED
*         BY 32 IN CCP. 
* 
* 
*         PSR CMLA552 
* HPA32   GFS 86/02/28
*         MODSET CMLA552 SUPPORTS BML MESSAGES ISSUED BY LOADBC WHEN AN 
*         ERROR IS DETECTED LOADING CONTROLWARE. DEVICE TYPE IS CH AND
*         RECORD TYPE IS 01B. 
* 
* 
* IST     DHW    86/02/14 
*         MODSET CORRECTS MISC. DOCUMENTATION ERRORS
*         AND ERROR MESSAGES. PSR CMLA543.
* 
* 
* SBP     JMO    86/02/24 
*         MODSET CORRECTS SBP FOR THE INCREASE LENGTH IN THE 77 TABLES FOR
*         DEMOT. PSR CMLA550. 
* 
* 
* ITU     JMO    86/02/20 
*         MODSET CORRECTS ITU14 TO NOT PRINT AL TOO LOW IF IT ISNT. 
*         PSR CMLA549.
* 
* 
* MALET10     JMO    86/02/18 
*         MODSET CORRECTS UPPU16 TO HANDLE PICTURE COMMAND FOR 16BIT. 
*         PSR CMLA548.
* 
* 
* MALETPP     JMO    86/01/29 
*         MODSET ADDS READCB AND WRITECB COMMANDS TO FSD2 LANGUAGE. 
*         PSR CMLA541.
* 
* 
* ISD1     JMO    86/01/29
*         MODSET ADDS READCB AND WRITECB TO ISD1 PRODUCT OVERLAY. 
*         PSR CMLA541.
* 
* 
* DTI     JMO    86/02/03 
*         MODSET ADDS WRITE READ ADAPTER BUFFER TEST FOR ISD TO DTI.
*         PSR CMLA541.
* 
* 
* CDCMLI1     JMO    86/01/15 
*         MODSET ADDS COMDECK CDCMLI1 TO CMLPL FOR CMLINST. 
*         THESE ARE VALID DECK NAMES. PSR CMLA535.
* 
* 
* CDCMLI2     JMO    86/01/15 
*         MODSET ADDS COMDECK CDCMLI2 TO THE CMLPL FOR CMLINST. 
*         THESE ARE VALID TEST NAMES. PSR CMLA535.
* 
* 
* CMLINST     JMO    86/01/15 
*         MODSET ADDS TESTS IST FOR 639 TO CMLINST. 
*         PSR CMLA535.
* 
* 
* DKDATA  DDC    02/19/86 
*         MODSET CORRECTS ERROR CODE SC206 TO BE SC602 IN DKDATA. 
* 
* 
* COMMTAL RVS   86/03/03
*          ADDS COMMON DECK COMMTAL TO CML 3.2
* 
* COMMTDC RVS   86/03/03
*          ADDS COMMON DECK COMMTDC TO CML 3.2
* 
* CMLA547 RVS    86/02/28 
*         MODSET CMLA547 ADDS THE FOLLOWING TO CMLINST: 
*          - CMSI INTERFACE TO CMLINST. 
*          - COMDECK COMMTAL TO CONTAIN VALID MALET ACCESS
*            LEVELS TO SUPPORT CMSI.
*          - COMDECK COMMTDC TO CONTAIN VALID DEVICE CODES
*            TO SUPPORT CMSI. 
* 
* 
* HISTORY LJC   86/03/05
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L186*. 
* 
* 
* 
* 
*         PSR CMLA557 
* COMHPA- REF 85/12/16
*   ERT   MODSET CMLA557 PROVIDES HPA SUPPORT OF 990 DFT ENHANCEMENTS 
* HPA312  FOR NOS 2.5.1 L658.  ENHANCEMENTS CONSIST OF TWO NEW PROCESSOR
* HPA313  ERRORS: 
*         1) CATASTROPHIC RECOVERY ERROR    - BML SYMPTOM CODE 1013B; 
*         2) CORRECTED ERROR W CACHE RELOAD - BML SYMPTOM CODE 1014B. 
* 
* 
*         PSR CMLA468 
* HPA312  GFS 86/02/07
*         MODSET CMLA468 ENABLES HPA TO REPORT THE BARREL AND PP NUMBER 
*         FOR ALL BITS OF THE FS1 REGISTER. 
* 
* 
*         PSR CMLA463 
* HPA312  GFS 86/02/07
*         MODSET CMLA463 ENHANCES HPA TO ENABLE REPORTING MULTIPLE PP'S 
*         IF MORE THAN ONE PP BIT IS SET IN FS1.
* 
* 
*         PSR CMLA398 
* HPA312  GFS 86/03/10
*         MODSET CMLA398 ENHANCES HPA TO CHECK TO SEE IF THEIR ARE ANY
*         FAULT STATUS REGISTER ERRORS BEFORE OUTPUTING ANY HEADERS. IF 
*         THERE ARE NONE THEN THE SUBHEADERS ARE NOT PRINTED. 
* 
* 
*         PSR CMLA545 
* HPA1    GFS 86/03/05
*         MODSET TO CORRECT HISTORY WINDOW DISPLAYED FOR PARAMETER
*         HW=XXX. 
* 
* 
* ITU     JMO    86/03/18 
*         MODSET CORRECTS ITU TO LINK MODULES 00 THROUGH 11.
*         PSR CMLA560.
* 
* 
* FMC     JMO    86/03/11 
*         MODSET CORRECTS FMC TO EXIT MODULES 08 AND 09 IF PARAMETER P8 
*         IS NOT SET FOR 865/875/700 OR 815/825. PSR MSLA523. 
* 
* 
* CMLA553    RVS    86/03/13
*         THIS MODSET ADDS NPA SUPPORT TO CMSI/CMLINST
*         MODSET ADDS PROCS CMSI120,CMSI121,AND CMSI126.
* 
* 
* CMLINST     JMO    86/03/13 
*         MODSET CORRECTS CMLINST PROCS FOR ERRORS. 
*         PSR CMLA559.
* 
* 
* MALET     JMO    86/03/21 
*         MODSET CORRECTS MALET DOCUMENTATION FOR CEVAL RESPONSE CODES. 
*         PSR CMLA572.
* 
* 
* IST     JMO    86/03/19 
*         MODSET CORRECTS IST TO DISPLAY B8-B15 UPON ERROR. 
*         PSR CMLA564.
* 
* 
* CMLA554    RVS    86/03/10
*          THE CMSI FEATURE ADDED TO CMLINST USED FEATURES
*          OF NOS 2.4.1 CCL.   THESE MUST BE CHANGED TO BE
*          COMPATIBLE WITH NOS 2.3. 
*         ADD USE OF 'SYSVER' IN NOSDEF DECK
*         FOR CMLINST UPDATE. 
* 
* 
* CMLA555    RVS    86/03/31
*        MODSET CMLA555 CONTAINS SEVERAL FIXS FOR 
*        THE CMSI FEATURE ADDED TO CMLINST AT CML 
*        LEVEL 186. 
* 
* 
* CMLA570     RVS    86/03/24 
*         THIS MODSET FIXES COMMON DECK COMMTAL TO ACCEPT 
*         LEADING ZEROS ON MALET ACCESS LVLS. 
* 
* 
*        PSR=CMLA569
* TIO    GLG  86/03/21
*        MODSET CORRECTS FORMAT USED WHEN MAXREC IS LESS THAN MINREC. 
* 
* 
*         PSR CMLA330 
* HPA     GFS 86/03/13
* HPA312  MODSET CMLA330 UPDATES HPA TO ENABLE THE REPORTING OF 810/830 
*         AND 65810/65830 IOU ERRORS. 
* 
* 
*         PSR CMLA323 
* HPA37   GFS 86/03/21
*         MODSET CMLA323 UPDATES THE ERROR TABLE FOR MSS ERRORS TO
*         CORRESPOND TO THE LATEST MICROCODE. 
* 
* 
*         PSR CMLA561 
* HPA311  GFS 86/03/25
*         MODSET CMLA561 CORRECTS AN ERROR IN REPORTING THE REGISTER
*         NUMBER IN THE ANALYSIS REPORTS FOR 840/845/850/855/860
*         PROCESSORS, INTRODUCED IN CML L179. 
* 
* 
* MALET     JMO    86/03/27 
*         MODSET ALLOWS MALET CPU PRIORITY TO BE CHANGED. 
*         PSR CML0792.
* 
* 
*         PSR CMLA568 
* COMHPA- REF 86/03/13
*   ERT   MODSET CMLA567 PROVIDES HPA SUPPORT FOR RMS RAM ENHANCEMENTS PHASE
* HPA312  II.  THIS EFFORT INVOLVES SUPPORT OF LOGGING COMMONALITY FOR THE
*         DEMA/1HP AND 895/1MX DRIVERS, SO THAT ERROR MESSAGES IN THE BML,
*         ERROR LOG AND DAYFILE WILL CORRESPOND TO MESSAGES PREVIOUSLY LOGGED 
*         BY 6DI FOR THE 844/885/FSC/ISD.  ALSO, SUPPORT PROVIDED AT PHASE I
*         FOR BUFFERED DEVICES IS INCLUDED AT PHASE II FOR BUFFERED DEVICES 
*         (DEMA AND 819. )  THIS SUPPORT INCLUDES AUTOMATIC TRACK FLAWING,
*         CHANNEL DOWN, EQ DOWN/OFF AMD DATA VERIFICATION ERROR.
* 
* 
* ITW     RDS   86/03/25. 
* 
*         THIS MODSET INSERTS DECK ITW INTO THE CL LIBRARY.  ITW
*         IS THE 16-BIT VERSION OF ITU, THE INTELLIGENT SMALL 
*         MAGNETIC TAPE (ISMT) UTILITY. 
* 
* 
* CMLA573A  RVS   86/03/28
*         CMLA573A MAKES DECK CMLIDCD2 MORE USABLE BY MORE
*         PROCEDURES IN CMLINST LIBRARY.
* 
* 
* CMLA573B  RVS   86/03/28
*         CMLA573B REPAIRS CHANGES MADE IN CMLA573A 
*         BECAUSE OF COMMON DECK CHANGES. 
* 
* 
*         PSR CML0784 
* HPA314  GFS 86/03/28
*         MODSET TO 990 MEMORY CODE TO CHANGE CMC BANK TO CSU BANK
*         TRANSLATION (COLUMN ONE). 
* 
* 
* CMLA575   RVS    86/04/02 
*          MODSET CMLA575 FIXS A CONFLICT BETWEEN 
*          THE UPDATE NOS COMMAND AND THE CMLINST 
*          PROCEDURE FILE UPDATE.  THIS CAUSED THE
*          PROCEDURES TO ABORT WHEN CMLINST IS USED 
*          AS A GLOBAL LIBRARY. 
*          THIS ANSWERS PSR CMLA575.
* 
* 
* CMLINST     JMO    86/04/04 
*         MODSET CORRECTS ANALDUMP TO HANDLE LABELED TAPES. 
*         PSR CMLA577.
* 
* 
* MALET11     JMO    86/03/27 
*         MODSET CORRECTS MALET11 TO RETURN EQUIPMENT EVEN IF NOT IN EST. 
*         PSR CMLA574.
* 
* 
* HISTORY GLG   86/04/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L187*. 
* 
* 
* 
* 
* CMSI    RVS    86/03/24 
*         THIS MODSET CORRECTS SEVERAL PROBLEMS 
*         IN CMSI/CMLINST FOUND DURING PRERELEASE 
*         TESTING.
* 
* 
* CMSI     RVS     86/04/08 
*          THIS MODSET CORRECTS SEVERAL PROBLEMS
*          IN CMSI/CMLINST FOUND DURING PRERELEASE
*          TESTING. 
* 
* 
*         PSR CMLA580 
* HPA38   REF 86/04/03
* HPA310  MODSET CMLA567 SUPPORTS THE DFT MULTIPLE OCCURRENCE FLAG. 
* HPA311
* HPA312
* HPA313
* HPA314
* 
* 
*         PSR CMLA527 
* HPA38   GFS 86/04/10
*         MODSET CMLA562 CORRECTS AN ERROR IN HPA38 SO THAT THE ERROR 
*         COUNT FOR BANK 7 IS REPORTED UNDER THE SUBHEADER
*         "MEMORY ERRORS" IN THE UNIT ANALYSIS REPORT.
* 
* 
* CMSI     RVS     86/04/14 
*          MODSET CMLA588 FIXS SEVERAL PROBLEMS 
*          IN CMSI/CMLINST. 
* 
* 
* CMSI    RVS     86/04/14
*         MODSET CMLA609 FIXES PROC CMSI220 TO
*         CORRECTLY FIND THE CPU TEST CU8.
*         AND ADDS A TEST VS MACHINE GRID TO THE
*         HELPS.
* 
* 
* CMSI      RVS     86/04/16
*           MODSET CMLA613 ADDS THE PARAMETER 
*           TDEN FOR TAPE DENSITY TO THE DUMP 
*           PROCS. IN CMSI/CMLINST. 
* 
* 
*         PSR CMLA615 
* HPA312  REF 86/04/16
* HPA313  MODSET CMLA615 SUPPORTS NEW I4 DFT ANALYSIS CODES, WHICH
* HPA314  IDENTIFY ERRORS SPECIFIC TO THE CIO PP. 
* 
* 
* T7X     JMO    86/04/18 
*         MODSET CORRECTS T7X MODULE 980 TO DISPLAY CORRECT RECORD
*         COUNT. PSR CMLA617. 
* 
* 
* CMSI    RVS    86/04/21 
*         THIS PSR ADDS USER SUPPLIED PROLOG
*         SUPPORT TO CMSI.   THIS BECOMES AN OPTION 
*         TO BE SUPPLIED AT INITIALIZATION TIME.
* 
* 
* CMSI    RVS   86/04/18
*         MODSET CMLA618 ADDS SETTL LINE
*         TO THE REGEN GENERATE JOB DECK TO 
*         PREVENT ABORTS ON TIME LIMIT. 
* 
* 
* CMSI    RVS   86/04/18
*         MODSET CMLA169 FIXS A RESOURCE PROBLEM
*         IN THE REGEN BATCH JOB. 
* 
* 
* CMSI    RVS     86/04/18
*         MODSET CMLA620 FIXS A TIME LIMIT
*         PROBLEM IN THE TIO BATCH JOB. 
*         TIME LIMIT IS SET BASED ON THE
*         NUMBER OF PASSES TO BE RUN. 
*         - ALSO FIXS FILE ASSIGNMENTS IN 
*         REGEN BATCH JOBS. 
* 
* 
* CMSI    RVS    86/04/28 
*         CORRECT MENU ENTRY FOR MCDUMP/MCCOMP
*         IN CMSI300. 
* 
* 
* CMSI    RVS    86/04/23 
*         MODSET CMLA627 PROVIDES A MEANS TO  PRINT 
*         LISTINGS PRODUCED BY CMLUTIL. 
* 
* 
* CMSI    RVS   86/04/25
*         CHANGES TO NPA PROCEDURES REQUIRE CHANGES TO
*         THE CMSI INTERFACE TO NPA.
* 
* 
* CMSI    RVS   86/04/29
*         FIX ALL PROCS. TO ALLOW 3 DIGIT CIPLVL ENTRIES. 
* 
* 
* CMSI    RVS   86/04/27
*         MALET PROCS DO NOT RETURN PRE-ASSIGNED TAPE DRIVES. 
* 
* 
*         PSR CMLA632 
* HPA38   REF 86/04/18
* HPA310  MODSET CMLA632 PROVIDES SUPPORT FOR DFT SEQUENCE NUMBERS AND
* HPA311  DFT ANALYSIS CODES.  THE DETAILED REPORTING OF EACH MAINFRAME 
* HPA312  ERROR WILL INCLUDE THE SEQUENCE NUMBER AND ANALYSIS CODE
* HPA313  ASSIGNED BY DFT.  THIS EFFORT ALSO INCLUDES THE IMPLEMENTATION
* HPA314  OF DFT ANALYSIS CODES DESCRIPTIVE TEXT WHICH HAS BEEN MASSAGED
*         FOR COMMONALITY.
* 
* 
*         PSR CMLA621 
* HPA315  GFS 86/02/28
*         MODSET TO CYBERPLUS CODE TO USE 64 BITS/HPP IN  ERROR DETECT
*         BOARD LOOP INSTEAD OF 32 BITS/HPP.
* 
* 
* MLD     JMO    86/04/02 
*         MODSET CORRECTS MLD INTERNAL DOCUMENTATION FOR SCRATCH
*         FILE WORKING BUFFER LENGTH. PSR CMLA576.
* 
* 
* SBP     JMO    86/04/02 
*         MODSET CORRECTS SBP INTERNAL DOCUMENTATION FOR SCRATCH
*         FILE WORKING BUFFER LENGTH. PSR CMLA576.
* 
* 
* DFU      RDS    86/04/21
*          MODSET CMLA626 ADDS TO DFU THE CAPABILITY TO WRITE 
*          CCC CONTROLWARE (MA464) TO THE 895 DISK.  MODULES ADDED
*          ARE DFU21, DFU21A AND DFU21B.
* 
* 
* ASSYTAG     JMO    86/04/21 
*         MODSET CORRECTS ASSYTAG FOR NOS 4 5 AND 6 DEFINES.
*         PSR CMLA625.
* 
* 
* FMD     JMO    86/04/18 
*         MODSET CORRECTS FMD22 FOR THE BUS OUT DATA FOR DRIVE
*         COMMANDS. PSR CMLA624.
* 
* 
* DFU     JMO    86/04/15 
*         MODSET CORRECTS DFU DOCUMENTATION AND MODULE 17 TO CLARIFY
*         FORMATTING OF THE RESERVED CYLINDER. PSR CML0794. 
* 
* 
* CMLA638      RVS    86/05/12
*           THIS MODSET FIXES DAYFILE MESSAGES TO 
*           NOT GET PARAMETER SUBSTITUTION. 
* 
* 
* CMLA640   RVS   86/05/02
*        THIS MODSET CORRECTS SEVERAL PROBLEMS
*        IN THE INITIALIZATION ROUTINES.
* 
* 
* CMSI   RVS   86/05/04 
*       ADD ADDITIONALINFORMATION IN THE HELPS
*       AS TO THE NEED FOR FILE INSTMDS.
* 
* 
* CMSI    RVS    86/05/04 
*       FIX CONFLICT BETWEEN CONTROL CARD "LOAD" AND
*       CMLINST PROCEDURE "LOAD"
*       CHANGE PROCEDURE NAME FROM LOAD TO XLOADY.
* 
* CMSI   RVS   86/05/04 
*       FIX CMLUTIL / CMSI TO ONLY ASK FOR OUTPUT 
*       LISTING DISPOSABLE ONCE.
* 
* CMLA644   RVS   86/05/02
*         MODSET CMLA644 ALLOWS THE USE OF PARAMETERS 
*         FOR CPU TEST EC3 AND EC8. 
* 
* 
* CMSI    RVS   86/05/04
* 
*        FIX UNCOMMENTED '?' IN PROC 420. 
* 
* 
* CMLA649     RVS     86/05/02
*         THIS MODSET ADDS MISSING HELPS
*         TO SEVERAL PROCEDURES.
* 
* 
* HISTORY LJC   86/05/05
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L188*. 
* 
* 
* 
* 
* CMLINST   RVS   86/05/06
*         FIX CMLUTIL TO FIND CMLINST PROCEDURE FILE
*         IF THAT FILE IS STORED AS AN INDIRECT FILE. 
* 
* 
* CMSI   RVS   86/05/06 
*         FIX HPA STATMENTS TO BE CONSISTANT
*         BETWEEN BATCH RUNS AND INTERACTIVE RUNS.
* 
* 
* CMSI   RVS   86/05/06 
*        REGEN BATCH JOB RUNS TO TIME LIMIT 
* 
* 
*         PSR CMLA636 
* HPA315  GFS 86/04/30
*         MODSET CMLA636 ADDS THE JOB NAME TO THE CYBERPLUS DETAIL REPORT.
* 
* 
* CMSI    RVS    86/05/06 
*       MST WITH DEFAULT PARAMETERS RUNS
*       TO TRACK LIMIT ON 885 (DQ) DEVICES. 
* 
* 
* CMSI   RVS   86/05/07 
*        THIS MODSET CORRECT SEVERAL PROBLEMS 
*        FOUND DURING TESTING.
* 
* 
*         PSR CMLA635 
* HPA38   REF 86/04/18
* HPA310  MODSET CMLA635 SUPPLIES THE CPU FAULT CODE IN THE DETAIL REPORT 
* HPA311  FOR 810/815/825/830/835/840/845/850/855/860 PROCESSOR ERRORS. 
* HPA312
* 
* 
*         PSR CMLA634 
* HPA314  GFS 86/04/28
*         MODSET CMLA634 CHANGES THE FORMAT THE DETAIL REPORT USES
*         TO REPORT IOU ERRORS WITH FAULT CODES.
* 
* 
* CMLINST     JMO    86/05/15 
*         MODSET CORRECTS CMLINST UTILITY PROC TO POST A MORE 
*         INFORMATIVE MESSAGE FOR GENERAL INFO. PSR CMLA654.
* 
* 
*         PSR CMLA527 
* HPA314  GFS 86/04/08
*         MODSET CMLA527 SUPPORTS THE 64K/256K MEMORY CHIP CAPABILITY 
*         OF INTERFACING MEMORY SIZES UP TO 512 MBYTES FOR 990 MEMORY.
* 
*         IT ALSO CHECKS THE VALID DATA BIT IN THE A0-A7 REGISTERS
*         AND SWAPS THE SYNDROME AND BIT IN THE 16K REPORTS.
* 
* 
*         PSR CMLA662 
* HPA310  GFS 86/05/09
* HPA312  THE FOLLOWING CHANGES ARE TO CORRECT FRU'S OR ERROR MESSAGES
*         ACCORDING TO ENGINEERING SPEC. 19267043, REV. A, 12/23/85.
* HPA38   VALID BIT CHECK FOR REGISTERS A0 AND A4 - 855.
* 
* 
* CMSI   RVS    86/05/06
*         CORRECT CMSI TO ALLOW FEP TO RUN AT AL=3. 
* 
* 
* CMSI    RVS    86/05/04 
*       FIX CONFLICT BETWEEN CONTROL CARD "LOAD" AND
*       CMLINST PROCEDURE "LOAD"
*       CHANGE PROCEDURE NAME FROM LOAD TO XLOADY.
* 
* CMSI    RVS    86/05/13 
*          CORRECT GETATT PROCEDURE CALL ADDED BY 
*          MODSET CMLA648 
* 
* 
* CMSI   RVS   86/05/15 
*          ADD DAYFILES TO BATCH LISTINGS.
* 
* 
*         PSR CMLA663 
* HPA312  REF 86/05/19
*         MODSET CMLA663 CORRECTS A COMPILATION ERROR CAUSED BY THE COLLISION 
*         OF 2 MODSETS FOR THE SAME BUILD CYCLE.
* 
* 
* CMSI    RVS    86/05/21 
*         CORRECT BATCH JOB COMMAND SEQUENCE TO 
*         PREVENT USER DIRECTIVE ERROR. 
* 
* 
*         PSR CMLA669 
* HPA311  REF 86/05/16
*         MODSET CMLA669 SUPPRESSES 845/855 AND 840/850/860 PFS BITS WHICH
*         INDICATE A FALSE ERROR.  SPECIFICALLY, PFS 80-1 AND PFS 86-45,
*         WHEN THEY ARE THE ONLY PFS BITS SET, SHOULD BE DISABLED IN HPA
*         REPORTS.
* 
* 
* CMLINST   RVS   86/05/21
*         CORRECT CONFLICT BETWEEN UPDATE PROCEDURE ON CMLINST
*         AND UPDATE PRODUCT IN THE NOS SYSTEM. 
* 
* 
* CMSI    RVS    86/05/22 
*          FIX SEVERAL PROBLEMS IN CMSI ROUTINES. 
*          - CHANGE CIP LEVEL REFERENCES TO CIP VERSION REFS. 
*          - CAUSE ALL DUMP PROCS. TO UNLOAD TAPE WHEN FINISHED.
*          - BETTER DEFINE RESOURCE REQUIREMENTS FOR REGEN. 
*           - REORDER HPA DEVICE CODES IN CMSIHP1.
* 
* 
* CMSI   RVS  86/05/27
*       CORRECT PARAMETER PROBLEM IN PROC.DSDIX2. 
* 
* 
*         PSR CMLA672 
* HPA311  REF 86/05/16
* HPA310  MODSET CMLA672 CORRECTS THE I1/I1CR DETAIL REPORT FORMAT. 
* HPA312
* 
* 
*         PSR CMLA677 
* HPA     REF 86/04/08
*         MODSET CMLA677 MAKES A CORRECTION TO CMLA669, WHICH SUPPRESSES
*         P3/P3CR FALSE HW ERRORS.
* 
* 
* CMLINST   RVS   86/05/30
*        CORRECT INCOMPATIBILITY BETWEEN NOS AND NOSBE. 
*        NOSBE LEVEL 631 DOES NOT ACCEPT $ AS FIRST CHAR. 
*        OF A CONTROL CARD. 
* 
* 
* T7X     JMO    86/05/16 
*         MODSET CORRECTS MISCELLANIOUS ERRORS IN T7X MODULES 83-93.
*         PSR CMLA665.
* 
* 
* CLM     JMO    86/05/14 
*         MODSET ADDS AN AUTOLOAD CONTROLWARE MODULE TO CLM.
*         PSR CML0795.
* 
* 
* CCM     JMO    86/05/14 
*         MODSET ADDS AN AUTOLOAD CONTROLWARE MODULE TO CCM.
*         PSR CML0795.
* 
* 
* MLD     JMO    86/05/20 
*         MODSET ADDS THE DEFINE OF ICI TO THE CML PL.
*         PSR CMLA664A. 
* 
* 
* LOW  HWW   86/05/20.
* 
*         THIS MODSET MODIFIES THE  PRODUCT OVERLAY TO MAKE IT
*         COMPATIBLE WITH MLD/VE AND THE NOSVE ENVIRONMENT. 
* 
* 
* 67X  HWW   86/05/15.
* 
*         THIS MODSET MODIFIES THE  PRODUCT OVERLAY TO MAKE IT
*         COMPATIBLE WITH MLD/VE AND THE NOSVE ENVIRONMENT. 
* 
* 
* 844HT  HWW   86/05/15.
* 
*         THIS MODSET MODIFIES THE  PRODUCT OVERLAY TO MAKE IT
*         COMPATIBLE WITH MLD/VE AND THE NOSVE ENVIRONMENT. 
* 
* 
* 844FT  HWW   86/05/15.
* 
*         THIS MODSET MODIFIES THE  PRODUCT OVERLAY TO MAKE IT
*         COMPATIBLE WITH MLD/VE AND THE NOSVE ENVIRONMENT. 
* 
* 
* LSFMD1  HWW   86/05/15. 
* 
*         THIS MODSET MODIFIES THE  PRODUCT OVERLAY TO MAKE IT
*         COMPATIBLE WITH MLD/VE AND THE NOSVE ENVIRONMENT. 
* 
* 
* LSFMD2  HWW   86/05/15. 
* 
*         THIS MODSET MODIFIES THE  PRODUCT OVERLAY TO MAKE IT
*         COMPATIBLE WITH MLD/VE AND THE NOSVE ENVIRONMENT. 
* 
* 
* ISD  HWW   86/05/15.
* 
*         THIS MODSET MODIFIES THE  PRODUCT OVERLAY TO MAKE IT
*         COMPATIBLE WITH MLD/VE AND THE NOSVE ENVIRONMENT. 
* 
* 
* ISD1  HWW   86/05/16. 
* 
*         THIS MODSET MODIFIES THE  PRODUCT OVERLAY TO MAKE IT
*         COMPATIBLE WITH MLD/VE AND THE NOSVE ENVIRONMENT. 
* 
* 
* MLDVE   JMO    86/05/20 
*         MODSET ADDS DECK AAA TO CML 3.2.
*         PSR CMLA664 
* 
* 
* ICI     HWW    86/05/20 
*         MODSET ADDS DECK ICI TO CML 3.2.
*         PSR CMLA664 
* 
* 
* HISTORY LJC   86/06/02
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L189*. 
* 
* 
* 
* 
*         PSR CMLA674 
* HPA310  GFS 86/05/16
*         MODSET CMLA674 ENABLES HPA TO INTERPRET AND REPORT REGISTERS
*         81/91, 90, 92, AND 93 FOR THE 810/815/825/830/835.
* 
* 
*         PSR CMLA681 
* HPA314  GFS 86/06/11
*         MODSET CMLA681 CORRECTS THE 64K/256K BIT DESIGNATION AND
*         ALLOWS DIFFERENT TYPES OF MEMORY CHIPS TO BE ANALYZED IN
*         THE SAME REPORT.
* 
* 
* MALET     JMO    86/06/09 
*         MODSET CORRECTS MALET TO ABORT AFTER RECOVER PERIOD IF THE
*         TERMINAL IS DISCONNECTED. PSR CML0808.
* 
* 
*         PSR CMLA685 
* HPA     REF 86/06/09
* HPA3    MODSET CMLA685 PROVIDES HPA SUPPORT FOR HYDRA.
* HPA34 
* 
* 
* MLDVE  HWW   86/07/08.
* 
*         COMMENTS
*         COMMENTS
*         COMMENTS
* 
* 
* HISTORY LJC   86/07/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L190*. 
* 
* 
* 
* 
*         PSR CMLA691 
* HPA3    REF 86/06/25
* HPA34   MODSET CMLA691 PROVIDES HPA SUPPORT FOR HYDRA DIAGNOSTICS.
* 
* 
*         PSR CMLA692 
* HPA     REF 86/07/22
* HPA3    MODSET CMLA692 CHANGES HYDRA PRODUCT ID FROM 896-42 TO 887. 
* HPA34 
* 
* 
*         PSR CMLA696 
* HPA38   REF 86/07/23
*         MODSET CMLA696 CORRECTS THE M1, M1CR, M2, M3 AND M3CR MEMORY
*         REPORTS.  AN ERROR WAS INTRODUCED BY MODSET CMLA662 (CML L186)
*         WHICH ATTEMPTED TO CHECK THE VALID REGISTER BIT.  THE REMEDY
*         INVOLVES PULLING ALL THE CMLA662 CODE FROM HPA38.  USERS CAN
*         INTERPRET THE ERROR ADDRESS FROM THE SNAPSHOT OF REGISTERS
*         PROVIDED BY HPA VIA THE DX (DETAIL EXTENDED) PARAMETER, UNTIL 
*         THIS CORRECTION IS AVAILABLE IN CML L192 OR IT IS INTEGRATED
*         FROM SOLVER.
* 
* 
*         PSR CMLA701 
* HPA3    REF 86/07/31
* HPA34   MODSET CMLA701 PROVIDES CORRECTIVE CODE FOR HYDRA IHD/DEVICE
*         STATUS. 
* 
* 
* ISW     CAE    86/07/23 
*         MODSET ADDS DECK ISW TO CML 3.2.
* 
* 
* FMD     JMO    86/06/09 
*         MODSET CORRECTS FMD MODULE 70 TO RETRY IF A BAD VALUE IS
*         ENCOUNTERED DURING SEEK TIMING. PSR CML0798.
* 
* 
* ISD1     RDS    86/06/24
*          MODSET CMLA682 CHANGES COMDECK ISD1 TO ALLOW RETRY OF
*          THE SEEK FUNCTION WHEN 0010 STATUS IS RECEIVED FROM THE
*          895 STORAGE DIRECTOR.
* 
* 
* DTI      RDS    86/06/24
*          MODSET CHANGES MODULE DTI11 TO ALLOW CORRECT ERROR 
*          REPORTING IN THE CASE OF A WRITE COMMAND ABORT.
* 
* 
* D639    CAE    86/07/28 
*         MODSET ADDS DECK D639 TO CML 3.2 FRO MLDVE. 
* 
* 
* MLDVE  HWW   86/07/25.
* 
*         THIS MODSET CORRECTS PROBLEM IN RANDOM ROUTINE WHICH CAUSED 
*         ISW TO FAIL IN MODULE 13. 
* 
* 
* MLD     JMO    86/07/28 
*         MODSET ADDS PERMANENT DEFINE FOR 639 MLDVE. 
*         PSR CMLA697.
* 
* 
* MALET2F     JMO    86/08/07 
*         MODSET CORRECTS DECKS MALET2F-MALET2P TO DISPLAY THE CORRECT VERSION
*         ON A CATALOG. PSR CMLA702.
* 
* 
* HISTORY LJC   86/08/13
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L191*. 
* 
* 
* 
* 
*         PSR CML0811 
* HPA     REF 86/08/05
* HPA3    MODSET CML0811 PROVIDES HPA SUPPORT FOR:  
* HPA32   1) CONDITIONAL HANG SOFTWARE ERRORS (MSGID 411B); 
* HPA5    2) DUAL STATE CM ASSIGNMENT/RETURN MESSAGES (MSGID 240B); 
*         3) DUAL STATE PP ASSIGNMENT/RETURN MESSAGES, PP DEADSTART 
*            ERRORS AND IDLE PP ERRORS (MSGID 240B).
* 
* 
* HPA312  GFS 86/08/18
*         MODSET CMLA705 REPLACES A VARIABLE CALL WITH THE CORRECT
*         VARIABLE SO THAT THE MFID IS PRINTED IN THE I1/I1CR/I2
*         REPORT. 
* 
* 
*         PSR CMLA703 
* HPA314  GFS 86/08/11
*         MODSET CMLA703 INITIALIZES A MEMORY LOCATION SO WHEN EITHER 
*         A DATA OUT OR PARTIAL WRITE PARITY ERROR OCCURS THE PRINT 
*         FORMAT STATEMENT WILL PRINT CORRECTLY 
* 
* 
* MLD     JMO    86/08/28 
*         MODSET CORRECTS MLD TO ABORT IF THE CHANNEL IS ASSIGNED TO NOSVE
*         WHEN RUNNING ON NOSBE. PSR CMLA707. 
* 
* 
* MALET10     JMO    86/07/31 
*         MODSET ADDS DEVICE CODE 53 FOR 698 9 TRACK TAPE.
*         PSR CMLA714.
* 
* 
* 67X     JMO    86/08/15 
*         MODSET ADDS DEVICE CODE OF 53 FOR 698 TAPE. 
*         PSR CMLA714.
* 
* 
* CLM     JMO    86/09/04 
*         MODSET ADDS DEVICE CODE 53 SUPPORT TO CLM.
*         PSR CMLA715.
* 
* 
* CCM     JMO    86/09/04 
*         MODSET ADDS DEVICE CODE 53 SUPPORT TO CCM.
*         PSR CMLA715.
* 
* 
* CMSI     RVS   86/08/28 
*         DKDATA AND OLDPD WILL NOT BE FOUND IF STORED
*         AS A DIRECT ACCESS FILES. 
* 
* 
* CMSI    RVS    86/09/02 
*        - CHANGE ALL "RETURN TO MAIN MENU OPTIONS TO 9.
*        - ADD CML LEVEL CMLLEV TAG THE SEVERAL MENUS FOR 
*          ASSEMBLY MARKER... 
* 
* 
* CMSI    RVS   86/08/28
*        MODSET CML0813 ALLOWS THE START-UP PROCEDURE 
*        TO HAVE A NAME OTHER THEN ONE THE SAME AS THE FILE 
*        NAME ON WHICH IT RESIDES. ( CHANGE 'BEGIN,UPFN,UPFN' 
*        TO  'BEGIN,,UPFN'  ).... 
* 
* 
* CMSI    RVS   86/08/28
*         CORRECT EDD TAPE LABEL STATEMENT FOR LATER THAN CIP 4 TAPES.
* 
* 
* ISD  HWW   86/09/10.
* 
*         THIS MODSET FIXES DRIVE ADDRESS PROBLEM WHICH OCCURS WHEN 
*         THE PRODUCT OVERLAY IS USED BY MALET VE.
* 
* 
* 
* ISD1  HWW   86/09/10. 
* 
*         THIS MODSET FIXES DRIVE ADDRESS PROBLEM WHICH OCCURS WHEN 
*         THE PRODUCT OVERLAY IS USED BY MALET VE.
* 
* 
* 
* CMSI    RVS   86/08/28
*         CORRECT EDD TAPE LABEL STATEMENT FOR LATER THAN CIP 4 TAPES.
*         THIS MODSET CORRECTS BAD MOD CMLA679. 
* 
* 
*         PSR CMLA717 
* HPA3    REF 86/09/05
* HPA34   MODSET CMLA717 PROVIDES HPA SUPPORT FOR:  
* HPA312  1) HYDRA READ/WRITE CONFIDENCE TEST RESULTS, LOGGED BY NOS; 
*         2) UPDATED LIST OF HYDRA FAULT CODES BEING LOGGED BY NOS; 
*         3) IDENTIFICATION OF I4 CHANNEL ERRORS AS EITHER NIO OR CIO;
*         4) SUPPRESSION OF I4 UNCORRECTED CHANNEL ERRORS (NIO/CIO PP)
*         FROM THE DETAIL REPORT.  THESE ERRORS ARE LOGGED EACH TIME A
*         HYDRA ISI TIMEOUT OCCURS AND CAN CONFUSE THE CE DUE TO THE
*         ABUNDANCE OF DATA. THESE ERRORS WILL CONTINUE TO BE SUMMARIZED
*         IN THE ANALYSIS REPORT. 
*         5) REPORT MODIFICATIONS FOR HYDRA ISI CHANNEL ERRORS AND
*         "INCORRECT UNIT SELECTED".
* 
* 
* HISTORY LJC   86/09/15
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L192*. 
* 
* 
* 
* 
* LSP     JMO    86/09/15 
*         MODSET CORRECTS LSP DOCUMENTATION FOR P9 TO INCLUDE 800 SYSTEMS.
*         PSR CMLA720.
* 
* 
* CMSI    RVS    09/02/86 
*        THIS MODSET CORRECTS AND ENHANCES THE CMSI PROCEDURES
*        AS FOLLOWS:  
*        - CAUSE CMSI430 (MODIFY CMLINST/CMSI) TO CALL CMSI500 TO 
*          REINITIALIZE CMSI FOLLOWING MODIFICATION.
*        - CORRECT VARIOUS DOCUMENTATION ERRORS. ADD DOCUMENTATION
*          WHERE NEEDED.
*        - FIX DAYFILE PROCESSING PROBLEM IN PROC CMSIEFC.
*        - ADD BANNER PAGES TO CPU TEST JOB OUTPUT. 
*       - RELEASE ADDITIONAL FILE LEFT BY HPA.
*       - TEST FOR INTERACTIVE USE IN PROCEDURE CMSI. 
*       - ADD TERMINAL MESSAGES TO HPA PROCEDURES.
*       - CHANGE CMSI111 MENU FORMAT. 
*       - FIX CMSIHP2 INPUT PROMPTS.
*       - ADD DATE/TIME LINE TO EST LISTING.
*       - ADD NOS VERSION ASSEMBLY INDICATOR TO THE HEADER. 
*       - ADD BANNER TO HARDCOPY EST PRINT. 
* 
* 
* CMSI     RVS   86/08/28 
*         CORRECT MODSET CMLA709....
*         DKDATA AND OLDPD WILL NOT BE FOUND IF STORED
*         AS A DIRECT ACCESS FILES. 
* 
* 
*         PSR CMLA727 
* HPA3    REF 86/09/25
* HPA34   MODSET CMLA727 INTRODUCES THRESHOLDING FOR DELAY STATUS ERRORS
*         FROM THE HYDRA ERROR LOG.  THE THRESHOLD IS HARD CODED AT 100.
*         THE THRESHOLD MAY BE DEACTIVATED BY THE "ST" PARAMETER, WHICH 
*         WILL ENABLE THE REPORTING OF ALL DELAY STATUS ERRORS. 
* 
* 
* ISD1     JMO    86/09/24
*         MODSET CORRECTS ISD1 SO FALSE CONTROL MODULE/DRIVE NOT CONNECTED
*         ERRORS DO NOT OCCUR WHEN THE DRIVE IS BUSY. PSR CMLA725.
* 
* 
* CMSI   RVS   86/09/03 
*       ADD AN LCN HOST TO HOST CONFIDENCE TEST TO CMSI.
*       PROCEDURES SUPPLIED BY THE LCN PROGRAMMING PROJECT. 
*           MFCHECK...
* 
* 
* CMSI    RVS    86/09/26 
*         THIS MODSET ADDS LIBEDIT DIRECTIVES TO PROC CMSI501 
*         TO DELETE THE CML INSTALLATION PROCEDURES BININST THRU
*         CML6.   THESE PROCEDURES ARE TYPICALLY NOT NEEDED AFTER 
*         THE FIRST INSTALLATION. 
* 
* 
* MLD     JMO    86/09/30 
*         MODSET CORRECTS SYSREAD TO TRANSFER 500B PP WORDS TO IB INSTEAD OF
*         505. PSR CML0832. 
* 
* 
* D88     JMO    86/10/01 
*         MODSET CORRECTS D8837 TO NOT GIVE FALSE ERRORS DURING HEAVY DISK
*         ACTIVITY. PSR CML0818.
* 
* 
* CMLINST     JMO    86/09/17 
*         MODSET ADDS SUPPORT TO CMLINST FOR 698 TAPES. 
*         PSR CMLA722.
* 
* 
* MLD     JMO    86/09/17 
*         MODSET ADDS ISD AND ISD1 PRODUCT OVERLAY SUPPORT TO NOSBE.
*         PSR CMLA722.
* 
* 
* DFU     JMO    86/07/30 
*         MODSET CORRECTS DFU DOCUMENTATION TO INDICATE ON A SHORT FORMAT 
*         ALL EXISTING DATA WILL BE DESTROYED. PSR CMLA698. 
* 
* 
* T7X  JMS   86/10/07.
* 
*         MODSET CMLA730 ADDS DIAGNOSTIC SUPPORT TO THE HITACHI MT300 
*         (200 IPS) AND MT100 (125 IPS) TAPE HANDLERS.
* 
* 
* 67X     JMO    86/10/03 
*         MODSET CORRECTS 67X FOR 698 TYPE DRIVES.
*         PSR CMLA731.
* 
* 
* HISTORY LJC   86/10/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L193*. 
* 
* 
* 
* 
*         PSR CMLA735 
* HPA     REF 86/10/10
* HPA21   MODSET CMLA735 PROVIDES AN HPA WORKAROUND FOR A SORT/MERGE 5
*         PROBLEM WHICH WIPES OUT SOME CM TABLES AND RESULTS IN AN HPA
*         FATAL CM ERROR.  SORT/MERGE 5 CLASSIFIES THIS CM ERROR AS A 
*         'HAIRY PROBLEM', BASED ON AN END CASE OF DATA.  ACCORDING TO
*         SVL, THE TIME IT COULD TAKE TO RESOLVE THIS PROBLEM IS UNJUS- 
*         TIFIABLE.  THIS MODSET CIRCUMVENTS THE CM ERROR BY: 
*         1) REMOVING THE SORT DIRECTIVE 'SM5FAST'; 
*         2) RESETTING THE MAXIMUM RECORD LENGTH TO 80 CHARACTERS FOR 
*         FILES BEING OUTPUT BY SORT (FILES SEF, FSORT AND TAPE3).
*         THIS HPA WORKAROUND TO AVOID THE CM ERROR HAS BEEN SUPPLIED BY
*         SVL.  HPA HAS GENERATED A CRITICAL PSR AGAINST SORT/MERGE 5 FOR 
*         THE CM ERROR (ST5A382).  WILL THIS SAME SORT PROBLEM IMPACT 
*         OTHER APPLICATIONS/SITES WHEN THE ENHANCED SORT IS RELEASED IN
*         NOS 2.5.2 L670? 
* 
* 
* CMLINST     JMO    86/10/08 
*         MODSET CORRECTS PROC INTINST HELP TO INCLUDE (*) IF NO CHARGE NUMBER
*         REQUIRED. PSR CML0826.
* 
* 
*         PSR CMLA733 
* HPA     REF 86/10/02
* HPA3    MODSET CMLA733 PROVIDES HPA SUPPORT FOR NOS SOFTWARE
* HPA32   INITIALIZATION: SYSTEM TITLE AND SYSTEM VERSION.
* 
* 
*         PSR CMLA734 
* HPA312  GFS 86/10/10
*         MODSET CMLA734 CORRECTS A PROBLEM WITH SOME MR DETAIL DATA BEING
*         PRINTED WHEN IT IS NOT CALLED FOR.
* 
* 
* CLM     JMO    86/10/20 
*         MODSET CORRECTS CLM TO HANDLE GENERAL STATUS OF 1000B FOR 698 
*         TAPE. PSR CMLA739.
* 
* 
* CCM     JMO    86/10/20 
*         MODSET CORRECTS CCM TO HANDLE GENERAL STATUS OF 1000B FOR 698 
*         TAPE. PSR CMLA739.
* 
* 
* CMSI   RVS   86/10/07 
*        ADD OPTION TO LCN PROCEDURES TO LIST LID/LCN 
*        CONFIGURATION. 
* 
* 
* CMSI     RVS    86/10/15
*         CORRECT COMMAND LINE DELETED BY MODSET
*         CMLA726.
* 
* 
* T7X  JMS   86/10/21.
* 
*         FIX AN END CASE PROBLEM IN THE LADDER TEST WHEN 
*         USING HITACHI UNITS.
* 
* 
* MLD     JMO    86/10/22 
*         MODSET CORRECTS THE CALLS IN MLD IF BOTH FSD AND 895M ARE DEFINED.
*         PSR CMLA742.
* 
* 
* CMSI    RVS    86/10/16 
*        ADD/CORRECT/MODIFY THE FOLLOWING AREAS OF CMSI.
*        - CHANGE MENU TEXT FOR OPTION NO.5 
*        - ADD TEXT TO THE HELP AREA OF CMSI200 NO.5
*        - ADD DOCUMENTATION TO CMSI200 INFO. BLOCK 
*        - ADD 698 TAPE UNIT TO DEVICES DISPLAY 
*        - CORRECT DOCUMENTATION ERROR IN CMSI240 OPTION 8. 
*          FIXS PSR CML0821.....
* 
* 
* ITU     JMO    86/10/02 
*         MODSET CORRECTS ITU NOT TO POST THE COMMAND THAT ABORTED ON MODULE
*         DETECTED ERRORS. PSR CML0825. 
* 
* 
* ITW     JMO    86/10/02 
*         MODSET CORRECTS ITW NOT TO POST THE COMMAND THAT ABORTED ON MODULE
*         DETECTED ERRORS. PSR CML0825. 
* 
* 
* ITU     JMO    86/10/21 
*         MODSET CORRECTS ITU98Q TO POST THE ISMT SUBSYSTEM MESSAGE.
*         PSR CML0827.
* 
* 
* ITW     JMO    86/10/21 
*         MODSET CORRECTS ITW98Q TO POST THE ISMT SUBSYSTEM MESSAGE.
*         PSR CML0827.
* 
* 
* ITU     JMO    86/10/01 
*         MODSET ADDS SELECTABLE DATA PATTERNS TO MODULE 11.
*         PSR CML0828.
* 
* 
* ITW     JMO    86/10/01 
*         MODSET ADDS SELECTABLE DATA PATTERNS TO MODULE 11.
*         PSR CML0828.
* 
* 
*         PSR CMLA743 
* HPA21   REF 86/10/20
* HPA3    MODSET CMLA743 PROVIDES MINOR HPA REFINEMENTS FOR HYDRA.
* HPA34   SPECIFICALLY: IT DEFINES THE ERRORS AS RECOVERED/UNRECOVERED
*         IN THE ANALYSIS REPORT; IT SUPPRESSES THE COUNT OF ERROR LOG
*         AND ERROR REGISTER IMAGE ENTRIES FROM THE ANALYSIS AND SUMMARY
*         REPORTS; IT CORRECTS PAGINATION IN ERROR LOG REPORTING. 
* 
* 
* MLD     JMO    86/10/31 
*         MODSET ADDS IPIDM DEFINE TO THE PERMANENT DEFINES.
*         PSR CMLA744.
* 
* 
* SKEDULR     JMO    86/10/29 
*         MODSET ADDS 1RUN COMMAND TO SKEDULR.
*         PSR CML0836.
* 
* 
*         PSR CMLA745 
* HPA310  REF 86/11/06
* HPA311  MODSET CMLA745 CORRECTS THE REPORTING OF FATAL CPU ERRORS FOR 
* HPA313  THE P1/P1CR/P2/P3/P3CR.  HPA HAD BEEN INCORRECTLY INTERPRETING
* HPA314  THE DFT CODE AS A CORRECTED ERROR.  MODSET ALSO SUPPRESSES THE
*         DUPLICATE TIME STAMPS FOR CONCURRENT ENVIRONMENT WARNING/ 
*         CLEAR MESSAGES. 
* 
* 
* HISTORY LJC   86/11/14
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L194*. 
* 
* 
* 
* 
*         PSR CMLA747 
* HPA     REF 86/10/20
* HPA2X   MODSET CMLA732 PROVIDES HPA SUPPORT FOR THE CMTS (CYBER 
* HPA3X   MAGNETIC TAPE SUBSYSTEM), PRODUCT ID 698.  SUPPORT IS ALSO
*         ADDED FOR ISMT AND FSC LATE DATA AND CORRECTED READ/WRITE 
*         ERRORS. 
* 
* 
*         PSR CMLA749 
* HPA32   REF 86/11/14
* HPA34   MODSET CMLA748 DROPS SUPPORT FOR THE THE BML FLAGS, LOGGED
*         BY THE 895 DRIVER 1XM, WHICH HAD BEEN UTILIZED BY NOS TO
*         CONVEY THE PRESENCE OR ABSENCE OF VALID STATUS CONDITIONS.
* 
* 
*         PSR CMLA750 
* HPA2    REF 86/11/21
* HPA21   MODSET CMLA750 PREVENTS COMPRESSION OF ERRORS FOR NON-TAPE
* HPA22   DEVICES (AN UNRELEASED PROBLEM).  MODSET ALSO UPDATES THE 
*         CMTS SENSE BITS, BY CALLING THE UNDEFINED BITS "SPARE", IN
*         ACCORDANCE WITH THE ERS.
* 
* 
* MALET     JMO    86/02/14 
*         MODSET ADDS SYSRDCM SYSWRCM AND SYSRWCM IN SUPPORT OF 895/DMA 
*         TO MALET. PSR CMLA751.
* 
* 
* MALET10     JMO    86/04/17 
*         MODSET ADDS SUPPORT TO MALET10 FOR 895/DMA. 
*         PSR CMLA751.
* 
* 
* MALET12     JMO    86/02/14 
*         MODSET ADDS SYSRDCM SYSWRCM AND SYSRWCM IN SUPPORT OF 895/DMA 
*         TO MALET12. PSR CMLA751.
* 
* 
* MALET20     JMO    86/02/14 
*         MODSET ADDS SYSRDCM SYSWRCM AND SYSRWCM AND SUPPORT OF 895/DMA
*         TO MALET 20. PSR CMLA751. 
* 
* 
* MLD     JMO    86/02/14 
*         MODSET ADDS SYSRDCM SYSWRCM AND SYSRWCM IN SUPPORT OF DMA/895 
*         TO MLD. PSR CMLA751.
* 
* 
* MALET2R     JMO    86/04/14 
*         MODSET ADDS DECK MALET2R TO CML 3.2.
* 
* 
* MALETPR     JMO    86/04/14 
*         MODSET ADDS DECK MALETPR TO CML 3.2.
* 
* 
* P895D     JMO    86/11/25 
*         MODSET ADDS DECK P895D TO CML 3.2.
* 
* 
* MALET     JMO    86/08/15 
*         MODSET ADDS CIO SUPPORT TO MALET. 
*         PSR CMLA752.
* 
* 
* MALET10     JMO    86/08/15 
*         MODSET ADDS CIO SUPPORT TO MALET. 
*         PSR CMLA752.
* 
* 
* MALET11     JMO    86/08/15 
*         MODSET ADDS CIO SUPPORT TO MALET. 
*         PSR CMLA752.
* 
* 
* ISD1    JMO    86/02/14 
*         MODSET ADDS CIO CAPABILITY TO ISD1 PRODUCT OVERLAY. 
*         PSR CMLA752.
* 
* 
* SBP     JMO    86/02/14 
*         MODSET ADDS CIO PP SUPPORT TO SBP.
*         PSR CMLA752.
* 
* 
* DTI     JMS    86/04/23 
*         MODSET ADDS DMA SUPPORT TO DTI FOR 895. 
*         PSR CMLA752.
* 
* 
*         PSR CML0781 
* HPA22   REF 86/11/14
*         MODSET CML0781 CORRECTS THE 885/DEMA DETAILED STATUS ANALYSIS 
*         (DSA) INTERPRETATION OF THE VALID STATUS BIT (DETAILED STATUS 
*         WORD 9, BIT 5).  THIS PROBLEM RESULTED IN THE DSA MESSAGE 
*         "SC345-R/W-STATUS NOT VALID", AND A FAILURE TO DIAGNOSE THE 
*         ERROR CONDITION ACCURATELY FROM THE DETAILED STATUS.  THE CORR- 
*         ECTION INVOLVES CLEARING THE VALID STATUS BIT; THUS, THE BIT
*         WILL NOT BE SET IN THE HPA DETAIL REPORT, AND ITS USE SHOULD
*         BE IGNORED. 
* 
* 
*         PSR CMLA755 
* HPA32   REF 86/11/21
*         MODSET CMLA754 PROVIDES NORM SUPPORT FOR ADDITIONAL I4 PP/CPP 
*         DUAL STATE ASSIGNMENT (TO NOS/VE) AND RETURN (TO NOS) ERROR 
*         MESSAGES, INCLUDING A CPP DEADSTART ERROR MESSAGE.
* 
* 
* FSD     JMO    86/12/04 
*         MODSET CORRECTS FSD11 NOT TO GET I/O TIMEOUT ON CH RESERVE ERRORS 
*         IF THE DEADMAN TIMER IS LONGER THAN 9 SECONDS. PSR CMLA759. 
* 
* 
* MLD     JMO    86/12/08 
*         MODSET CORRECTS MLD NOT TO GET OVERFLOW ERROR ON NOSBE. 
*         PSR CMLA761.
* 
* 
* HISTORY LJC   86/12/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L195*. 
* 
* 
* 
* 
*         PSR CMLA758 
* HPA32   REF 86/11/26
* HPA34   MODSET CMLA758 PROVIDES HPA SUPPORT FOR ERROR CENTRALIZATION
*         AND SUPPORT FOR THE 895 SINGLE CIO PP DRIVER, 1XY.
* 
* 
* CMLA764 JMS    86/12/01 
*         1. MODSET ALLOWS T7X60A TO RUN WITH DC 53 AND 800 BPI.
* 
*         2. MODSET ADDS CORRECTIVE CODE TO T7X83B AND T7X85B 
*            TO CORRECT ERASURE LENGTHS AND ENSURE THAT A TAPE
*            BAD SPOT IS ERASED.
* 
* 
*         PSR CMLA765 
* HPA35   REF 86/12/19
*         MODSET CMLA765 CORRECTS A PRINT FORMAT FOR THE HPA 2550 
*         LINE/TRUNK STATISTICS REPORT, TO ALLOW THE REPORTING OF 
*         LARGER VALUES FOR TRANSMITTED/RECEIVED CHARACTER COUNTS.
* 
* 
* SKEDULR     JMO    86/12/16 
*         MODSET CORRECTS SKEDULR NOT TO GET 'LFN NOT FOUND' ON NOSBE.
*         PSR CMLA766.
* 
* 
* HISTORY LJC   87/01/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L671*. 
* 
* 
* 
* 
* ISW     JMO    87/01/06 
*         MODSET CORRECTS ISW19 TO MASK FOR 12 BITS OF RECORD COUNT.
*         PSR CMLA769.
* 
* 
*         PSR CMLA772 
* COMHPA  REF 87/01/06
*  -ERT   MODSET CMLA772 PROVIDES HPA SUPPORT FOR TAPE ERROR RECOVERY 
*         ENHANCEMENT.
* 
* 
* PDP     JMO    86/11/20 
*         MODSET CORRECTS PDP07 TO END THE MODULE RATHER THAN EXIT. 
*         PSR CMLA756.
* 
* 
*         PSR CMLA781 
* HPA3    REF 87/01/21
* HPA34   MODSET CMLA781 PROVIDES HPA SUPPORT FOR HYDRA FAILING ADDRESS.
* 
* 
*         PSR CMLA779 
* HPA32   REF 87/01/16
* HPA310  MODSET CMLA779 PROVIDES HPA SUPPORT FOR DFT RETRY 
* HPA311  ENHANCEMENTS, CONSISTING OF NEW ERROR CONDITIONS
* HPA313  AND ADDITIONAL DATA FROM THE 6TH DFT BUFFER.
* 
* 
* ISW     DHW    87/01/14 
*         THIS MODSET CORRECTS MISC. DOCUMENTATION ERRORS.
* 
* 
* ATC     JMO    87/01/09 
*         MODSET CORRECTS ATC TO NOT RUN ATC28 IF P9 NONZERO. 
*         PSR MSL0610.
* 
* 
* P895D     JMO    87/01/15 
*         MODSET CORRECTS THE DCN IN THE ERR ROUTINE. 
*         PSR CMLA774.
* 
* 
* DFU     JMO    87/01/20 
*         MODSET ADDS MODULE DFU03 FORMAT CYLINDER 885D ONLY. 
*         PSR CML0841.
* 
* 
* MLDVE  HWW   87/01/22.
* 
*         THIS MODSET ADDS S0 SUPPORT TO MLDVE. 
* 
* 
* ICI  HWW   87/01/20.
* 
*         THIS MODSET ADDS S0 SUPPORT TO THE ICI PRODUCT OVERLAY
* 
* 
* D639  HWW   87/01/20. 
* 
*         THIS MODSET ADDS S0 SUPPORT TO THE D639 PRODUCT OVERLAY 
* 
* 
* IFSD    JMS   86/01/27
* 
*         THIS MODSET ADDS COMDECK IFSD TO THE CML LIBRARY. 
*         COMDECK IFSD IS A MALET PRODUCT OVERLAY SUPPORTING
*         THE CM3 DISK SUBSYSTEM. 
* 
* 
* IDT     JMS    87/01/28 
*         MODSET ADDS DECK IDT TO CML 3.2.
* 
* 
* IFSD  HWW   87/01/28. 
* 
*         FIXES ADDRESSING PROBLEM CREATED WHEN MLD PASSES CONTROL
*         MODULE NUMBER AS AN EQUIPMENT RATHER THAN AS PART OF THE
*         UNIT NUMBER.
* 
* 
* ISW     JMO    87/01/29 
*         MODSET CORRECTS ISW MODULES 33, 34, 97A, 97B, 97C MODULE CARDS
*         FOR ICI RATHER THAN 6000. PSR CMLA792.
* 
* 
* CLM     JMO    87/02/04 
*         MODSET CORRECTS CLM30 TO NOT ERROR ON STATUS COMMAND IF CIO 
*         CHANNEL AND 895. PSR CMLA800. 
* 
* 
* CCM     JMO    87/02/04 
*         MODSET CORRECTS CCM30 TO NOT ERROR ON STATUS COMMAND IF CIO 
*         CHANNEL AND 895. PSR CMLA800. 
* 
* 
* ITW     DHW    87/01/14 
*         THIS MODSET CORRECTS MISC. DOCUMENTATION ERRORS.
* 
* 
*         PSR CMLA793 
* HPA32   REF 87/01/29
* HPA34   MODSET CMLA793 PROVIDES HPA SUPPORT FOR A CHANGE IN MPI ERROR 
*         CODES, BRINGING THEM IN CONFORMANCE WITH THE ISI SPECIFICA- 
*         TION.  SPECIFICALLY, MI68 CODE IS CHANGED TO SI68 (TRANSFER 
*         COUNT ERROR.) 
* 
* 
* MALET20     JMO    86/12/19 
*         MODSET ADDS SUPPORT TO MALET20 FOR D895.
*         PSR CMLA768.
* 
* 
* MLD      RDS    86/01/86
*          MODSET CMLA768B ADDS SUPPORT FOR D895 PRODUCT OVERLAY TO 
*          DECK MLD FOR MALET. PSR CMLA768. 
* 
* 
* CMLINST     JMO    86/01/15 
*         MODSET ADDS TEST DM8 FOR 895 TO CMLINST.
*         PSR CMLA768.
* 
* 
* DM8     JMO    86/01/27 
*         MODSET ADDS DECK DM8 TO CML 3.2.
* 
* 
* D895    RDS    86/01/27 
*         MODSET ADDS COMDECK D895 TO CML 3.2.
* 
* 
* MALET2Q     RDS    86/01/27 
*         MODSET ADDS DECK MALET2Q TO CML 3.2.
* 
* 
* MALETPQ     RDS    86/01/27 
*         MODSET ADDS DECK MALETPQ TO CML 3.2.
* 
* 
*         PSR CMLA789 
* HPA     REF 87/01/28
* HPA3    MODSET CMLA789 PROVIDES HPA SUPPORT FOR THE DUAL I4 ELEMENT 
* HPA312  NUMBER.  ELEMENT NUMBER 2 = IOU 0; ELEMENT NUMBER 12 HEXA-
*         DECIMAL = IOU 1.
* 
* 
* LOW     JMO    86/12/19 
*         MODSET CORRECTS LOW FOR DMA CHANNEL.
*         PSR CMLA791.
* 
* 
*         PSR CMLA806 
* HPA34   REF 87/02/10
*         MODSET CMLA806 CORRECTS A TYPE IN 895 UNRELEASED CODE.
* 
* 
* HISTORY LJC   87/02/10
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L673*. 
* 
* 
* 
* 
* CMLINST     JMO    87/02/13 
*         MODSET CORRECTS CMLINST FOR TABLE OVERFLOW WHEN GTR IS USED TO
*         SAVE MODULES FROM DIAGLIB. PSR CMLA809. 
* 
* 
*         PSR CMLA816 
* HPA39   REF 87/02/20
*         MODSET CMLA816 PROVIDES HPA SUPPORT FOR THE LCN CRAY NAD. 
* 
* 
* MLDVE  HWW   87/03/03.
* 
*         THIS MODSET UPDATES MLDVE FOR I4 IOU SUPPORT. 
* 
* 
* ISD  HWW   87/01/29.
* 
*         THIS MODSET UPDATES ISD FOR MALET/VE I4 SUPPORT 
* 
* 
* ISD1  HWW   87/02/03. 
* 
*         THIS MODSET UPDATES ISD1 FOR MALET/VE SUPPORT OF I4 
* 
* 
* IFSD  HWW   87/02/12. 
* 
*         THIS MODSET UPDATES IFSD TO SUPPORT I4 IOU
* 
* 
* D895  HWW   87/02/26. 
* 
*         THIS MODSET UPDATES D895 FOR MALET/VE SUPPORT ON I4 
* 
* 
* P895D  HWW   87/03/03.
* 
*         THIS MODSET UPDATES P895D TO SUPPORT MALET/VE ON I4 
* 
* 
* CMSI       RVS   87/02/23 
*          CORRECT TYPOS IN CMSI000.
* 
* 
* CMSI      RVS    87/02/24 
*          CORRECT TEST VS MACHINE TABLE IN CMSI220 
* 
* 
* CMSI       RVS    87/02/27
*            ALLOW DM8 TO RUN AT AL=3.
*            AND UPDATE SEVERAL MALET HELP DISPLAYS 
*            IN CMSI. 
* 
* 
* CMSI     RVS     87/02/20 
*        CORRECT NPA REPORT PROCEDURES FOR NOS 2.5.1+.
*        - CHECK FOR NPAULIB PROC LIBRARY.
*        - TIGHTEN CODE TO GENERATE THE CALL TO NPA-CRECAR. 
* 
* 
* P895D  HWW   87/03/04.
* 
*         THIS MODSET SHORTENS INITIALIZATION ERROR MESSGES AND 
*         MODIFIES THE WAY THE UPPER BOUNDS OF MEMORY IS DEFINED
*         WHEN ASSEMBLING FOR MALET/VE
* 
* 
* T7X     JMO    87/03/06 
*         MODSET CORRECTS T7X DOCUMENTATION TO NOT CAUSE COMPILER ERRORS
*         WHEN COMPILING FOR MALETVE. PSR CMLA828.
* 
* 
* HISTORY LJC   87/03/10
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L675*. 
* 
* 
* 
* 
* DTI     JMO    87/03/05 
*         MODSET CORRECTS DTI MODULES 13 AND 15 TO POST THE MESSAGE MODULE
*         NOT EXECUTED ON NIO CHANNEL. PSR CMLA824. 
* 
* 
* CDNDT   DHW    87/02/27 
*         THIS MODSET REMOVES DOCUMENTATION ABOUT PARAM-
*         ETER P7, AS IT IS NOT USED BY NDT.
*         PSR MSLA700 
* 
* 
* FMD     JMO    87/03/09 
*         MODSET CORRECTS FMD/FLD TO NOT CAUSE ANOTHER MODULE TO BE 
*         CREATED FOR THE '/' LINE. PSR CMLA829.
* 
* 
*         PSR CMLA813 
* HPA2    REF 87/03/05
* HPA22   MODSET CMLA813 PROVIDES HPA SUPPORT FOR MASSTOR MICROCODE 
* HPA3    LEVEL ROF.  THREE NEW ROF FORMATS/ERROR TYPES ARE SUPPORTED,
* HPA32   ALONG WITH SUPPORT FOR AN OLDER FORMAT, FX. 
* HPA37 
* HPA313
* 
* 
* CMSI   RVS    87/03/09
*         ADD DL8 , DTC , FLD TO THE LIST OF DISK TESTS 
*         VALID TO BE RUN IN CONFIDENCE MODE ( AL=03 ). 
* 
* 
* CMSI     RVS    87/03/09
*         ADD SUPPORT OF MAP IV AND HYDRA TO THE HPA
*         INTERFACE -CMSIHP1-.
* 
* 
*  CMSI    RVS 87/03/16 
*           ALLOW DTI TO BE RUN AT ACCESS LEVEL 03. 
* 
* 
* CMSI     RVS   87/03/17 
*          MODIFY THE EST LIST PROGRAM TO CORRECTLY DISPLAY 
*          THE CONCURRENT CHANNELS AVAILABLE ON THE I4 AND TO 
*          DISPLAY THE EQUIPMENT STATUS FROM THE NEW STATUS FLAG
*          IN THE UPPER BYTE OF THE EST.....
* 
*          THIS PROGRAM NOW MUST REACT TO 2 DIFFERENT LEVELS OF 
*          NOS OPERATING SYSTEM.....  IT HAS THERE FOR BEEN MOVED 
*          TO A DATA RECORD WITHIN CMSI501 AND THE PROCEDURE PARAMETER
*          -SYSVER- HAS BEEN ADDED TO THAT PROCEDURE. 
*          CCL OPTIONAL CODE WILL NOW BE INCLUDED IN CMSI116 BASED ON THE 
*          VALUE ENTERED FOR -SYSVER- DURING INITIALIZATION ON THE
*          CMLINST/CMSI PROCEDURES........... 
* 
* 
*         PSR CML0858 
* HPA310  REF 87/03/18
*         MODSET CML0858 CORRECTS THE VALIDITY CHECK FOR 835 CPU REGISTERS
*         92 (CCEL) AND 93 (MCEL).
* 
* 
* ISW     DHW    87/04/03 
*         MODSET CORRECTS MISC. DOCUMENTATION ERRORS
* 
* 
* MLDVE  HWW   87/03/16.
* 
*         THIS MOD FIXES GO/STOP PROBLEM IN MLD WHICH WAS OCCURING
*         WHEN THE STOP FLAG WAS BEING SENSED IN -RELEASE- ROUTINE. 
* 
* 
*         PSR CMLA721 
* HPA8    REF 87/03/24
*         MODSET CMLA721 ENABLE MTPLOT SUPPORT FOR ISMT(639), CMTS(698) 
*         AND FSC TAPE DRIVES.
* 
* 
* DM8     JMO    87/04/08 
*         MODSET CORRECTS DOCUMENTATION FOR ROUTINES THAT WILL ERROR
*         WHEN RUN FROM DM807. PSR CMLA836. 
* 
* 
* HISTORY LJC   87/04/13
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L677*. 
* 
* 
* 
* 
* DMA      DAK   03/31/87 
*          CODE WAS ADDED TO MODULES THAT WRITE CM TO 
*          VERIFY THAT THE USER HAS ENTERED THE UEM BASE
*          ADDRESS IN PARAMETER P7. 
* 
* 
* MLDVE  HWW   87/04/22.
* 
*         THIS MODSET ADDS IPI LOW LEVEL PRODUCT OVERLAY SUPPORT
*         TO MLDVE. 
* 
* 
* IPIDSK  HWW    87/04/22 
*         MODSET ADDS DECK IPI TO CML 3.2.
* 
* 
*         PSR CML0863 
* DSPLOT  REF 87/04/22
*         MODSET CML0863 CLEARS THE FTN FATAL ERROR 52 IN DSPLOT. 
* 
* 
* IDT     DHW    87/03/17 
*         THIS MODSET CORRECTS MISC. DOCUMENTATION ERRORS 
*         AND CHANGES THE MAXIMUM CM3/FSDII SECTOR TO 13B.
* 
* 
* IDT  HWW   87/04/22.
* 
*         THIS MODSET ADDS XMD3 SUPPORT TO THE IDT DIAGNOSTIC. IN 
*         ADDITION THE PASS COUNT FOR ALL SECTIONS WAS REDUCED FROM 
*         FOUR TO ONE. CORRECTIONS WERE MADE TO MISCELLANEOUS ERRORS. 
* 
* 
* IFSD  HWW   87/03/30. 
* 
*         THIS MODSET ADDS XMD3 SUPPORT TO IFSD PRODUCT OVERLAY.
* 
* 
*         PSR CMLA832 
* HPA312  REF 87/04/16
*         MODSET CMLA832 PROVIDES A SNAPSHOT OF FAULT STATUS 1 AND 2
*         REGISTERS AND CORRECTS THE PP NUMBER IN THE I1/I1CR/I2 HPA
*         DETAIL REPORTS. 
* 
* 
* CMSI     RVS   86/09/30 
*       TRAP ' CMLINST NOT IN LIBRARY FORMAT' ERROR 
*       IN CMSI INITIALIZATION PROC.
* 
* 
* CMSI   RVS   87/04/17 
* CMSI240     MODSET CML0822 ADDS THE OPTION TO CHANGE THE REGEN
* CMSI246     MASTER DATA BASE TAPE VSN TO MATCH THE SITE TAPE
* CMSI501     LIBRARY.
* GETRVSN     MODSET ADDS PROCEDURE GETRVSN TO CMSI501 AND AS 
*             STANDALONE PROCEDURE. 
* 
* 
*  CMSI   RVS   87/04/17
*  CMSIHP2     CORRECT HP2 BATCH JOB SUBMITTED BY CMSIHP2 TO
*              NOT ABORT IF OUTFILE IS TOO LARGE FOR AN 
*              INDIRECT ACCESS PERM. FILE.... 
*              USE SAVEIT FRO CMLINST LIBRARY.
* 
* 
*  CMSI    RVS   87/04/15 
*  CMSI232      MST PROCEDURE REPORTS ERROR MESSAGES YET
*               CORRECTLY RUNS TO COMPLETION. 
*               .PROBLEM CAUSED BY INCORRECT IF STATEMENTS IN 
*               . PROCEDURE CMSI232........ 
* 
* 
*         PSR CMLA281 
* MTPLOT  REF 87/05/04
*         MODSET CMLA281 ENHANCES MTPLOT TO SUPPORT EST ORDINALS 000
*         THROUGH 777B - A MAXIMUM OF 512 DECIMAL ENTRIES.
* 
* 
* HISTORY LJC   87/05/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L679*. 
* 
* 
* 
* 
*         PSR CML0786 
* DSPLOT  REF 87/04/22
*         MODSET CML0786 ENABLES DSPLOT SUPPORT FOR ISD, DEMA, FSC, 
*         819, 895 AND 887 DISK DEVICES.  PREVIOUSLY, DSPLOT RECOG- 
*         NIZED ONLY 884 AND 885 (SEF RECORD TYPE 44B) DEVICES. 
* 
* 
* T7X     JMO    87/05/14 
*         MODSET CORRECTS ERRORS IN T7X MESSAGES IN MODULES 83 AND 83B. 
*         PSR CMLA839.
* 
* 
* CMLINST     JMO    87/05/14 
*         MODSET CORRECTS CMLINST DOCUMENTATION FOR 698 TAPES.
*         PSR CMLA840.
* 
* 
* HISTORY LJC   87/06/02
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L681*. 
* 
* 
* 
* 
*  CMSI   RVS  87/06/08 
*  CMS2122       ALLOW THE OPTIONAL USE OF THE DEVICE 
*  CMS2123       CODE IN THE CMSI ROUTINES........... 
*  CMS2125
*  MLTDEMA , MLTTAP1 , MLTTAP2 , MLTTFF 
* 
* 
* CMSI    RVS   87/06/10
* CMS2122      THIS MODSET PROVIDES CIO DMA CHANNEL SUPPORT 
* CMS2123      FOR THE CMSI / MALET PROCEDURES.... IT ALLOW 
* CMS2125      FOR EXECUTION OF A PROCEDURE GENERATED ASSIGN
* CMS2127      DIRECTIVE TO CONTAIN THE 'CCH' PARAMETER.
*  (OTHERS) 
* 
* 
* CMSI     RVS     87/06/04 
* CMSIHP1       THIS MODSET CORRECTS INCONSISTENTIES IN THE 
* CMSIHP2       HPA REPORT GENERATION.  IT ALSO ADDS THE FMT
*               PARAMETER TO CONTROL THE USE OF THE "R" ON THE
*               HPA STATEMENT.   IT ALSO CHANGES THE MEANING OF 
*               THE OUT PARAMETER TO HRDCPY.
* 
* 
* T7X     JMO    87/06/03 
*         MODSET CORRECTS T7X85 TO TEST FOR EOT INSTEAD OF FM.
*         PSR CMLA842.
* 
* 
*         PSR CMLA847 
* HPA311  REF 87/06/09
*         MODSET CMLA847 REMOVES CODE TO SUPPRESS A FALSE HW ERROR. 
*         THE HPA WORKAROUND (UNDER MODSET CMLA669) IS NO LONGER NEEDED,
*         DUE TO A HW CORRECTION. (MODSET CMLA669 ADDED HPA FL AND CPU
*         TIME OVERHEAD.) 
* 
* 
* MLDVE  HWW   87/06/12.
* 
*         THIS MOD UPDATES THE LEVEL/VERSION IN MLDVE FOR THE 1.2.3 MALET 
*         RELEASE.
* 
* 
*         PSR CML0870 
* HPA22   REF 87/05/04
* HPA34   MODSET CML0870 ENHANCES 895 FORMAT 6 STATISTICAL REPORTING. 
* 
* 
*         PSR CMLA849 
* HPA38   REF 87/06/09
* HPA310  MODSET CMLA849 PROVIDES A DEFAULT SNAPSHOT OF FAULT STATUS
* HPA311  REGISTERS IN THE HPA DETAIL REPORTS FOR ALL CPU AND THE IOU4. 
* HPA312
* HPA313
* HPA314
* 
* 
* MSD     DHW   06/28/87
*         THIS MODSET ADDS THE MSD DIAGNOSTIC TO THE CML. MSD 
*         IS THE SIDE DOOR PORT PORTION OF  THE STORNET/ESMII 
*         MALET DIAGNOSTIC.THE LOW SPEED PORT PORTION IS MSM. 
* 
* 
* MALET10     JMO    86/12/04 
*         MODSET ADDS SUPPORT TO MALET10 FOR MESM.
*         PSR CMLA853.
* 
* 
* MALET11     JMO    86/12/04 
*         MODSET ADDS SUPPORT TO MALET11 FOR MESM.
*         PSR CMLA853.
* 
* 
* MALET20     JMO    86/12/04 
*         MODSET ADDS SUPPORT TO MALET20 FOR MESM.
*         PSR CMLA853.
* 
* 
* MLD     JMO    86/02/14 
*         MODSET ADDS SUPPORT OF DESM PRODUCT OVERLAY.
*         PSR CMLA853.
* 
* 
* CMLINST     JMO    87/06/30 
*         MODSET ADDS SUPPORT FOR STORNET TESTS MSD AND MSM.
*         PSR CMLA853.
* 
* 
* CDCMLI1     JMO    87/06/30 
*         MODSET ADDS SUPPORT FOR STORNET TESTS MSD AND MSM.
*         PSR CMLA853.
* 
* 
* CDCMLI2     JMO    87/06/30 
*         MODSET ADDS SUPPORT FOR STORNET TESTS MSD AND MSM.
*         PSR CMLA853.
* 
* 
* MSM     JMO    87/06/29 
*         MODSET ADDS DECK MSM TO CML 3.2.
* 
* 
* MALET2S     JMO    86/12/02 
*         MODSET ADDS DECK MALET2S TO CML 3.2.
* 
* 
* MALETPS     JMO    86/12/02 
*         MODSET ADDS DECK MALETPS TO CML 3.2.
* 
* 
* DESM     JMO    86/12/05
*         MODSET ADDS DECK DESM TO CML 3.2. 
* 
* 
*         PSR CML0880 
* HPA22   REF 87/06/12
*         MODSET CML0880 CORRECTS THE OCTAL TO DECIMAL CONVERSION 
*         OF THE EST ORDINAL WHEN IS IS USED THE DEFAULT HUID.
* 
* 
*         PSR CMLA851 
* HPA310  REF 87/06/24
* HPA311  MODSET CMLA851 CHANGES LABELS IN THE MAINFRAME ERROR REPORTS. 
* HPA312  THE FIELDS NOW LABELED "FAULT CODE" WILL BE RELABELED "REG
* HPA313  BIT ID".  THE FIELDS CONTAINING THE DFT ANALYSIS CODE WILL BE 
* HPA314  LABELED "FSC" (FAULT SYMPTOM CODE). 
* 
* 
* CMSI    RVS   87/06/10
* CMS2122      THIS MODSET PROVIDES CIO DMA CHANNEL SUPPORT 
* CMS2123      FOR THE CMSI / MALET PROCEDURES.... IT ALLOW 
*            FOR EXECUTION OF A PROCEDURE GENERATED ASSIGN
*            DIRECTIVE TO CONTAIN THE 'CCH' PARAMETER.
*            CONTINUES THE FIX OF PSR CMLA827.
* 
* 
* CMSI     RVS  87/06/30
* CMSI501    PROVIDE NOS2.5.3 PARAMETER SUPPORT FOR 
*            SYSVER IN CMSI501 CHECK LIST.
* 
* 
*         PSR CMLA852 
* HPA38   REF 87/06/30
* HPA310  MODSET CMLA852 PROVIDES HPA SUPPORT FOR THE 815-S.
* HPA312
* 
* 
* MLD     JMO    87/07/06 
*         MODSET CORRECTS 
*         PSR CMLA856.
* 
* 
* CMLINST     JMO    87/07/08 
*         MODSET CORRECTS CMLINST FOR ERRORS IN STORNET.
*         PSR CMLA857.
* 
* 
* CMSI    RVS    87/07/02 
* CMSI000     ADD/REPLACE CML LEVEL MARKER IN THE TWO 
*             PROC HEADER STATEMENTS. 
* 
* 
* MSM     JMO    87/07/13 
*         MODSET CORRECTS MSM DOCUMENTATION ERRORS. 
*         PSR CMLA858.
* 
* 
* MSD     DHW    87/07/13 
*         THIS MODSET SHORTENS THE LINE LENGTH FOR THE 99A
*         MODULE, SO THEY ARE NOT TRUNCATED ON THE DISPLAY. 
*         PSR CMLA858.
* 
* 
* CMSI501   RVS 87/07/15
*           CORRECT TYPO IN PROCEDURE CMSI501 'SYSVER' CHKLST.
* 
* 
* SKEDULR     JMO    87/05/14 
*         MODSET CORRECTS SKEDULR TO DETECT ANOTHER COPY RUNNING. 
*         PSR CML0868.
* 
* 
*         PSR CML0881 
* HPA22   REF 87/07/15
*         MODSET CML0881 ENABLES A HUID MATCH FOR 885 UNITS.
* 
* 
*         PSR CML0882 
* HPA8    REF 87/07/12
*         MODSET CML0882 ALLOWS THE MERGING OF MULTI-MAINFRAME SEF DATA 
*         WITH THE SAME TIMESTAMP WHEN CREATING A NEWHF.  MODSET CHECKS 
*         THE MFID AND CH-EQ-UN FIELDS. 
* 
* 
*         PSR CML0883 
* HPA8    REF 87/07/14
*         MODSET CML0883 PROVIDES END CASE CORRECTIONS TO THE MERGING 
*         OF SEF AND OLDHF IN THE GENERATION OF A NEWHF.
* 
* 
*         PSR CML0889 
* HPA8    REF 87/07/15
*         MODSET CML0889 RESTORES THE EST FOR NOS/BE SYSTEM MESSAGES
*         IN THE HPA SUMMARY REPORTS. 
* 
* 
*         PSR CML0885 
* MTPLOT  REF 87/07/15
*         MODSET CML0885 PROVIDES A SUGGESTED FIX FOR MTPLOT
*         FTN FATAL ERROR 78 - ILLEGAL DATA IN FIELD. 
* 
* 
*         PSR CMLA867 
* DKDATA  REF 87/07/15
*         MODSET CMLA867 UPDATES THE DKDATA TEXT FOR DSPLOT.
* 
* 
* MY8     JMO    87/07/20 
*         MODSET CORRECTS MY802 TO NOT TIMEOUT UNDER MALET/VE.
*         PSR MAVA009.
* 
* 
* HISTORY LJC   87/07/21
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L683*. 
* 
* 
* 
* 
*         PSR CMLA868 
* HPA38   REF 87/07/24
* HPA310  MODSET CMLA868 PROVIDES HPA SUPPORT FOR THE 825-S.
* HPA312
* 
* 
*         PSR CMLA871 
* HPA8    REF 87/07/24
* HPA9    MODSET CMLA871 ENABLES CMTS, ISMT AND FSC BLOCKS READ/
*         WRITTEN COUNTS IN THE TAPE MEDIA REPORT.
* 
* 
*         PSR CML0877 
* HPA315  GFS 87/07/24
*         MODSET CML0877 SETS A THRESHOLD OF 10 PER HOUR FOR SINGLE SECDED
*         (SC=55) ERRORS TO PREVENT A LARGE LISTING.
* 
* 
* CLM     JMO    87/07/28 
*         MODSET CORRECTS CLM NOT TO TIMEOUT ON STATUS COMMAND. 
*         PSR CMLA872.
* 
* 
* MSM     JMO    87/07/15 
*         MODSET CORRECTS TIMES AND SPEEDS UP MSM FOR DEMOT.
*         PSR CMLA873.
* 
* 
* CMS2123    RVS   87/08/03 
*           CORRECT BAD MODSET CMLA827A.... 
* 
* 
* FMC     JMO    87/07/29 
*         MODSET CORRECTS FMC TO NOT GET COMPILER ERRORS WITH MALET/VE. 
*         PSR CMLA874.
* 
* 
* FHC     JMO    87/07/29 
*         MODSET CORRECTS FHC TO NOT GET COMPILER ERRORS WITH MALET/VE. 
*         PSR CMLA874.
* 
* 
* CLM     DHW    87/07/17 
*         THIS MODSET ALLOWS NDM TO TEST THE 64K MEMORY ON
*         A MODEL B  CCC. 
* 
* 
*         PSR CMLA863 
* HPA3    REF 87/08/06
* HPA37   MODSET CMLA863 MAKES SEVERAL CORRECTIONS TO HPA MASSTOR RPTS. 
*         FIRST OF ALL, IT PROVIDES A USAGE SUMMARY FOR AN SM GREATER 
*         THAN 0 AND A DRD GREATER THAN 1, BY ENABLING A SUMMARY FOR SMS
*         0 - 7 AND DRDS 0 - 15.  ALSO, THE MODSET ALLOWS CUMULATIVE
*         TO BE REPORTED IN ORDER OF OCCURRENCE, BY DISABLING A SORT ON 
*         SM/DRD.  FINALLY, X/Y CUMULATIVE STATUS COORDINATE POSITIONS
*         ARE RENAMED Y/Z, FOR AGREEMENT WITH MASSTOR DOCUMENTATION.
* 
* 
* CMLINST   RVS    87/08/07 
* CMS2123       THIS MODSET CORRECT ERRORS MADE IN MODSET CMLA875.
* 
* 
* MALET11     JMO    87/08/17 
*         MODSET CORRECTS MALET11 FOR ASSIGNING LCN DEVICE CODES. 
*         PSR CMLA877.
* 
* 
* HISTORY LJC   87/08/18
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L685*. 
* 
* 
* 
* 
* DESM     JMO    87/08/18
*         MODSET CORRECTS DESM TO NOT GET CHANNEL FAILED TO GO EMPTY
*         ON AN 830. PSR CMLA885. 
* 
* 
* MSM     JMO    87/08/19 
*         MODSET CORRECTS MSM TO NOT FAIL WITH I/O TIMEOUT ON AN 830. 
*         PSR CMLA885.
* 
* 
* MALET10     JMO    87/08/26 
*         MODSET CORRECTS MALET10 DISPLAY FOR DEVICE CODE OF 14.
*         PSR CMLA886.
* 
* 
* DESM     JMO    87/08/25
*         MODSET CORRECTS DESM TO NOT GET DMA ERROR STATUS SET ON CIO AND 
*         SIDE DOOR PORT. PSR CMLA888.
* 
* 
* MALET11     JMO    87/08/28 
*         MODSET CORRECTS MALET11 TO ADD THE CIO CHANNEL FLAG IN ASSIGN.
*         PSR CMLA890.
* 
* 
* HISTORY LJC   87/09/04
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L687*. 
* 
* 
* 
* 
*         PSR CMLA889 
* HPA36   REF 87/09/16
*         MODSET CMLA889 SUPPRESSES ASTERISKS IN THE HPA ESM SINGLE BIT 
*         ERRORS REPORT WHEN A BIT CANNOT BE IDENTIFIED FOR AN INVALID
*         SYNDROME CODE.
* 
* 
*         PSR CMLA892 
* HPA38   REF 87/08/28
* HPA313  MODSET CMLA892 PROVIDES 990 MEMORY(MODELS 40/41) ENHANCEMENTS.
* HPA314
* 
* 
*         PSR CMLA893 
* HPA32   REF 87/08/28
* HPA34   MODSET CMLA893 REFORMATS THE HPA REPORTING OF THE THREE 
*         895 CIO REGISTERS (OSR, ACR AND ESR) FROM OCTAL TO HEX. 
*         IT ALSO REPLACES THE REGISTER MNEMONIC WITH THE REGISTER
*         NAME. 
* 
* 
* MALET2O     JMO    87/09/16 
*         MODSET CORRECTS MALET2O BLANK LINE WHICH GIVES ASSEMBLY ERRORS. 
*         PSR CMLA895.
* 
* 
* MLDVE  HWW   87/09/21.
* 
*         THIS MODSET ADDS CODE TO MLDVE TO INCLUDE SUPPORT FOR THE 
*         STORNET HARDWARE. 
* 
* 
* DESM  HWW   87/09/24. 
* 
*         THIS MODSET MODIFIES THE DESM PRODUCT OVERLAY TO SUPPORT
*         EXECUTION UNDER MALET/VE. THIS MOD APPLIES TO NON-S0
*         MAINFRAMES. 
* 
* 
* MSD  HWW   87/09/17.
* 
*         MODIFICATIONS TO MSD TO ALLOW EXECUTION UNDER MALET/VE. 
* 
* 
* HISTORY LJC   87/10/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L689*. 
* 
* 
* 
* 
* IDT  HWW   87/10/12.
* 
*         FIXES PROBLEM WITH PACKET STATUS BEING OFF BY ONE WORD
*         WHEN DISPLAYED AS PART OF ERROR MESSAGE.
* 
* 
* D639  HWW   87/10/13. 
* 
*         MOD CORRECTS CODING ERROR IN DENSITY SELECTION ALGORITHM. 
* 
* 
*         PSR CMLA899 
* HPA312  REF 87/10/09
* HPA313  MODSET CMLA899 CORRECTS THE IDENTIFICATION OF 990 
* HPA314  SECDED MEMORY SIZE, PLUS SUPPLIES MINOR MF CORRECTIONS. 
* 
* 
*  CMSI330    RVS 87/09/11
*           CORRECT THE HELP MESSAGE FOR OWNCODE. 
* 
* 
* CMSI   RVS  87/09/18
* MLTTAP1     CORRECT THE OPERATOR COMMAND IMAGE IN TERMINAL
*             NOTE.  (SHOULD BE VSN,EQ,ESTXXX)
* 
* 
*  CMSI     RVS  87/09/17 
*  MLTTAP2       ADD HELP EXPLAINATION FOR TAPE DENSITY SELECTION.
* 
* 
* ISW     JMO    87/10/29 
*         MODSET CORRECTS ISW23 TO NOT GET WC OR BUFFER INDEX ERROR 
*         WHEN RUNNING IN GCR MODE. PSR CMLA904.
* 
* 
*         PSR CMLA903 
* HPA32   REF 87/10/28
* HPA34   MODSET CMLA903 CHANGES THE VALIDITY CHECK FOR 895 SENSE BYTE
*         STATUS.  IF 895 DI STATUS = XXX2B (AND NOT 2112B), STATUS IS
*         VALID.
* 
* 
*         PSR CMLA907 
* HPA37   REF 87/11/10
*         MODSET CMLA907 SUPPORTS ROF MASSTOR MICROCODE ADDITIONS.
* 
* 
* HISTORY LJC   87/11/18
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L691*. 
* 
* 
* 
* 
* MLD     JMO    87/11/17 
*         MODSET CORRECTS MLD *CALLS SO THE PRODUCT OVERLAY LISTINGS
*         ARE IN THE CORRECT ORDER. PSR CMLA910.
* 
* 
* DESM0   HWW    87/11/24 
*         MODSET ADDS DECK DESM0 CML 3.2. 
* 
* 
* MLDVE  HWW   87/11/17.
* 
*         ADDS CODE TO MLDVE TO SUPPORT THE STORNET EQUIPMENT 
*         ON A 930 CLASS MAINFRAME. 
* 
* 
* DESM  HWW   87/11/17. 
* 
*         ADDS CODE TO DESM TO SUPPORT MALET/VE ENHANCED ASSIGN 
*         PROCESSOR EXPANDED ACCESS LEVELS. 
* 
* 
* MSM     JMO    87/11/18 
*         MODSET CHANGES MSM TO SUPPORT AL 30 AND 32 FOR MALETVE ONLY.
*         PSR CMLA909.
* 
* 
* MSD     JMO    87/11/19 
*         MODSET CHANGES MSD TO SUPPORT AL 30 AND 32 FOR MALETVE ONLY.
*         PSR CMLA909.
* 
* 
* SSD     JMO    87/11/23 
*         MODSET ADDS DECK SSD TO CML 3.2.
* 
* 
* SSM     JMO    87/11/23 
*         MODSET ADDS DECK SSM TO CML 3.2.
* 
* 
*         PSR CMLA908 
* HPA38   REF 87/10/28
* HPA310  MODSET CMLA908 SUPPORTS DFT PARTIAL WRITE PARITY ERRORS 
* HPA311  (DFT CODE 106 - FOR ALL MF EXCEPT 99X) AND DFT PARTIAL
* HPA312  WRITE ADDRESS PARITY ERROR (DFT CODE 21E - FOR 99X ONLY). 
* HPA313
* HPA314
* 
* 
*         PSR CMLA913 
* HPA34   REF 87/11/30
*         MODSET CMLA913 CORRECTS THE HPA 865/875 ANALYSIS REPORT HEADER. 
*         IT PREVENTS AN OCTAL ZERO (55B) FROM BEING REPORTED AS A HEX
*         ZERO (6D) AND REMOVES THE ELEMENT/MODEL HEADERS WHICH ARE NOT 
*         RELEVANT TO 865/875S. 
* 
* 
* HISTORY LJC   87/12/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L693*. 
* 
* 
* 
* 
* MALET2L     JMO    87/09/08 
*         MODSET ADDS DECK MALET2L TO CML 3.2.
* 
* 
* MALETPL     JMO    87/09/08 
*         MODSET ADDS DECK MALETPL TO CML 3.2.
* 
* 
* LCN2    DHW    87/12/08 
*         MODSET ADDS DECK LCN2 TO CML 3.2. THIS
*         PROD OVLY PREVENTS FALSE DIAGNOSTIC 
*         ERRORS DUE TO TRUNK INTERFERENCE. 
*         PSR CMLA544.
* 
* 
* NLM     DHW    87/12/08 
*         THIS MODSET ADDS USE OF NEW PO (LCN2). THIS 
*         PROD OVLY PREVENTS FALSE ERRORS DUE TO IN-
*         TERFERENCE ON OTHER TRUNKS. 
*         PSR CMLA544.
* 
* 
* MLD     JMO    87/12/08 
*         MODSET ADDS THE CALL TO LCN2 IN MLD.
*         PSR CMLA544 
* 
* 
* MALET10     JMO    87/09/17 
*         MODSET ADDS SUPPORT TO MALET10 FOR LCN2 PRODUCT OVERLAY.
*         PSR CMLA544.
* 
* 
* MALET20     JMO    87/09/17 
*         MODSET ADDS SUPPORT TO MALET20 FOR LCN2 LANGUAGE. 
*         PSR CMLA544.
* 
* 
* LOW     JMO    87/11/17 
*         MODSET ADDS CHECKS FOR CHANNEL PARITY ERRORS ON INPUT.
*         PSR CMLA914.
* 
* 
* 67X     JMO    87/11/18 
*         MODSET ADDS CHECKS FOR CHANNEL PARITY ERRORS ON INPUT.
*         PSR CMLA914.
* 
* 
* 844FT   JMO    87/11/17 
*         MODSET ADDS CHECKS FOR CHANNEL PARITY ERRORS ON INPUT.
*         PSR CMLA914.
* 
* 
* FMDFT   JMO    87/11/17 
*         MODSET ADDS CHECKS FOR CHANNEL PARITY ERRORS ON INPUT.
*         PSR CMLA914.
* 
* 
* LCN1    JMO    87/11/17 
*         MODSET ADDS CHECKS FOR CHANNEL PARITY ERRORS ON INPUT.
*         PSR CMLA914.
* 
* 
* ISD     JMO    87/11/17 
*         MODSET ADDS CHECKS FOR CHANNEL PARITY ERRORS ON INPUT.
*         PSR CMLA914.
* 
* 
* LSFMD1  JMO    87/11/17 
*         MODSET ADDS CHECKS FOR CHANNEL PARITY ERRORS ON INPUT.
*         PSR CMLA914.
* 
* 
* LSFMD2  JMO    87/11/17 
*         MODSET ADDS CHECKS FOR CHANNEL PARITY ERRORS ON INPUT.
*         PSR CMLA914.
* 
* 
* FMU     JMO    87/12/14 
*         MODSET ADDS DEFINES FOR SO MALETVE COMPILER DOES NOT ERROR. 
*         PSR CMLA915.
* 
* 
* DESM  HWW   87/12/21. 
* 
*         CODE WAS ADDED TO DESM TO INSURE THAT DMA READS AND 
*         WRITES COULD NOT BE EXECUTED IF THE DMA BUFFER HAS
*         NOT BEEN ESTABLISHED BY THE EXECUTIVE IN CM.
* 
* 
* DESM0  HWW   87/12/21.
* 
*         CODE WAS ADDED TO DESM0 TO INSURE THAT DMA READS AND
*         WRITES COULD NOT BE EXECUTED IF THE DMA BUFFER HAS
*         NOT BEEN ESTABLISHED BY THE EXECUTIVE IN CM.
* 
* 
* MLDVE  HWW   87/12/23.
* 
*         THIS MODSET UPDATES THE MLDVE VERSION TO 1.4 AND LEVEL TO 
*         700 FOR THE 1.3.1 NOS/VE RELEASE. 
* 
* 
* CMLINST     JMO    88/01/04 
*         MODSET ADDS SYSVER OF NOS26 TO CMLINST. 
*         PSR CMLA916.
* 
* 
* CMLINST     JMO    88/01/06 
*         MODSET CORRECTS NOSBE PROC CML3 TO NOT OVERFLOW ASSEMBLING MLD. 
*         PSR CMLA919.
* 
* 
* HISTORY LJC   88/01/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L695*. 
* 
* 
* 
* 
* 844FT     JMO    88/01/07 
*         MODSET CORRECTS 844FT TO NOT GET FALSE CH PE ON 170 SYSTEM. 
*         PSR CMLA921.
* 
* 
* NLM     JMO    88/01/12 
*         MODSET CORRECTS NLM99 FOR ADDITION OF NEW ERROR PROCESSORS. 
*         PSR CMLA924.
* 
* 
*         PSR CMLA929 
* HPA3    REF 88/01/13
* HPA38   MODSET CMLA929 SUPPORTS DFT REVISION 4. 
* HPA310
* HPA311
* HPA312
* HPA313
* HPA314
* 
* 
* MLDVE  HWW   88/01/22.
* 
*         THIS MODSET INSURES THAT AN INTERMEDIATE VALUE IS STORED
*         IN THE CHANNEL INTERLOCK TABLE WHILE MLDVE IS ACCESSING 
*         THE TABLE. THIS MOD DUPLICATES A CHANGE MADE TO THE NOSVE 
*         DRIVERS AND INSURES COMPATABILITY WITH THEIR USAGE OF THE 
*         CHANNEL INTERLOCK TABLE.
* 
* 
*         PSR CMLA931 
* HPA2    REF 88/01/20
* HPA3    MODSET CMLA931 SUPPORTS STORNET.
* HPA36 
* 
* 
*  CMSI121    RVS  88/01/19 
*           CORRECT NPA TERMINAL LISTING DISPLAY. 
* 
* 
*   CMSI501    RVS   88/01/11 
*           ADD SUPPORT FOR NOS 2.6.1 SYSTEM RELEASE. 
*           ALLOW SUPPORT OF A DEFAULT (CR) TO BE LATEST SYSTEM.
* 
* 
* T7X     JMO    88/01/25 
*         MODSET CORRECTS T7X MODULE 80B MESSAGE. 
*         PSR CMLA932.
* 
* 
* MALET11     JMO    88/01/26 
*         MODSET CORRECTS MALET11 TO GET THE ESM/STORNET ADDRESS FROM 
*         THE CORRECT WORD IF DC=171 OR 211. PSR CMLA934. 
* 
* 
* DESM     JMO    88/01/27
*         MODSET CORRECTS DESM PRODUCT OVERLAY TO GET THE ESM 
*         ADDRESS FROM THE CORRECT PLACE. PSR CMLA934.
* 
* 
* CMLINST     JMO    88/02/01 
*         MODSET CORRECTS CMLUTIL DS TAPE PROC LIBEDIT DIRECTIVE OF 
*         DELETE ABS/HPA-ULIB/HPALIB TO DELETE ABS/HPA AND DELETE 
*         ULIB/HPALIB. PSR CMLA935. 
* 
* 
* HISTORY LJC   88/02/03
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L697*. 
* 
* 
* 
* 
* CMSI     RVS   88/02/04 
* CMSI114         FIX PROBLEM OF USING DIRECT ACCESS FILES. 
*                 REPLACE TEST FOR LOCAL FILE WITH ASSIGNED FILE. 
* 
* 
*         PSR CMLA937 
* HPA     REF 88/01/20
* HPA3   MODSET CMLA937 SUPPORTS THE 96X (PIP3).
* HPA38 
* HPA310
* HPA311
* HPA312
* HPA313
* 
* 
*         PSR CMLA940 
* HP32    REF 88/02/09
*         MODSET CMLA940 SUPPORTS NOS DEADSTART AND NORMAL TERMINATION
*         MESSAGES FROM THE BML FILE. 
* 
* 
* MLDVE  HWW   88/02/15.
* 
*         THIS MODSET FIXES PROBLEM WITH CRDL HANGS ON 60NS S0. 
*         ALL CRDL INSTRUCTIONS WHICH COULD BE LOOPED ON ARE
*         REPLACED BY CRML INSTRUCTIONS.
* 
* 
* MSM     JMO    88/01/28 
*         MODSET CORRECTS THE DISPLAY MESSAGE IN MSM19 AND 20 AT AL=3.
*         PSR CMLA934.
* 
* 
*         PSR CMLA942 
* HPA32   REF 88/02/19
* HPA38   MODSET CMLA942 PROVIDES DFT VERSION 4 CORRECTIVE CODE.
* HPA311
* HPA312
* HPA313
* HPA314
* 
* 
* ISW     JMO    88/02/16 
*         MODSET CHANGES ISW TO NOT SUPPORT 6BIT MODE AND CODE CONVERSION 
*         TABLES SO FALSE ERRORS DO NOT OCCUR. PSR CMLA944. 
* 
* 
*         PSR CMLA948 
* HPA311  REF 88/02/24
* HPA313  MODSET CMLA948 PROVIDES CHANGES TO INTERPRETATION OF THE
*         DFT REVISION 4 MODEL DEPENDENT BUFFER.
* 
* 
*         PSR CMLA953 
* HPA311  REF 88/02/24
* HPA313  MODSET CMLA953 PROVIDES MODEL DEPENDENT BUFFER CHANGES AND
*         CORRECTIONS TO THE EXCHANGE PACKAGE BUFFER. 
* 
* 
* PD0     JMO    88/01/04 
*         MODSET ADDS DECK PD0 TO CML 3.2.
* 
* 
*         PSR CML0911 
* DSPLOT  REF 88/03/18
*         MODSET CML0911 CORRECTS THE REPORTING OF 844 SYMPTOM CODES
*         BY DSPLOT.  (THE 885 TABLES WERE BEING INDEXED FOR 844 DSA
*         ERRORS.)
* 
* 
* ATC     JMO    88/03/22 
*         MODSET CORRECTS ATC28 TO NOT ERROR ON INPUT PE AFTER SETTING
*         EVEN CHANNEL PARITY FUNCTION. PSR MSLA841.
* 
* 
* ICI  HWW   88/03/24.
* 
*         THIS MODSET ADDS SUPPORT TO ICI FOR RUNNING THE PDP DIAGNOSTIC
*         ON THE CYBER 930. 
* 
* 
* HISTORY LJC   88/03/28
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L699*. 
* 
* 
* 
* 
* TIO     JMO    88/04/01 
*         MODSET CORRECTS TIO TO DISPLAY 7 DIGITS FOR RECORD COUNT
*         IN THE DAYFILE INSTEAD OF 6. PSR CML0916. 
* 
* 
*         PSR CML0915 
* MTPLOT  REF 88/03/31
*         MODSET CML0915 PROVIDES A SUGGESTED FIX FOT MTPLOT
*         FTN FATAL 78 - ILLEGAL DATA IN FIELD. 
* 
* 
* HISTORY LJC   88/04/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L701*. 
* 
* 
* 
* 
*         PSR CML0908 
* MTPLOT  REF 88/04/07
*         MODSET CML0908 PROVIDES A SUGGESTED FIX FOT MTPLOT
*         FTN FATAL 78 - ILLEGAL DATA IN FIELD, WHICH OCCURS
*         WHEN TAPE10 IS EMPTY. 
* 
* 
*         PSR CMLA955 
* HPA314  JOD 88/04/08
*         MODSET CMLA955 ADDS 994 SUPPORT 
* 
* 
* ITW     JMO    88/04/06 
*         MODSET CORRECTS ITW EC 224 AFTER RUNNING ITW11 ON 930.
*         PSR CMLA945.
* 
* 
* ITU     JMO    88/04/06 
*         MODSET CORRECTS ITU EC 224 AFTER RUNNING ITU11. 
*         PSR CMLA945.
* 
* 
* ITW     JMO    88/02/21 
*         MODSET ADDS ADAPTER MEMORY DUMP MODULE TO ITW.
*         PSR CMLA946.
* 
* 
* ITU     JMO    88/02/21 
*         MODSET ADDS ADAPTER MEMORY DUMP MODULE TO ITU.
*         PSR CMLA946.
* 
* 
* MSM     JMO    88/04/22 
*         MODSET ADDS PARAMETER P3 TO BYPASS THE PAUSE IN MSM40.
*         PSR CMLA956.
* 
* 
* SSM     JMO    88/04/22 
*         MODSET ADDS PARAMETER P3 TO BYPASS THE PAUSE IN SSM40.
*         PSR CMLA956.
* 
* 
*         PSR CMLA958 
* HPA     REF 88/04/28
* HPA22   MODSET CMLA958 PROVIDES DFT MODEL DEPENDENT BUFFER
* HPA38   CORRECTIONS FOR THE 96X/99X.  MODSET ALSO INCLUDES
* HPA311  EDITS FOR OTHER MF ERROR PROCESSING.
* HPA312
* HPA313
* 
* 
* HISTORY LJC   88/05/02
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L703*. 
* 
* 
* 
* 
*         PSR CMLA960 
* HPA32   REF 88/05/04
*         MODSET CMLA960 REPLACES "NORMAL OS TERMINATION" WITH
*         "SYSTEM CHECKPOINT" TEXT IN SYSTEM ACTIVITY REPORTING.
* 
* 
*         PSR CMLA962 
* HPA3    JOD 88/05/13
* HPA37   MODSET CMLA962 ADDS 7 MASSTOR ERROR CODES/MESSAGES
* 
* 
*         PSR CMLA963 
* HPA22   REF 88/05/18
*         MODSET CMLA963 CORRECTS AN END-CASE WORK-AROUND TO HANDLE 
*         BML DFT RECORDS LOGGED OUT OF SEQUENCE. 
* 
* 
* T7X     JMO    88/05/02 
*         MODSET CORRECTS T7X MODULE 970 TO DISPLAY THE CORRECT DS WORDS
*         17-20 ON AN ERROR. PSR CMLA959. 
* 
* 
* HISTORY LJC   88/06/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L705*. 
* 
* 
* 
* 
*         PSR CMLA964 
* HPA311  REF 88/06/20
          MODSET CMLA964 BLANKS AN UNUSED FIELD FOR PIP3 END CASE.
* 
* 
* MALET11     JMO    88/06/20 
*         MODSET CORRECTS MALET TO DISPLAY EITHER CH OR CCH IN PARAM
*         DISPLAY. PSR CML0920. 
* 
* 
* MLDVE  HWW   88/06/30.
* 
*         THIS MODSET CHANGES THE VERSION AND LEVEL NUMBER IN MLDVE 
*         FOR MALET/VE RELEASE WITH NOSVE 1.4.1 
* 
* 
* HISTORY LJC   88/07/12
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L707*. 
* 
* 
* 
* 
* CLM     JMO    88/08/15 
*         MODSET CORRECTS CLM99 TO DISPLAY MEMORY SIZE ON KL. 
*         PSR CMLA969.
* 
* 
* CMLINST NDP    88/07/01 
*         MODSET ADDS CDCNET MENUS TO CMSI. 
* 
* 
* HISTORY LJC   88/08/29
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L709*. 
* 
* 
* 
* 
* MLDVE  HWW   88/02/22.
* 
*         THIS MODSET ADDS SUPPORT TO MLDVE FOR 5698 TAPE 
*         SUB-SYSTEM. 
* 
* 
* I698    HWW    87/08/24 
*         MODSET ADDS DECK I698 TO CML 3.2. 
* 
* 
* I9X     JMO    88/08/26 
*         MODSET ADDS DECK I9X TO CML 3.2.
* 
* 
* HISTORY LJC   88/09/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L711*. 
* 
* 
* 
* 
* FMC     JMO    88/09/20 
*         MODSET CORRECTS FMC02 ON DEMOT TO NOT GET AN ERROR IF SN
*         PARAMETER IS USED DURING ASSIGN. PSR CIP0145. 
* 
* 
* FHC     JMO    88/09/20 
*         MODSET CORRECTS FHC02 ON DEMOT TO NOT GET AN ERROR IF SN
*         PARAMETER IS USED DURING ASSIGN. PSR CIP0145. 
* 
* 
* CMLA862 NDP    88/09/07 
*         MODSET FIXES DSDI DUMP FILE PARAMETER,
*         IMPROVES THE DSDI HELP MESSAGES, AND FIXES
*         THE PARAMETERS IN PROCEDURE DSDIX2. 
* 
* 
* CMLA879 NDP    88/09/07 
*         MODSET FIXES TAPE CONFIDENCE TESTING
*         WITH CHANNEL DESIGNATED.
* 
* 
* CMLA925 NDP    88/09/07 
*         MODSET ADDS TAPE VSN INFO TO TIO HELP.
* 
* 
* CMLA926 NDP    88/09/07 
*         MODSET REMOVES DEBUG CODE FROM CMSI262
* 
* 
* CMLA943 NDP    88/09/07 
*         MODSET FIXES FILE NAME PROBLEM WITH DSDI. 
* 
* 
* CMLA949 NDP    88/09/07 
*         MODSET FIXES HPA 1 DAY PROBLEM
* 
* 
* CMLA972 NDP    88/09/07 
*         MODSET REMOVES DEBUG CODE FROM CMSI262
* 
* 
* CML0914 NDP    88/09/07 
*         MODSET FIXES RECORD SIZE TEST IN TIO. 
* 
* 
* CMLA975 NDP    88/09/20 
*         MODSET PROVIDES SUPPORT FOR NOS 2.7.1.
* 
* 
* HISTORY LJC   88/10/05
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L713*. 
* 
* 
* 
* 
* CMLA976 NDP    88/10/04 
*         MODSET FIXES CMSI CDCNET PROCEDURES FOR 
*         STARTING ALL LINES (CMS263R) AND
*         STOPPING ALL LINES (CMS263O). 
* 
* 
* HPA     PSR CMLA966 
* HPA3    JOD 88/09/20
* HPA34   MODSET CMLA966 ADDS 9853 SUPPORT
* 
* 
* HPA     PSR CMLA977 
* HPA3    JOD, PWL 88/10/10 
* HPA311  MODSET CMLA977 ADDS DFT5 SUPPORT
* HPA314
* 
* 
*         PSR CMLA980 
*         JOD 88/10/26
* HPA34   MODSET CMLA980 ENHANCES 9853 SUPPORT
* 
* 
* HPA3     PWL  88/11/02
* HPA314   MODSET CORRECTS A PROBLEM WITH DFT/SCI MESSAGE DATA BLOCK REPORTING. 
* 
* 
* CLM     JMO    88/11/10 
*         MODSET CORRECTS CLM20 TO NOT HANG TRYING TO GET STATUS AFTER
*         THE DATA CHECK TEST FUNCTION. PSR CMLA982.
* 
* 
* HISTORY LJC   88/11/17
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L715*. 
* 
* 
* 
* 
* HISTORY LJC   88/12/08
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L717*. 
* 
* 
* 
* 
*         PSR CMLA985 
*         JOD 88/12/09
* HPA312  MODSET CMLA985 CORRECTS I1CR FAULT ST REG 1 ERR MESSAGE 
* 
* 
* LOW  HWW   88/12/15.
* 
*         THIS MODSET ADDS CODE TO LOW TO INSURE THAT THE EQ AND
*         UN VALUES ARE CONCATENATED AND APPEAR IN THE LOWER SIX
*         BITS OF UN IF DC=110 OR 111. EQ IS SET TO ZERO. 
* 
* 
* T7X     JMO    88/11/03 
*         MODSET CORRECTS T7X44 TO NOT GET COMPARE ERRORS ON RECORD 7777B 
*         CREATED IN T7X43. PSR CMLA987.
* 
* 
* MALET20     JMO    88/12/23 
*         MODSET CORRECTS MALET20 FOR DEMOT SO COMPILER ERRORS DO NOT 
*         OCCUR FOR FSD2, D895, P895D AND DESM. PSR CMLA988.
* 
* 
* RCV     HWW    88/12/23 
*         MODSET ADDS DECK RCV TO CML 3.2.
* 
* 
* RCV1    HWW    88/12/23 
*         MODSET ADDS DECK RCV1 TO CML 3.2. 
* 
* 
* MLDVE  HWW   88/11/23.
* 
*         THIS MODSET ADDS CODE TO MLDVE TO ALLOW THE RCV 
          PRODUCT OVERLAY TO BE CALLED. 
* 
* 
* HPA38   PSR CMLA986 
*         PWL 88/12/22
*         MODSET CMLA986 CORRECTS INCREMENT NUMBER OF 960 MEMORY. 
* 
* 
* HISTORY LJC   89/01/12
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L718*. 
* 
* 
* 
* 
* DFU     JMO    88/12/16 
*         MODSET ADDS MODULES DFU14, DFU98B AND DFU98E TO SUPPORT WRITING 
*         THE UPPER THREE CYLINDERS AFTER SHORT FORMAT. PSR CML0937.
* 
* 
* ISD1     JMO    88/01/03
*         MODSET CORRECTS ISD1 TO ISSUE A CONTINUE FUNCTION ON 834 AND
*         836 DISKS IF A RECOVERABLE ERROR IS ENCOUNTERED. PSR CML0937. 
* 
* 
* MLDVE  HWW   89/01/19.
* 
*         THIS MOD ADDS CODE TO MLDVE TO SUPPORT MASSTOR ON THE 
*         I0 IOU. 
* 
* 
* ICI  HWW   89/01/19.
* 
*         THIS MOD ADDS I0 MASSTOR SUPPORT TO THE ICI PRODUCT 
*         OVERLAY.
* 
* 
* HPA310  PSR CMLA992 
* HPA312  PWL 89/01/20
*         MODSET CMLA992 CORRECTS POTENTIAL BAD PAKS FOR 835 PFS1(81) REGISTER. 
*         IT ALSO CORRECTS A FORMAT ERROR FOR I1/I2 ELEMENT AND MODEL NUMBER IN 
*         THE DETAIL REPORT.
* 
* 
* CC0     JMO    88/01/20 
*         MODSET ADDS DECK CC0 TO CL PL.
* 
* 
* CL0     JMO    88/01/20 
*         MODSET ADDS DECK CL0 TO CL PL.
* 
* 
* I9X     JMO    88/11/03 
*         MODSET CORRECTS I9X26 AND I9X30 TO NOT GET COMPARE ERRORS ON
*         RECORD 177777B CREATED IN I9X25 OR I9X29. ALSO CORRECTS I9X77 
*         AND I9X78 TO NOT FAIL WITH ABNORMAL GS AT EOT. PSR CMLA984. 
* 
* 
* HISTORY LJC   89/02/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L719*. 
* 
* 
* 
* 
* HPA314  PSR CMLA996 
*         PWL 89/02/28
*         MODSET ADDS NEW DFT/SCI ERROR MESSAGES. 
* 
* 
* HISTORY LJC   89/03/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L721*. 
* 
* 
* 
* 
*         PSR CMLA994 
* HPA3    JOD 89/02/15
* HPA37   MODSET CMLA994 ADDS 10 MASSTOR ERROR CODES/MESSAGES 
* 
* 
* HISTORY LJC   89/04/11
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L723*. 
* 
* 
* 
* 
* HPA314  PSR CMLA998 
*         PWL 89/04/13
*         MODSET CMLA998 ADDS NEW DFT/SCI ERROR MESSAGES. 
* 
* 
* HISTORY LJC   89/05/03
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L725*. 
* 
* 
* 
* 
* HISTORY LJC   89/06/12
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L727*. 
* 
* 
* 
* 
* HISTORY LJC   89/07/17
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L729*. 
* 
* 
* 
* 
* ISD1     JMO    89/05/01
*         MODSET CORRECTS PRODUCT OVERLAY TO HANDLE RECOVERED ERRORS. 
*         PSR CMLB021.
* 
* 
* P895D     JMO    89/05/01 
*         MODSET CORRECTS PRODUCT OVERLAY TO HANDLE RECOVERED ERRORS. 
*         PSR CMLB021.
* 
* 
* DTI     JMO    89/06/02 
*         MODSET CORRECTS THE ERROR PROCESSORS FOR BOTH PRODUCT OVERLAYS
*         TO DISPLAY THE SAME ERROR FORMAT. PSR CMLB021.
* 
* 
* DESM     JMO    89/06/29
*         MODSET CORRECTS THE PROBLEM OF AN OPERATIONAL ERROR IF
*         RUNNING THE SIDE DOOR PORT ON CIO CH. ALSO ALLOWS READ
*         ERROR LOG AT CONCURRENT AL. PSR CMLB022.
* 
* 
* DESM0     JMO    89/06/29 
*         MODSET CORRECTS THE PROBLEM OF AN OPERATIONAL ERROR IF
*         RUNNING THE SIDE DOOR PORT ON CIO CH. ALSO ALLOWS READ
*         ERROR LOG AT CONCURRENT AL. PSR CMLB022.
* 
* 
* MSD     JMO    89/07/13 
*         MODSET ADDS DEVICE CODE OF 171 AND 211 FOR MALET/VE AND 
*         RESET IN MODULE 70. PSR CMLB022.
* 
* 
* SSD     JMO    89/07/13 
*         MODSET ADDS DEVICE CODE OF 171 AND 211 FOR MALET/VE AND 
*         RESET IN MODULE 70. PSR CMLB022.
* 
* 
* HISTORY LJC   89/08/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L731*. 
* 
* 
* 
* 
* MSM     JMO    89/08/08 
*         MODSET CORRECTS THE WRESM EQUATE TO BE 25B INSTEAD OF 24B.
*         PSR CMLB023.
* 
* 
* SSM     JMO    89/08/08 
*         MODSET CORRECTS THE WRESM EQUATE TO BE 25B INSTEAD OF 24B.
*         PSR CMLB023.
* 
* 
* CC0     JMO    89/05/10 
*         MODSET CORRECTS MISCELLANEOUS DOCUMENTATION ERRORS IN CC0.
*         ALSO CORRECTS SUBR ENTRY/EXIT ERR CC001. PSR CMLB024. 
* 
* 
* MSD     JMO    89/08/10 
*         MODSET ADDS SUPPORT OF DEVICE CODES 171 AND 211 TO ALL MODULES. 
*         PSR CMLB026.
* 
* 
* SSD     JMO    89/08/10 
*         MODSET ADDS SUPPORT OF DEVICE CODES 171 AND 211 TO ALL MODULES. 
*         PSR CMLB026.
* 
* 
* MLDVE  HWW   89/08/22.
* 
*         THIS MODIFICATION UPDATES THE VERSION AND LEVEL MARKERS 
*         IN MLDVE FOR NOSVE 1.5.1 RELEASE. 
* 
* 
* HISTORY GLG   89/08/28
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L739*. 
* 
* 
* 
* 
* HISTORY GLG   89/08/28
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L739A*.
* 
* 
* 
* 
* CCM     JMO    89/02/10 
*         MODSET ADDS SUPPORT FOR DC=105 MASSTOR HPO AND DC=47
*         CCC CARTRIDGE TAPE TO CCM. PSR CMLB032. 
* 
* 
* CLM     JMO    89/02/10 
*         MODSET ADDS SUPPORT FOR DC=105 MASSTOR CSS AND DC=47
*         CCC CARTRIDGE TAPE TO CLM. PSR CMLB032. 
* 
* 
* MALET10     JMO    89/02/10 
*         MODSET ADDS SUPPORT OF CARTRIDGE TAPE TO MALET. ALSO ADDS 
*         DC 105 SUPPORT TO MALET. PSR CMLB031. 
* 
* 
* MALET20     JMO    89/02/10 
*         MODSET ADDS LANGUAGE SUPPORT FOR CARTRIDGE TAPE.
*         PSR CMLB031.
* 
* 
* MLD     JMO    89/02/10 
*         MODSET ADDS CARTRIDGE TAPE SUPPORT TO MLD.
*         PSR CMLB031.
* 
* 
* MLDVE     JMO    89/02/10 
*         MODSET ADDS CARTRIDGE TAPE SUPPORT TO MLDVE.
*         PSR CMLB031.
* 
* 
* MLD     JMO    89/10/18 
*         MODSET ADDS PERMANENT DEFINE OF CART TO SUPPORT CARTRIDGE TAPE. 
*         PSR CMLB033.
* 
* 
* DCART     JMO    89/02/10 
*         MODSET ADDS COMDECK DCART TO CML 3.2. 
* 
* 
* MALET2M     JMO    89/02/10 
*         MODSET ADDS DECK MALET2M TO CML 3.2.
* 
* 
* MALETPM     JMO    89/02/10 
*         MODSET ADDS COMDECK MALETPM TO CML 3.2. 
* 
* 
* TCT     JMO    89/02/10 
*         MODSET ADDS DECK TCT TO CML 3.2.
* 
* 
* HISTORY GLG   89/10/18
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L739B*.
* 
* 
* 
* 
* HPA     PSR CMLB029 
* HPA3    PWL 89/10/27
* HPA314  MODSET CMLB029 PROVIDES SUPPORT FOR EPM.  IT ALSO ADDS THE REPORTING
*         OF NEGATIVE SIT CONDITION.
* 
* 
* HPA312  PSR CMLB034 
*         PWL 89/10/27
*         MODSET CMLB034 PROVIDES SUPPORT FOR I4S.
* 
* 
* HPA38   PSR CMLB035 
* HPA312  PWL 89/10/27
* HPA314  MODSET CMLB035 ADDS TEXT NEEDED FOR MEMORY IO PORT ERROR(S) AND 
*         FOR CIO CHANNEL ERROR(S). 
* 
* 
* HISTORY GLG   89/10/31
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L739C*.
* 
* 
* 
* 
* CMLINST     JMO    89/10/02 
*         MODSET CORRECTS CMSI PROC CMSI210 XREF FOR ESM/STORNET. 
*         PSR CMLB027.
* 
* 
* CMLINST     JMO    89/10/02 
*         MODSET CORRECTS CMSI CPU TEST INTERFACE TO INCLUDE 960 TYPE 
*         MAINFRAMES. PSR CMLB028.
* 
* 
* HISTORY GLG   89/12/04
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L741*. 
* 
* 
* 
* 
* HISTORY GLG   89/12/05
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L741A*.
* 
* 
* 
* 
* HISTORY GLG   90/02/06
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L750*. 
* 
* 
* 
* 
* MLDVE  HWW   90/02/21.
* 
*         THIS MODSET UPDATES THE VERSION AND LEVEL MARKERS IN MLDVE
*         TO THE CORRECT VALUE FOR THE NOS/VE 1.5.2 RELEASE.
* 
* 
* HISTORY GLG   90/02/22
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L750A*.
* 
* 
* 
* 
* HPA34  PSR CMLB038
*        PWL 90/03/27 
*        MODSET CMLB038 ADDS XMD FAULTS CODES 74, 75 AND MODIFIES XMD DETAIL
*        REPORT TO INCLUDE MORE INFORMATION FOR 105 UNRECOVERED ERRORS. 
* 
* 
* DCART     JMO    89/10/25 
*         MODSET ADDS TIMEOUT RETRY IN PROCESS ERROR CODE.
*         PSR CMLB036.
* 
* 
* TCT     JMO    90/02/02 
*         MODSET CORRECTS ERROR CODE 214 POSTED ALONG WITH 215. 
*         PSR CMLB036.
* 
* 
* HISTORY GLG   90/04/02
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L750B*.
* 
* 
* 
* 
* MLDVE  HWW   90/06/14.
* 
*         THIS MOD UPDATES MLDVE TO CALL NEW DAS PRODUCT
*         OVERLAY.
* 
* 
* DDAS    HWW    90/06/15 
*         MODSET ADDS DECK DDAS TO CML 3.2. 
* 
* 
* IDA     HWW    90/06/15 
*         MODSET ADDS DECK IDA TO CML 3.2.
* 
* 
* HISTORY GLG   90/06/25
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L757*. 
* 
* 
* 
* 
* DCART     JMO    90/08/22 
*         MODSET CORRECTS GETS ROUTINE TO HANDLE RETRIES CORRECTLY. 
*         PSR CMLB044.
* 
* 
* MLDVE  HWW   90/08/23.
* 
*         THIS MODSET ADDS CODE TO MLDVE WHICH UPDATES
*         THE VERSION AND LEVEL IDENTIFIERS TO V1.8/L757
*         WHICH CORRESPONDS TO THE NOS/VE 1.5.2 RELEASE.
* 
* 
* DDAS  HWW   90/08/27. 
* 
*         THIS MODSET UPDATES DDAS DECK TO SUPPORT PARALLEL 
*         DAS CONFIGURATIONS. 
* 
* 
* IDA  HWW   90/08/23.
* 
*         THIS MODSET MODIFIES IDA DIAGNOSTIC TO SUPPORT
*         PARALLEL DAS CONFIGURATIONS.
* 
* 
* HISTORY GLG   90/08/28
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L757B*.
* 
* 
* 
* 
* MLDVE  HWW   90/08/29.
* 
*         THIS MODSET UPDATES THE MLDVE VERSION AND LEVEL TO THE
*         CORRECT VALUES FOR THE NOS/VE 1.5.3 RELEASE.
* 
* 
* HISTORY GLG   90/09/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L762*. 
* 
* 
* 
* 
* HISTORY GLG   90/09/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L762A*.
* 
* 
* 
* 
* DDAS  HWW   90/09/14. 
* 
*         THIS MODSET CORRECTS A PROBLEM IN RUNNING DRIVE DIAGNOSTICS.
* 
* 
* IDA  HWW   90/09/25.
* 
*         MODSET CORRECTS PROBLEMS IN MODULE 31 WHICH CAUSED
*         COMPILER ERRORS BECAUSE OF LONG LINES. ALSO ADDS
*         CODE TO MODULE 00 TO SKIP SECTION 56 OF CONTROLLER
*         IN-LINES. 
* 
* 
* IDA     JMO    90/09/27 
*         MODSET CORRECTS DMA DETECTION PROBLEM IN IDA
*         DIAGNOSTIC. PSR MAVA134.
* 
* 
* HISTORY GLG   90/09/27
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L762B*.
* 
* 
* 
* 
* DDAS  HWW   90/09/28. 
* 
*         THIS MODSET FIXES DRIVE BUSY PROBLEM WHICH WAS DETECTED 
*         BY THE NOS/VE DRIVER WHEN THE IDA TEST WAS RUNNING. 
* 
* 
* HISTORY GLG   90/09/28
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L762C*.
* 
* 
* 
* 
* 67X     JMO    90/06/22 
*         MODSET CORRECTS NO INACTIVE ON REWIND PROBLEM IN 698 ON A 
*         FIBRE EXTENDER. PSR CML0964.
* 
* 
* HISTORY GLG   90/11/16
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L765*. 
* 
* 
* 
* 
* CLM     JMO    90/10/30 
*         MODSET CORRECTS CLM20 TO NOT TIME OUT USING M862SD MICROCODE
*         LEVELS PF3 OR PF5. PSR CMLB046. 
* 
* 
* HPA310  PSR CML0929 
*         JLD 90/09/04
*         MODSET CML0929 CORRECTS INCORRECT ENTRIES IN HPA310 DECK. 
* 
* 
* COMHPAERT 
*         PSR CML0966 
*         JLD 90/08/28
*         MODSET CML0966 CORRECTS TYPOS IN COMHPAERT DECK.
* 
* 
* HPA314  PSR CMLB042 
*         JLD 90/09/20
*         MODSET CMLB042 FIXES AN INCORRECT ROW CALLOUT FOR 990 MEMORY
* 
* 
* HISTORY GLG   90/12/12
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L765A*.
* 
* 
* 
* 
* MALET     JMO    90/08/30 
*         MODSET ADDS DAS AND XMD NOS SUPPORT TO MALET. 
*         PSR CMLB047.
* 
* 
* MALET10     JMO    90/07/05 
*         MODSET ADDS DAS AND XMD NOS SUPPORT TO MALET. 
*         PSR CMLB047.
* 
* 
* MALET11     JMO    90/08/31 
*         MODSET ADDS DAS AND XMD NOS SUPPORT TO MALET. 
*         PSR CMLB047.
* 
* 
* MALET12     JMO    90/10/12 
*         MODSET ADDS DAS AND XMD NOS SUPPORT TO MALET. 
*         PSR CMLB047.
* 
* 
* MALET20     JMO    90/06/28 
*         MODSET ADDS DAS AND XMD NOS SUPPORT TO MALET. 
*         PSR CMLB047.
* 
* 
* MLDVE     JMO    90/09/11 
*         MODSET CORRECTS DEFINES FOR MLDVE TO SEPARATE THE IPI 
*         PRODUCT OVERLAYS AND TO LIST THE COMMON DECKS. PSR CMLB048. 
* 
* 
* MLD     JMO    90/12/14 
*         MODSET ADDS NEW PERMANENT DEFINES FOR IPI PRODUCT OVERLAYS. 
*         PSR CMLB049.
* 
* 
* DDAS     JMO    90/09/05
*         MODSET ADDS NOS SUPPORT.
*         PSR CMLB050.
* 
* 
* IDA     JMO    90/10/17 
*         MODSET ADDS NOS SUPPORT.
*         PSR CMLB050.
* 
* 
* IFSD     JMO    90/07/02
*         MODSET ADDS NOS SUPPORT.
*         PSR CML0957.
* 
* 
* IDT     JMO    90/10/29 
*         MODSET ADDS NOS SUPPORT.
*         PSR CML0957.
* 
* 
* MALET2T     JMO    90/06/26 
*         MODSET ADDS DECK MALET2T TO CML 3.2.
* 
* 
* MALETPT     JMO    90/06/26 
*         MODSET ADDS COMDECK MALETPT TO CML 3.2. 
* 
* 
* MALET2U     JMO    90/09/04 
*         MODSET ADDS DECK MALET2U TO CML 3.2.
* 
* 
* MALETPU     JMO    90/09/04 
*         MODSET ADDS COMDECK MALETPU TO CML 3.2. 
* 
* 
* COMPCHN DJJ   11/15/82
*         THIS MODSET ADDS THE COMMON DECK COMPCHN TO THE MALET PROGRAM 
*         LIBRARY.  IT PROVIDES THE CAPABILITY OF BUILDING A TABLE OF 
*         ADDRESSES WHICH IDENTIFY INSTRUCTIONS THAT REQUIRE CHANNEL
*         MODIFICATION. 
* 
* 
* COMPMSG DJJ   11/15/82
*         THIS MODSET ADDS THE COMMON DECK COMPMSG TO THE MALET PROGRAM 
*         LIBRARY.  IT PROVIDES THE CAPABILITY OF BUILDING MESSAGES 
*         IN A MALET PRODUCT OVERLAY WHICH CAN BE WRITTEN TO THE
*         COMMUNICATIONS BLOCK PRODUCT OVERLAY MESSAGE BUFFER AND 
*         REFERENCED DURING EXECUTION TIME VIA A CALL TO THE MALET
*         EXECUTIVE.
* 
* 
* COMPOVR DJJ   11/15/82
*         THIS MODSET ADDS THE COMMON DECK COMPOVR TO THE MALET PROGRAM 
*         LIBRARY.  IT IS CALLED AT THE END OF EACH PRODUCT OVERLAY TO
*         DETERMINE IF THE PRODUCT OVERLAY IS TOO LONG TO BE LOADED BY
*         THE OPERATING SYSTEM WITHOUT CAUSING PP WRAP-AROUND.
* 
* 
* WLD     DJJ   11/15/82   JMO   09/05/90 
*         THIS MODSET ADDS THE DECK WLD TO THE MALET PROGRAM LIBRARY. 
*         IT IS THE MAINTENANCE LANGUAGE DRIVER FOR ALL MALET MODULES 
*         WHICH EXECUTE IN 16-BIT MODE ON AN 800 SERIES MAINFRAME IOU.
*         IT PROVIDES THE CAPABILITIES WHICH ARE NECESSARY TO EXECUTE 
*         MALET NON-I/O COMMANDS. 
* 
* 
* CMLINST     JMO    91/01/07 
*         MODSET ADDS IPIDISK AND WLD SUPPORT TO CMLINST. 
*         PSR CMLB051.
* 
* 
* HISTORY GLG   91/01/16
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L769*. 
* 
* 
* 
* 
* DFU     JMO    91/01/08 
*         MODSET ADDS 4128D BYTE RECORD SIZE FORMAT TO DFU01 VIA
*         PARAMETER P0. PSR CMLB052.
* 
* 
* HISTORY GLG   91/01/16
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L769A*.
* 
* 
* 
* 
* COMSIPA  GLG    01/16/91
*          MODSET MOVES COMMMON DECK COMSIPA TO CL PROGRAM LIBRARY
* 
* 
* COMSIPA  GLG    01/16/91
*          MODSET MOVES COMMMON DECK COMPIPA TO CL PROGRAM LIBRARY
* 
* 
* COMPCHO  GLG    01/16/91
*          MODSET MOVES COMMMON DECK COMPCHI TO CL PROGRAM LIBRARY
* 
* 
* COMPMAC  GLG    01/16/91
*          MODSET MOVES COMMMON DECK COMPMAC TO CL PROGRAM LIBRARY
* 
* 
* HPA     PSR CMLB043 
* HPA1    JLD 90/11/05
* HPA22   MODSET CMLB043 PROVIDES SUPPORT FOR DAS (DISK ARRAY SUBSYSTEM)
* HPA3
* HPA34 
* COMHPAERT 
* 
* 
* HISTORY GLG   91/02/19
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L769B*.
* 
* 
* 
* 
* DDAS     JMO    91/01/30
*         MODSET ALLOWS THE DROPPING OF THE CHANNEL WHILE FORMATTING. 
*         PSR CMLB054.
* 
* 
* IFSD     JMO    91/01/30
*         MODSET ALLOWS THE DROPPING OF THE CHANNEL WHILE FORMATTING. 
*         PSR CMLB054.
* 
* 
* IDA     JMO    91/01/30 
*         MODSET ALLOWS THE DROPPING OF THE CHANNEL WHILE FORMATTING. 
*         PSR CMLB054.
* 
* 
* IDT     JMO    91/01/30 
*         MODSET ALLOWS THE DROPPING OF THE CHANNEL WHILE FORMATTING. 
*         PSR CMLB054.
* 
* 
* HISTORY GLG   91/04/12
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L774*. 
* 
* 
* 
* 
* HISTORY GLG   91/04/12
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L774A*.
* 
* 
* 
* 
* HPA34   PSR CMLB43A 
*         JLD 91/03/15
*         MODSET CMLB43A ADDS NEW ERROR CODE FOR DAS (DISK ARRAY SUBSYSTEM) 
* 
* 
* HPA38   PSR CMLB053 
*         JLD 91/03/05
*         MODSET CMLB053 PROVIDES SUPPORT FOR PIM3 MODEL 35 MEMORY
* 
* 
* HISTORY GLG   91/03/18
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L774B*.
* 
* 
* 
* 
* HPA34   PSR CML0973 
*         JLD 91/04/10
*         MODSET CML0973 REPORTS CORRECTED ERRORS PROPERLY, NOT AS
*         UNCORRECTED ERRORS. 
* 
* 
* HPA34   PSR CMLB043B
*         JLD 91/03/15
*         MODSET CMLB043B ADDS NEW ERROR CODES FOR DAS (DISK ARRAY SUBSYSTEM) 
*         FOR CONFIGURATIONS USING PARITY DRIVES. 
* 
* 
* HPA34   PSR CMLB043C
*         JLD 91/04/15
*         MODSET CMLB043C ADDS A NEW ERROR CODE FOR DAS (DISK ARRAY SUBSYSTEM)
* 
* 
* HISTORY GLG   91/04/12
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L774C*.
* 
* 
* 
* 
* MFI     JMO    91/03/04 
*         MODSET ADDS DECK MFI TO CML 3.2.
* 
* 
* MLDVE  HWW   91/04/24.
* 
*         THIS MODIFICATION UPDATES THE VERSION AND LEVEL MARKERS 
*         IN MLDVE FOR THE NOS/VE 1.6.1 L780 RELEASE. 
* 
* 
* HPA34   PSR CMLB043D
*         JLD 91/04/23
*         MODSET CMLB043D FIXES ERROR CODE PROCESSING FOR DAS (DISK ARRAY 
*         SUBSYSTEM) FOR CONFIGURATIONS USING PARITY DRIVES.
* 
* 
* HISTORY GLG   91/05/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L780*. 
* 
* 
* 
* 
* COMPIPI     JMO    91/01/11 
*         MODSET ADDS COMDECK COMPIPI TO S0 PL. 
* 
* 
* COMSIPI     JMO    91/01/11 
*         MODSET ADDS COMDECK COMSIPI TO S0 PL. 
* 
* 
* HISTORY GLG   91/06/10
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L780A*.
* 
* 
* 
* 
* MALETPM     JMO    91/05/17 
*         MODSET ADDS SUPPORT TO MALETPM TO TEST FCO CA 51479.
*         PSR CMLB058.
* 
* 
* DCART     JMO    91/05/17 
*         MODSET ADDS SUPPORT TO DCART TO TEST FCO CA 51479.
*         PSR CMLB058.
* 
* 
* TCT     JMO    91/05/24 
*         MODSET ADDS SUPPORT TO TCT TO TEST FCO CA 51479.
*         PSR CMLB058.
* 
* 
* MLDVE  HWW   91/06/24.
* 
*         THIS MODIFICATION ADDS SUPPORT TO MLDVE FOR THE IPI 
*         CHANNEL LOOPBACK PRODUCT OVERLAY. 
* 
* 
* DLBK    HWW    91/06/21 
*         THIS MODSET CREATES NEW DECK DLBK WHICH IS THE
*         IPI CHANNEL LOOPBACK PRODUCT OVERLAY. 
* 
* 
* HPA3    PSR CMLB057 
* HPA32   JLD 91/06/14
* HPA34   MODSET CMLB057 PROVIDES A "DON'T PANIC' MESSAGE FOR DATA
*         OVERRUNS ON DISK AND LATE DATA ERRORS ON TAPE.
* 
* 
* MLD     JMO    91/06/24 
*         MODSET ADDS LBK TO PERMANENT DEFINES IN THE CML PL. 
*         PSR CMLB059.
* 
* 
* COMSIPA     JMO    91/03/13 
*         MODSET ADDS TASK 23 TO SUPPORT UTILITY DASC.
*         PSR CMLB060.
* 
* 
* COMPIPA     JMO    91/03/13 
*         MODSET ADDS TASK 23 TO SUPPORT UTILITY DASC.
*         PSR CMLB060.
* 
* 
* HISTORY RJR   91/07/10
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L780B*.
* 
* 
* 
* 
* HPA34   PSR CMLB057 
*         JLD 91/08/14
*         MODSET CMLB061 ADDS THE CONTROLLER ENDING STATUS TO THE 
*         FIELDS DISPLAYED FOR 9853 AND 583X ERROR ENTRIES. 
* 
* 
*         PSR CMLB065 
* HPA34   JLD 91/10/14
*         MODSET CMLB065 ADDS HPA SUPPORT FOR CARTRIDGE TAPE
*         AND AUTOMATIC CARTRIDGE TAPE SUBSYSTEMS.
* 
* 
*         PSR CMLB062 
* HPA     JLD 91/12/16
* HPA1    MODSET CMLB062 ADDS HPA SUPPORT FOR CARTRIDGE TAPE
* HPA2    AND AUTOMATIC CARTRIDGE TAPE SUBSYSTEMS.
* HPA21 
* HPA22 
* HPA3
* HPA33 
* HPA8
* HPA9
* COMHPAERT 
* 
* 
* HPA     PSR CMLB062A
* HPA1    JLD 91/10/14
* HPA2    MODSET CMLB062A DELETES CODE FOR OBSOLETE MSS 
* HPA21 
* HPA8
* HPA9
* COMHPAERT 
* 
* 
* T7X     JMO    91/12/10 
*         MODSET ADDS MODULE T7X63 TO TEST ASSEMBLY/DISASSEMBLY BOARD IN
*         THE CCC THAT IS NOT PARITY PROTECTED. PSR CMLB066.
* 
* 
* MALET     JMO    91/12/06 
*         MODSET CORRECTS MALET TO ADD A MESSAGE THAT CIO CHANNEL NOT 
*         ASSIGNED TO WLD. THEREFORE ELIMINATING THE POSSIBILTY OF A
*         PP HANG. CMLB067. 
* 
* 
* MALET10     JMO    91/12/06 
*         MODSET CORRECTS MALET TO ADD A MESSAGE THAT CIO CHANNEL NOT 
*         ASSIGNED TO WLD. THEREFORE ELIMINATING THE POSSIBILTY OF A
*         PP HANG. CMLB067. 
* 
* 
* MALET10     JMO    91/11/21 
*         MODSET ADDS CARTRIDGE TAPE SUPPORT TO MALET.
*         PSR CMLB068.
* 
* 
* DCART     JMO    91/12/02 
*         MODSET ADDS DEVICE CODE 46 SUPPORT TO DCART.
*         PSR CMLB068.
* 
* 
* TCT     JMO    91/12/02 
*         MODSET ADDS DC = 46 TO TCT. 
*         PSR CMLB069.
* 
* 
* CCM     JMO    91/12/02 
*         MODSET ADDS DC = 46 TO CCM. 
*         PSR CMLB069.
* 
* 
* CLM     JMO    91/12/02 
*         MODSET ADDS DC = 46 TO CLM. 
*         PSR CMLB069.
* 
* 
* COMPIPA     JMO    91/10/23 
*         MODSET CORRECTS FAILURES THAT OCCUR ON 25 MB CHANNEL WHEN 
*         CONTROLLERS ARE DAISY CHAINED TOGETHER. PSR CMLB063.
* 
* 
* COMPIPI     JMO    91/10/23 
*         MODSET CORRECTS FAILURES THAT OCCUR ON 25 MB CHANNEL WHEN 
*         CONTROLLERS ARE DAISY CHAINED TOGETHER. PSR CMLB063.
* 
* 
* MLD     JMO    91/10/25 
*         MODSET ADDS 5698M TO PERMANENT DEFINES IN THE PL. 
*         PSR CMLB064.
* 
* 
* HPA2    PSR CML0965 
*         JLD 91/11/14
*         MODSET CML0965 FIXES PROBLEM WITH DISCARDING ON-THE-FLY 
*         AND LATE-DATA TAPE ERRORS WHEN ENTRY APPEARS TO BE THE
*         SAME AS THE PREVIOUS ENTRY. 
* 
* 
* CMLINST     JMO    91/12/20 
*         MODSET ADDS CARTRIDGE TAPE SUPPORT TO CMLINST PROCS.
*         PSR CMLB070.
* 
* 
* HISTORY RJR   92/01/10
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L780C*.
* 
* 
* 
* 
* HPA3    PSR CMLB062 
* COMHPA- JLD 92/01/16
*    ERT  MODSET CMLB062B FIXES HPA SUPPORT FOR CARTRIDGE TAPE
*         AND AUTOMATIC CARTRIDGE TAPE SUBSYSTEMS.
* 
* 
* CLM     JMO    91/01/16 
*         MODSET CORRECTS GENERAL STATUS POSTING IN MODULE 30 TO ALSO 
*         POST EXPECTED. PSR CMLB071. 
* 
* 
* CCM     JMO    91/01/16 
*         MODSET CORRECTS GENERAL STATUS POSTING IN MODULE 30 TO ALSO 
*         POST EXPECTED. PSR CMLB071. 
* 
* 
*         PSR CMLB065 
* HPA34   JLD 92/01/21
* COMHPA- MODSET CMLB065A FIXES HPA SUPPORT FOR DAS AND XMD 
*  ERT    DIFFERENCES.
* 
* 
* HISTORY RJR   92/01/22
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L780D*.
* 
* 
* 
* 
*         PSR CMLB072 
* HPA34   JLD 92/02/24
*         MODSET CMLB072 ADDS HPA SUPPORT FOR OPTICAL DISK
*         SUBSYSTEMS. 
* 
* 
* HISTORY RJR   92/02/27
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L797*. 
* 
* 
* 
* 
*         PSR CMLB072 
* HPA34   JLD 92/03/05
*         MODSET CMLB072B FIXES HPA SUPPORT FOR OPTICAL DISK
*         SUBSYSTEMS. 
* 
* 
* HISTORY RJR   92/03/12
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L797A*.
* 
* 
* 
* 
* HPA     PSR CMLB082 
*         JLD 92/08/11
*         MODSET CMLB082 UPDATES COPYRIGHT STATEMENT FOR HPA. 
* 
* 
* HPA34   PSR CMLB076 
*         JLD 92/08/23
*         MODSET CMLB076H FIXES A PROBLEM WITH MR ENTRIES 
*         BEING PICKED UP AS OPTICAL DISK ENTRIES.
* 
* 
* HPA3    PSR CMLB078 
* HPA33   JLD 92/09/01
*         MODSET CMLB078 FIXES A PROBLEM WITH INCORRECT 
*         MOUNT COUNTS FOR CTS/ACS TAPES. 
* 
* 
* HISTORY RJR   92/09/18
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L803A*.
* 
* 
* 
* 
* DDAS  HWW   93/01/31. 
* 
*         THIS MODIFICATION ADDS ELITE 2 DISK DRIVE SUPPORT 
*         TO THE DDAS PRODUCT OVERLAY.
* 
* 
* MLDVE  HWW   93/01/25.
* 
*         THIS MODIFICATION UPDATES THE MLDVE VERSION AND 
*         LEVEL MARKERS FOR THE L780AA NOSVE RELEASE. 
* 
* 
* IDE     HWW    93/02/03 
*         MODSET ADDS DECK IDE TO CML 3.2.
* 
* 
* HISTORY JLD   93/02/09
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L803B*.
* 
* 
* 
* 
* IDE  HWW   93/02/15.
* 
*         THIS MOD DELETES A TYPO OUT OF THE EXTERNAL 
*         DOCUMENTATION WHICH WAS CAUSING COMPILE 
*         PROBLEMS. 
* 
* 
* HISTORY JLD   93/02/23
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L803C*.
* 
* 
* 
* 
*         PSR CML0977 
* HPA3    JLD 93/05/04
* HPA34   MODSET CML0977 FIXES PROBLEM WITH HPA DETAILED DATA 
*         NOT BEING CORRECT WHEN PARAMETER MMF IS SELECTED. 
* 
* 
* HISTORY JLD   93/09/16
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L826*. 
* 
* 
* 
* 
* MALET10  HWW   93/12/15.
* 
* THIS MODSET ADDS ELITE 2 SUPPORT TO MALET.
* 
* 
* MALET11  HWW   93/12/15.
* 
* THIS MODSET ADDS ELITE 2 SUPPORT TO MALET.
* 
* 
* DDAS  HWW   93/12/15. 
* 
* THIS MODSET ADDS ELITE 2 SUPPORT TO MALET.
* 
* 
* IDE  HWW   93/11/17.
* 
* THIS MODSET ADDS ELITE 2 SUPPORT TO MALET.
* 
* 
* HPA34   PSR CMLB083 
*         JLD 93/11/05
*         MODSET CMLB083 PROVIDES SUPPORT FOR ELITE II DAS
* 
* 
* HISTORY JLD   93/12/15
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L826A*.
* 
* 
* 
* 
* COMHPAERT  PSR CMLB080
*            JLD 94/02/20 
*            MODSET CMLB080 PROVIDES SOFTWARE ERROR CODES IN COMHPAERT
*            DESCRIPTIONS OF TAPE ERRORS
* 
* 
*         PSR CML0982 
* HPA9    JLD 94/02/15
*         MODSET CML0982 FIXES PROBLEM WITH HPA MEDIA REPORTS 
*         WHERE THE CARTRIDGE TAPE R/W USAGE VALUES ARE SWAPPED.
* 
* 
* HPA        PSR CMLB081
* COMHPAERT  JLD 94/02/15 
*            MODSET CMLB081 PROVIDES RECOVERED/UNRECOVERED ERROR
*            DIFFERENTIATION FOR CARTRIDGE TAPES
* 
* 
* HISTORY JLD   94/05/24
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L840*. 
* 
* 
* 
* 
* COMHPA- PSR CMLB085 
* ERT     JLD 94/06/30
* HPA     MODSET CMLB085 PROVIDES SUPPORT FOR 3.5IN DAS AND ADDITIONAL
* HPA3    MODELS OF ELITE II AND SABRE DAS. 
* HPA34 
* 
* HISTORY JLD   94/12/28
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L847*. 
* 
* 
* 
* 
* HPA     PSR CMLB086 
* HPA32   JLD 94/12/15
* HPA34   MODSET CMLB086 PROVIDES SUPPORT FOR CDSS2 DISK
* 
* 
* HISTORY JLD   94/12/28
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L850*. 
* 
* 
* 
* 
* HISTORY JLD   95/06/07
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L851*. 
* 
* 
* 
* 
*         PSR CML0986 
* CMLINST JLD 95/09/14
*         MODSET CML0986 FIXES PROBLEM OF CML INSTALLATION JOB CML5 
*         ABORTING IF CARTRIDGE TAPE NOT BEING INSTALLED. 
* 
* 
* HPA21   PSR CML0987 
* HPA3    JLD 95/09/11
* HPA5    MODSET CML0987 FIXES HPA PROBLEMS WITH TOP-OF-CENTURY 
* HPA8
* HPA9
* 
* 
* HPA3   PSR CML0988
* HPA34  REH 95/10/31  MODIFIED BY JLD 96/03/18 
*        MODSET CML0988 ADDS CODE TO LIMIT THE NUMBER OF MESSAGES 
*               PRINTED FOR DAS ERRORS.  LIMIT WILL 
*               BE 6 AS A DEFAULT.
* 
* 
* COMHPA-  PSR CML0989
* ERT      REH 95/10/31 
* HPA34    MODSET CML0989 PROVIDES ADDITIONAL ERROR CODES FOR 
*          DAS DISKS.  IT ALSO PROVIDES AN INITIAL AND FINAL
*          FAULT MESSAGE FOR DAS ERROR MESSAGES.  THE MESSAGES
*          CONFORM TO THE NOS DOS DRIVER ERROR CODES. 
* 
* 
* HPA9   PSR CML0990
*        REH 95/11/28 
*        MODSET CML0990 ADDS CODE TO REPORT USAGE DATA
*               WHEN A TAPE IS WRITTEN THE READ ON THE
*               SAME TAPE UNIT. 
* 
* 
* HPA9   PSR CML0991
*        REH 96/01/08 
*        MODSET CML0991 ADDS CODE TO CORRECTLY REPORT 
*               RECOVERED AND UNRECOVERED READ OR WRITE 
*               ERROR CONDITIONS FOR CARTRIDGE DEVICE 
*               TYPE 47.
* 
* 
* HISTORY JLD   96/04/02
*         THIS MODSET UPDATES THE BUILD IDENTIFIER FOR
*         THIS BUILD TO *L859*. 
* 
* 
* 
* 
* MSS/LCN GLG    83/08/05 
*        THIS MODSET PURGES THE IDENTS AND DECKS
*        FOR MSS AND ESM DIAGNOSTICS FOR CML RELEASE. 
* 
* 
* CMLINST  IE   87/12/23
*          MODSET CORRECT THE LEVEL MARKER ON CML PROGRAM LIBRARY 
* 
*         *** END OF COMDECK HISTORY ***
